Subdivision and Development Control Bylaw No. 1201, 2014
9
Schedule 'A' - District of Tofino - Road Cross-Sections
Subdivision and Development Control Bylaw No. 1201, 2014
Refer to Map 7 "Road Typologies" in the Official Community Plan for road designation.
A1 - Primary Arterial
A2 - Gateway Arterial
A3 - Downtown Arterial
C1 - Downtown Collector
C2 - Village Collector
C3 - Industrial Collector
C4 - Recreational Access Collector
C5 - Residential Collector
L1 - Downtown Local (Not Included)
L2 - Village Local
L3 - Residential Local
L4 - Village Rear Lane Local
L5 - Cul-De-Sac Local
DISTRICT
OF TOFINO
SUBDIVISION &
DEVELOPMENT
CONTROL BYLAW
All Dimensions Shown in Metres,
Unless Otherwise Noted
A1 PRIMARY ARTERIAL
STREET SECTION
Revision Date
Approved
1
2
3
Approved
Date
Drawn By
McElhanney
JAN 2014
DRAWING NUMBER
A1
Title
Reference:
BC Ministry of Transportation and Infrastructure - Supplement to TAC Geometric Design Guide
Figure 440.A Typical Section - Rural Local Undivided
DISTRICT
OF TOFINO
SUBDIVISION &
DEVELOPMENT
CONTROL BYLAW
All Dimensions Shown in Metres,
Unless Otherwise Noted
A2 GATEWAY ARTERIAL
STREET SECTION (Page 1 of 2)
Revision Date
Approved
1
2
3
Approved
Date
Drawn By
Bunt & Associates
November 2011
DRAWING NUMBER
A2.1
Title
DISTRICT
OF TOFINO
SUBDIVISION &
DEVELOPMENT
CONTROL BYLAW
All Dimensions Shown in Metres,
Unless Otherwise Noted
A2 GATEWAY ARTERIAL
STREET SECTION (Page 2 of 2)
Revision Date
Approved
1
2
3
Approved
Date
Drawn By
Bunt & Associates
November 2011
DRAWING NUMBER
A2.2
Title
DISTRICT
OF TOFINO
SUBDIVISION &
DEVELOPMENT
CONTROL BYLAW
All Dimensions Shown in Metres,
Unless Otherwise Noted
C2 VILLAGE COLLECTOR
STREET SECTIONS
Revision Date
Approved
1
2
3
Approved
Date
Drawn By
Bunt & Associates
November 2011
DRAWING NUMBER
C2
Title
DISTRICT
OF TOFINO
SUBDIVISION &
DEVELOPMENT
CONTROL BYLAW
All Dimensions Shown in Metres,
Unless Otherwise Noted
C3 INDUSTRIAL COLLECTOR
STREET SECTION
Revision Date
Approved
1
2
3
Approved
Date
Drawn By
Bunt & Associates
November 2011
DRAWING NUMBER
C3
Title
DISTRICT
OF TOFINO
SUBDIVISION &
DEVELOPMENT
CONTROL BYLAW
All Dimensions Shown in Metres,
Unless Otherwise Noted
C4 RECREATIONAL ACCESS COLLECTOR
STREET SECTION
Revision Date
Approved
1
2
3
Approved
Date
Drawn By
Bunt & Associates
November 2011
DRAWING NUMBER
C4
Title
DISTRICT
OF TOFINO
SUBDIVISION &
DEVELOPMENT
CONTROL BYLAW
All Dimensions Shown in Metres,
Unless Otherwise Noted
C5 RESIDENTIAL COLLECTOR
STREET SECTIONS
Revision Date
Approved
1
2
3
Approved
Date
Drawn By
Bunt & Associates
November 2011
DRAWING NUMBER
C5
Title
DISTRICT
OF TOFINO
SUBDIVISION &
DEVELOPMENT
CONTROL BYLAW
All Dimensions Shown in Metres,
Unless Otherwise Noted
L2 VILLAGE LOCAL
STREET SECTION
Revision Date
Approved
1
2
3
Approved
Date
Drawn By
Bunt & Associates
November 2011
DRAWING NUMBER
L2
Title
DISTRICT
OF TOFINO
SUBDIVISION &
DEVELOPMENT
CONTROL BYLAW
All Dimensions Shown in Metres,
Unless Otherwise Noted
L3 RESIDENTIAL LOCAL
STREET SECTION
Revision Date
Approved
1
2
3
Approved
Date
Drawn By
Bunt & Associates
November 2011
DRAWING NUMBER
L3
Title
DISTRICT
OF TOFINO
SUBDIVISION &
DEVELOPMENT
CONTROL BYLAW
All Dimensions Shown in Metres,
Unless Otherwise Noted
L5 CUL-DE-SAC LOCAL
STREET SECTION
Revision Date
Approved
1
2
3
Approved
Date
Drawn By
Bunt & Associates
November 2011
DRAWING NUMBER
L5
Title
Subdivision and Development Control Bylaw No. 1201, 2014
11
Schedule 'B' - District of Tofino - Approved Products List
Subdivision and Development Control Bylaw No. 1201, 2014
DISTRICT OF TOFINO APPROVED UTILITY PRODUCT LIST
BYLAW NO. 1201, 2014 - SCHEDULE B
1 of 7
Division
Item
Type
Size
Standards
Approved Products
Comments
Date Approved
Waterworks
Fire Hydrants
Compression
with lugs for tie
rods
150mm inlet
AWWA C502-94 (143.75mm
outside dia 4 threads per 25mm)
Terminal City C71P
AVK #2780
Paint Red with white port caps- contact Fire
Department for thread sizes and diameters -
counter clockwise opening
10-Nov-15
Waterworks
Pipe
PVC
75mm to 300mm
DR25/18/14 Class
100/150
AWWA C900/C905 CSA 137.3
IPEX or J-M "Blue Brut" (100mm to 1200mm)
Royal Pipe Systems (100mm to 450mm)
Rehau Aqualoc
Northern Pipe (100mm to 762mm)
10-Nov-15
Waterworks
Tracer Wire
RWU 90
10 Gauge (AWG)
XLPE insulation for direct burial applications
10-Nov-15
Waterworks
Pipe
Ductile Iron
AWWA C151
10-Nov-15
Waterworks
Pipe
Steel
AWWA C200
10-Nov-15
Waterworks
Service
Connection Pipe
HDPE C/W
tracer wire laid in
trench
19mm to 50mm
AWWA C901-22, pressure class
160, 200 CSA B137.1
Tracer wire laid in trench, must be visible in
meter and BFP box
10-Nov-15
Waterworks
Pipe fittings: 90,
45, 22.5, crosses,
tees, wyes,
reducers
Cast Iron Ductile
Iron Compact
Ductile Iron
to 1035 Kpa to 2415
Kpa to 2415 Kpa
AWWA C110
AWWA C110
AWWA C153
Must be stamped with AWWA standards
10-Nov-15
Waterworks
Pipe Joint
Protection
As Required
Canus "JointWrap" cold applied pipe joint
sleeve or equal
10-Nov-15
Waterworks
Corporation Stops
Compression
Type
19mm to 50mm
AWWA C800 1035 Kpa
Mueller H-15008
Ford F-1000
Cambridge E-17072, series 102
to 75mm with Superintendent of Road Works
approval only
10-Nov-15
Waterworks
Curb Stops
19mm to 50mm
ASTM B62 Full flow, full port Mueller H-110
Ford BH44-233
Cambridge series 103
10-Nov-15
Waterworks
Service Saddles
Ductile Iron Pipe Service to 75mm
Double strap
AWWA C800, C210, C213, C111
Robar 2408DS
Canpac CD-2
Robar 2506DS
Canpac CDES-2
10-Nov-15
Waterworks
Pipe
HDPE
100mm to 300mm
PE 4710, PE3408, C906-12
Sclair - KWH
10-Nov-15
DISTRICT OF TOFINO APPROVED UTILITY PRODUCT LIST
BYLAW NO. 1201, 2014 - SCHEDULE B
2 of 7
Division
Item
Type
Size
Standards
Approved Products
Comments
Date Approved
Waterworks
Service Saddles
PVC Pipe
Service to 75mm
Double strap
AWWA C800, C210, C213, C111
ASTM (A536)
Robar 2406DS, 27-6DS, 2506DS, 2606DB
Smith-Blair 317, 357
Canpac SC-1, SC-2
10-Nov-15
Waterworks
Abandon Service
Sleeves
150mm to 600mm
Mains and 19mm or
25mm Services
NCT 304 SS Const.
Robar 6636 AS
10-Nov-15
Waterworks
Tapping Sleeves
Ductile/PVC
Pipe
75mm and larger
AWWA C900
ASTM (A283)
Robar 6606, 6906, 6506
Romac SST, FTS
Smith-Blair 622, 662
10-Nov-15
Waterworks
Repair Clamps
Double bolted
with or without
tapped outlets
100 to 350mm dia
200 to 600mm
lengths
Gasket to ASTM D2000
Robar 5626
Canpac Style CR2
10-Nov-15
Waterworks
Couplings
AWWA C219, C213, C210, C550,
ASTM (A536)
Gaskets ASTM
D2000 endplates ASTM A536
centre ring ASTM
A536 bolts/nuts
AWWA C111
Robar 1408, 1506
Robar 1726 Multi Range
Hymax 2000
Romac Macro HP
Smith-Blair #441
10-Nov-15
Waterworks
Flanged Coupling
Adapters
AWWA C219, C213, C210, C550,
ASTM (A536)
Gaskets ASTM
D2000 endplates ASTM A536
centre ring ASTM
A536 bolts/nuts
AWWA C111
Robar 7404
Romac FCA 501
Smith-Blair #912
10-Nov-15
Waterworks
Restrainers
Ductile
PVC
PVC (bell joint)
100mm to 300mm
AWWA C219, C210, C213, C550
C900 DR 18
Uni Flange series 1300 (PVC)
Uni Flange 1350,1390 (PVC)
Uni Flange 1400 (DI)
Robar 4400
Robar 4450, 4452
EBAA IRON Series 3800
EBAA IRON 1506TD
Royal Pipe Cobra Lock
10-Nov-15
Waterworks
Gate Valves
Resilient seated
100mm to 300mm
AWWA C509
Clow F-6100
Mueller A-2370
AVK 03, 25/45
Counterclockwise-confirm with
Superintendant
10-Nov-15
Waterworks
Butterfly Valves
AWWA C504 class 150B
As per contract drawings
10-Nov-15
Waterworks
Valve Boxes
Mainline
Circular
Terminal City "Maple Ridge"
MR
Victoria Foundary "Robar"
Use TC "NT" in non-paved areas
10-Nov-15
DISTRICT OF TOFINO APPROVED UTILITY PRODUCT LIST
BYLAW NO. 1201, 2014 - SCHEDULE B
3 of 7
Division
Item
Type
Size
Standards
Approved Products
Comments
Date Approved
Waterworks
Service Boxes
Curb Stop
Circular
Terminal City "NCR"
Alf's Flat Tops
10-Nov-15
Waterworks
Vaults
Pressure
Reducing Valve
Chamber
As per specifications
Lombard Precast
Hyland Precast
AE Concrete
10-Nov-15
Waterworks
Water Meter
19mm and 25mm
Elster SM700
Itron 60w ERT prewired to meter
Pit style must use lid mount pit antennae and
compatible lid.
10-Nov-15
Waterworks
Water Meter
Larger than 75 mm
Aquamaster
Itron 60w ERT prewired to meter
10-Nov-15
Waterworks
Water Meter
Up to 75mm
Aquamaster
Itron 60w ERT prewired to meter
10-Nov-15
Waterworks
Setter Idler
Brass or
Cambridge P/N
15mm to 25mm
450 Series (1-4)
10-Nov-15
Waterworks
Setter Idler
Cambridge
38mm to 50mm
450 Series (5-6)
10-Nov-15
Waterworks
Setter
Coppersetter
15.625 to 25mm
NSF-61
Mueller
Ford
Cambridge Brass
Full Flow - Dual Check with relief screw
10-Nov-15
Waterworks
Meter Boxes
Concrete
(Brooks Box)
H-20 Loading
A.E. Concrete
Full perimeter recess
10-Nov-15
Waterworks
Meter Box Lid
Cast Iron
(Brooks Box)
H-20 Loading
Terminal City
Solid Lid Stamped with Water Meter
No Recess for radio read.
10-Nov-15
Waterworks
Service Stub
Restrainer
Stainless Steel
Robar
Capping bracket for covering a corp stop at
the main in an AC concrete pipe - When
abandoning service
10-Nov-15
Sanitary
Pipe
PVC smooth
100mm to 475mm
ASTM D3034
CSA.B182.2, 100, 150mm DR28,
200mm DR35
Royal Pipe Systems Ipex or J-M "Ring-Tite"
Rahau Abondloc Northern Pipe
10-Nov-15
DISTRICT OF TOFINO APPROVED UTILITY PRODUCT LIST
BYLAW NO. 1201, 2014 - SCHEDULE B
4 of 7
Division
Item
Type
Size
Standards
Approved Products
Comments
Date Approved
Sanitary
Pipe
PVC smooth
200mm to 375mm
ASTM D3034, CSA 182.2 100,
150mm DR 28 > 200mm DR 35
Royal Pipe Systems
Ipex "Ring-Tite"
Rauhau Abondloc
Northern Pipe
J-M Manufacturing
10-Nov-15
Sanitary
Pipe
Ribbed extruded
seamless
450mm to 900mm
CSA B182.4 ASTM F794-89,
D2412
Kor Flo (450mm - 900mm)
Ipex "Ultra-Rib" (450mm-600mm) Rahau
ARauRib (375mm-450mm)
10-Nov-15
Sanitary
Pipe Connectors
Rubber
Couplings
Stamped CSA Approved
10-Nov-15
Sanitary
Tees
Inserta Tee
100mm to 300mm
MMCD 33 30 01 pg 8 - 3.10.1
Detail dwg S7
Royal Pipe Systems
Galaxy Plastics Ltd. "EZ Tee"
Post-main construction only - Inserta tees will
not be permitted for new construction.
Maximum service size to be at least 2 pipe
sizes less than main.
10-Nov-15
Sanitary
Pipe Fittings:
Wyes, bends,
reducers
PVC smooth
CSA B182.2 182.2 ASTM D3034
10-Nov-15
Sanitary
Pipe Fittings:
Wyes, bends,
reducers
PVC smooth
200mm to 375mm
ASTM D3034, CSA 182.2 100,
150mm DR 28 > 200mm DR 35
10-Nov-15
Sanitary
Inspection
Chambers
Add A Flap
Adapt A Valve
100mm to 150mm
MMCD 33 30 01
pg 8 - 3.10.3
Royal Pipe Systems
Pro-Line Fittings
c/w red (colour coded) lid
10-Nov-15
Sanitary
Manhole
Frame and
Cover
H20 Loading
ASTM A48
Terminal City
Westview Sales
10-Nov-15
Sanitary
Manholes
Adjustable
Frame and
Cover
C-18
H20 Loading
Terminal City
Westview Sales
Must use never-seize and protective
covering on adjustable bolts
10-Nov-15
Sanitary
Manhole
Pre cast
sections
ASTM C478M
As per manhole specifications
Lombard Precast
Hyland Precast
Langley Precast
10-Nov-15
Sanitary
Manhole Base
Pre Bench
ASTM C478M
As per manhole specifications
Lombard Precast
Hyland Precast
Langley Precast
10-Nov-15
Sanitary
Manholes
Adjusting Rings
HDPE - H20 Loading
Ipex Life Saver Manhole Adjusting Rings
Must use SIKAFLEX adhesive
10-Nov-15
DISTRICT OF TOFINO APPROVED UTILITY PRODUCT LIST
BYLAW NO. 1201, 2014 - SCHEDULE B
5 of 7
Division
Item
Type
Size
Standards
Approved Products
Comments
Date Approved
Sanitary
Gate Valves
AVK
Iron body, resilient seated, stainless steel
stem, 50 mm operating nut
10-Nov-15
Sanitary
Ball Check Valve
AVK Series 53/3x
Iron body, resilient seated, ball check
10-Nov-15
Storm
Pipe
Concrete
<675mm
Non-reinforced circular concrete
pipe and fittings to ASTM C14M
designed for flexible rubber gasket
joints to ASTM C443M
Lombard Precast
Hyland Precast
Langley Precast
10-Nov-15
Storm
Pipe
Concrete
>675mm
Reinforced circular concrete pipe
and fittings to ASTM C76M
designed for flexible rubber gasket
joints to ASTM C443M
Lombard Precast
Hyland Precast
Langley Precast
10-Nov-15
Storm
Pipe
PVC smooth
200mm to 375mm
ASTM D3034, CSA 182.2 100,
150mm DR 28 > 200mm DR 35
Royal Pipe Systems
Ipex "Ring-Tite"
Rauhau Abondloc
Northern Pipe
J-M Manufacturing
10-Nov-15
Storm
Pipe
PVC ribbed
diagonal
750mm and 900mm
CSA B182.4 ASTM F794 Class 5,
ASTM D2412
Ipex "Perma-Loc"
Royal Pipe Systems
10-Nov-15
Storm
Pipe
PVC ribbed
extruded
seamless
200mm to 900mm
CSA B182.4 ASTM F794-89,
D2412
Kor Flo 450mm-900mm)
Ipex Ultra-Rib (450mm-600mm) Rehau
ArauRib (450mm)
10-Nov-15
Storm
Pipe
Corrugated steel
pipe
>900mm
CSA G401-93
10-Nov-15
Storm
Culverts
Corrugated steel
pipe HDPE
>=300mm
CAN G401 CSA B 182.8
Boss 2000
Armtec
10-Nov-15
Storm
Tees
Inserta Tee
100m to 300mm
MMCD 33 40 01
pg 9 - 3.10.1 Detail dwg S8
Royal Pipe Systems
Galaxy Plastics Ltd. "EZ Tee"
Maximum service size to be at least 2 pipe
sizes less than main.
10-Nov-15
Storm
Pipe Fittings:
Wyes, bends,
reducers
PVC smooth
CSA B182.1 182.2 ASTM D3034
Royal Pipe Systems
Ipex
10-Nov-15
Storm
Pipe Fittings:
Wyes, bends,
reducers
PVC rib to
ribbed
375mm plus
ASTM F794 CSA B182.4
Royal Pipe Systems
Ipex
10-Nov-15
DISTRICT OF TOFINO APPROVED UTILITY PRODUCT LIST
BYLAW NO. 1201, 2014 - SCHEDULE B
6 of 7
Division
Item
Type
Size
Standards
Approved Products
Comments
Date Approved
Storm
Inspection
Chambers
Add A Flap
Adapt A Valve
150mm
MMCD 33 40 01
pg 9 - 3.10.3
Royal Pipe Systems
Pro-Line Fittings
10-Nov-15
Storm
Manhole
Frame and
Cover
H20 Loading
Terminal City
10-Nov-15
Storm
Manholes
Adjustable
Frame and
Cover
C-18
H20 Loading
Terminal City
Westview Sales
Must use never-seize and protective
covering on adjustable bolts
10-Nov-15
Storm
Manholes
Precast sections
ASTM C478M
As per manhole specifications
Lombard Precast
Hyland Precast
Langley Precast
10-Nov-15
Storm
Manholes
Adjusting Rings
HDPE - H20 Loading
Ipex Life saver Manhole Adjusting Rings
Must use SIKAFLEX adhesive
10-Nov-15
Storm
Manhole Base
Pre Bench
ASTM C478
Lombard Precast
Hyland Precast
Langley Precast
10-Nov-15
Storm
Catchbasin
Frame and
Grate
Rectangular
ASTM A48
H20 Loading
Terminal City
Westview Sales
10-Nov-15
Storm
Catchbasin
With curb inlet
Rectangular
ASTM A48
H20 Loading
Terminal City
Westview Sales
10-Nov-15
Storm
Catchbasin
Precast concrete
ASTM C478M, leads 200mm dia,
DR35
As per Standard Detail Drawings
10-Nov-15
Storm
Catchbasin
Adjusting Rings
HDPE - H20 Loading
Ipex Life Saver Manhole Adjusting Rings
Must use SIKAFLEX adhesive
10-Nov-15
Storm
Headwall
Premanufactu
red (Concrete or
Composite)
Pipe size of 200mm
to 1200mm
Custom Industrial Fibreglass Ltd. PRO-ECO-
LITE
Lombard Pre Cast Inc.
Provide grates on all storm drain inlets and
outlets over 375mm or over 300mm.
10-Nov-15
Storm
Manufactured
Oil/Sediment Trap
Unit
In Precast
Manhole
Lid and Manholes H20 Loading
Stormceptor
Contech Vortechs VortSentry
Size in accordance with specifications
10-Nov-15
DISTRICT OF TOFINO APPROVED UTILITY PRODUCT LIST
BYLAW NO. 1201, 2014 - SCHEDULE B
7 of 7
Division
Item
Type
Size
Standards
Approved Products
Comments
Date Approved
Storm
Open Drain
PVC
100mm to 200mm
NDS Pro Series
PVC grate in Blvd application H-20 loading
grate in road application
10-Nov-15
Street Lighting
As per MMCD
As per MMCD
10-Nov-15
Signs
Round Post Break-
out Coupler and
Anchor Extension
(Break Away Base)
To fit Galvanized
Round Pole
50mm
12G
Inprotect - Anchor adapter part # HDAAA and
complete top part # BOR 238-1316
Or
Break-out 2-3/8" round post coupler - complete
part # BOR 238-1012
To be used when pole is to be placed in a
finished concrete or asphalt surface
10-Nov-15
Signs
Post Mounting
Hardware
Round
50mm
HS-1
10-Nov-15
Signs
Stop Sign Blades
600mm x 600 mm stop signs for local roads.
750mm x 750mm stop signs for arterial and
collector roads
All stop signs to be Diamond Grade
10-Nov-15
Signs
All Other Sign
Blades
All signs to conform to BC Min of
Transportation and/or TAC
10-Nov-15
Landscaping
Retaining Walls
Lock + Load
A.E. Concrete Precast Products
10-Nov-15
Landscaping
Retaining Walls
Allen Block
Allan Block Corp.
10-Nov-15
Subdivision and Development Control Bylaw No. 1201, 2014
13
Schedule 'C' - MMCD - Design Guideline Manual - 2014 Edition (Bound Separately)
Subdivision and Development Control Bylaw No. 1201, 2014
THIS PAGE IS INTENTIONALLY LEFT BLANK
Subdivision and Development Control Bylaw No. 1201, 2014
14
Schedule 'D' - MMCD - Volume II Platinum Edition (Bound Separately)
Subdivision and Development Control Bylaw No. 1201, 2014
THIS PAGE IS INTENTIONALLY LEFT BLANK
Schedule 'E' - District of Tofino - Supplementary Design Guidelines
Subdivision and Development Control Bylaw No. 1201, 2014
1.
GENERAL DESIGN CONSIDERATIONS AND DRAFTING STANDARDS
1.1.
Subdivision design to include coordination of Independent Utility design for works within
the roads and/or municipal rights of way as required to service the lots created. The
Developer, or his Authorized Agent, shall ensure that the design of those works is
integrated with the design of other works required under this bylaw. These Independent
Utilities shall include, but may not be limited to the following:
INDEPENDENT UTILITIES
-
BC Hydro electrical power distribution;
-
Telus telephone and communications; and,
-
Shaw Cable communications.
Independent Utilities to be carried in an underground duct system.
1.2
The Developer is responsible to provide all rights-of-way required for construction of
both municipal and independent utilities required to service the lots created. This
requirement is not limited to the subject parcels and may include rights-of-way across
neighbouring properties.
UTILITY RIGHTS-OF-WAY
2.1
This section shall govern the preparation of engineering drawings associated with
development approval and the Municipal works and services.
SCOPE
2.2
A complete set of construction drawings shall consist of separate drawings of some or all
of the following:
GENERAL REQUIREMENTS
(a)
Site plan and key plan
(b)
Drainage area plan
(c)
Plan and profile for roads, drainage and storm sewers
(d)
Plan and profile for sanitary sewers and watermains
(e)
Plan and profile for sanitary and storm sewers for common trench designs
(f)
Plans of proposed street lighting, hydro, telephone and cablevision
(g)
Additional plans showing any special details and cross-sections
(h)
Landscaping plans as required by Tofino
2.2.1 Maximum drawing size shall be 610 mm x 915 mm (24" x 36").
2.2.2 Drawings shall be prepared by utilizing computer drafting methods. The MMCD
drawing template shall be utilized.
2.2.3 Drawing scales and dimensions shall be shown. To facilitate scaling, graphical
scales shall be indicated on all reproducible drawings. All drawings shall be
metric.
2.2.4 In all cases, lettering shall be done with sufficient care to permit clear, one-half
size reduction.
2.2.5 The drawings shall be neat and legible and they shall clearly locate and describe
the work in sufficient detail to facilitate construction, with clearly defined limits of
construction.
2.2.6 Plan profile drawings shall be drawn with the profile on the bottom of the drawing
sheet.
2.2.7 Standard drafting procedures shall be used for dimensioning, arrowheads, line
densities, etc. Lettering shall be to Leroy metric heights and widths with the
minimum height of lettering being 2 mm to 2.5 mm. Vertical upper case lettering
is preferred. Conflicts between line work, symbols, dimensions or text shall be
removed.
2.2.8 All elevations shown on drawings shall be metric geodetic datum NAD 83 and the
source and location of datum shall be clearly noted on each drawing.
2.2.9 Drawing title block shall include the project name, project location, type of
drawing (i.e. Site Plan) and Engineer's name and/or company name and logo,
address, phone number and email address.
2.2.10 Plan and Profile drawings shall be to the following scales unless otherwise
approved:
Horizontal
1:500 or 1:250
Vertical
1:50
2.2.11 The following notes shall be shown on either the site plan or the first drawing of
the set:
(a) "All work and materials are to be as described in the District of Tofino 'Design
Guidelines and Specifications,' or as otherwise approved by the
Superintendent."
(b) "Connection to, or alteration of, existing District-owned utilities, will be
undertaken by District of Tofino forces only, unless otherwise authorized by
the Superintendent."
(c) "A 'Construction Permit to Install Works Within Streets, Lanes and Tofino
Property Areas', will be required where construction is to be undertaken in
District of Tofino rights-of-way and/or on District of Tofino-owned utilities or
properties."
(d) "Upon approval of the permit, the Superintendent shall be notified forty-eight
(48) hours prior to commencement of work."
2.2.12 Standard details such as manholes, catch basins, hydrants, etc., that are shown
and described in the District of Tofino Standard Detailed Drawings need not be
shown in detail on the drawings. Standard symbols for the various facilities as
shown on Standard Drawings detailing Standard Symbols and Abbreviations
shall be used and shown in a legend on all drawings.
2.2.13 All drawings shall bear the date stamp/seal and signature of the professional
engineer responsible for the design.
2.2.14 Provision shall be made on all drawings for the insertion of the District of Tofino
as-built file number in the lower right-hand corner of the drawing sheet. The
space provided shall be a minimum ten (10) mm high by fifty (50) mm long.
2.2.15 Numerical values shown on the construction drawings shall reflect the decimal
precision of the numbers. Generally numbers shall be shown to two (2) decimals
unless accuracy warrants otherwise.
2.2.16 All elevations shown on drawings shall be metric geodetic datum. The source
and location shall be clearly noted on each drawing.
2.2.17 All digital drawings submitted to the District must be in either DXF or DWG
format, and the site shall be located on NAD83 (CSRS) coordinates.
2.3
2.3.1 The Site Plan of the construction works shall be to a scale of not less than
1:1000.
SITE PLAN AND KEY PLAN
2.3.2 The following existing and proposed information shall be shown on the Site Plan:
(a) Existing watercourses and setbacks
(b) Pavement, curbs
(c) Ditches, culverts, storm sewers, manhole cleanouts, inlet/outlet structures
and catch basins
(d) Sanitary sewers, manholes, cleanouts
(e) Watermains, valves, hydrants, prvs, air valves, flush outs
(f) All pertinent property, right-of-way and easement lines
(g) Road allowance and easement dimensions
(h) Lot numbers and existing legal plan numbers and addresses where
applicable
(i) One-metre contour lines
(j) Plan and profile drawing reference numbers
(k) Underground hydro, telephone, streetlights and cable and their related
appurtenances
(l) Survey control monuments
(m) Traffic control devices, poles, conduits, signs and painting
(n) Routing of all major storm flows including the 100 year storm
(o) Approved street name from the District
2.3.3 A Key Plan to a small scale (e.g. 1:10,000), showing the location of the works in
relation to major streets, shall be provided in the upper right-hand section of the
drawing sheet.
2.3.4 A drawing index shall be provided and include the drawing titles, drawing
numbers and provision for the District of Tofino as-built field number.
2.4
2.4.1 A drainage area plan (with a 1:500 to 1:2500 scale) must accompany storm
drainage calculations for a subdivision or development. The plan shall include
the following information:
DRAINAGE AREA PLAN
(a) Onsite and offsite drainage areas
(b) Existing and proposed drainage systems
(c) The 100 year storm flood routing
(d) Contours
(e) Existing and proposed road and lot layout
(f) Existing and proposed drainage areas
(g) Separate coloured existing and proposed drainage area plans where required
for clarity
2.5
2.5.1 The Superintendent may require site and lot grading plans in areas where
driveway grades, drainage outlets, servicing elevations, etc. may have a critical
impact on the development of the lot.
SITE AND LOT GRADING PLAN
2.5.2 The scale shall be 1:500 or 1:250.
2.5.3 The plans shall include the following information:
(a) Existing ground elevations of lot corners and proposed building site. Include
the location and depth of any fill areas.
(b) Location and invert elevations for storm and sanitary services
(c) Location of water service
(d) Minimum building elevation (MBE) and critical finished landscape elevations
(e) Direction of surface drainage and location of drainage swales, ditches and
catch basins
(f) Proposed driveway locations and grades
(g) Applicable information required under MMCD Design Guidelines Manual -
Storm Drainage
2.6
Each base plan and profile shall show, but not be limited to, the following information:
PLAN AND PROFILE DRAWINGS - GENERAL
2.6.1 All cadastral information including property, right of way and easement lines and
dimensions in sufficient detail to relate design to surrounding and adjacent
properties
2.6.2 Legal description of properties
2.6.3 Road allowance dimensions
2.6.4 Existing pavement, curbs, sidewalks, ditches, driveways, lanes, retaining walls,
buildings, trees and shrubs, etc., within right-of-way, and beyond the rights of
way as required
2.6.5 Street addresses of existing buildings
2.6.6 Approved street name from District
2.6.7 Existing underground and surface utilities and services with offsets including, but
not limited to, the following:
(a)
Sanitary sewers, storm sewers, watermains and appurtenances
(b)
Street light poles, conduit and appurtenances
(c)
B.C. Hydro poles and underground wiring ducts and appurtenances
(d)
Telus poles and underground wiring ducts and appurtenances
(e)
Cablevision ducts and appurtenances
(f)
Traffic control devices, conduits, signs and painting
2.6.8 All relevant topographic information including one (1) metre contour lines.
Provide spot elevations and closer intervals on flat ground.
2.6.9 Plan and profile drawing reference number.
2.6.10 Benchmark elevation, identification number and location shall be shown in the
notes section of each drawing.
2.6.11 Right-of-way and/or road centerline stationing to metric standards (0+000) at
20-metre intervals and shall be related geometrically to legal property lines or
survey monuments.
2.6.12 Where possible, plan views shall be horizontal across the drawing sheet and
shall be aligned vertically by centre-line stationing with the profile view.
2.7
The following shall be shown in addition to the information required in section 2.6:
ROADS
2.7.1 All proposed roadworks, complete with existing elevation tie-in points and offsets
from road centerline, including: pavement, curbs, sidewalks and poles.
2.7.2 All proposed roadworks including pavement, curbs, sidewalks, traffic control
devices, poles, signs and painting, complete with offsets from road centre line.
2.7.3 Stations of the BC and EC of road centerline and curb return horizontal curbs
together with the curve information including delta angle, centerline radius,
tangent length and centerline arc length.
2.7.4 Details of intersections with spot elevations at all critical points including grades
and elevations of curb returns.
2.7.5 Catch basin rim elevations and stations related to road centerline chainage.
2.7.6 Existing ground profile and finished pavement profile along the pavement
centerline with elevations at 10 metre intervals. Existing ground profile to extend
minimum 50 m beyond the end of the proposed work unless otherwise approved
by the Superintendent.
2.7.7 Cross fall or crown information with gutter elevations at change points.
2.7.8 Proposed road centerline grade.
2.7.9 Stations and elevations of BVC, EVC and VPI.
2.7.10 Vertical curve information including the length of curve and sag or crest K value,
where K equals the length of the vertical curve in metres divided by the algebraic
difference in grades, percent.
2.7.11 Elevations along the vertical curve at ten (10) metre intervals.
2.7.12 Elevation and station of low and high spots of vertical curves.
2.7.13 Where the slope of existing ground is greater than 10% across the right-of-way,
cross-sections shall be shown at intervals not exceeding twenty (20) metres
(where required by the Superintendent).
2.7.14 Typical road cross-section showing right-of-way, pavement width, sidewalks,
curbs, underground utilities, hydro, power and street light poles, hydrants and
their related offsets.
2.7.15 Proposed monument locations.
2.7.16 Additional design details as required.
2.8
The following shall be shown in addition to the information required in section 2.6:
STORM AND SANITARY SEWERS
2.8.1 All proposed storm and sanitary works including manholes, drop pipes,
cleanouts, catch basins, inlet/outlet structures, pipe work, ditches, culverts and
wyes, and pipe inverts.
2.8.2 Existing ground profile and finished ground or pavement profile along the
centerline of the proposed sewer.
2.8.3 Distance between manholes with proposed grade.
2.8.4 Stations and elevations of the BC and EC of all horizontal curves with the curve
information including delta angle, radius, tangent length and arc length.
2.8.5 Stations and elevations of BVC, EVC and VPI.
2.8.6 Vertical curve information including the length of vertical and maximum pipe
deflection.
2.8.7 Elevations along vertical curves at ten (10) metre intervals.
2.8.8 Size, type and class of pipe.
2.8.9 Existing or proposed pipe crossings to be shown in profile.
2.8.10 Proposed inverts and offset locations to property line of service connections at
property lines.
2.8.11 Location of existing buildings on properties served by storm and sanitary sewers.
2.8.12 Invert of existing sanitary and storm outlets at existing buildings.
2.8.13 Elevation of existing ground at the lowest point on the proposed lot.
2.8.14 Routing of all major storm flows including the 100 year storm with minimum
basement floor elevations provided for properties with the potential to be affected
by the major storm flows.
2.8.15 Additional design details as required.
2.9
The following shall be shown in addition to the information in section 2.6:
WATERWORKS
2.9.1 All proposed waterworks including size, type and class of pipe, hydrants, valves,
fittings and all related appurtenances with offsets related to road centerline.
2.9.2 Locations of proposed service connections including an offset distance from an
iron pin or lot corner.
2.9.3 Existing ground profile and finished ground or pavement profile, and invert profile
along the centerline of the proposed watermain.
2.9.4 All service crossings to be shown in profile (e.g., sewer mains, water mains,
storm mains, etc.)
2.9.5 Extent of work required in making the connection to existing watermains.
2.9.6 If the proposed watermain alignment or profile varies from the road centerline,
the following shall be provided:
(a)
Stations of the BC and EC of horizontal curves together with curve
information including delta angle, radius, tangent length and arc length.
(b)
Stations and elevations of the BVC, EVC and VPI of vertical curves
together with curve information including curve length and maximum pipe
deflection required.
(c)
Elevations along vertical curves at ten (10) metre intervals.
(d)
Proposed grades.
2.9.7 Additional design details as required.
2.10
The following information shall be shown in addition to the information required for the
plan view in Section 2.6:
STREET LIGHTING, B.C. HYDRO, TELUS
2.10.1 Pole, conduit and appurtenances locations with offsets related to road centerline.
2.10.2 Size, type, class of conduits.
2.10.3 Schematics of wiring details for street lights and traffic signals.
2.10.4 The plan shall be to a scale of 1:500 or 1:250.
2.11
2.11.1 Where there is not sufficient room on the plan and profile drawings, design
details for the particular drawing may be provided on a separate sheet.
DETAIL SHEET AND CROSS-SECTIONS
2.11.2 Scale shall be determined by the designer to suit the design details, and shall be
included with the detail drawing. Scale of the detail shall allow for legibility when
reduced to one-half size.
2.11.3 Where road cross-sections are required, they may be provided on a separate
sheet.
2.11.4 Cross-sections shall be to a scale of 1:250 (H) to 1:50 (V) unless otherwise
approved.
2.11.5 Starting at the lower left hand corner of the drawing sheet, cross-sections shall
be placed up the sheet order of increasing stationing. Grid elevations shall be
shown at the left-hand side of each cross section and stationing shall be shown
below each cross-section. Adequate space shall be left between cross-sections
so as to ensure clarity.
2.11.6 Cross-sections shall include:
(a) Design and road cross-section within the right-of-way.
(b) Existing ground cross-section extending into the adjacent properties as
required.
2.12 AS-BUILT DRAWINGS
2.12.1 Drawings shall include all information as specified elsewhere for the construction
drawings, but shall be corrected upon completion of construction to eliminate all
works removed during construction and reflect "As-Built" conditions for
permanent records.
2.12.2 All dimensions shall reflect the "As-Built" conditions of the construction and all
references to "Proposed" shall be removed. "As-Built" drawings shall be to scale
in accordance with the "As-Built" dimensions shown. The Revision Table shall
be completed indicating the drawings as "As-Built".
2.12.3 The "As-Built" drawings shall be submitted in digital format, dwg and PDF and on
3 mil Mylar so they can be reproduced by standard photocopying to provide clear
and legible prints.
2.12.4 Line work for all constructed works shown on the drawings shall be drawn with
the thicker line density (as for proposed works) for ease of determining the extent
of works covered by the drawings. Proposed construction for future phases of
the project shall not be shown on the "As-Built" drawings.
2.12.5 All drawings shall also include the following information:
(a) The location and elevation of all existing utilities and services encountered in
the construction operation.
(b) The location and invert elevation at property line of all individual service
connections, and the wye chainage, at the main for all constructed and
existing works.
(c) A note on each drawing describing the type of trench material (sand, gravel,
clay, hard pan, etc.) encountered during construction and the location and
profile of all rock.
The following information shall be submitted with the "As-Built" drawings:
2.12.6 Service cards for each lot showing the "As-Built" location of all service
connections.
2.12.7 Street names approved by the District.
2.12.8 Statutory right-of-way and easement drawings.
2.12.9 Revised storm drainage calculations, if required, to reflect changes during the
storm sewer construction.
2.12.10 Revised sanitary sewer calculations, if required, to reflect changes during the
sanitary sewer construction.
2.12.11 Revised street light calculations, if required, to reflect changes during the street
light installations.
2.12.12 All documents listed in District of Tofino - Subdivision Process Description and
Flow chart - Step 7.
2.13
The Site Plan shall be revised to conform to the "As-Built" drawings and submitted on
paper prints (3) and in CAD format as noted below. These drawings will be used as
the basis for Municipal servicing overlays, and must clearly show the following
information:
SITE PLAN
(a)
Standard information as noted in Section 2.3
(b)
Road alignment and lot layout
(c)
Schematic layout of water, sewer and storm drain systems, including the
location of all valves, hydrants, manholes, catch basins and other
appurtenances
(d)
Size and material type of all watermains, sewers and storm drains
(e)
Sidewalk location where required
(f)
Location of street lighting
(g)
Index of plan/profile design drawings
2.14
The following are guidelines to assist in the standardization of computer-generated
drawings submitted to the District of Tofino:
COMPUTER DRAFTING STANDARDS
2.14.1 Drawings shall be 100% compatible with Auto CAD.
2.14.2 Drawing layers, pen colour and line types shall conform to MMCD standards.
2.14.3 Drawings shall be submitted in DWG and PDF format.
2.14.4 The MMCD drawing template shall be utilized.
Subdivision and Development Control Bylaw No. 1201, 2014
20
Schedule 'F' - District of Tofino - Supplementary Specifications
Subdivision and Development Control Bylaw No. 1201, 2014
THIS PAGE IS INTENTIONALLY LEFT BLANK
"Schedule F" District of Tofino
Table of Contents and Explanation of Supplementary Standard Details
Supplementary Specifications - Amendment Register
Supplementary Detail Drawings
Standard Detail Drawings in the Master Municipal Construction Documents are
deleted and replaced by the listed Supplementary Detail Drawings.
Minor changes to the MMCD Standard Detail Drawings are identified by
highlighting the changes on the drawing list.
More significant changes or additional details are presented as additional
Supplementary Detail Drawings.
Concrete and Miscellaneous Details - Supplementary Details
General - Supplementary Details
Roadworks - Supplementary Details
Sanitary Sewer and Storm Drain - Supplementary Details
Watermain - Supplementary Details
Supplementary Specifications
MMCD 31 23 17 (Contractor Responsible for Survey, Monitoring, Control)
"Schedule F" District of Tofino - Supplemental Specifications
AMENDMENT REGISTER
Amendment
No.
Date
Amended
Section
Amended
Page
Description of Amendment
Schedule 'F' - District of Tofino - Supplemental Specifications
Concrete and Miscellaneous - Drawing Index(COLLECTOR ON
1
Concrete and Miscellaneous Details
MMCD Standard Detail Drawing
Tofino Supplemental Detail Drawing
C1
Concrete Sidewalk, Infill and Barrier
Curb
Use MMCD Drawing
No expansion joint material between sidewalk
and curb - use bond break
C2
Concrete Sidewalk and Barrier Curb
Use MMCD Drawing
No expansion joint material between sidewalk
and curb - use bond break
C3
Concrete Sidewalk and Rollover
Curb
Use MMCD Drawing
Sidewalk thickness minimum 150mm
No expansion joint material between sidewalk
and curb - use bond break
C4
Concrete Curbs - Narrow Base
Use MMCD Drawing
Thicken concrete curb by 150mm, or reinforce
with 2 - 15M bars at industrial, commercial,
and multi family (over 2 residences) crossings.
C5
Concrete Barrier Curb - Wide Base
Use MMCD Drawing
Thicken concrete curb by 300mm, or reinforce
with 2 - 15M bars at industrial, commercial,
and multi family (over 2 residences) crossings.
C6
Concrete Median Curb and Interim
Curbs
Use MMCD Drawing
C6A-SD
Valley Curb and Flat Curb
C7
Driveway Crossing and Barrier Curbs
Do Not Use
C7A-SD
Typical Sidewalk and Driveway Crossing -
Type 1
C7B-SD
Typical Sidewalk and Driveway Crossing -
Type 2
C7C-SD
Typical Sidewalk and Driveway Crossing -
Type 3
C7D-SD
Typical Sidewalk Construction and Finishing
Details
C8
Wheelchair Ramp for Sidewalk, Infill,
and Barrier Curb
Do Not Use
C8A-SD
Pedestrian Sidewalk Ramp for Non Mountable
Curb - Single
C8B-SD
Pedestrian Sidewalk Ramp for Non-Mountable
Curb - Double
C10
Concrete Walkway
Do Not Use
C11
Bicycle Baffle
Use MMCD Drawing
Schedule 'F' - District of Tofino - Supplemental Specifications
Concrete and Miscellaneous - Drawing Index(COLLECTOR ON
2
C12
Removable Restriction Post
Use MMCD Drawing
Provide restrictions at 1.5m each side of posts
to ensure that vehicle traffic is restricted.
C13
Chain Link Fence for Walkway
Use MMCD Drawing
C14
Handrail on Concrete Retaining Wall
Use MMCD Drawing
C15-SD
Curb Extension Detail
C16-SD
Temporary Asphalt Curb
Schedule 'F' - District of Tofino - Supplemental Specifications
General Details - Drawing Index
General
MMCD Standard Detail Drawing
Tofino Supplemental Detail Drawing
G1
General Legend for Contract
Drawings
Use MMCD Drawing
G2
Legend for Materials
Use MMCD Drawing
G3
Legend for Street Lights and Traffic
Signal Drawings
Use MMCD Drawing
G4
Utility Trench
Use MMCD Drawing
Minimum 150mm of bedding below pipe in
rock.
G4A-SD
Sanitary and Storm Sewer in Common Trench
G5
Use MMCD Drawing
Pavement Restoration asphalt thickness can
be minimum 50mm asphalt thickness on local
roads, but match existing asphalt thickness to
maximum 80mm.
G6
Concrete Encasement for Watermain
/ Sewer Separation
Use MMCD Drawing
G7
Concrete Protection for Underground
Utilities
Use MMCD Drawing
G8
Pipe Anchor Blocks
Do Not Use
G8A-SD
Trench Dams for Utility Mains
G9-SD
Typical Location of Service Connections to
Residential Vacant Lots
G10-SD
Private Utilities - Underground Electrical
Common Trench Details
G11-SD
Private Utilities - Underground Electrical
Typical Service Box Locations
G12-SD
Bollard Light
Schedule 'F' - District of Tofino - Supplemental Specifications
Roadworks Details - Drawing Index
Roadworks
MMCD Standard Detail Drawing
Tofino Supplemental Detail Drawing
R1
Paved Shoulders
Use MMCD Drawing
R2-SD
Typical Driveway Grades at Curbs
R3-SD
Typical Driveway Grades at Gravel Shoulders
R4-SD
Perforated Steel Base for Signs
R5-SD
Standard Traffic Sign Installation Details
R6-SD
Commercial and Industrial Standard Cul-de-
Sacs
R7-SD
Local Standard Cul-de-Sac
Schedule 'F' - District of Tofino - Supplemental Specifications
Sanitary Sewer and Storm Drain - Drawing Index
1
Sanitary Sewer and Storm Drains
MMCD Standard Detail Drawing
Tofino Supplemental Detail Drawing
S1
Standard and Sump Manholes
Do Not Use
S1A-SD
Typical Manhole Details for Mains to 375mm
diameter - Standard pre-cast type.
S1B-SD
Typical Manhole Benching Details
S2
Standard Manhole Connection
Details
Use MMCD Drawing
Manhole adaptor rings required for plastic
pipes.
S3
Manhole Connection Details - Drop
and Ramp Type
Use MMCD Drawing
Maximum inside ramp to be reduced from
250mm to 150mm.
S4
Inside Drop Manhole
Use MMCD Drawing.
Maximum 200mm drop for 1200mm manhole.
S5
Precast Riser Manhole
Use MMCD Drawing.
Top manhole riser to be 300mm.
S6
Sewer Cleanout
Do Not Use
S6-SD
Temporary Cleanout Structure
S7
Sanitary Sewer Connection
Use MMCD Drawing
Services minimum 0.75 cover.
IC riser green for storm drain, white for
sanitary sewer.
All IC's to be set in in a box per S9, Installation
in a driveway and road.
S8
Storm Sewer Service Connection
Do Not Use
Use MMCD S7 and S9 except paint post
green, IC riser to be green, lid to be green.
S9
Inspection Chamber for 100mm to
200mm Sanitary Sewer Connections
Use MMCD Drawing for Sewer and Drain.
Concrete box and steel checkerplate lid
marked Sanitary or Storm required for all
installations per installation in driveway and
road.
S10
Inspection Chamber for 250 to 375
Storm Sewer Connection
Do Not Use
Use MMCD S8 and S9 for up to 250mm
services. Manholes for over 250mm except
where service ties into a close manhole.
S11
Top Inlet Catch Basin
Do Not Use
S11A-SD
Curb Type Catch Basin for Formed Curbs
Type 1 and Type 2
Schedule 'F' - District of Tofino - Supplemental Specifications
Sanitary Sewer and Storm Drain - Drawing Index
2
S12
Lawn Drains
Use MMCD Drawing
S13
Storm Sewer Inlet With Safety
Grillage
Use MMCD Drawing where appropriate.
Install grates at all storm drain inlets and on
outlets over 375mm.
S14
Concrete Block Headwall
Do Not Use
S14A-SD
Precast Concrete Headwalls for Pipe Inlet and
Outlets (300 to 1200).
Install grates at all storm drain inlets and on
outlets over 375mm.
S14B-SD
Precast Concrete Headwalls for Pipe Inlets
(300 to 450).
Install grates at all storm drain inlets and on
outlets over 375mm.
S15
Driveway Culverts with Concrete
Block Headwalls
Do Not Use
S15-SD
Concrete Filled Sandbag Headwall for Culvert
Inlets and Outlets.
S16-SD
Catch Basin Frame and Grate for Type 1
Catch Basins
S17-SD
Catch Basin Frame and Grate for Type 2
Catch Basins
S18-SD
Adjustable Catch Basin Frame and Hood for
Non Mountable Curbs - Type 3
S19-SD
Detail of Storm Service Box and Inspection
Assembly Installation in Paved Lanes and
High Traffic Areas
S20-SD
Heavy Duty Manhole Cover and Frame
S21-SD
Utility Chamber Manhole Frame, Ring and
Cover
S22-SD
Watertight Manhole Frame and Cover
S23-SD
Standard Plastic Storm Service Box (Special
Applications Only)
S24-SD
Standard Concrete Service Box
S25-SD
Large Service Box
S26-SD
MR Type Steel Service Box
S27-SD
50mm Pressure Sewer Service
S28-SD
Sewage Pump Station "Pig Loader" Detail
Schedule 'F' - District of Tofino - Supplemental Specifications
Sanitary Sewer and Storm Drain - Drawing Index
3
S29-SD
Sewage Pump Station "Pig Loader" Schematic
S30-SD
Tofino Short Duration Rainfall Intensity -
Duration - Frequency Data
S31-SD
Time of Concentration Table
IMPORTANT: CARRIAGE BOLT
TO EXTEND EXACTLY 18mm
ABOVE CASTING.
Schedule 'F' - District of Tofino - Supplemental Specifications
Watermain - Drawing Index
1
Watermains
MMCD Standard Detail Drawing
Tofino Supplemental Detail Drawing
W1
Use as required
W1-SD
Thrust Block Details with Sizing
W2A
Water Service Connection - Service
Box
Do Not Use
W2B
Water Service Connection - Valve
Box
Do Not Use
W2C
Meter Installation for 19mm and
25mm Service Connections
Do Not Use
W2D
Meter Installation for 38mm and
50mm Service Connections
Use MMCD Drawing.
W2-SD
Water Service Connection - 25mm to 50mm
W3
Gate Valve Installation
Use MMCD Drawing.
100mm clear between PVC Riser and Nelson
Box Lid.
PVC Riser to be PVC C900 DR18
Tracer Wire up the outside of the PVC Riser
and between the riser and the Nelson Box
W4
Fire Hydrant Installation
Use MMCD Drawing
Hydrant minimum 900mm cover, maximum
1500mm.
Hydrant flange 100mm above ground level.
Do not apply note 3 (plug in drain hole)
W4A-SD
Hydrant Access - Ditch Crossing Detail
W5
Test Point Installation
Use MMCD Drawing
W6
Air Valve Assembly - 25 and 50mm
Valves
Do Not Use
W6A-SD
Air Release Valve Assembly and Chamber for
150mm to 300mm Mains
W7
Air Valve Assembly- 100mm valve
Do Not Use
W8
Blow Off for Watermain
Do Not Use
W8A-SD
Above Ground Flushout Detail
Schedule 'F' - District of Tofino - Supplemental Specifications
Watermain - Drawing Index
2
W8B-SD
Below Grade Flushout Detail
W9
Blow-Down Chamber
Use as required
W10
Waterworks Chamber Drain
Use as required
W11-SD
Precast Vault Meter Chamber
W12-SD
Fire / Domestic Water Meter Piping Layout
(100 to 150)
W13-SD
Domestic Water Meters Piping Layout (75 to
150)
W14-SD
Detector Check Fire Line Service Piping
Layout (100 to 150)
W15-SD
Fire / Domestic Water Service Piping Layout
(38 to 100)
Schedule 'F' - District of Tofino - Supplemental Specifications
Supplementary Specifications
The following sections of the MMCD Specifications are to be amended as indicated:
MMCD
Section
Subsection
Title
Supplementary Specifications
31 23 17
1.7
Seismic Survey and
Monitoring
1.7.1 Delete wording "Contract Administrator",
and replace with "Contractor".
1.7.2 Delete wording "Owner"
And replace with "Contractor unless otherwise
indicated"
31 23 17
3.1
Blasting and
Vibration Control
Add 3.1.5 "Contractor will be responsible for
all damage resulting from blasting operations."