411 Plumbing and Sewer Connection Bylaw - Consolidated
Ladysmith, British Columbia
This is the exact embedded text of the captured official document.
Snapshot f441764da89c · verified 2026-06-08 ·
original document ·
archived snapshot ·
unofficial consolidation, the official version is held by the municipal clerk.
Plumbing and Sewer Connection Bylaw 1996, No 411
Page 1
T O W N O F L A D Y S M I T H
"Plumbing and Sewer Connection Bylaw
1996, No. 411"
Consolidated Version as on March 26, 2019
(This consolidation is authorized by "Bylaw Revision Bylaw 2022, No. 2090")
________
Consolidated for Convenience Only
This consolidation is not a legal document. Certified copies of the original bylaws should be
consulted for all interpretations and applications of the bylaws of this subject
March 14, 1996
Includes Amendment Bylaw Nos.:491, 913, 1635, 2002
Plumbing and Sewer Connection Bylaw 1996, No 411
Page 2
TOWN OF LADYSMITH
BYLAW NO. 411
A bylaw to regulate connections to the sewers in the Town of
Ladysmith.
1. The Council of the Town of Ladysmith in open meeting assembled enacts as follows:
2.
(a) "TOWN" shall mean the Town of Ladysmith.
(b) "COMMON SEWER" shall mean any sewer line under the control of the Town
which was installed for public use.
(c) "SEWER CONNECTION" shall mean the sewer pipe extending from the
common sewer to the property line of the property served or to be served, or,
where the common sewer crosses the property which is to be served, shall mean
the tap-off provided from the common sewer for the purpose of serving the
property crossed.
(d) "BUILDING SEWER" shall mean the sewer pipe extending from the building
situated on the property and being connected to the plumbing system of the
building to the property line or, where the common sewer crosses the property, to
the tap-off provided for the building.
(e) "INSPECTOR" shall mean the Building Inspector of the Town of Ladysmith or
any official authorized by the Municipal Council to perform the duties of the
Building Inspector.
3. If a parcel of land, upon which there is located a building occupied by one or more
persons, abuts a street, lane or other public right of way under which there is laid a
common sewer, or if such parcel of land is crossed by a common sewer, the owner or
occupant of such building shall connect, or cause to be connected, such building with the
common sewer in the manner provided by this b:·law or any other pertinent bylaw of the
Town.
4.
a. Before any connection is made, the property owner or agent shall make application
for each desired connection to the Town of Ladysmith and pay the prescribed fees
for a:
i. Sanitary sewer main connection as shown in Schedule 'A' Section 1.
ii. Storm main connection as shown in Schedule 'A' Section 2.
Bylaw 2002
Plumbing and Sewer Connection Bylaw 1996, No 411
Page 3
b. Before a modification to an existing connection is made, the property owner or agent
shall make application to the Town of Ladysmith and pay the prescribed fees for a:
i. Sanitary sewer main modification connection as shown in Schedule 'A'
Section 3.
ii. Storm main modification connection as shown in Schedule 'A' Section 4.
5. Upon receipt of an application to connect to the Town sewer system and of the associated
fee required by Section 4 above, the Town shall provide a sewer connection extending
from the common sewer to the applicant's property line, following which the owner shall
connect his building sewer to the sewer connection provided in accordance with the
regulations hereinafter contained.
6. The sewer connection fee deposited in accordance with Section 4 above does not extend
to any works within the property of the applicant, except as to the inspection of the
applicants building sewer, and, where the common sewer crosses the applicants property,
the provision of the required tap-off for the building.
7. No person, other than the Town, its employees or agents, shall install or cause to be
installed any part of any sewer connection or tap-off, or in any way break, interfere, or
tamper with any common sewer of the Town.
8. If any owner or occupier of a. building or premises, which is required to be connected to
the common sewer pursuant to Section 3 of this bylaw, fails or-neglects to connect such
building or premises to the common sewer in the manner provided by·this bylaw, the
Town may serve on the Owner of the property a notice requiring such owner to comply
with all the provisions of' this bylaw, and to have completed within a period of six
months of the receipt of the notice the installation of his building sewer. The failure of an
owner to comply with the said notice shall constitute an infraction of this bylaw and the
owner sha11 be subject to the remedy provided in Section 9 next following AND to the
penalties provided in Section 21 of this bylaw.
9. Upon the expiration of the six month period referred to in Section 8 above, the Town may
enter upon the property of such owner and cause the connection to be made. The total
cost to the Town of making the connection, including the sewer connection fee and the
cost of installing the building sewer, shall be a special charge upon the land involved and
the amount of the charges shall be collected in the same manner and with the, like
remedies as ordinary taxes upon lands and improvements are collectable under the
Municipal Act.
10. Nothing in this bylaw shall be construed to permit the connection of a surface water drain
to the common sewer. The connection, either·directly or indirectly, of roof drains,
foundation drains, field drains, sumps or any other source of surface or ground water is
NOT permitted. The owner of any property who connects, permits or causes to be
connected any source or conductor of surface or ground water from the premises or
property to the common sewer shall be guilty of an infraction of this bylaw.
Plumbing and Sewer Connection Bylaw 1996, No 411
Page 4
11. No gasoline, naptha or other inflammable liquid or explosive substance, and no
automotive wastes, oil, lye, acids, mud, grit, plaster of paris, lime, clay or any other trade
or industrial waste which may injure or impair the efficiency or safety of any part of the
sewer system in any way shall be discharged into any common sewer within the Town.
12. In the event of an application being received for a sewer connection permit for a
commercial or industrial premises from which there exists a possibility that such noxious
wastes as are described in Section 11 of this bylaw may be discharged into the common
sewer, no connection shall be authorized until the Inspector has examined and approved
the installation of the necessary protective devices by means of which the applicant
proposes to prevent or neutralize the discharge of such noxious wastes into the common
sewer.
13. The minimum diameter of any building sewer or sewer connection shall be at least four
(4) inches.
14. Each lot must be separately and independently connected to the common sewer
15. All building sewers from houses and other buildings shall be installed by and at the cost
of the owner and shall be constructed of one of the following materials and manufactured
to meet C.S.A. requirements for such purpose:
1. Cast-iron sewer pipe, with approved gasket or ring type joint.
2. Asbestos-cement sewer pipe with approved gasket or ring type joint.
3. Vitrified clay .sewer pipe, with approved gasket or ring type joint.
4. Concrete sewer pipe, with approved gasket or ring type joint.
5. Plastic sewer pipe, with approved sealed joints.
6. Such other material as may frorn time to time be approved by the Town.
16.
a. A building sewer shall be laid to an even slope of not less than one-quarter of an
inch to the foot in the direction of flow.
b. A building sewer which is not subject to a traffic load shall have a minimum
cover of two feet of earth or a four inch casing of cement and a building sewer
which may be subject to any traffic load shall have a minimum cover of three feet
of earth or a four inch casing of cement or a four by twelve inch protective slab of
cement extending the width of the driveway laid over a six inch casing of temped
gravel.
c. Each building sewer pipe shall be laid concentric to each adjoining pipe and the
joints shall be flush, even, and free of any internal obstruction.
d. Where building sewer pipe couplings are provided by the manufacturer such
couplings shall be installed in accordance with the manufacturer's specifications.
e. In no cs.se shall cement mortar or oakum joints be permitted in a building sewer
pipe.
f. Bell and spigot building sewer pipe shall be laid with the spigot end facing the
direction of flow.
Plumbing and Sewer Connection Bylaw 1996, No 411
Page 5
g. The building sewer pipe trench shall be backfilled with selected material free of
rocks, wood, timber or any unyielding objects well tamped around underneath and
above the pipe.
17.
a. When the owner has completed the installation of the building sewer, but before
it has been backfilled, he shall inform the Inspector that the installation is
complete and the Inspector or his delegated officer shall forthwith make an
inspection of the work.
b. The Inspector may if he considers it necessary test the building sewer for
watertightness. A test shall be considered satisfactory if water escape does not
exceed one-quarter gallon per hour for each ten feet of building sewer.
c. The backfilling of the building sewer shall not be commenced until the Inspector
has signified in writing that the materials and workmanship employed are
satisfactory and that the provisions of this bylaw have been complied with.
d. The Inspector may enter any property at any reasonable time and inspect the
building sewer.
18. . Any materials or workmanship which, in the opinion of the Inspector, are defective, or
are otherwise not in compliance with the provisions of this bylaw, shall be removed and
replaced by the owner at the direction of the Inspector and the building sewer shall not be
backfilled unless and until such sewer has been approved as provided for in Section 17 of
this bylaw. Failure to replace materials or workmanship as provided in this section shall
be cause for the Town to proceed 1·rith the issuance of a notice as provided for in Section
8 of this bylaw, and the conditions imposed by Sections 8 and 9 hereof shall apply.
19. The Town may require anyone to fill in a septic tank on his property, or otherwise deal
with it as deemed advisable, following the connection of the building sewer to the
common sewer.
20. The requirements of Part 7 of the National Building Code, 1960, shall apply to all
building sewer installations and connections made to the common sewer, together with
the provisions as set forth heretofore, and wherever there may be a conflict between the
National Building Code and the provisions set out heretofore the provisions of this bylaw
shall prevail.
21. Every person who offends against any· of the provisions of this bylaw, or who suffers or
permits any act or thing to be done in contravention or violation of any of the provisions
of this bylaw, or neglects to do or refrains from doing anything required to be done under
this bylaw, or who doss any act or thing which violates any of the provisions of this
bylaw; sha11 be deemed to have committed an offence under this bylaw and shall be
liable upon summary conviction to a fine not exceeding, one hundred ($100.00) dollars.
22. This bylaw may be cited as the "Town of Ladysmith Sewer Connection Bylaw, 1966".
23. The following bylaw is hereby repealed:
Plumbing and Sewer Connecting Bylaw, 1941, No. 231
Plumbing and Sewer Connection Bylaw 1996, No 411
Page 6
READ A FIRST TIME on the
14th
day of
March,
l966.
READ A SECOND TIME on the
14th
day of
March,
l966.
READ A THIRD TIME on the
14th
day of
March,
l966.
RECONSIDERED, FINALLY PASSED and ADOPTED on the
28th
day
of
March,
l966.
_________________________________
Mayor
_________________________________
Clerk
I hereby declare this to be a true
and correct copy of Bylaw No.411
of the Town of Ladysmith.
_________________________________
Plumbing and Sewer Connection Bylaw 1996, No 411
Page 1
Town of Ladysmith Sewer Connection Bylaw, 1966 No. 411, Amendment Bylaw 2019, No.
2002.
Schedule 'A'
1. Sanitary Sewer Main Connection Fee
Diameter
Length
Depth
Cost per
connectio
n
Up to 100mm (4")
Up to 20 meters
Up to 3 meters
$2,000
Any variation to the sanitary sewer main diameter, length or depth will be charge at cost with a
minimum fee of $2,000 per connection.
2. Storm Main Connection
Diameter
Length
Depth
Cost per
connectio
n
Up to 100mm (4")
Up to 20 meters
Up to 3 meters
$3,800
Any variation to the storm main diameter, length or depth will be charge at cost with a minimum fee
of $3,800 per connection.
3. Sanitary Sewer Main Modification Connection Fee
At cost with a minimum fee of $2,000 per connection.
4. Storm Main Modification Connection Fee
At cost with a minimum fee of $3,800 per connection.