Garbage and Organics Collection and Disposal Bylaw No. 1252, 2018
Gibsons, British Columbia
This is the exact embedded text of the captured official document.
Snapshot 7b32655b7cd1 · verified 2026-06-08 ·
original document ·
archived snapshot ·
unofficial consolidation, the official version is held by the municipal clerk.
TOWN OF GIBSONS
BYLAW NO. 1252-04, 2021
A Bylaw to amend Town of Gibsons Garbage Collection and Disposal Bylaw No. 1252, 2018;
WHEREAS the Council of the Town of Gibsons has adopted Garbage Collection and Disposal
Bylaw No. 1252, 2018;
AND WHEREAS the Council of the Town of Gibsons deems it desirable to amend Bylaw
No. 1252, 2018;
NOW THEREFORE the Council of the Town of Gibsons, in open meeting assembled, enacts as
follows:
PART A - CITATION
1.
This Bylaw may be cited for all purposes as "Garbage Collection and Disposal
Amendment Bylaw No. 1252-04, 2021".
PART B - AMENDMENT
2.
Town of Gibsons Garbage Collection and Disposal Amendment Bylaw No. 1252, 2018
as hereby amended as follows:
a) By altering Section 4 "Definitions" with the following:
i.
the definition for Wildlife Resistant Enclosure be deleted and replaced with
the following:
ii.
the definition for Commercial Refuse Container be added:
b) By deleting Section 5.2.1 and replacing with the following:
5.2.1 Provide and maintain in good and sufficient order and repair:
5.2.1.1
a Commercial Refuse Container that meets the criteria
established in Schedule B; or
WILDLIFE
RESISTANT
ENCLOSURE
means a structure which has four enclosed sides, a
roof, doors, and a latching device of sufficient design
and strength to prevent access by dangerous wildlife,
and for clarity, includes a garage, shed, or other
structure that is inaccessible to wildlife and that is
designed and constructed in accordance with the
specifications set out in Schedule C
COMMERCIAL
REFUSE
CONTAINER
means a metal receptacle that is designed or intended
to dispose of waste by automated means and is
wildlife proof
5.2.1.2
a container enclosed within a Wildlife Resistant Enclosure
that is designed and constructed in accordance with the
criteria established in Schedule C.
c)
By deleting Section 5.2.3;
d) By adding Schedule B - Commercial Refuse Container, attached to and forming part
of this bylaw;
e) By adding Schedule C - Solid Waste Wildlife Resistant Enclosure, attached to and
forming part of this bylaw; and
f)
Making such consequential alterations and annotations as are required to give
effect to this amending bylaw, including renumbering of the Bylaw.
PART C - ADOPTION
READ A FIRST TIME this
20th
2021
READ A SECOND TIME this
####
202x
READ A THIRD TIME this
####
202x
ADOPTED this
####
DAY OF APRIL,
DAY OF MONTH ,
DAY OF MONTH ,
DAY OF MONTH ,
202x
William Beamish, Mayor
Rebecca Anderson, Corporate Officer
Schedule B
Commercial Refuse Container
The following criteria applies to a commercial refuse container:
1. The lid or lids, and any man doors, must close tightly to prevent access by Wildlife and/or
Dangerous Wildlife.
2. The lid or lids, and any man doors, must be:
a) self-closing; or
b) self-latching; or
c) capable of being completely closed and secured with a latching device.
3. The latches for the lid or lids and bag removal must be such that an adult bear using its
claws will be unlikely to reach the latch trigger mechanism.
4. Hinges and latches for lids must be sufficiently strong, and sufficiently affixed to the
container, that they cannot be pried open by an adult bear using its claws. As a guideline,
a lid that can be dismantled using a crowbar is not sufficient.
5. The container must be sufficiently stable or capable of being so anchored as to prevent
tipping by a bear.
6. Container material must be of sufficient strength to prevent Wildlife and/or Dangerous
Wildlife from chewing, battering or crushing the container.
DWG. NO.: G11
DATE: JULY 2017
SOLID WASTE WILDLIFE-PROOF ENCLOSURE
TOWN OF GIBSONS
SCALE: N.T.S.
DRAWN BY: BL
NOTES:
1. Enclosure architecture (materials, etc) is to conform to Municipal
Building and Development Permit requirements (as required).
2. Design concept only. Alternative designs meeting the intent of
these requirements are invited.
3. Structures are to be constructed in accordance with the BC
Building Code. Enclosures are to be designed to withstand snow
loading, vehicular damage, operational damage, and bears.
4. Roofs should be designed to avoid snow shed in front of service
and entry doors.
5. Service door(s) are to have dual locking mechanisms. Hinged
doors require a heavy-duty cane bolt at the bottom and a slide bolt at
the top of the stationary door. Roll-up doors require slide bolt locking
mechanisms on the bottom of the door, each side. All locking
mechanisms to be located on the interior; no hardware should be
located on the service door(s) exterior.
6. Steel entry door is to be 36" wide (915mm) and be equipped with a
self-closing mechanism. Door may have a round turning knob
complete with a covered keyed knob guard on the exterior for access
and panic hardware on interior for egress. Alternatively a push
button lock with a turning knob is acceptable.
7. Adequate motion activated interior and exterior lighting is to be
provided (if required).
8. Bear proof vent and steel entry door window openings should be
sized such that a bear could not gain access in the case of breakage.
9. Units in mm unless otherwise noted.
10. Roll-up doors are preferable in areas that may have ice and snow
build up but hinged doors are acceptable.
11. Separate enclosures for Commercial & Residential uses on the
same property are strongly recommended.
FRONT ELEVATION
Min. 600mm
Concrete Upstand
2%
100mm Reinforced
Concrete Slab on
Compacted Gravel Fill
SIDE ELEVATION
Heavy Duty
Commercial
Grade Roll-Up
or Hinged
Service Door
Min. 2900mm Clear
2400mm Clear
Optional Gable Roof
Optional Shed Roof
Edge of Reinforced
Concrete Slab
Hinged Doors
to Swing Open
180° Min.
Heavy Duty
Commercial Grade
Roll-Up or Hinged
Steel Doors are
Acceptable
3000mm Clear
As Required
200mm
As Required
Tote
RECYCLING TOTES & ORGANICS
Locking
Steel Entry
Door c\w
Optional
Reinforced
Window
PLAN VIEW
Floor Drain
to Sanitary (if
required)
Dimensions shown serve as a guideline only, the ultimate size and configuration of the
garbage enclosure will be dependant on the owners preference and services being provided.
Wildlife Resistant
Ventilation
LANDFILL
WASTE
Tote
Tote
Tote
Tote
Tote
Tote
Tote
Tote
Min. 1800mm
Locking Steel Entry Door c\w
Optional Reinforced Window
Thank you to RMOW for the
copy of the original design
drawings
Schedule C