Zoning Bylaw No. 2506

White Rock, British Columbia · adopted 2024-06-27

This is the exact embedded text of the captured official document. Snapshot 6f69d2d3d945 · verified 2026-06-08 · original document · archived snapshot · unofficial consolidation, the official version is held by the municipal clerk.

THE CORPORATION OF THE CITY OF WHITE ROCK WHITE ROCK ZONING BYLAW, 2024, No. 2506 A Bylaw to regulate the development and use of land in the City of White Rock. DISCLAIMER: THIS BYLAW IS CONSOLIDATED FOR CONVENIENCE ONLY. THE CITY DOES NOT WARRANT THAT THE INFORMATION CONTAINED IN THIS CONSOLIDATION IS CURRENT. IT IS THE RESPONSIBILITY OF THE PERSON USING THIS CONSOLIDATION TO ENSURE THAT IT ACCURATELY REFLECTS CURRENT BYLAW PROVISIONS. Consolidated as of March 2026. SUMMARY TABLE OF AMENDMENTS TO ZONING BYLAW 2024, No. 2506 File No. Bylaw No. Date Adopted Purpose of Amendment Details n/a 2512 2024-09-23 Text Amendment #2 15053 Marine Drive To remove Section 4.1.3, c) in its entirety - to allow a cannabis store authorized by a Temporary Use Permit subject to general conditions at 15053 Marine Drive 20-022 2535 2025-03-10 Text Amendment #6 Rezone 15733 Thrift Avenue from RS-1 SSMUH to RS-2 SSMUH To allow a two-lot subdivision n/a 2517 2025-04-28 Text Amendment #3 Housekeeping To refine general regulations that apply to zones that contain Small Scale Multi-Unit Housing (SSMUH) and to further clarify provisions for the development of SSMUH n/a 2548 2025-10-06 Text Amendment #10 To refine general regulations that apply to off street parking requirements for SSMUH 24-022 2557 2026-01-26 Text Amendment #11 1478 Johnston Rd To refine general permitted use on a site specific basis for a non-medical Cannabis store 21-009 2568 2026-01-26 Text Amendment #13 Rezone 15916 Russell Avenue from RS-1 SSMUH to RS-2 SSMUH To allow a two-lot subdivision 21-011 2569 2026-03-09 Text Amendment #14 Rezone 877 Kent Street from RS-1 to RS-2 To allow a two-lot subdivision. File No. Bylaw No. Date Adopted Purpose of Amendment Details 23-026 2518 2026-03-09 Text Amendment #4 Revision of permitted uses for CD-4, 15154-58 Roper Avenue To revise the live / work requirement contained in a single strata unit that contains a residential use. Zoning Bylaw No. 2506 Page i City of White Rock Zoning Bylaw No. 2506 SCHEDULE "A" - TEXT TABLE OF CONTENTS: 1.0 Introduction ................................................................................................................................. 1 1.1 Purpose ......................................................................................................................................... 1 2.0 General ......................................................................................................................................... 1 2.1 Basic Provisions ........................................................................................................................... 1 2.2 Administration & Enforcement .................................................................................................... 2 2.3 Severability ................................................................................................................................... 2 3.0 Interpretation & Definitions ...................................................................................................... 3 3.1 Zone Boundaries ........................................................................................................................... 3 3.2 Rules of Interpretation .................................................................................................................. 3 3.3 Definitions .................................................................................................................................... 3 4.0 General Provisions & Regulations ........................................................................................... 16 4.1 Uses Permitted/Not Permitted - General .................................................................................... 16 4.2 Comprehensive Zone Coverage .................................................................................................. 18 4.3 Existing Lots of Record .............................................................................................................. 18 4.4 Construction within an Identified Floodplain ............................................................................. 18 4.5 Established Building Line........................................................................................................... 18 4.6 Lot Line Setbacks on Strata Lots ................................................................................................ 18 4.7 Lot Line Setbacks on Pan-Handle (Fee Simple) Lots................................................................. 19 4.8 Building Heights ......................................................................................................................... 20 4.9 Angle of Containment ................................................................................................................ 21 4.10 Floor Area in CD Zones for One-, Two-, and Three-Unit Residential Uses, and in SSMUH Residential Zones ....................................................................................................................... 21 Zoning Bylaw No. 2506 Page ii 4.11 Floor Area in Multi-Unit Residential, Commercial, Public and Mixed Use Zones.................... 22 4.12 Screening & Fencing .................................................................................................................. 22 4.13 Siting Exceptions and Permitted Projections .............................................................................. 23 4.14 Off-Street Parking Requirements ............................................................................................... 24 4.15 Off-Street Loading Requirements ............................................................................................... 28 4.16 Bicycle Parking ........................................................................................................................... 29 4.17 Provision of Electric Vehicle Charging Infrastructure ............................................................... 29 5.0 Specific Use Provisions & Regulations .................................................................................... 31 5.1 Community Care Facilities ......................................................................................................... 31 5.2 Community Services ................................................................................................................... 32 5.3 Accessory Home Occupation Use .............................................................................................. 32 5.4 Accessory Boarding Use............................................................................................................. 33 5.5 Accessory Registered Secondary Suite ...................................................................................... 33 5.6 Accessory Dwelling Unit ............................................................................................................ 33 5.7 Accessory Bed & Breakfast Use ................................................................................................. 34 5.8 Short Term Rental ...................................................................................................................... 34 5.9 Community Gardens ................................................................................................................... 35 6.0 General Zones - Uses Permitted & Zone Provisions ............................................................. 36 6.1 RS-1 SSMUH Residential Zone ................................................................................................. 36 6.2 RS-2 SSMUH Residential Zone ................................................................................................. 41 6.3 RS-3 (Small lot, Hillside) SSMUH Residential Zone ................................................................ 46 6.4 RI-1 (Infill 1) SSMUH Residential Zone - South of Hospital Lands ......................................... 49 6.5 RI-2 (Infill 2) SSMUH Residential Zone ................................................................................... 52 6.6 RE-1 SSMUH Estate Residential 1 Zone ................................................................................... 55 6.7 RE-2 SSMUH Estate Residential 2 Zone ................................................................................... 57 6.8 RM-1 Low Density Multi-Unit Residential Zone....................................................................... 60 6.9 RM-2 Medium Density Multi-Unit Residential Zone ................................................................ 62 Zoning Bylaw No. 2506 Page iii 6.10 RM-3 High Density Multi-Unit Residential Zone ...................................................................... 64 6.11 RM-4 Marine Drive Medium Density Multi-Unit Residential Zone .......................................... 66 6.12 CR-1 Town Centre Area Commercial / Residential Zone .......................................................... 68 6.13 CR-2 Lower Town Centre Area Commercial / Residential Zone............................................... 74 6.14 CR-3 West Beach Business Area Commercial / Residential Zone............................................. 76 6.15 CR-4 East Beach Business Area Commercial / Residential Zone .............................................. 78 6.16 CR-5 Neighborhood Commercial Zone ...................................................................................... 80 6.17 CR-6 Gas Bar/Convenience Commercial 1 Zone ....................................................................... 82 6.18 P-1 Civic / Institutional Use Zone .............................................................................................. 84 6.19 P-2 Church / Assembly Use Zone .............................................................................................. 86 6.20 P-3 Community Care Facility (Low Density) Zone ................................................................... 87 6.21 P-4 Community Care Facility (Medium Density) Zone ............................................................. 89 7.0 Comprehensive Development ("CD") Zones .......................................................................... 91 7.1 CD-1 COMPREHENSIVE DEVELOPMENT ZONE (Peace Arch Hospital) .......................... 91 7.2 CD-2 COMPREHENSIVE DEVELOPMENT ZONE (Vidal & Beachview) ........................ 101 7.3 CD-3 COMPREHENSIVE DEVELOPMENT ZONE (EPCOR - Oxford & Buena Vista) .... 102 7.4 CD-4 COMPREHENSIVE DEVELOPMENT ZONE (15154 - 58 Roper Avenue) ............... 103 7.5 CD-5 COMPREHENSIVE DEVELOPMENT ZONE (15161 Prospect Avenue) ................... 104 7.6 CD-6 COMPREHENSIVE DEVELOPMENT ZONE (15111 - 25 Russell Avenue) ............. 105 7.7 CD-7 COMPREHENSIVE DEVELOPMENT ZONE (14971 Prospect Avenue) ................... 107 7.8 CD-8 COMPREHENSIVE DEVELOPMENT ZONE (15451 Russell Avenue) ..................... 108 7.9 CD-9 COMPREHENSIVE DEVELOPMENT ZONE (15383 - 99 Russell Avenue) ............. 109 7.11 CD-11 COMPREHENSIVE DEVELOPMENT ZONE (15441 - 57 Buena Vista Ave) ......... 111 7.12 CD-12 COMPREHENSIVE DEVELOPMENT ZONE (open for use) ................................... 113 7.13 CD-13 COMPREHENSIVE DEVELOPMENT ZONE (15164 Prospect Avenue) ................. 114 7.14 CD-14 COMPREHENSIVE DEVELOPMENT ZONE (Martin, Foster, & North Bluff) ....... 115 7.15 CD-15 COMPREHENSIVE DEVELOPMENT ZONE (1347 Best Street) ............................. 118 Zoning Bylaw No. 2506 Page iv 7.16 CD-16 COMPREHENSIVE DEVELOPMENT ZONE (Johnston, Thrift & Russell) ............. 119 7.17 CD-17 COMPREHENSIVE DEVELOPMENT ZONE (1400/20 Johnston Rd) ..................... 125 7.18 CD-18 COMPREHENSIVE DEVELOPMENT ZONE (1115 Stayte Road) ........................... 131 7.19 CD-19 COMPREHENSIVE DEVELOPMENT ZONE (1550 Oxford) ................................... 133 7.20 CD-20 COMPREHENSIVE DEVELOPMENT ZONE (991 Stayte Road) ............................. 136 7.21 CD-21 COMPREHENSIVE DEVELOPMENT ZONE (Thrift, Everall, Goggs) .................... 138 7.22 CD-22 COMPREHENSIVE DEVELOPMENT ZONE (open for use) ................................... 144 7.23 CD-23 COMPREHENSIVE DEVELOPMENT ZONE (Johnston - George) ......................... 145 7.24 CD-24 COMPREHENSIVE DEVELOPMENT ZONE (15109 Buena Vista Ave) ................. 154 7.25 CD-25 COMPREHENSIVE DEVELOPMENT ZONE (1456 Everall Street) ........................ 155 7.28 CD-28 COMPREHENSIVE DEVELOPMENT ZONE (1434 Everall Street) ........................ 164 7.29 CD-29 COMPREHENSIVE DEVELOPMENT ZONE (Marine & Oxford) ........................... 172 7.30 CD-30 COMPREHENSIVE DEVELOPMENT ZONE (1424 Everall Street) ........................ 179 7.31 CD-31 COMPREHENSIVE DEVELOPMENT ZONE (1450 Vidal Street) ........................... 188 7.32 CD-32 COMPREHENSIVE DEVELOPMENT ZONE (1455 - 65 Vidal Street) ................... 194 7.33 CD-33 COMPREHENSIVE DEVELOPMENT ZONE (application deferred) ....................... 203 7.34 CD-34 COMPREHENSIVE DEVELOPMENT ZONE (1321 Fir Street) ............................... 204 7.35 CD-35 COMPREHENSIVE DEVELOPMENT ZONE (15118 Thrift Avenue) ..................... 210 7.36 CD-36 COMPREHENSIVE DEVELOPMENT ZONE (15577 - 85 Marine Drive) ............... 216 7.37 CD-37 COMPREHENSIVE DEVELOPMENT ZONE (application deferred) ....................... 224 7.38 CD-38 COMPREHENSIVE DEVELOPMENT ZONE (open for use) ................................... 225 7.40 CD-40 COMPREHENSIVE DEVELOPMENT ZONE (1330 - 46 Foster Street) .................. 226 7.41 CD-41 COMPREHENSIVE DEVELOPMENT ZONE (1467 - 1519 Vidal Street) ............... 230 7.46 CD-46 COMPREHENSIVE DEVELOPMENT ZONE (1500 Oxford Street) ........................ 241 7.48 CD-48 COMPREHENSIVE DEVELOPMENT ZONE (15611 Marine Drive) ....................... 249 7.51 CD-51 COMPREHENSIVE DEVELOPMENT ZONE (14825 & 14835 Thrift Avenue) ...... 253 7.54 CD-54 COMPREHENSIVE DEVELOPMENT ZONE (Best & Roper) ................................. 258 Zoning Bylaw No. 2506 Page v 7.56 CD-56 COMPREHENSIVE DEVELOPMENT ZONE (Nichol & North Bluff) .................... 263 7.57 CD-57 COMPREHENSIVE DEVELOPMENT ZONE (Finlay/Russell) ................................ 269 7.58 CD-58 COMPREHENSIVE DEVELOPMENT ZONE (1350 Johnston Road)....................... 277 7.59 CD-59 COMPREHENSIVE DEVELOPMENT ZONE (15241 Thrift Avenue) ..................... 285 7.61 CD-61 COMPREHENSIVE DEVELOPMENT ZONE (1310 Johnston Road)....................... 292 7.62 CD-62 COMPREHENSIVE DEVELOPMENT ZONE (1453 Stayte Road) ........................... 294 7.64 CD-64 COMPREHENSIVE DEVELOPMENT ZONE (1485 Fir Street) ............................... 301 7.66 CD-66 COMPREHENSIVE DEVELOPMENT ZONE (1539 Maple Street) ........................... 308 SCHEDULE "B" - Zone Maps Zoning Bylaw No. 2506 Page 1 1.0 Introduction 1.1 Purpose The purpose of this zoning bylaw, in accordance with Part 14 of the Local Government Act, is to establish land use regulations for the City of White Rock consistent with the White Rock Official Community Plan respecting: a) the use of land, including the surface of water; b) the density of the use of land, buildings, and structures c) the siting, size, and physical dimensions of buildings and structures; d) the provision of off-street parking and loading spaces; e) landscaping and screening; and f) runoff control 2.0 General 2.1 Basic Provisions 2.1.1 Within the City of White Rock, no person shall: a) use any land, buildings or structures; b) commence any construction to erect, move, enlarge or structurally alter any building or structure; or c) create a lot by subdivision under the Land Title Act or Strata Property Act; except as permitted by: i) the provisions and regulations of this Bylaw ii) the provisions and regulations of this Bylaw as varied by order of the Board of Variance in accordance with the Local Government Act iii) the provisions and regulations of this Bylaw as varied by a Development Permit approved by Council in accordance with the Local Government Act iv) the provisions and regulations of this Bylaw as varied by a Development Variance Permit approved by Council in accordance with the Local Government Act v) a Temporary Use Permit approved by Council in accordance with the Local Government Act vi) the non-conforming uses and other continuations provisions of the Local Government Act vii) Respecting subdivision, Section 511 [Bylaws adopted after application for subdivision submitted] and Section 514 [Subdivision to provide residence for a relative] of the Local Government Act 2.1.2 No provision or regulation of this Bylaw shall be construed to replace or remove the requirement for approvals under any other act or regulation. Zoning Bylaw No. 2506 Page 2 2.1.3 Properties with uses existing at the date of adoption of this bylaw have, in some instances, been zoned to recognize existing long-standing uses in transitional areas, or otherwise to recognize existing lot areas for older historical properties. 2.1.4 This bylaw uses comprehensive development zones (CD zones) as a means to accommodate site specific proposals, minimize the use of restrictive covenants, and to incorporate "form-based" zoning which has broad implications for community livability, and is intended to accommodate community input on the form, character and density for these projects. 2.1.5 Residential buildings in the RE, RI, and RS zones that were lawfully constructed but rendered non-conforming for residential gross floor area with the approval of this bylaw, may be reconstructed to their original size if damaged or destroyed to the extent of 75% or more of their assessed value above the foundation by fire or other natural causes. 2.1.6 Metric units are used for all measurements in this Bylaw. The approximate equivalent in imperial units are included for convenience only and do not form part of this Bylaw. 2.2 Administration & Enforcement 2.2.1 A Building Official, Bylaw Enforcement Officer, Business License Inspector or other employee appointed by the City of White Rock to administer and enforce this Bylaw is hereby authorized pursuant to Section 16(6) of the Community Charter to enter, at all reasonable times, on any property including land and improvements, that is subject to this Bylaw, to inspect and determine whether the regulations and provisions of this Bylaw are being or have been complied with. The Building Official, Bylaw Enforcement Officer, Business License Inspector or other appointed employee shall undertake such entry and inspection in accordance with the procedures outlined in the relevant City Bylaws and in accordance with Section 16(6) of the Community Charter. 2.2.2 A Building Official for or on behalf of the City of White Rock, where applicable, shall not issue any permit except in accordance with the provisions and regulations of this Bylaw. 2.2.3 No person shall prevent or obstruct the entry of a Building Official, Bylaw Enforcement Officer, Business License Inspector or other appointed employee of the City of White Rock on property in the administration of this Bylaw. 2.2.4 Any owner or occupier of land, who causes, suffers, or permits any contravention of any provision of these regulations is guilty of an offense and is liable on conviction for the payment of penalties imposed under the Offence Act. Every day that an offence under this Bylaw is caused or allowed to continue, constitutes a separate offence and separate fines, each not exceeding the maximum for that offence, may be imposed for each day during which the offence continues. 2.3 Severability 2.3.1 Every provision of this Bylaw is independent of all other provisions and if any provisions of this Bylaw is declared invalid for any reason by a Court of competent jurisdiction, all other provisions of this Bylaw shall remain valid and enforceable. Zoning Bylaw No. 2506 Page 3 3.0 Interpretation & Definitions 3.1 Zone Boundaries 3.1.1 The precise boundaries of each zone shall be interpreted as following the boundary of a lot, the centre line of a road allowance or stream, or as outlined in Schedule "B" - Zone Maps. 3.2 Rules of Interpretation 3.2.1 Words, phrases and terms used in this Bylaw that are neither defined in this Bylaw nor in the Local Government Act or the Community Charter or the Interpretation Act shall be given their usual and customary meaning. 3.2.2 Where the regulations set forth in this Bylaw conflict with the terms and conditions contained in an existing Land Use Contract, the terms and conditions contained in the Land Use Contract shall prevail. 3.3 Definitions 3.3.1 For the purposes of this Bylaw, the following defined words, phrases and terms shall have the meaning assigned to them below, unless the context otherwise requires: "accessory bed & breakfast use" means a use that is accessory to a one-unit residential use that provides temporary accommodations for the travelling public. "accessory boarding use" means the use of a room or rooms (similar to sleeping units) in a dwelling unit used for the accommodation of roomers and boarders for periods greater than 30 days with either private or shared sanitary facilities and without separate cooking facilities or equipment; this use shall not be permitted in conjunction with a hotel, accessory bed & breakfast use, accessory registered secondary suite, short term rental, care facility, or any other similar commercial or institutional use. "accessory child care centre" means a child care centre within the licensee's personal residence where child care is provide for no more than eight (8) children. "accessory dwelling unit" means a self-contained dwelling that: a) is accessory and detached to the principal building; b) has cooking, food preparation, sleeping and bathing facilities that are separate from those of the principal building located on the lot; c) has an entrance separate from the entrance to the garage; and, d) is a separate and distinct use from an accessory secondary suite, and does not include its own secondary suite. "accessory home occupation" means an occupation or profession carried on as a business by a person residing in the same dwelling unit in a manner ancillary to the residential use of the dwelling unit. Zoning Bylaw No. 2506 Page 4 "accessory registered secondary suite" means a smaller ancillary dwelling unit contained entirely within a principal dwelling unit, where the principal dwelling unit is a single real estate entity located on a free hold titled parcel of land, and that is registered with the City of White Rock as a secondary suite. "accessory use" means a use which is subordinate and customarily incidental to the principal use and located on the same lot as the principle use. "adult entertainment use" means a use of an establishment, or part thereof that provides adult-oriented entertainment, not suitable for viewing by minors, including, but not limited to, exotic dancing whereby entertainers remove clothing during a performance and/or perform in a sexually suggestive manner, or entertainment involving full or partial nudity. "agency store" means a liquor store operated by an agent appointed under section 18 (5) of the Liquor Distribution Act. "air space parcel" means a volumetric parcel shown on an air space plan, whether or not occupied in whole or in part by a building or other structure. "ancillary building" means a building which is detached from, subordinate and customarily incidental to the principal building permitted on the same parcel of land and, without limiting the generality of the foregoing, includes accessory dwelling units, detached garages, detached carports, detached workshops and storage sheds. "ancillary car wash" means a facility for the washing of motor vehicles with a rated gross vehicle weight of 5,000 kg or less on an automated, semi-automated or manual basis, and ancillary to a gas bar/convenience store. "apartment" means a multi-unit residential building where all dwelling units have access only through common corridors, stairways and lobbies. "assembly use" means the use of a building or part thereof, by a gathering of persons for civic, political, travel, religious, social, educational, and recreational or like purposes. "assisted living residence" means a premises or part of a premises, other than a community care facility, in which housing, hospitality services and at least one but not more than two prescribed services are provided by or through the operator to three or more adults who are not related by blood or marriage to the operator of the premises. "average natural grade" see grade, average natural. "balcony" means an unenclosed platform cantilevered off of a building. "bay, bow and box windows" means a window space projecting out from the walls of a building. Zoning Bylaw No. 2506 Page 5 "basement" means the area of a building where the floor area is located no less than 0.6m (2.0ft) below finished grade. "bedroom" means a room located in a dwelling which, due to its design or location in the dwelling, is or may be used primarily for sleeping regardless of its use. "building" means any structure wholly or partly enclosed by a roof or roofs, supported by walls, columns or posts and used or intended for the shelter or accommodation of persons, animals, chattels or things. "Building Official" means a person employed by or contracted to the City to administer the Building Bylaw and the BC Building Code. "Business License Inspector" means a person employed by or contracted to the City to administer the Business License Bylaw, and other bylaws of the City, including, but not limited to, the Zoning Bylaw, the Sign Bylaw and the Sidewalk Café/Business License Bylaw. "Bylaw Enforcement Officer" means a person employed by or contracted to the City to administer all City bylaws. "cannabis store" means a government cannabis store under the Cannabis Distribution Act, as amended, or an establishment licensed under the Cannabis Control and Licencing Act, as amended. "cantilever" means an overhang where all or part of the floor area extends beyond and over a foundation wall. "care facility" means a building which contains sleeping units for persons receiving care or assistance where the building and/or operator are regulated or funded by provincial or federal agencies, including care and assisted living as defined and regulated under the Community Care and Assisted Living Act as amended. "carport" means an open-sided structure used or intended to be used for the storage of vehicles and attached to the principal building on no more than two sides. "child care centre" means a facility that provides child care, including group child care, preschool, family child care, occasional child care, and multi-age child care as defined, licensed and regulated under the Community Care and Assisted Living Act as amended, and is distinct from a care facility. "church" means a building or structure or part thereof used for religious worship or organized religious services and associated accessory uses which may include a church hall or auditorium, nursery school, child care centre, parish hall, and an accessory dwelling unit. Zoning Bylaw No. 2506 Page 6 "civic use" means a use providing for public functions and services including federal, provincial and municipal offices and yards, public schools and colleges, public hospitals, community centres, libraries, museums, parks, playgrounds, cemeteries, tourist information, waterways, and includes private and public utilities. "commercial floor area" means the sum total of floor areas of each storey in a building used for commercial purposes, inclusive of exterior walls, areas occupied by internal walls and partitions, and excluding storage areas open to employees only, common stairwells, elevator shafts, common corridors, heating, maintenance and service areas, and enclosed parking facilities. "community amenity space" means floor area used for community amenities that are provided by the constructor of a building as community amenities under a phased development agreement or amenity rezoning bylaw in accordance with prevailing legal requirements of the City. "community garden" means an area managed by a non-profit society, public entity, or community organization, where members of the community may grow edible and ornamental plants for personal use or community distribution. "community service" means a use by a non-profit society: a) providing information, referral, counseling, advocacy, or physical or mental health services on an out-patient basis; b) dispensing aid in the nature of food or clothing; or c) providing drop-in or activity space; but does not include churches, residential uses or care facilities. "cooking facility" means a space with facilities for the preparation or cooking of food, and includes any room containing counters, cabinets, plumbing or wiring which taken together, may be used for the preparation or cooking of food. "crawlspace" means an interior building space at or below finished grade, between the underside of the floor system next above and the top of the floor slab on the ground surface below, having a vertical clearance less than 1.5 m. "deck/elevated patio" means an uncovered and unenclosed raised platform area constructed out of wood, metal, plastic or concrete greater than 0.6m above finished grade around the raised platform. "density" means a measurement of development intensity on a lot which shall be in either floor area ratio or unit density. "dwelling unit" means one or more rooms used for the residential accommodation of one or more persons as an independent and separate residence containing cooking, living, sleeping and sanitary facilities, but specifically excludes a recreational vehicle and does not include a room in a hotel or motel. Zoning Bylaw No. 2506 Page 7 "electric vehicle" means a vehicle that uses electricity for propulsion, and that can use an external source of electricity to charge the vehicle's batteries. "electric vehicle supply equipment" means a complete assembly consisting of conductors, connectors, devices, apparatus, and fittings installed specifically for the purpose of power transfer and information exchange between a branch electric circuit and an electric vehicle. "electric vehicle energy management system" means a system to control electric vehicle supply equipment electrical loads comprised of monitor(s), communications equipment, controller(s), timer(s) and other applicable devices. "energized outlet" means a connected point in an electrical wiring installation at which current is taken and a source of voltage is connected to supply utilization equipment. "exterior side yard" means a side yard that abuts a road on a corner lot. "farmers' market" means a reoccurring commercial use managed by a non-profit society, a public entity, or community organization, that provides for the sale of local agricultural products, locally produced alcohol (beer, wine, spirits and other similar alcohol), local artisan goods, and prepared foods and beverages, by independent vendors directly to consumers. "fence" means an unenclosed structure used as a barrier to enclose or partially enclose a parcel of land. "first storey" means the story above the basement, but where no basement exists, the lowest storey in the building. "food primary" means a restaurant that includes a dining establishment issued a food primary license pursuant to the Liquor Control and Licensing Act. "front yard" means the area between the side lot lines extending from the front lot line to the nearest wall of the building. "gas bar" or "gas bar/convenience store" means a business establishment for the retail sale of automotive fuels (including gasoline, diesel fuel, gasohol, propane and natural gas) and lubricating oils, including the sale of products ancillary to automotive fuel sales, and the minor servicing and repairing of automobiles excluding auto body repair. It also includes the retail sale of convenience items, including food, tobacco, pharmaceuticals, periodicals, snack foods or other similar household convenience items. "grade, average natural" means the average that is determined by measuring at the midpoints of the walls of the four sides of the building or structure (see sub-section 4.8). Zoning Bylaw No. 2506 Page 8 "grade, finished" means the actual finished grade of the land adjacent to the foundation of a building or structure. "grade, natural" means the grade of the lot, as determined by a B.C. Land Surveyor, prior to any construction or alteration of the site. "gross floor area" means the sum total of floor areas of each storey in a building, inclusive of exterior walls. Gross floor area shall exclude community amenity space. "health service facility" means a facility providing room, board and surgical or other medical treatment for the sick, injured or infirm including outpatient services, including but not limited to private hospitals, nursing homes with health care for dependent residents, mental health facilities, detoxification centres and adult day care. "height" means, with reference to a fence, the vertical distance between the highest point of the fence and the natural grade elevation at that point; and, with reference to a building or structure, the vertical distance between the highest point of the building or structure and the average natural grade except where indicated otherwise. "height, ceiling" means the vertical distance from top of the finished floor of a storey to: a) the underside of the floor joist; b) the underside of the roof joist; c) the underside of the bottom chord of a structural truss; or d) the underside of a structural deck above that storey. Whichever is the greatest distance from the finished floor. "hospitality service" means meal services, housekeeping services, laundry services, social and recreational opportunities and a 24 hour emergency response system. "hotel" means a building or buildings containing sleeping units, where payment for occupancy is usually on a daily or weekly basis to the operator of the premises, and may include ancillary services such as restaurants, meeting or conference rooms, recreational facilities, and entertainment facilities issued a liquor primary license pursuant to the Liquor Control and Licensing Act. "home office" means an accessory use of a dwelling unit, where business or office activities are conducted that does not exceed 10m2. The home office would be an ancillary use for a primary business or office use located elsewhere. "house-plex" means a single building on a fee simple lot designed to accommodate two or more dwelling units, each having a separate exterior entrance directly accessible from a road and which may share common walls with adjacent dwelling units, may be arranged above, below or beside each other. Each dwelling unit must have a minimal residential gross floor area of 96m2, with no dwelling unit having a residential gross floor area Zoning Bylaw No. 2506 Page 9 greater than 20 percent of the dwelling unit with the least residential gross floor area. Does not include a semi-detached residential building, rowhouse residential building, apartment, townhouse, hotel or motel. "impermeable surfaces" means any constructed surface on, above or below ground that does not allow precipitation or surface water to penetrate directly into the underlying soil. Surfacing materials considered impermeable include concrete, asphalt, brick, stone, ground pavers, pools, and other similar materials, and include buildings and structures. "institutional floor area" means the sum total of floor areas of each storey in a building used for institutional purposes, inclusive of exterior walls, areas occupied by internal walls and partitions, and excluding storage areas open to employees only, common stairwells, elevator shafts, common corridors, heating, maintenance and service areas, and enclosed parking facilities. "interior side yard" means a side yard abutting another lot. "lane" means a dedicated road allowance less than 10.0m (32.8ft) in width intended to provide rear or side access to a lot and/or a private or common access to a building complex or bare land strata development. "Level 2 charging" means a Level 2 electric vehicle charging level as defined by SAE International's J1772 standard. "licensed establishment" means a business premise or establishment licensed under the Liquor Control and Licensing Act and the Liquor Control and Licensing Regulation as amended, including liquor primary, food primary, brewery, winery, distillery, u-brew, and u-vin. "liquor primary" means a licensed establishment where the primary purpose is the sale of alcoholic beverages for consumption on-site. "liquor store" means a government liquor store, government beer store or government wine store licensed under the Liquor Distribution Act. "live plant material" means soft landscaping elements planted directly into the ground at natural grade, such as trees, shrubs, plants, or ornamental plantings that are capable of healthy growth. "localized depression" means a depression below the finished grade, created for the purpose of providing a pedestrian entrance to a residential building. "lot" means a parcel of land, air, Crown Land or Lease registered in the Land Title Office but, for the purpose of this Bylaw, an Air Space Parcel, shall be deemed to be part of the same lot as the parcel at ground level. Zoning Bylaw No. 2506 Page 10 "lot area" means the total horizontal area of land within the lot lines of a lot. "lot coverage" means the area of a lot covered by any and all buildings measured to the outside of the outermost walls and expressed as a percentage of the lot, and includes any cantilevered floor area and chimneys as well as covered decks, covered porches, covered entranceways, carports, detached garages and ancillary buildings including detached garages and sheds. "lot depth" means the least horizontal distance between the front and rear lot lines, but where the lot has irregular shape, the minimum lot depth may be the average of the lot line with the least lot depth and the lot line with the most lot depth. "lot frontage" means the horizontal distance between the side lot lines, such distance being measured along a line parallel to the front lot line a distance from that line equal to the minimum required front-yard depth, except for "pan-handle lots" as further defined. "lot line" means the legal boundary of a lot that divides one lot from another, or that divides a lot from a road allowance or park dedication area. "lot line, exterior" means the lot line or lines, not being the front or rear lot lines, common to the lot and a street. "lot line, front" means the lot line common to the lot and an abutting street or where there is more than one lot line common to abutting streets, the shortest of these lines shall be considered as the front lot line. "lot line, rear" means the lot line opposite to and most distant from the front lot line, or, where the rear portion of the lot is bounded by intersecting side lot lines, shall be deemed to be the point of such intersection. "lot line, side" means a lot line other than a front or rear lot line. "lot width" means the horizontal distance of the front lot line between the side lot lines. "medical or dental clinic" means a building or part thereof where members of the medical profession including, but not limited to, dentists, chiropractors, osteopaths, optometrists, physicians or occupational therapists provide diagnosis and treatment to the general public without overnight accommodation, and may include reception areas, offices for consultation, treatment rooms, including x-ray and minor operating rooms, a pharmaceutical dispensary, and a coffee shop. A medical or dental clinic may also include a facility for removal of tattoo's/body art. "mixed-use building" means a building containing a combination of residential uses and non-residential uses, and any accessory uses thereto. Zoning Bylaw No. 2506 Page 11 "multi-unit residential use" means a building or part thereof which contains two (2) or more dwelling units, excluding secondary suites, accessory dwelling units and house-plex, and includes apartment, and townhouse. "neighborhood convenience store" means the retail sale of convenience items, including food, tobacco, pharmaceuticals, periodicals, snack foods or other similar household convenience items. "off-street loading space" means an on-site parking space reserved for temporary parking for the purpose of loading or unloading of goods and materials. "off-street parking space" means a space for the parking of a vehicle either inside or outside of a building or structure, but does not include maneuvering aisles and other areas providing access to the space. "one-unit residential use" means a residential use limited to one dwelling unit on a lot exclusive of an accessory registered secondary suite, and includes SSMUH residential zones. "owner" means the person or persons listed as the titleholder on a property's legal certificate of title registered in the BC Land Title Office. "parking facilities" means an off-street area or structure for the temporary parking of vehicles, and may include at-grade, below-grade or above-grade facilities as a principal use. "parks" and/or "natural areas" means an area of land designated and used by the public for active or passive recreation and/or an area of land in a natural or undeveloped condition where lands are restricted for future development by enactment, statute or covenant. "party wall" means a shared supporting wall that is between two adjoining buildings and is situated on any part of the common boundary shared by adjoining free hold parcels of land. "permeable surfaces" means any surface treatment that allows precipitation or surface water to penetrate directly into the underlying soil and shall include a combination of the following: a) live plant material; b) gravel, river rock less than 5 cm in size, wood chips, bark mulch, with no associated layer of impermeable material, such as plastic sheeting, that would impede the movement of water directly to the soil below. c) wood decking with spaced boards and other materials which, have fully permeable characteristics when placed or installed on grade. Zoning Bylaw No. 2506 Page 12 "preparation cooking facility, residential" means an accessory cooking facility to the principal cooking facility in a dwelling unit that is adjacent to the principal cooking facility and must be connected. The connection can be through a doorway that does not lock and forms part of the same dwelling unit as the principal cooking facility. A residential preparation cooking facility cannot exceed 9.0m2. "prescribed bus stop" means a bus stop served by at least one bus route that is scheduled to stop at least every 15 minutes, on average, between the hours of: (a) 7 a.m. and 7 p.m., Monday to Friday; (b) 10 a.m. and 6 p.m., on Saturdays and Sundays as defined and amended from time to time in the Provincial Government's Policy Manual and Site Standards for Small Scale Multi-Unit Housing. "principal building" means a building of which the floor space is used for a permitted principal use. "principal use" means the primary use of land, buildings or structures. "public utility use" means uses providing for the essential servicing of the City with water, sewer, electrical, telephone and similar services where such use is established by the Corporation, by another governmental body or by a company operating under the Utilities Commission Act, and includes broadcast transmission facilities, sewer, water- main, and power line easements, pump houses, sub-stations, telephone exchanges, traffic controls, and related ancillary buildings and structures. "railway use" means a railway use and operation within the legislative authority of Parliament and includes (a) branches, extensions, sidings, railway bridges, tunnels, stations, depots, wharfs, rolling stock, equipment, stores, or other things connected with the railway, and (b) communications or signaling systems and related facilities and equipment used for railway purposes. "rear yard" means the area between the side lot lines extending from the rear lot line to the nearest wall of a building. "recreation facilities" means a curling rink, skating rink, swimming pool, playing field, public park, public playground. "recycling use" means a use completely contained within a building for collection only for recycling goods which is limited to a material which is gathered for the main purpose of reprocessing a raw material for manufacturing purposes. "residential floor area" means the sum total of floor areas of each storey in a building for multi-unit residential use which contains four (4) or more dwelling units, measured to the mid-point of the exterior walls, including areas occupied by internal walls and partitions, and excluding unenclosed balconies, common stairwells, elevator shafts, common corridors, enclosed parking facilities, and common recreation or amenity areas. Zoning Bylaw No. 2506 Page 13 "residential gross floor area" means the sum total of floor areas of each storey in a building containing a one-, two- or three-unit residential use, excluding a basement, cellar, crawl spaces, carport, garage, bay window, bow window or box window, elevator shafts, and areas occupied by stairs on the second storey of a building. In SSMUH Residential zones, residential gross floor area means the sum total of floor areas of each storey in a building containing a residential use, excluding covered patios and decks up to 37m2; stairwell up to 13m2; crawlspace; carports and garages up to 46.50m2; and elevator shafts. "residential use" means a building consisting of a dwelling unit for residential occupancy as the principal use for long term accommodation for periods in excess of one (1) month. "restaurant" means a business establishment where food and beverages are prepared, served and consumed on the premises, including dining establishments issued a food primary license pursuant to the Liquor Control and Licensing Act, and includes facilities for ordering and pick-up for consumption off-site. "retail service group 1 use" means a use providing for the sale at retail or repair of household or personal goods or things, or for extending services to persons; is limited to: sale of automotive goods, health clubs, veterinary clinics, appliance repairs, appliance stores, art galleries, bakery shops, banks, barbers, billiard halls, book shops, bowling alleys, business offices, business schools, cafes, camera shops, clothing stores, coffee houses, dance studios, delicatessens, department stores, drug stores, dry cleaners, financial services offices excluding "money marts" or "pay-day cash services" (not permitted), fish markets, grocery stores, hairdressers, hardware, home furnishing stores, launderettes, meat markets, medical or dental clinic, music studios, passenger depots, personal furnishing shops, printers, professional and semi-professional offices, restaurants, secondhand stores excluding "pawnshops" (not permitted), shoemakers, social clubs, stationery stores, super markets, tailors, tattoo/body art studio, theatres, toy stores, trade schools and variety stores; excludes a use providing for the sale at retail or servicing of non-household or non-personal goods or things, or for the sale at retail or servicing of any goods or things that necessitate access by motor vehicle or a use located other than in a permanent type building. "retail service group 2 use" means a use providing for the sale at retail or servicing of non-household or non-personal goods or things, or for the sale at retail or servicing of any goods or things that necessitate access by motor vehicle; is limited to: building or home supply retail sales, business schools, car washes, curling rinks, drive-in facilities, drive-in restaurants and cafes, dry cleaners, gas bar, glass sales, health clubs, heating shops, light machinery sales, light marine sales, mortuaries, new automobile sales, nurseries, plumbing shops, recreation clubs, repair of automobiles, servicing of automobiles, sheet metal shops, skating rinks, social clubs, used automobile sales; excludes a use located other than in a permanent type building. Zoning Bylaw No. 2506 Page 14 "retail store" means a building where goods, wares, merchandise, substances, articles, or things are stored, offered or kept for sale at retail and includes storage on or about the store premises of limited quantities of the goods, wares, merchandise, substances, articles, or things sufficient only to service the store. "retaining wall" means a wall or similar works constructed to hold back, stabilize, support or retain soil, rock or a bank of earth. "roughed-in electric vehicle charging infrastructure" means a Level 2 charging service including a 240v or 208v circuit breaker on an energized electrical panel connected by raceway to an outlet. "rowhouse residential building" means a building containing a minimum of three and a maximum of six structurally independent dwelling units, all aligned in a row and divided vertically by party walls. Each dwelling unit is located on a separate freehold lot, and where permitted by this Bylaw, may include an accessory registered secondary suite. "semi-detached residential building" means a building containing two structurally independent dwelling units divided vertically with a party wall, with each dwelling unit located on a separate freehold lot and where permitted by this Bylaw, an accessory secondary suite. "SSMUH" means Small-Scale, Multi-Unit Housing. "setback" means the distance between the lot line and the exterior of a building or structure measured from the lot line to the exterior face of the building or structure and within which no part of any building or structure may be situated, except those matters and items specifically excluded from a setback or yard requirement permitted as exemptions elsewhere in this bylaw. "shipping container" means an enclosed unit used or intended to be used for storing and transporting goods via ship, rail or truck, whether or not it is actually being used for such purpose. "short term rental" means the rental of a residential dwelling unit to short-term paying guests for periods not to exceed ninety (90) days. "side yard" means the area between side lot lines and the nearest wall of a building extending from the front yard to the rear yard. "special event" means any public or private exhibition, farmers' market, parade, procession, carnival, athletic event, public performance or show, held on public property, including any street, road, lane, park, or other public right of way or place. "sleeping unit" means a hotel or tourist accommodation room rented to the general public and used for temporary or overnight sleeping accommodations on a daily or weekly basis, Zoning Bylaw No. 2506 Page 15 and may include in room sanitary facilities, but excludes in-room kitchen or cooking facilities. "storey" means that portion of a building which is situated between the surface of any floor and the surface of the floor next above it and, if there is no floor above it, that portion between the surface of such floor and the ceiling surface above it. A storey shall not include a basement, cellar, or crawl space, except for those portions of a basement which contain a residential floor area, institutional floor area or commercial floor area. "street" means a road allowance or road dedication area 10.0m (32.81ft) or more in width. "structure" means anything constructed, fixed to, placed, sunken or erected on land or water which is greater than 0.6m above or below finished grade excluding landscape trellises or arbors, window wells, hot tubs and in-ground or above ground swimming pools. "three-unit residential use" means a multi-family residential building containing three (3) dwelling units attached as one building entity, and excludes SSMUH Residential Zones. "townhouse" means a multi-unit residential use which is attached horizontally and which usually contains three or more dwelling units, and which has a principal entrance(s) which provides direct outdoor access at or from ground level, but does not include a house-plex, apartment or a hotel. "two-unit residential use" means a residential use where the building contains two dwelling units per fee-simple lot, either one above the other and separated by a ceiling and floor extending from exterior wall to exterior wall, or side by side and separated by a common wall extending from ground to roof, including detached dwelling units which are linked by a carport or garage that share a continuous permanent foundation and common roof area, but does not include a one unit residential use plus accessory registered secondary suite and excludes SSMUH Residential Zones. "u-brew" or "u-vin" means an establishment licensed under Section 12.1 of the Liquor Control and Licensing Act to operate a u-brew or u-vin. "underground" means a portion of a building or structure located either entirely beneath a building or below the level of the ground, where the building or the structure is below the finished grade of the immediately adjacent land. "window well" means a recess in the ground around a building to allow for the installation of a window in a basement, either below ground or partially below ground. "yard" means an area created by setback. ‘‹‰›Žƒ™‘ǤʹͷͲ͸ ƒ‰‡ͳ͸ 4.0 General Provisions & Regulations 4.1 Uses Permitted/Not Permitted - General 4.1.1 No person shall use or occupy any building, structure or land, including land covered by water, except as expressly permitted by and in compliance with all provisions of this bylaw. Any use not expressly permitted is prohibited. 4.1.2 The following uses are permitted in all zones: a) uses, buildings, and structures in accordance with the regulations of this bylaw; b) public parks and playgrounds, including the following uses only where authorized by permit issued pursuant to the White Rock Parks Regulation By-law, 1977, No. 675 as amended, or another applicable license or agreement with the City of White Rock: i) community gardens; ii) special events; iii) mobile food vendors; iv) outdoor recreation equipment rental and classes; and v) display and retail sale of artwork by the licensed artist; and c) public parking facilities, a public utility, public utility buildings and structures (excluding a garage or storage yard under jurisdiction of the City of White Rock, the Province of British Columbia, or Crown Corporation) including utilities maintained and operated by the City of White Rock as well as those defined in the Utilities Commission Act. 4.1.3 a) A use authorized by a Temporary Use Permit issued under the provisions of the Local Government Act, with the exception of a cannabis store, is permitted in any zone. b) A cannabis store authorized by a Temporary Use Permit issued under the provisions of the Local Government Act is permitted in the Town Centre area, bounded by North Bluff Road, George Street, Thrift Avenue, and Martin Street, in accordance with the following general conditions: i) the premises containing the cannabis store use shall be located a minimum of 100 metres from an entrance to an existing child care centre (notwithstanding, a new child care centre shall not be limited by the distance to a cannabis store); ii) there shall be no more than two lots containing a cannabis store use in the area bounded by North Bluff Road, George Street, Thrift Avenue and Martin Street; iii) the premises containing the cannabis store use shall be located a minimum of 30 metres from Byrant Park, Hodgson Park, and the Town Square located at 1510 Johnston Road; iv) unless a government cannabis store, the cannabis store has a valid license issued in accordance with the Cannabis Control and Licensing Act, as amended; v) the cannabis store shall not sell any goods or things until the Cannabis Act has come into force, and it has obtained a valid business licence (no business licence will be issued to any applicant for cannabis store use unless the City has been provided with written consent by the Owner or the Owner's Agent as authorized in writing by the Owner). ‘‹‰›Žƒ™‘ǤʹͷͲ͸ ƒ‰‡ͳ͹ c) A Cannabis store is permitted use on a site-specific basis at 1478 Johnston Road (West Half Lot 2 Except: The West 7 Feet; Section 11 Township 1 New Westminster District Plan 8096) subject to section 4.1.3 b) through (i-v), except the distance under 4.1.3 b) i, will be decreased from 100m to 80m from an entrance to an existing childcare centre. 4.1.4 Decks/elevated patios must be attached to a principal building and are only permitted behind the front face of the building. 4.1.5 The commercial cultivation, growth, production, storage, barter or sale of cannabis, or any products containing or derived from cannabis, is not permitted in any zone except as otherwise provided in this bylaw. This includes licensed producers regulated under applicable provincial or federal legislation, and cannabis stores. 4.1.6 The use of a modular building as a sales centre may be permitted in any RM, CR or CD zone permitting a multi-family residential, commercial or mixed commercial/residential project, but only when a building permit has been issued for the multi-family residential, commercial or mixed commercial/residential project, and must be removed prior to final approval of the building permit. 4.1.7 The use of a modular building as a construction site office may be permitted in any RM, CR or CD zone permitting a multi-family residential, commercial or mixed commercial/residential project, but only when a building permit has been issued for the multi-family residential, commercial or mixed commercial/residential project, and must be removed prior to final approval of the building permit. 4.1.8 Shipping containers are not permitted as permanent storage units or as ancillary buildings or structures, and may only be located in the City when used for storage purposes for tools and materials during construction when a building permit has been issued, and must be removed prior to final approval of the building permit. Notwithstanding, shipping containers may be used for storage purposes on P-1 zoned lands owned by the City of White Rock. 4.1.9 Accessory off-street parking shall not be used for the parking or storing: (a) of two or more commercial vehicles; (b) of any commercial vehicle exceeding 7.7m (25.26ft) in length; (c) of any contractors equipment or machinery; and/or (d) of house trailers or recreational vehicles, boats or boat trailers, any one of which exceeds 7.7m (25.26ft) in length unless fully concealed from view within an enclosed garage, tarped within an open carport, or tarped and screened from view from a public street by landscaping. Zoning Bylaw No. 2506 Page 18 4.2 Comprehensive Zone Coverage 4.2.1 For the purposes of this Bylaw, all lands and properties within the boundaries of the City of White Rock shall be deemed to have a zone assigned to it. 4.3 Existing Lots of Record 4.3.1 In each zone, all lots that have a lesser lot area, frontage or depth than required herein, and that were registered on a plan in the Land Titles Office prior to the date of adoption of this Bylaw, are established as locations where the minimum lot area, frontage or depth requirements of the zone do not apply, but only to the extent necessary to permit the use of that lot for a use permitted in that zone, and only on the condition that all other requirements of this Bylaw applying in that zone must be observed. 4.4 Construction within an Identified Floodplain 4.4.1 Development within the Campbell River Floodplain and Ocean Floodplain areas as identified in the Official Community Plan require approval for development permit as outlined in the applicable development permit guidelines. 4.4.2 Storage tanks shall be located above the identified flood elevation level, or otherwise: a) be buried and have a water-tight cap; and/or b) be sufficiently anchored to withstand flood waters 4.4.3 Where landfill is required to raise a minimum floor area elevation above the identified flood level for a residential use, the maximum building height permitted may be increased by the equivalent depth of the landfill or difference needed to raise the underside of the floor above the flood level. Where landfill is provided to raise the grades and elevations, the site shall be engineered so as not to adversely impact drainage patterns for adjacent properties. 4.5 Established Building Line 4.5.1 Where a one-unit, two-unit or multi-unit residential building is to be constructed or reconstructed on a lot within a residential zone and where there is an established line of buildings on the same side of the street, such permitted building may be constructed or reconstructed closer to the lot line adjoining the street than permitted by this bylaw such that the front yard or exterior side yard setback is equal to the average front yard or exterior side yard setback of buildings on the same side of the street, provided that such permitted building is not located closer to the lot line adjoining a street than the established building line existing on the date of adoption of this Bylaw. This provision excludes SSMUH Residential Zones. 4.6 Lot Line Setbacks on Strata Lots 4.6.1 The interpretation of front, rear and side yard setbacks for strata lots is dependent on the requirements of the zone applicable to the subject lands, and adjacency to a public road. 4.6.2 Where a strata lot is adjacent to, and access is provided from, a public road, the front, rear and side yard setbacks are determined in the same manner as they are for a fee-simple lot. Zoning Bylaw No. 2506 Page 19 4.6.3 Where a strata lot is provided access from a private or common access lane: a) no front yard setback is required from the strata lot adjacent to the common access lane, however, a minimum 6.0m setback is required between the internal access lane and the front face of the building and opening for a garage or carport; b) the rear yard is interpreted as the part of the lot directly opposite from the strata lot line running parallel with the common access lane; c) all other strata lot lines are interpreted as side lot lines. 4.6.4 In cases where lot widths and lot depths (exclusive of the access area) are equal, or where lot lines are so irregular that proper interpretation cannot be made, the City's Approving Officer may make interpretation regarding the location of front, rear and side yards for the purposes of locating buildings on each bare land strata lot. 4.7 Lot Line Setbacks on Pan-Handle (Fee Simple) Lots 4.7.1 The interpretation of front, rear and side yard setbacks for pan-handle (fee-simple) lots is dependent on the width and depth of the lot exclusive of the access area, where the narrow portion is interpreted as the width of the lot, and the wider portion is interpreted as the depth as shown in the illustration below. Front yard setbacks are only adjacent to a road, rear yard setbacks are interpreted to be behind the building envelope running parallel with the narrower lot lines, and all remaining lot lines are interpreted as side yards, as shown in the illustration below. Zoning Bylaw No. 2506 Page 20 4.7.2 In cases where lot widths and lot depths (exclusive of the access area) are equal, or where lot lines are so irregular that proper interpretation cannot be made, the City's Approving Officer may make interpretation regarding the location of front, rear and side yards for the purposes of siting buildings and structures. 4.8 Building Heights 4.8.1 The height of buildings and structures shall be interpreted as the vertical distance between the highest point of the building or structure and average natural grade, except as indicated for principal buildings in the CR-3 zone. 4.8.2 For the purposes of this Bylaw, average natural grade shall be calculated as the average grade, as determined by measuring the natural grade at the midpoints of the walls on all sides of the building or structure, then divided by the number of all sides, as illustrated below using four sides as an example (the sum of 1, 2, 3 & 4, divided by 4 = ANG). Natural grade shall be determined by a registered BC Land Surveyor and shall be determined as the grades prior to any construction or alteration of the land. Zoning Bylaw No. 2506 Page 21 4.9 Angle of Containment Where angle of containment is required, the height of the southerly elevation of the building shall be determined by an angle of containment of 45 degrees to the vertical commencing 6.0m (19.69ft) above the natural grade at the mid-point of the base for the southerly wall as generally shown below. No part of a building, with the exception of open type balcony guards, shall be placed above the angle of containment. South North 4.10 Floor Area in CD Zones for One-, Two-, and Three-Unit Residential Uses, and in SSMUH Residential Zones 4.10.1 Floor area ratio calculations in all CD zones for one-, two, and three-unit residential uses shall include the sum total of floor areas of each storey in a building for residential use, excluding the following: a) basements b) cellars or crawl spaces c) carports or garages d) bay, bow or box windows e) elevator shafts f) areas on the second storey of a building occupied by stairs 4.10.2 Floor area ratio calculations in all SSMUH Residential Zones shall be measured based on residential gross floor area as defined in Section 3.3, which includes the sum total of floor areas of each storey in a building for residential use, excluding the following: a) crawl spaces; b) carports or garages up to 46.5m2; c) stairwells up to 13m2; d) covered patios and decks up to 37m2; e) elevator shafts. Zoning Bylaw No. 2506 Page 22 4.11 Floor Area in Multi-Unit Residential, Commercial, Public and Mixed Use Zones 4.11.1 Floor area ratio calculations in all multi-unit residential zones (RM) shall be measured based on residential floor area as defined in Section 3.3, which includes the sum total of floor areas of each storey in a building for multi-unit residential use, measured to the midpoint of the exterior walls, including areas occupied by internal walls and partitions, and excluding the following: a) unenclosed balconies b) common stairwells c) elevator shafts d) common corridors e) enclosed parking facilities f) common recreation or amenity areas 4.11.2 Floor area ratio calculations in all commercial or mixed use zones (CR), and public use (P) zones shall be measured based on gross floor area as defined in Section 3.3, which is the sum total of floor areas of each storey in a building, inclusive of exterior walls. 4.11.3 Maximum floor areas in all Comprehensive Development (CD) zones for multi-unit residential, commercial or mixed uses may be based on gross floor area, residential floor area, institutional floor area, or commercial floor area, as defined in Section 3.3, or a combination of the above terms. 4.12 Screening & Fencing 4.12.1 A fence, wall or similar structure over 1.0m (3.28ft) in height shall not be permitted within 4.5m (14.76ft) of an exterior lot corner, as defined by the intersection of an exterior side lot line and a front lot line or a rear lot line, where such lines form an interior angle of 135˚ or less, as illustrated below. 4.12.2 Subject to the provisions of Paragraph 4.12.1 above, and except as otherwise provided for in this Bylaw, a fence: a) may be sited on any portion of a lot; and b) shall not exceed a height of 2.0m (6.56ft). Zoning Bylaw No. 2506 Page 23 4.13 Siting Exceptions and Permitted Projections 4.13.1 Notwithstanding any setback requirements contained in this Bylaw, the following structures may project into the required setback area of all zones, excluding in SSMUH Residential Zones, in accordance with the following restrictions: a) exterior cladding or rain screen wall assembly may project a maximum of 0.115m (0.375ft) into any required setback area; b) exterior architectural design features and cornices may project a maximum of 0.3m (1ft) into any required setback area; c) bay, bow and box windows and cantilevers may project a maximum of 0.6m (2ft) into a front, rear or exterior side yard setback area (but not an interior side yard setback area) provided that such projection shall only apply to the projected feature, shall not comprise more than 3.0m (9.54ft) of linear distance of any wall, and provided that the projected feature is located at least 2.44m (8.0ft) from the front, rear or exterior side lot line; d) freestanding light poles, warning devices, antennas, masts, utility poles, wires, flagpoles, signs and sign structures may be sited on any portion of a lot, except as otherwise limited or restricted by this or other bylaws; e) underground buildings such as an underground parking area may be sited on any portion of a lot, provided that such projections do not extend above grade; and f) structures designed to provide weather protection over the main pedestrian entrance may project a maximum of 1.2m (4ft) into a required front or exterior side yard setback, provided that such structure must be at least 2.44m (8.0ft) from a front or exterior side lot line. g) side mounted balcony guards may project a maximum of 0.15m (0.5 ft) into any required setback area. 4.13.2 In addition to the exceptions noted in Paragraph 4.13.1, and notwithstanding any setback requirements contained in this Bylaw, the following structures may project into the required setback area of all RM zones, in accordance with the following restrictions: a) eaves and gutters may project a maximum of 1.2m (4ft) into any required setback; b) unenclosed balconies may project a maximum of 1.6m (5.25ft) into a required front, rear or exterior side yard setback c) an extension of the principal building or structure designed to provide weather protection over the primary pedestrian entrance, as a porte cochere, may be permitted within the required front or exterior side yard setback areas provided that: d) the height of the extension shall not exceed 4.0 metres (13.12 feet) measured from finished grade; e) no more than one such extension shall be permitted for each principal building; and f) the extension shall not be located within a distance of 10.7 metres (35.10 feet) of a side lot line as illustrated below. ‘‹‰›Žƒ™‘ǤʹͷͲ͸ ƒ‰‡ʹͶ 4.13.3 In addition to the exceptions noted in Paragraph 4.13.1, and notwithstanding any setback requirements contained in this Bylaw, the following structures may project into the required setback area of any SSMUH Residential Zones only, in accordance with the following restrictions: a) eaves and gutters, may project a maximum of 0.6m (2ft) into a required interior side yard setback, and 1.2m (4ft) into a required front, rear or exterior side yard setback, provided that where an exterior side yard setback required is less than 3.0m (9.84ft), the maximum projection permitted is 0.6m (2ft); and b) mechanical equipment is prohibited from projecting into any required front and side yard setback. 4.13.4 The heights of buildings and structures permitted elsewhere in this Bylaw may be exceeded for: elevator shafts and stair towers that do not provide direct access to the roof; for antennas; for church spires, belfries and domes; for chimneys; for flag poles; and, for monuments; but no such structure shall cover more than 20 percent of the lot or, if located on a building, no more than 10 percent of the roof area of the building. 4.13.5 Notwithstanding Paragraph 4.13.4, the heights of buildings and structures in all SSMUH Residential Zones, inclusive of stair towers and elevator shafts that do provide direct access to the roof, shall not exceed the maximum height prescribed under the applicable zone. 4.13.6 In the RM-1, RM-2 and RM-3 zones only, where solar panels or other green energy technologies are installed on or within a roof, the maximum height of buildings and structures permitted elsewhere in this Bylaw may be exceeded for solar heating panels by not more than 2.2m (7.22ft). 4.14 Off-Street Parking Requirements 4.14.1 Unless otherwise indicated in this Bylaw, off-street parking spaces must be provided and maintained in accordance with the following standards: Development Type or Use Required Parking Spaces RESIDENTIAL USES One-unit residential Two-unit residential Three-unit residential Townhouse 2 per dwelling unit Principal Building 10.7m min. 10.7m min. Location of structure Side lot lines ‘‹‰›Žƒ™‘ǤʹͷͲ͸ ƒ‰‡ʹͷ Semi-detached residential building Rowhouse residential building House-Plex (if located outside the 400m radius from a prescribed bus stop) 1 per dwelling unit up to and including 3 dwelling units. 0.75 per dwelling unit over 3 dwelling units up to and including 6 Semi-detached residential building Rowhouse residential building House-Plex (if located within the 400m radius from a prescribed bus stop) Not applicable Accessory Registered Secondary Suite excluding within House-plex dwelling unit. Accessory Dwelling Unit excluding House- plex dwelling units. Short term rental 1 per dwelling unit Accessory bed & breakfast Accessory boarding use 1 per sleeping unit Apartment 1.2 per dwelling unit, plus 0.3 per dwelling unit for visitor parking, for a total of 1.5 spaces per dwelling unit Community Care Facility 1 per 5 units plus 1 for every 2 employees Accessory Child Care Centre 2 spaces for pick-up and drop-off plus 1 for every 2 employees COMMERCIAL USES Commercial - retail 1 per every 37m² of commercial (retail) floor area, except 1 per 74m² of commercial (retail) floor area for lots fronting onto Marine Drive Commercial - office 1 per every 37m² of commercial (office) floor area, except 1 per 74m² of commercial (office) floor area for lots fronting onto Marine Drive Commercial - restaurant or licensed establishment 1 per every 8 seats available for customer use, except 1 per every 16 seats for lots fronting onto Marine Drive Hotel / Motel 1 per sleeping unit INSTITUTIONAL & CULTURAL USES Civic use, Recreational use 1 per every 37m² of institutional floor area used for a civic or recreational use. For 1174 Fir Street only (lot 1, Block 30, Plan 11883), 6 parking spaces total for professional and semi-professional office use. Assembly use 1 per every 46m² of institutional floor area used for an assembly use Elementary school 1 per every 92m² of institutional floor area Hospital 1 per 5 patient beds Child Care Centre 1 per every 3 employees, plus 2 spaces for pick-up and drop-off ‘‹‰›Žƒ™‘ǤʹͷͲ͸ ƒ‰‡ʹ͸ 4.14.2 Notwithstanding Paragraph 4.14.1 above, developments existing prior to the adoption of this Bylaw shall be considered acceptable provided that there are no changes in the use or increases in the floor area and/or density of the development. If there is a change of use or increase in floor area or density, an existing development will be required to comply with the parking requirements outlined in Paragraph 4.14.1. 4.14.3 The minimum on-site parking requirements outlined in Paragraph 4.14.1 above may be reduced by up to a maximum of 10% where: a) transportation demand management measures, including the use of car co- operatives, or car-share programs, are provided, and b) the reduction in minimum on-site parking requirements is substantiated by a parking study that is prepared by a registered professional engineer and is subject to review and approval by the City; and c) the proponents offer and enter into a covenant to require continuation of the transportation demand management measure. 4.14.4 Where a building or structure is used for more than one permitted use, the required number of parking spaces shall be interpreted as the sum of the requirements for each use. 4.14.5 Notwithstanding Paragraph 4.14.4 above, shared on-site parking areas for two (2) or more uses may be permitted where: a) the maximum demand for such parking areas by the individual uses occurs at different periods of the day; b) the maximum demand of such parking areas is substantiated by a parking study that is prepared by a registered professional engineer and is subject to review and approval by the City; and c) the proponents offer and enter into a covenant to restrict any change of use or occupancy that would adversely affect the continuation of the shared on-site parking arrangement. 4.14.6 Accessible Parking: 1) Accessible Parking Dimensions: a) Accessible parking spaces shall have a minimum length of 5.5m and a minimum width of2.5m. b) Van-accessible parking spaces shall have a minimum length of 5.5m and a minimum width of 3.4m. c) The access and egress route to and from accessible and van-accessible parking spaces must have a minimum vertical clearance of 2.3m. d) Accessible parking spaces and van-accessible parking spaces shall have an adjacent access aisle on one side with a minimum width of 1.5m that may be shared between two adjacent accessible and I or van-accessible parking spaces. e) A wheel stop shall be placed 0.6m from the end of each accessible and van-accessible parking spaces. 2) Accessible Parking Supply: a) Accessible and van-accessible parking spaces shall be provided in accordance with the following supply requirements: ‘‹‰›Žƒ™‘ǤʹͷͲ͸ ƒ‰‡ʹ͹ Total Required Parking Spaces Minimum Required Van- Accessible Minimum Required Accessible Spaces 5 or less 0 0 6 to 50 1 0 51 to 100 1 1 101 to 150 2 1 151 to 200 2 2 Over 200 5 plus 1 for every additional!00 required parking spaces or fraction thereof. - "When the required accessible space· supply is an even number there must be an equal number of van-accessible spaces to standard accessible spaces. - "When the required accessible space supply is an odd number there should be one additional van-accessible space than standard accessible spaces. 3) Accessible Parking Dimensions and Layout The dimensions and layout of accessible parking shall comply with the following: ‘‹‰›Žƒ™‘ǤʹͷͲ͸ ƒ‰‡ʹͺ 4.14.7 In the calculation of required parking, where the calculation results in a fraction of a parking space, one (1) off-street parking space shall be provided to meet the fractional requirement. 4.14.8 Minimum parking space dimensions shall be as follows: Angle Width Length Depth to Curb Aisle Width Traffic Direction 30˚ 2.7m 5.2m 5.2m 3.5m 1-way 45˚ 2.7m 5.2m 6.0m 3.9m 1-way 60˚ 2.7m 5.2m 6.4m 5.0m 1-way 90˚ 2.7m 5.8m 5.8m 6.7m 1- or 2-way Parallel Parking 2.5m 7.0m 2.5m 3.5m 6.0m 1-way 2-way 4.14.9 Small car spaces may be provided to a maximum portion of 40% of the total parking required, shall have a minimum width of 2.5m and minimum length of 5.2m, and shall be clearly marked for small car use only. 4.15 Off-Street Loading Requirements 4.15.1 Additional spaces must be provided for the temporary stopping, loading and unloading of vehicles for every commercial site, place of public assembly, hospital, institution, school, or club. The minimum number of loading spaces in addition to the parking space requirements of Paragraph 4.14.1 above, are as follows: Commercial / Institutional Floor Area Required Loading Spaces < 500m² 1 loading space 500-2000m² 2 loading spaces 2001-3500m² 3 loading spaces >3500m² 1 additional loading space for every additional 5000m² of commercial / institutional floor area 4.15.2 Notwithstanding the above, a minimum of one (1) off-street loading space shall be provided for every apartment complex, assisted-living complex and care facility containing more than ten (10) dwelling units or living units. Where the apartment complex, assisted-living complex or care facility is provided in more than one principal building with separate elevators for each building, one (1) off-street loading space shall be provided for each principal building containing more than ten (10) dwelling units or living units. 4.15.3 Loading spaces shall have a minimum width of 3.0m, a minimum length of 9.0m and a minimum clearance height of 3.7m. Zoning Bylaw No. 2506 Page 29 4.16 Bicycle Parking 4.16.1 On-site bicycle parking areas should be considered for all new commercial, institutional and multi-family developments and, when provided, should be designed as an integral part of the overall site plan addressing concerns of topography and ease of access. 4.16.2 On-site bicycle parking areas should be designed in accordance with the following: a) Class I - long-term secured bicycle parking provided in the form of waterproof bicycle lockers, secured bicycle rooms, or secured compounds within a building complete with bicycle racks. Class I bicycle parking areas should be located at grade, within sight of the building entry or security room, and have the following minimum dimensions: Vertical Clearance Width Length (if placed horizontally) Length (if placed vertically) 1.9m 0.6m 1.8m 1.0m Where waterproof bicycle lockers are provided, the following minimum dimensions apply: Length Height End width at door End width opposite door 1.8m 1.2m 0.6m 0.22m b) Class II - short-term bicycle parking should be provided in the form of bicycle racks, made of sturdy, theft-resistant material and should be securely anchored to the floor or ground, designed to support the bicycle frame, not the wheels. Class II parking areas should be clearly visible from the principal building entry points or roads. 4.16.3 On-site bicycle parking areas should be provided as follows: Use Class I Class II Apartment, Townhouse 1 space per dwelling unit 0.2 spaces per dwelling unit Commercial - retail 0.25 spaces per 200m² gross floor area 0.75 spaces per 200m² gross floor area Commercial - office 0.75 spaces per 200m² gross floor area 0.25 spaces per 200m² gross floor area Civic, assembly, recreation, education uses 0.25 spaces per 200m² gross floor area 0.75 spaces per 200m² gross floor area Community Care Facility, Hospital 0.25 spaces per 200m² gross floor area 0.75 spaces per 200m² gross floor area 4.17 Provision of Electric Vehicle Charging Infrastructure 4.17.1 For new buildings that include multi-unit residential uses, a minimum of 1 of every 10 off- street parking spaces shall feature an energized outlet capable of providing Level 2 charging or higher to the off-street parking space. Zoning Bylaw No. 2506 Page 30 An additional 1 of every 10 off-street parking spaces shall feature roughed-in electric vehicle charging infrastructure, including an electrical outlet box located within 3 metres of the parking space. Where more than 1 of every 10 off-street parking spaces features an energized outlet capable of providing Level 2 charging or higher is provided, the minimum number of off- street parking spaces featuring roughed-in electric vehicle charging infrastructure may be reduced by the number of off-street parking spaces that feature the energized outlets beyond the minimum requirement. This section does not apply to new buildings with fewer than 10 off-street parking spaces. 4.17.2 Energized outlets, provided pursuant to Section 4.17.1 above, shall be labelled for their intended use for electric vehicle charging. 4.17.3 Where an electric vehicle management energy system is implemented, the Director of Engineering may specify a minimum performance standard to ensure a sufficient rate of electric vehicle charging. 4.18 Basements 4.18.1 Basement Related Depressions a) Only one (1) localized depression for basement access is permitted per one-unit residential use; semi-detached residential building; rowhouse residential building or house-plex. In addition, one localized depression for basement access for a accessory registered secondary suite is permitted. b) Only one (1) set of stairs is permitted per localized depression for basement access. c) The aggregate area of a localized depression for basement access shall not exceed 12m2 and 40% of the corresponding wall length including the stairs, measured from the interior of the required retaining walls. d) A localized depression for basement access is not permitted in the required front and any side yard setback. e) Where a localized depression for basement access is located below a spanning structure from the first storey to the ground level, the depression shall be located such that the spanning structure is open to below on only one side. f) Window wells are permitted on any side of a one-unit residential use; semi-detached residential building; rowhouse residential building or house-plex provided they do not extend more than 0.9m beyond the building wall face, are no more than 1.5m deep, and do not exceed 25% of the corresponding wall length. 4.19 Maximum Ceiling Height for SSMUH Zones 4.19.1 Any portion of residential gross floor area in a dwelling unit with a ceiling height which exceeds 5.0m shall be considered to comprise two floors and shall be measured as such for the purpose of calculating residential gross floor area. Zoning Bylaw No. 2506 Page 31 5.0 Specific Use Provisions & Regulations 5.1 Community Care Facilities 5.1.1 Child Care Centres: 1) An accessory child care centre shall be permitted as an accessory use to a one-unit residential use in all SSMUH Residential Zones, provided that: a) child care is provided for no more than eight (8) children; b) child care is provided within the personal residence of the licensee; c) the accessory child care centre has a valid license issued in accordance with the Community Care and Assisted Living Act and Child Care Licensing Regulation as amended; d) the accessory child care centre has a valid business license; and e) the accessory child care centre meets the off-street parking requirements in Section 4.14.1. 2) A child care centre providing care for more than eight (8) children is permitted in the CR-1, CR-2, CR-3, CR-4, CR-5 zones and in all P zones, provided that: a) the child care centre has a valid license issued in accordance with the Community Care and Assisted Living Act and Child Care Licensing Regulation as amended; b) the child care centre has a valid business license; c) the child care centre meets the off-street parking requirements in Section 4.14.1; and d) the outdoor play area required for the child care centre under the Child Care Licensing Regulation is located on the same lot as the child care centre. 5.1.2 Care Facilities: 1) A care facility used as a residence for no more than ten (10) persons, not more than six (6) of whom are persons in care, is permitted in all SSMUH Residential Zones with a one-unit residential use only provided that: a) the care facility has a valid license issued in accordance with the Community Care and Assisted Living Act and Regulations as amended; b) the care facility has a valid business license; and c) shall be located not closer than 300.0 metres (984.25 feet) from any other care facility. 2) A care facility used as a residence for more than six (6) persons in care is permitted in all P zones and in all CD zones specifically permitting a care facility, provided that: a) the care facility received approval for development permit if developed, redeveloped or expanded after September 2008; b) the care facility has a valid license issued in accordance with the Community Care and Assisted Living Act and Regulations as amended; and c) the care facility has a valid business license. Zoning Bylaw No. 2506 Page 32 5.2 Community Services 5.2.1 Community services may be permitted in any CR or CS zone, any P zone, and any CD zone that permits a commercial use. 5.3 Accessory Home Occupation Use 5.3.1 An accessory home occupation use is permitted in all zones permitting a residential use, but only in accordance with the following provisions: 1) it shall be completely enclosed within the building used for the residential use to which it is accessory, and shall not occupy more than 40% of the residential gross floor area of a dwelling unit; 2) the wholesale or retail sale of any goods or materials from the dwelling unit is not permitted; 3) within all RM (multiple-unit zones), mixed commercial/residential zones, or SSMUH Residential Zones containing an accessory bed and breakfast use or a short term rental, no home occupation shall be permitted which involves clients directly accessing the building; 4) within SSMUH Residential Zones in which the parcel of land contains more than 2 dwelling units, one of which is a registered secondary suite, or an accessory dwelling unit, the only type of home occupation permitted in the dwelling units will be limited to a home office only. All other Accessory Home Occupation Use regulations will apply; 5) there shall be no exterior storage or display of goods or materials; 6) the home occupation use shall be clearly incidental to the residential use of the building; 7) there shall be no alteration to the exterior appearance of the property to indicate that a home occupation is being conducted except for one non-illuminated sign in accordance with the requirements of the City's Sign Bylaw; 8) the premises shall not be used for any assembly related uses or occupancies, or for any use that generates noise, vibration, dust, odours, vapours, heat, on-street parking or vehicular traffic other than that normally associated with a residential dwelling; 9) it shall be conducted only by the resident of the residential use to which it is accessory, and not more than one resident or non-resident employee; 10) all home occupation uses will be required to possess a valid business license; 11) no business license will be issued any applicant for home occupation use unless the City has been provided with written consent by the Owner or the Owner's Agent as authorized in writing by the Owner; 12) parking for the home occupation use shall be provided totally upon the site, in addition to that required for the principal residential use. No more than one additional off-street parking space for the home occupation will be permitted. Any additional spaces shall be provided totally enclosed within the structure. Zoning Bylaw No. 2506 Page 33 5.4 Accessory Boarding Use 5.4.1 An accessory boarding use shall only be permitted in all SSMUH Residential zones, and shall: a) be accessory to a residential use; b) be completely enclosed within the principal dwelling; c) be limited to a maximum of two sleeping units per dwelling unit and a maximum of four (4) boarding guests; d) not provide separate cooking facilities for the accessory boarding use; e) provide one additional on-site parking space per sleeping unit; f) shall only be permitted in an owner-occupied dwelling unit; g) shall only accommodate boarders or roomers for periods of 30 days or greater. 5.5 Accessory Registered Secondary Suite 5.5.1 An accessory registered secondary suite shall only be permitted in all SSMUH Residential Zones, and shall: a) be an accessory to a one-unit residential use; semi-detached residential building or rowhouse residential building only; b) be limited to one accessory registered secondary suite per lot; c) conform with the BC Building Code requirements and limited to a maximum of 90 square metres residential gross floor area and not more than two (2) bedrooms; d) provide one additional on-site parking space for occupants of the accessory registered secondary suite; e) be inspected and registered through the City's Secondary Suite Registration process; and f) only accommodate tenants for periods of ninety (90) days or greater. 5.6 Accessory Dwelling Unit 5.6.1 An accessory dwelling unit shall only be permitted in the zones where specifically permitted, and shall: a) be an accessory to a one-unit residential use; semi-detached residential building; or rowhouse residential building only; b) be allowed only where secondary access can be provided from a lane, or common access lane in a bare land strata development. If section 5.6.1.b) cannot be provided, then the following access applies: i) Entrances to accessory dwelling units must be connected to a street by an unobstructed, hard-surfaced path at least 1.0 m wide, with lighting that does not spill over onto neighbouring properties. c) be allowed over garages or carports to allow accessory dwelling units in ancillary building; d) be allowed a vestibule (entrance foyer and stairway) on the main (garage or carport) level to reflect situations where an accessory dwelling unit is situated above a garage; e) require address numbers to be posted on the accessory dwelling unit building near the primary entrance, in a colour contrasting with the building, and either illuminated in periods of darkness or reflective for easy visibility at night. When building addresses are not visible from the street frontage, directional address signs are required. Zoning Bylaw No. 2506 Page 34 5.7 Accessory Bed & Breakfast Use 5.7.1 An accessory bed & breakfast use shall: a) only be permitted in a principal building containing a one-unit residential use; b) not provide separate cooking facilities or equipment for the accessory bed & breakfast use; c) install fire extinguishers, interconnected smoke and carbon monoxide alarms, and emergency lighting in hallways and egress points, to B.C. Building Code standards; d) be limited to a maximum of three (3) sleeping units; e) be limited to no more than six (6) guests at any given time; f) provide one (1) off-street parking space for each sleeping unit, pursuant to Section 4.14; g) not create any form or manner of nuisance for neighbouring properties, including but not limited to noise, light, traffic or on-street parking; h) have a valid business license (no business license will be issued any applicant for an accessory bed & breakfast use unless the City has been provided with written consent by the Owner or the Owner's Agent as authorized in writing by the Owner); and i) only provide for the temporary accommodation of any number of guests for periods not to exceed thirty (30) days. 5.8 Short Term Rental 5.8.1 A short term rental use shall: a) only be operated from an accessory registered secondary suite that complies with all applicable BC Building Code requirements; b) only be operated by an owner (or immediate family member of the owner) of the subject property, where they are a full-time resident and occupant of the one- residential use. A tenant may not sublet the accessory registered secondary suite for this purpose; c) only be operated if the owner has designated a responsible person whose name and contact information is prominently displayed in the short term rental premises at all times when the short term rental is operated, who, at all times that the short-term rental is operated, has access to the premises and authority to make decisions in relation to the premises and the rental agreement, and who must be able to attend at the short- term rental premises within two hours of being requested to do so; d) install fire extinguishers, interconnected smoke and carbon monoxide alarms, and emergency lighting in hallways and egress points, to B.C. Building Code standards; e) not permit any structural alteration or addition that changes the residential character and form of the principal building; f) be limited to a maximum of two (2) sleeping units only; g) be limited to no more than four (4) adult guests at any given time; h) not be occupied by more than one booking or reservation at any given time; i) not have any exterior signage advertising the short term rental use; j) provide accessory off-street parking in accordance with the provisions of Section 4.14; k) not create any form or manner of nuisance for neighbouring properties, including but not limited to noise, light, traffic or on-street parking; Zoning Bylaw No. 2506 Page 35 l) have a valid business license, and display the business licence number in all advertising for the short term rental; m) only provide for the temporary accommodation of guests for periods not to exceed ninety (90) days. 5.9 Community Gardens 1) A community garden shall be permitted in all P zones, in the CR-1, CR-2, CR-3, CR- 4, CR-5 zones, and in all CD zones, provided that: a) for CD zones, there shall be no other buildings or structures for other uses present on the lot; b) any non-profit society or community organization operating the community garden shall have a valid business licence (no business license will be issued to an applicant for any community garden unless the City has been provided with written consent by the Owner or the Owner's Agent as authorized in writing by the Owner, including identifying the terms for when the community garden is to cease); and c) the cultivation of cannabis, or any invasive or illegal species does not occur as part of the community garden use. Zoning Bylaw No. 2506 Page 36 6.0 General Zones - Uses Permitted & Zone Provisions 6.1 RS-1 SSMUH Residential Zone The intent of this zone is to provide for the development of up to four dwelling units on a single parcel of land that is located outside of a 400m radius from a prescribed bus stop, or six units within a 400m radius from a prescribed bus stop, on a single parcel of land within the urban containment boundary, in a variety of building forms. 6.1.1 Permitted Principal Uses: 1) Only one (1) of the following principal use is permitted on a parcel of land: a) a one-unit residential use with a minimal parcel size of 742m2; b) house-plex with a minimal parcel size of 742m2, and no basements are permitted if the house-plex contains only two dwelling units; c) semi-detached residential building; or d) rowhouse residential building. 6.1.2 Permitted Accessory Uses: Principal Uses Permitted Accessory Uses 1) One-unit residential use A) Only one (1) of the following accessory uses is permitted: a. an accessory child care centre in accordance with the provisions of Section 5.1. b. an accessory boarding use in accordance with the provisions of Section 5.4. c. an accessory registered secondary suite that can include an accessory home occupation use in accordance with the provisions of Sections 5.3 and 5.5. d. an accessory dwelling unit that can include an accessory home occupation use in accordance with the provisions of Sections 5.3 and 5.6. e. an accessory bed & breakfast use in accordance with the provisions of Section 5.7. f. a short term rental in accordance with the provisions of Section 5.8. g. an accessory home occupation in accordance with the provisions of Section 5.3 h. a care facility in accordance with the provisions of Section 5.1. Zoning Bylaw No. 2506 Page 37 B) Exceptions - The following accessory uses can be permitted together: a. an accessory registered secondary suite that can include a home occupation use in accordance with the provisions of Sections 5.3 and 5.5; b. an accessory dwelling unit that can include a home occupation use in accordance with the provisions of Sections 5.3 and 5.6; and c. an accessory home occupation in accordance with the provisions of Section 5.3. 2) House-plex Only the following accessory use is permitted: a. an accessory home occupation in accordance with the provisions of Section 5.3. 3) Semi-detached residential building The following accessory uses can be permitted together: a. an accessory registered secondary suite that can include a home occupation use in accordance with the provisions of Sections 5.3 and 5.5; b. an accessory dwelling unit that can include a home occupation use in accordance with the provisions of Sections 5.3 and 5.6; and, c. an accessory home occupation in accordance with the provisions of Section 5.3. 4) Rowhouse residential building The following accessory uses can be permitted together: a. an accessory registered secondary suite in accordance with the provisions of Section 5.5. b. an accessory dwelling unit is only permitted on lots that only have zero side yard setbacks on one side yard, or if there is a rear lane abutting the lot, then each lot is permitted an accessory dwelling unit that can include an accessory home occupation use in accordance with the provisions of Sections 5.3 and 5.6; and, c. an accessory home occupation in accordance with the provisions of Sections 5.3. Zoning Bylaw No. 2506 Page 38 6.1.3 Lot Dimensions for Subdivision: 1) Lots created through subdivision in the RS-1 SSMUH Residential Zone must conform to the following minimum standards: Lot With Minimum Lot Depth Minimum Minimum Lot Area Lots created in the RS-1 SSMUH zone, except for semi-detached residential buildings and rowhouse residential buildings. 18.0m (59.04ft) 30.5m (100.06ft) 742m2 (7,986.82 ft2) Lots created in the RS-1 SSMUH zone for Semi-detached residential buildings and rowhouse residential building 9.0m (29.52ft) 30.5m (100.06ft) 274.5m2 (2,954.69 ft2) 6.1.4 Lot Coverage: 1) The maximum lot coverage is 40%. 6.1.5 Permitted Density: 1) The maximum permitted number of dwelling units on a parcel of land based on minimum lot area and location of a prescribed bus stop: a) Outside 400m radius from a prescribed bus stop i) Lots greater than 280m2 and less than 4,050m2 Up to 4 dwelling units ii) Lots less than 280m2 up to 3 dwelling unit b) Within 400m radius from a prescribed bus stop i) Lots at least 281m2 or greater Up to 6 dwelling units ii) Lots less than 280m2 up to 3 dwelling unit 6.1.6 Floor Area: 1) maximum residential gross floor area shall not exceed 0.75 times the lot area for a maximum of 6 dwelling units on a parcel of land. 2) maximum permitted floor area of a 2nd storey for a principal building shall not exceed 80% of the footprint for the 1st storey including the attached garage and that portion of any covered porch, deck or carport. 6.1.7 Landscape Requirements: 1) The maximum impermeable surface area on the parcel of land is 70%; Zoning Bylaw No. 2506 Page 39 2) The minimum permeable surface area on the parcel of land is 30%, of which 50% at minimum will contain live plant material; 3) 50% of the required front yard will be landscaped with live plant material including a 1.2m (3.94ft) permeable landscape strip containing live plant material on either side of the driveway; and 4) The owner of the property is responsible for the placement and proper maintenance of landscaping. 6.1.8 Building Heights: 1) principal buildings shall not exceed a height of 7.7m (25.26ft). 2) accessory dwelling unit shall not exceed a height of 7.0m (22.97ft) for a building with a minimum roof slope of 6:12, and shall not exceed a height of 6.0m (19.69ft) for a building with any lesser roof slope. 3) ancillary buildings and structures shall not exceed a height of 5.0m (16.40ft). 6.1.9 Minimum Setback Requirements: 1) principal buildings and ancillary buildings and structures in the RS-1 SSMUH Residential Zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Building - Except semi- detached residential building and rowhouse residential building Principal Building - Semi-detached residential building and rowhouse residential building Ancillary Buildings, Structures, or Accessory Dwelling Unit Front lot line 6.0m (19.69ft) 6.0m (19.69ft) Not Permitted Rear lot line 6.0m (19.69ft) 6.0m (19.69ft) 1.5m (4.92ft) Rear lot line on a lot with an exterior side yard requirement of 3.8m (12.47ft.), where the rear lot line abuts the interior side lot line of an adjacent residential lot 3.8m (12.47ft) 3.8m (12.47ft) 1.5m (4.92ft) Interior side lot line 1.5m (4.92ft) 0.0m 1 1.5m (4.92ft) Interior side lot line (abutting a lane) 2.4m (7.87ft) 0.0m 2 2.4m (7.87ft) Exterior side lot line (where the rear lot line abuts a lane, or where the rear lot line abuts the rear lot line of an adjacent residential lot or abutting an 2.4m (7.87ft) 2.4m (7.87ft) 2.4m (7.87ft) Zoning Bylaw No. 2506 Page 40 interior or rear lot line for a commercial use) Exterior side lot line (where the rear lot line abuts the interior side lot line of an adjacent residential lot) 3.8m (12.47ft) 3.8m (7.87ft) 1.5m (4.92ft) 1 The interior side lot line setback of a semi-detached residential building and rowhouse residential building shall be increased to a minimum of 1.5m (4.92ft) on the opposite side of the lot to the party wall. If there is a party wall on either side of the interior side lot line, then the interior side lot line setback is 0.0m. 2 The interior side lot line (abutting a lane) setback of a semi-detached residential building and rowhouse residential building shall be increased to a minimum of 2.4m (7.87ft) on the opposite side of the lot to the party wall. If there is a party wall on either side of the interior side lot line (abutting a lane), then the interior side lot line (abutting a lane) is 0.0m 6.1.10 Ancillary Buildings and Structures or Accessory Dwelling Units: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.1.8 and 6.1.9 above, the following also applies: 1) there shall be not more than one ancillary building per lot. 2) ancillary buildings or structures shall not be located in any required front yard or exterior side yard area. 3) ancillary buildings or structures shall not be sited less than 3.0m (9.84ft) from a principal building on the same lot. 4) accessory dwelling units shall not be located in any required front yard or exterior side yard area. 5) accessory dwelling units shall be located not less than 3.0m (9.84ft) from a principal building. 6.1.11 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. Zoning Bylaw No. 2506 Page 41 6.2 RS-2 SSMUH Residential Zone The intent of this zone is to provide for the development of up to four dwelling units on a single parcel of land that is located outside of a 400m radius from a prescribed bus stop, or six units within a 400m radius from a prescribed bus stop, on a single parcel of land within the urban containment boundary, in a variety of building forms. 6.2.1 Permitted Principal Uses: 1) Only one (1) principal use is permitted on a parcel of land: a) a one-unit residential use; b) house-plex; c) semi-detached residential building; or d) rowhouse residential building 6.2.2 Permitted Accessory uses: Principal Uses Permitted Accessory Uses 1) One-unit residential use A) Only one (1) of the following accessory uses is permitted: a. an accessory child care centre in accordance with the provisions of Section 5.1. b. an accessory boarding use in accordance with the provisions of Section 5.4. c. an accessory registered secondary suite that can include an accessory home occupation use in accordance with the provisions of Sections 5.3 and 5.5. d. an accessory dwelling unit that can include an accessory home occupation use in accordance with the provisions of Sections 5.3 and 5.6. e. an accessory bed & breakfast use in accordance with the provisions of Section 5.7. f. a short term rental in accordance with the provisions of Section 5.8. g. an accessory home occupation in accordance with the provisions of Section 5.3 h. a care facility in accordance with the provisions of Section 5.1. B) Exceptions - The following accessory uses can be permitted together: a. an accessory registered secondary suite that can include a home occupation use in accordance with the provisions of Sections 5.3 and 5.5; b. an accessory dwelling unit that can include a home occupation use in accordance with the provisions of Sections 5.3 and 5.6; and Zoning Bylaw No. 2506 Page 42 c. an accessory home occupation in accordance with the provisions of Section 5.3. 2) House-plex Only the following accessory use is permitted: a. an accessory home occupation in accordance with the provisions of Section 5.3. 3) Semi-detached residential building The following accessory uses can be permitted together: a. an accessory registered secondary suite that can include a home occupation use in accordance with the provisions of Sections 5.3 and 5.5; b. an accessory dwelling unit that can include a home occupation use in accordance with the provisions of Sections 5.3 and 5.6; and, c. an accessory home occupation in accordance with the provisions of Section 5.3. 4) Rowhouse residential building The following accessory uses can be permitted together: a. an accessory registered secondary suite in accordance with the provisions of Section 5.5. b. an accessory dwelling unit is only permitted on lots that only have zero side yard setbacks on one side yard, or if there is a rear lane abutting the lot, then each lot is permitted an accessory dwelling unit that can include an accessory home occupation use in accordance with the provisions of Section 5.3 and 5.6; and, c. an accessory home occupation in accordance with the provisions of Section 5.3. 6.2.3 Lot Dimensions for Subdivision: 1) Lots created through subdivision in this RS-2 SSMUH Residential Zone must conform to the following minimum standards: Lot With Minimum Lot Depth Minimum Minimum Lot Area Lots Created in the RS-2 zone, except for semi-detached residential buildings and rowhouse residential buildings 12.1m (39.7ft) 27.4m (89.9ft) 410m2 (4,413.20 ft2) Lots Created in the RS-2 zone for Semi-detached residential buildings and Rowhouse residential buildings 6.05m (19.84ft) 27.4m (89.9ft) 205m2 (2,206.60 ft2) Zoning Bylaw No. 2506 Page 43 6.2.4 Lot Coverage: 1) The maximum lot coverage is 45%. 6.2.5 Permitted Density: 1) The maximum permitted number of dwelling units on a parcel of land based on minimum lot area and location of a prescribed bus stop: a) Outside 400m radius from a prescribed bus stop i) Lots greater than 280m2 and less than 4,050m2 Up to 4 dwelling units ii) Lots less than 280m2 up to 3 dwelling units b) Within 400m radius from a prescribed bus stop i) Lots at least 281m2 or greater Up to 6 dwelling units ii) Lots less than 280m2 up to 3 dwelling units 6.2.6 Floor Area: 1) maximum residential gross floor area shall not exceed 0.75 times the lot area for a maximum of up to 2 dwelling units on a parcel of land. 2) maximum residential gross floor area shall not exceed 0.85 times the lot area for above 2 dwelling units to a maximum of 4 dwelling units on a parcel of land. 3) maximum residential gross floor area shall not exceed 0.95 times the lot area for above 4 dwelling units to a maximum of 6 dwelling units on a parcel of land. 6.2.7 Landscape Requirements: 1) The maximum impermeable surface area on the parcel of land is 70%; 2) The minimum permeable surface area on the parcel of land is 30%, of which 50% at minimum will contain live plant material; 3) 50% of the required front yard will be landscaped with live plant material including a 1.2m (3.94ft) permeable landscape strip containing live plant material on either side of the driveway; and 4) The owner of the property is responsible for the placement and proper maintenance of landscaping. 6.2.8 Building Heights: 1) principal buildings shall not exceed a height of 7.7m (25.26ft). 2) accessory dwelling unit shall not exceed a height of 7.0m (22.97ft) for a building with a minimum roof slope of 6:12, and shall not exceed a height of 6.0m (19.69ft) for a building with any lesser roof slope. 3) ancillary buildings and structures shall not exceed a height of 5.0m (16.40ft). Zoning Bylaw No. 2506 Page 44 6.2.9 Minimum Setback Requirements: 1) principal buildings and ancillary buildings and structures in the RS-2 SSMUH Residential Zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Building - Except semi- detached residential building and rowhouse residential building Principal Building - Semi-Detached Residential Building and Rowhouse Residential building Ancillary Buildings, Structures, or Accessory Dwelling Unit Front lot line 6.0m (19.69ft) 6.0m (19.69ft) Not Permitted Rear lot line 6.0m (19.69ft) 6.0m (19.69ft) 1.5m (4.92ft) Rear lot line on a lot with an exterior side yard requirement of 3.8m (12.47ft.), where the rear lot line abuts the interior side lot line of an adjacent residential lot 3.8m (12.47ft) 3.8m (14.47ft) 1.5m (4.92ft) Interior side lot line 1.2m (3.94ft) 0.0m 1 1.2m (3.94ft) Interior side lot line (abutting a lane) 2.4m (7.87ft) 0.0m 2 1.5m (4.92ft) Exterior side lot line (where the rear lot line abuts a lane, or where the rear lot line abuts the rear lot line of an adjacent residential lot or abutting an interior or rear lot line for a commercial use) 2.4m (7.87ft) 2.4m(7.87ft) 2.4m (7.87ft) Exterior side lot line (where the rear lot line abuts the interior side lot line of an adjacent residential lot) 3.8m (12.47ft) 3.8m (12.47ft) 1.5m (4.92ft) 1 The interior side lot line setback of a semi-detached residential building and rowhouse residential building shall be increased to a minimum of 1.2m (3.92ft) on the opposite side of the lot to the party wall. If there is a party wall on either side of the interior side lot line, then the interior side lot line setback is 0.0m. 2 The interior side lot line (abutting a lane) setback of a semi-detached residential building and rowhouse residential building shall be increased to a minimum of 2.4m (7.87ft) on the opposite side of the lot to the party wall. If there is a party wall on either side of the interior side lot line (abutting a lane), then the interior side lot line (abutting a lane) is 0.0m. Zoning Bylaw No. 2506 Page 45 6.2.10 Ancillary Buildings and Structures or Accessory Dwelling Units: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.2.8 and 6.2.9 above, the following also applies: 1) there shall be not more than one ancillary building per lot. 2) ancillary buildings or structures shall not be located in any required front yard or exterior side yard area. 3) ancillary buildings and structures shall not be sited less than 3.0m (9.84ft) from a principal building on the same lot. 4) accessory dwelling units shall not be located in any required front yard or exterior side yard area. 5) accessory dwelling units shall be located not less than 3.0m (9.84ft) from a principal building. 6.2.11 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. Zoning Bylaw No. 2506 Page 46 6.3 RS-3 (Small lot, Hillside) SSMUH Residential Zone The intent of this zone is to provide for the development of up to four dwelling units on a single parcel of land that is located outside of a 400m radius from a prescribed bus stop, or six units within a 400m radius from a prescribed bus stop, on a single parcel of land within the urban containment boundary, in a variety of building forms. 6.3.1 Permitted Principal Uses: 1) Only one (1) principal use is permitted on a parcel of land: a) a one-unit residential use; or, b) house-plex 6.3.2 Permitted Accessory Uses: 1) In conjunction with a one-unit residential use not more than one (1) of the following accessory uses are permitted: a) an accessory child care centre in accordance with the provisions of Section 5.1. b) an accessory boarding use in accordance with the provisions of Section 5.4. c) an accessory registered secondary suite in accordance with the provisions of Section 5.5. d) an accessory dwelling unit in accordance with the provisions of Section 5.6. e) an accessory bed & breakfast use in accordance with the provisions of Section 5.7. f) a short term rental in accordance with the provisions of Section 5.8. g) a care facility in accordance with the provisions of Section 5.1. 2) In conjunction with a house-plex use only the following accessory uses is permitted: a) an accessory dwelling unit in accordance with the provisions of Section 5.6. 3) an accessory home occupation in accordance with the provisions of Section 5.3 6.3.3 Lot Size: 1) The minimum lot width, lot depth and lot area in the RS-3 (Small lot, Hillside) SSMUH Residential Zone are as follows: Lot width 9.0m (29.531ft) Lot depth 27.4m (89.9ft) Lot area 280.00m² (918.64ft²) 6.3.4 Lot Coverage: 1) The maximum lot coverage is 50%. 6.3.5 Permitted Density: 1) The maximum permitted number of dwelling units on a parcel of land based on minimum lot area and location of a prescribed bus stop: Zoning Bylaw No. 2506 Page 47 a) Outside 400m radius from a prescribed bus stop i) Lots upto 280m2 Upto 3 dwelling units ii) Lots greater than 280m2 and less than 4,050m2 Upto 4 dwelling units b) Within 400m radius from a prescribed bus stop i) Lots greater than 280m2 and less than 281m2 Upto 4 dwelling units ii) Lots at least 281m2 or greater Upto 6 dwelling units 6.3.6 Floor Area: 1) maximum residential gross floor area shall not exceed 1.05 times the lot area for a maximum of 2 dwelling units on a parcel of land. 2) maximum residential gross floor area shall not exceed 1.15 times the lot area for above 2 dwelling units to a maximum of 4 dwelling units on a parcel of land. 3) maximum residential gross floor area shall not exceed 1.25 times the lot area for above 4 dwelling units to a maximum of 6 dwelling units on a parcel of land. 6.3.7 Landscape Requirements: 1) The maximum impermeable surface area on the parcel of land is 80%; 2) The minimum permeable surface area on the parcel of land is 20%, of which 50% at minimum will contain live plant material; 3) 50% of the required front yard will be landscaped with live plant material including a 1.2m (3.94ft) permeable landscape strip containing live plant material on either side of the driveway; and 4) The owner of the property is responsible for the placement and proper maintenance of landscaping. 6.3.8 Building Heights: 1) principal buildings shall not exceed a height of 7.7m (25.26ft), and the height of the southerly elevation of the building shall be determined by an angle of containment of 45 degrees to the vertical commencing 6.0 metres (19.69 feet) above the natural grade at the base of the south wall as illustrated in sub-section 4.9. 2) accessory dwelling unit shall not exceed a height of 7.0m (22.97ft) for a building with a minimum roof slope of 6:12, and shall not exceed a height of 6.0m (19.69ft) for a building with any lesser roof slope. 3) ancillary buildings and structures shall not exceed a height of 4.0m (13.12ft) 6.3.9 Minimum Setback Requirements: 1) principal buildings and ancillary buildings and structures in the RS-3 (Small lot, Hillside) SSMUH Residential Zone shall be sited in accordance with the following minimum setback requirements: Zoning Bylaw No. 2506 Page 48 Setback Principal Building Ancillary Buildings and Structures Accessory Dwelling Unit Front lot line i.e. see 2) below 3.0m (9.84ft) Not Permitted Rear lot line i.e. see 2) below 3.0m (9.84ft) 1.5m (4.92ft) Interior side lot line 1.2m (3.94ft) 1.2m (3.94ft) Interior side lot line (abutting a lane) 1.8m (5.91ft) 1.8m (5.91ft) Exterior side lot line (rear lot line abutting a lane or rear lot line of adjacent lot) i.e. for a distance of 7.5m (24.61ft) as per 3) below 1.8m (5.91ft) & 1.5m (4.92ft) 1.8m (5.91ft) & 1.5m (4.92ft) 2) Notwithstanding the above, the front and rear yard setbacks shall in combination be not less than 9.0m (29.52ft). 3) Notwithstanding the above, the exterior side yard setback requirement for principal buildings and for accessory dwelling units or ancillary buildings and structures shall be 1.8m (5.91ft) for a distance of 7.5m (24.61ft) from the front lot line and 1.5m (4.92ft) from that point to the rear lot line of the lot. 6.3.10 Ancillary Buildings and Structures or Accessory Dwelling Units: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.3.8 and 6.3.9 above, the following also applies: 1) there shall be not more than one ancillary building per lot. 2) ancillary buildings and structures shall not be located in any required front yard or exterior side yard area. 3) ancillary buildings or structures shall not be sited less than 3.0m (9.84ft) from a principal building on the same lot. 4) accessory dwelling units shall not be located in any required front yard or exterior side yard area. 5) accessory dwelling units shall be located not less than 3.0m (9.84ft) from a principal building. 6.3.11 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. Zoning Bylaw No. 2506 Page 49 6.4 RI-1 (Infill 1) SSMUH Residential Zone - South of Hospital Lands The intent of this zone is to accommodate infill redevelopment in the South of Hospital Lands area for up to four dwelling units on a single parcel of land that is located outside of a 400m radius from a prescribed bus stop, or six units within 400m radius from a prescribed bus stop on a single parcel of land, located within the urban containment boundary, in a variety of building forms. 6.4.1 Permitted Principal Uses: 1) Only one (1) principal use is permitted on a parcel of land: a) a one-unit residential use or b) house-plex 6.4.2 Permitted Accessory Uses: 1) In conjunction with a one-unit residential use not more than one (1) of the following accessory uses are permitted: a) an accessory child care centre in accordance with the provisions of Section 5.1. b) an accessory boarding use in accordance with the provisions of Section 5.4. c) an accessory registered secondary suite in accordance with the provisions of Section 5.5. d) an accessory dwelling unit in accordance with the provisions of Section 5.6. e) an accessory bed & breakfast use in accordance with the provisions of Section 5.7. f) a short term rental in accordance with the provisions of Section 5.8. g) a care facility in accordance with the provisions of Section 5.1. 2) In conjunction with a house-plex use only the following accessory uses is permitted: a) an accessory dwelling unit in accordance with the provisions of Section 5.6. 3) an accessory home occupation in accordance with the provisions of Section 5.3. 6.4.3 Lot Size: 1) The minimum lot width, lot depth and lot area for fee simple and bare land strata lots in the RI-1 (Infill 1) SSMUH Residential Zone - South of Hospital Lands are as follows: Lot width 9.1m (29.86ft) Lot depth with shared access 35.0m (114.83ft) Lot area 333.0m² (3,584.38ft²) 6.4.4 Lot Coverage: 1) The maximum lot coverage is 50%. 6.4.5 Permitted Density: 1) The maximum permitted number of dwelling units on a parcel of land based on minimum lot area and location of a prescribed bus stop: Zoning Bylaw No. 2506 Page 50 a) Outside 400m radius from a prescribed bus stop i) Lots upto 280m2 Upto 3 dwelling units ii) Lots greater than 280m2 and less than 4,050m2 Upto 4 dwelling units b) Within 400m radius from a prescribed bus stop i) Lots greater than 280m2 and less than 281m2 Upto 4 dwelling units ii) Lots at least 281m2 or greater Upto 6 dwelling units 6.4.6 Floor Area: 1) maximum residential gross floor area shall not exceed 0.75 times the lot area for a maximum of 2 dwelling units on a parcel of land. 2) maximum residential gross floor area shall not exceed 0.85 times the lot area for parcels of land that contain more than 2 dwelling units. 6.4.7 Landscape Requirements: 1) The maximum impermeable surface area on the parcel of land is 80%; 2) The minimum permeable surface area on the parcel of land is 20%, of which 50% at minimum will contain live plant material; 3) 50% of the required front yard will be landscaped with live plant material including a 1.2m (3.94ft) permeable landscape strip containing live plant material on either side of the driveway; and 4) The owner of the property is responsible for the placement and proper maintenance of landscaping. 6.4.8 Building Heights: 1) principal buildings shall not exceed a height of 9.0m (29.53ft) for a building with a roof slope of 1:1 and shall not exceed a height of 8.0m (26.25ft) for a building with any lesser roof slope. 2) accessory dwelling unit shall not exceed a height of 7.0m (22.97ft) for a building with a minimum roof slope of 6:12, and shall not exceed a height of 6.0m (19.69ft) for a building with any lesser roof slope. 3) ancillary buildings and structures shall not exceed a height of 3.0m (9.84ft). 4) dormers and any part of the building that projects out of either roof angle shall be limited to 0.4 times the length of the base wall of the same face of the building facing the same lot line, provided that the roof for any such projection has a minimum slope of 4:12. 6.4.9 Minimum Setback Requirements: 1) principal buildings and ancillary buildings and structures in the RI-1 (Infill 1) SSMUH Residential Zone - South of Hospital Lands shall be sited in accordance with the following minimum setback requirements: Zoning Bylaw No. 2506 Page 51 Setback Principal Building Ancillary Buildings and Structures Accessory Dwelling Unit Front lot line i.e. see 2) & 3) below 3.0m (9.84ft) Not Permitted Rear lot line i.e. see 2) & 3) below 3.0m (9.84ft) 1.5m (4.92ft) Interior side lot line 1.2m (3.94ft) 1.2m (3.94ft) Interior side (abutting a lane) 2.4m (7.87ft) 2.4m (7.87ft) Exterior side lot line (rear lot line abutting a lane or rear lot line of adjacent lot) i.e. for a distance of 6.0m (19.69ft) as per 4) below 2.8.m (9.19ft) & 1.5m (4.92ft) 2.8m (9.19ft) & 1.5m (4.92ft) 2) balconies or decks located on the rear elevation of a principal building are not permitted above the first story. 3) notwithstanding the above, the front and rear yard setbacks shall in combination be not less than 9.0m (29.52ft). 4) Notwithstanding the above, the exterior side yard setback requirement for principal buildings and for ancillary buildings and structures shall be 2.8m (9.19ft) for a distance of 6.0m (19.69ft) from the front lot line and 1.5m (4.93ft) from that point to the rear lot line of the lot. 6.4.10 Ancillary Buildings and Structures or Accessory Dwelling Units: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.4.8 and 6.4.9 above, the following also applies: 1) there shall be not more than one ancillary building per lot. 2) ancillary buildings or structures shall not be located in any required front yard or exterior side yard area. 3) ancillary buildings or structures shall be located not less than 1.5m (4.92ft) from a principal building. 4) accessory dwelling units shall not be located in any required front yard or exterior side yard area. 6.4.11 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. 6.4.12 Notwithstanding the provisions of Section 4.14, driveways shall not exceed a width of 4.0m (13.12ft). Further, the width of an opening to a garage for vehicular access and contained within the principal building shall not exceed 3.5m (11.48ft). Zoning Bylaw No. 2506 Page 52 6.5 RI-2 (Infill 2) SSMUH Residential Zone The intent of this zone is to accommodate infill redevelopment in the East Side Large Lot Infill Redevelopment Area for up to four dwelling units on a single parcel of land that is located outside of a 400m radius from a prescribed bus stop, or six units within 400m radius from a prescribed bus stop, on a single parcel of land within the urban containment boundary, in a variety of building forms. 6.5.1 Permitted Principal Uses: 1) Only one (1) principal use is permitted on a parcel of land: a) a one-unit residential use or b) house-plex 6.5.2 Permitted Accessory Uses: 1) In conjunction with a one-unit residential use not more than one (1) of the following accessory uses are permitted: a) an accessory child care centre in accordance with the provisions of Section 5.1. b) an accessory boarding use in accordance with the provisions of Section 5.4. c) an accessory registered secondary suite in accordance with the provisions of Section 5.5. d) an accessory dwelling unit in accordance with the provisions of Section 5.6. e) an accessory bed & breakfast use in accordance with the provisions of Section 5.7. f) a short term rental in accordance with the provisions of Section 5.8. g) a care facility in accordance with the provisions of Section 5.1. 2) In conjunction with a house-plex use only the following accessory uses is permitted: a) an accessory dwelling unit in accordance with the provisions of Section 5.6. 3) an accessory home occupation in accordance with the provisions of Section 5.3. 6.5.3 Lot Size: 1) The minimum lot width, lot depth, and lot area for fee-simple and bare land strata lots in the RI-2 (Infill 2) SSMUH Residential Zone are as follows: Dimension Type Narrow Lot Housing With Rear Lane Access Narrow Lot Housing with Shared Access Lot width for interior lots 9.15m (30.0ft) 10.0m (32.8ft) Lot width for corner lots 10.0m (32.8ft) 10.0m (32.8ft) Lot depth 27.4m (90.0ft) 33.5m (110.0ft Lot area 256.0m² (2,755.56ft²) 335.0m² (3,606.0ft²) 6.5.4 Lot Coverage: 1) The maximum lot coverage is 50%. Zoning Bylaw No. 2506 Page 53 6.5.5 Permitted Density: 1) The maximum permitted number of dwelling units on a parcel of land based on minimum lot area and location of a prescribed bus stop: a) Outside 400m radius from a prescribed bus stop i) Lots upto 280m2 Upto 3 dwelling units ii) Lots greater than 280m2 and less than 4,050m2 Upto 4 dwelling units b) Within 400m radius from a prescribed bus stop i) Lots greater than 280m2 and less than 281m2 Upto 4 dwelling units ii) Lots at least 281m2 or greater Upto 6 dwelling units 6.5.6 Floor Area: 1) maximum residential gross floor area shall not exceed 1.0 times the lot area for a maximum of 2 dwelling units on a parcel of land. 2) maximum residential gross floor area shall not exceed 1.1 times the lot area for parcels of land that contain more than 2 dwelling units. 6.5.7 Landscape Requirements: 1) The maximum impermeable surface area on the parcel of land is 80%; 2) The minimum permeable surface area on the parcel of land is 20%, of which 50% at minimum will contain live plant material; 3) 50% of the required front yard will be landscaped with live plant material including a 1.2m (3.94ft) permeable landscape strip containing live plant material on either side of the driveway; and 4) The owner of the property is responsible for the placement and proper maintenance of landscaping. 6.5.8 Building Heights: 1) principal buildings shall not exceed a height of 7.7m (25.26 ft.). 2) accessory dwelling unit shall not exceed a height of 7.0m (22.97ft) for a building with a minimum roof slope of 6:12, and shall not exceed a height of 6.0m (19.69ft) for a building with any lesser roof slope. 3) ancillary buildings and structures shall not exceed a height of 3.0m (9.84ft). 6.5.9 Minimum Setback Requirements: 1) principal buildings and ancillary buildings and structures in the RI-2 (Infill 2) SSMUH Residential Zone shall be sited in accordance with the following minimum setback requirements: Zoning Bylaw No. 2506 Page 54 Setback Principal Building Ancillary Buildings and Structures Accessory Dwelling Units Front lot line 3.0m (9.8ft) Not permitted Rear lot line with shared access driveway 6.0m (19.7ft) 1.2m (3.94ft) Rear lot line abutting a lane 6.0m (19.7ft) 3.0m (9.8ft) Interior side lot line with rear yard access from a lane 1.2m (3.94ft) 0.0m (0.0ft) on one side; 3.0m (9.8ft) on the other when needed to accommodate the 3rd parking space, or 1.2m (3.94ft) to accommodate a 2nd level accessory dwelling unit over a carport. Interior side lot line with shared access driveway 2.07m (6.8ft) on the driveway access side; 1.2m (3.94ft) on the other side 0.0m (0.0ft) on one side; 1.5m (4.92ft) on the other when needed to accommodate the 3rd parking space, or 1.2m (3.94ft) for a two storey accessory dwelling unit. Exterior side lot line 2.07m (6.8ft) 2.07m (6.8ft) 6.5.10 Ancillary Buildings and Structures or Accessory Dwelling Units: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.5.8 and 6.5.9 above, the following also applies: 1) there shall be not more than one ancillary building per lot. 2) ancillary buildings and structures shall not be located in any required front yard or exterior side yard area. 3) ancillary buildings and structures shall be located not less than 3.0m (9.84ft) from a principal building. 4) accessory dwelling units shall not be located in any required front yard or exterior side yard area. 5) accessory dwelling units shall be located not less than 3.0m (9.84ft) from a principal building. 6.5.11 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. Zoning Bylaw No. 2506 Page 55 6.6 RE-1 SSMUH Estate Residential 1 Zone The intent of this zone is to provide for the development of up to two dwelling units on a single parcel of land within the urban containment boundary, in a variety of building forms. 6.6.1 Permitted Principal Uses: 1) Only one (1) principal use is permitted on a parcel of land: a) a one-unit residential use 6.6.2 Permitted Accessory Uses: 1) In conjunction with a one-unit residential use with not more than one (1) of the following accessory uses: a) an accessory child care centre in accordance with the provisions of Section 5.1. b) an accessory boarding use in accordance with the provisions of Section 5.4. c) an accessory registered secondary suite in accordance with the provisions of Section 5.5. d) an accessory dwelling unit in accordance with the provisions of Section 5.6. e) an accessory bed & breakfast use in accordance with the provisions of Section 5.7. f) a short term rental in accordance with the provisions of Section 5.8. g) a care facility in accordance with the provisions of Section 5.1. 2) an accessory home occupation in conjunction with a one-unit residential use and in accordance with the provisions of Section 5.3; 6.6.3 Lot Size: 1) The minimum lot width, lot depth and lot area in the RE-1 SSMUH Estate Residential 1 Zone are as follows: Lot width 30.0m (98.4ft) Lot depth 100.0m (328.08ft) Lot area 0.5ha (1.235ac) 6.6.4 Lot Coverage: 1) The maximum lot coverage is 20%. 6.6.5 Floor Area: 1) maximum residential gross floor area shall not exceed 0.3 times the lot area. 6.6.6 Landscape Requirements: 1) The maximum impermeable surface area on the parcel of land is 60%; 2) The minimum permeable surface area on the parcel of land is 40%, of which 50% at minimum will contain live plant material; 3) 50% of the required front yard will be landscaped with live plant material including a 1.2m (3.94ft) permeable landscape strip containing live plant material on either side of the driveway; and Zoning Bylaw No. 2506 Page 56 4) The owner of the property is responsible for the placement and proper maintenance of landscaping. 6.6.7 Building Heights: 1) principal buildings shall not exceed a height of 7.7m (25.26ft). 2) accessory dwelling unit shall not exceed a height of 7.0m (22.97ft) for a building with a minimum roof slope of 6:12, and shall not exceed a height of 6.0m (19.69ft) for a building with any lesser roof slope. 3) ancillary buildings and structures shall not exceed a height of 5.0m (16.40ft). 6.6.8 Minimum Setback Requirements: 1) principal buildings and ancillary buildings and structures in the RE-1 SSMUH Estate Residential 1 Zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Building Ancillary Buildings and Structures Accessory Dwelling Unit Front lot line 7.5m (24.61ft) Not Permitted Rear lot line 7.5m (24.61ft) 1.5m (4.92ft) Interior side lot line 1.5m (4.92ft) 1.5m (4.92ft) Exterior side lot line (abutting a lane, or where the rear lot line abuts the rear lot line of an adjacent residential lot, or abutting an interior or rear lot line for a commercial use) 3.8m (12.47ft) 3.8m (12.47ft) Exterior side lot line (where the rear lot line abuts the interior side lot line of an adjacent residential lot) 7.5m (24.61ft) 7.5m (24.61ft) 6.6.9 Ancillary Buildings and Structures or Accessory Dwelling Units: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.6.7 and 6.6.8 above, the following also applies: 1) there shall be not more than one ancillary building per lot. 2) ancillary buildings and structures shall not be located in any required front yard or exterior side yard area. 6) accessory dwelling units shall not be located in any required front yard or exterior side yard area. 7) accessory dwelling units hall be located not less than 3.0m (9.84ft) from a principal building. 6.6.10 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. Zoning Bylaw No. 2506 Page 57 6.7 RE-2 SSMUH Estate Residential 2 Zone The intent of this zone is to provide for the development of up to four dwelling units on a single parcel of land with a lot area equal to or less than 4,050m2 that is located outside of a 400m radius from a prescribed bus stop, or six units within 400m radius from a prescribed bus stop on a single parcel of land with a lot area equal to or less than 4,050m2, within the urban containment boundary, in a variety of building forms. 6.7.1 Permitted Principal Uses: 1) Only one (1) Principal use is permitted on a parcel of land: a) a one-unit residential use; or, b) house-plex- only permitted on a parcel of land with a lot area equal to or less than 4,050m2. 6.7.2 Permitted Accessory Uses: 1) In conjunction with a one-unit residential use with not more than one (1) of the following accessory uses: a) an accessory child care centre in accordance with the provisions of Section 5.1. b) an accessory boarding use in accordance with the provisions of Section 5.4. c) an accessory registered secondary suite in accordance with the provisions of Section 5.5. d) an accessory dwelling unit in accordance with the provisions of Section 5.6. e) an accessory bed & breakfast use in accordance with the provisions of Section 5.7. f) a short term rental in accordance with the provisions of Section 5.8. g) a care facility in accordance with the provisions of Section 5.1. 2) In conjunction with a house-plex use only the following accessory uses is permitted: a) an accessory dwelling unit in accordance with the provisions of Section 5.6. 3) an accessory home occupation in conjunction with a one-unit residential use in accordance with the provisions of Section 5.3. 6.7.3 Lot Size: 1) The minimum lot width, lot depth and lot area in the RE-2 SSMUH Estate Residential 2 Zone are as follows: Lot width 23.0m (75.46ft) Lot depth 60.0m (196.8ft) Lot area 2,000m2 (21,527.9ft2) 6.7.4 Lot Coverage: 1) maximum lot coverage is 25%. 6.7.5 Permitted Density: 1) The maximum permitted number of dwelling units on a parcel of land based on minimum lot area and location of a prescribed bus stop: Zoning Bylaw No. 2506 Page 58 a) Outside 400m radius from a prescribed bus stop i) Lots greater than 280m2 and less than 4,050m2 Upto 4 dwelling units b) Within 400m radius from a prescribed bus stop i) Lots at least 281m2 or greater Upto 6 dwelling units 6.7.6 Floor Area: 1) maximum residential gross floor area shall not exceed 0.35 times the lot area for a maximum of 2 dwelling units on a parcel of land. 2) maximum residential gross floor area shall not exceed 0.4 times the lot area for parcels of land that contain more than 2 dwelling units. 6.7.7 Landscape Requirements: 1) The maximum impermeable surface area on the parcel of land is 60%; 2) The minimum permeable surface area on the parcel of land is 40%, of which 50% at minimum will contain live plant material; 3) 50% of the required front yard will be landscaped with live plant material, including a 1.2m (3.94ft) permeable landscape strip containing live plant material on either side of the driveway; and 4) The owner of the property is responsible for the placement and proper maintenance of landscaping. 6.7.8 Building Heights: 1) principal buildings shall not exceed a height of 7.7m (25.26ft). 2) ancillary buildings and structures, or accessory dwelling unit shall not exceed a height of 5.0m (16.40ft). 6.7.9 Minimum Setback Requirements: 1) principal buildings and ancillary buildings and structures in the RE-2 SSMUH Estate Residential 2 zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Building Ancillary Buildings and Structures Accessory Dwelling Unit Front lot line 7.5m (24.61ft) Not Permitted Rear lot line 7.5m (24.61ft) 1.5m (4.92ft) Interior side lot line 1.5m (4.92ft) 1.5m (4.92ft) Exterior side lot line (abutting a lane, or where the rear lot line abuts the rear lot line of an 3.8m (12.47ft) 3.8m (12.47ft) Zoning Bylaw No. 2506 Page 59 adjacent residential lot, or abutting an interior or rear lot line for a commercial use) Exterior side lot line (where the rear lot line abuts the interior side lot line of an adjacent residential lot) 7.5m (24.61ft) 7.5m (24.61ft) 6.7.10 Ancillary Buildings and Structures or Accessory Dwelling Units: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.7.8 and 6.7.9 above, the following also applies: 1) there shall be not more than one ancillary building per lot. 2) ancillary buildings and structures shall not be located in any required front yard or exterior side yard area. 3) accessory dwelling units shall not be located in any required front yard or exterior side yard area. 4) accessory dwelling units shall be located not less than 3.0m (9.84ft) from a principal building. 6.7.11 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. Zoning Bylaw No. 2506 Page 60 6.8 RM-1 Low Density Multi-Unit Residential Zone The intent of this zone is to accommodate multi-unit residential uses in the form of townhouse or apartment complexes at low densities not exceeding 24 units per 0.4 hectare (1.0 acre). 6.8.1 Permitted Uses: 1) a multi-unit residential use in conjunction with not more than one (1) of the following accessory uses, per dwelling unit: a) an accessory home occupation in accordance with the provisions of Section 5.3. b) an accessory boarding use in accordance with the provisions of Section 5.4. 2) a multi-unit residential use is permitted in one (1) or more principal buildings. 6.8.2 Lot Size: 1) Minimum lot width, lot depth and lot area in the RM-1 zone are as follows: Lot width 18.0m (59.04ft) Lot depth 30.5m (100.4ft) Lot area 742.0m² (7,986.82ft²) 6.8.3 Lot Coverage: 1) Maximum lot coverage per fee-simple lot is 45%. 6.8.4 Density: 1) Maximum number of dwelling units permitted shall be based on a lot area of not less than 167 m2 (1,797.57 ft2) per dwelling unit for a maximum density of 24 units per 0.4 ha (1.0 acres). 6.8.5 Building Heights: 1) Principal buildings shall not exceed a height of 7.7m (25.26ft). 2) Ancillary buildings and structures shall not exceed a height of 4.0m (13.12ft). 6.8.6 Minimum Setback Requirements: 1) Principal buildings and ancillary buildings and structures in the RM-1 zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Building Ancillary Buildings and Structures Front lot line 7.5m (24.61ft) Not permitted Rear lot line 7.5m (24.61ft) 1.5m (4.92ft) Rear lot line (abutting a lane) 7.5m (24.61ft) 2.4m (7.87ft) Interior side lot line 2.4m (7.87ft) 2.4m (7.87ft) Interior side lot line (abutting a lane) 2.4m (7.87ft) 2.4m (12.47ft) Exterior side lot line (rear lot line abutting a lane or rear lot line of adjacent lot) 3.8m (12.47ft) 3.8m (12.47ft) Exterior side lot line (rear lot line abutting interior side lot line of adjacent lot) 7.5m (24.61ft) 7.5m (24.61ft) Zoning Bylaw No. 2506 Page 61 2) Notwithstanding the above, where the rear lot line of a lot abuts the interior side lot line of an adjacent lot that is zoned for commercial use, the minimum required exterior side yard setback may be reduced to 3.8m (12.47ft). 6.8.7 Ancillary Buildings Structures: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.8.5 and 6.8.6 above, the following also applies: 1) there shall be not more than one ancillary building per fee-simple lot. 2) ancillary buildings and structures shall not be located in any required front yard or exterior side yard area. 3) ancillary buildings and structures shall not be located closer than 3.0m (9.85ft) to a principal building. 6.8.8 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. 6.8.9 Accessory off-street loading spaces shall be provided in accordance with the provisions of sub-sections 4.15.2 and 4.15.3. Zoning Bylaw No. 2506 Page 62 6.9 RM-2 Medium Density Multi-Unit Residential Zone The intent of this zone is to accommodate multi-unit residential uses in the form of townhouse or apartment complexes at medium densities not exceeding 50 units per 0.4 hectare (1.0 acre). 6.9.1 Permitted Uses: 1) a multi-unit residential use in conjunction with not more than one (1) of the following accessory uses, per dwelling unit: a) an accessory home occupation in accordance with the provisions of Section 5.3. b) an accessory boarding use in accordance with the provisions of Section 5.4. 2) a multi-unit residential use is permitted in one (1) or more principal buildings. 6.9.2 Lot Size: 1) Minimum lot width, lot depth and lot area in the RM-2 zone are as follows: Lot width 18.0m (59.04ft) Lot depth 30.5m (100.4ft) Lot area 742.0m² (7,986.82ft²) 6.9.3 Lot Coverage: 1) Maximum lot coverage per fee-simple lot is 45%. 6.9.4 Density: 1) Maximum number of dwelling units permitted shall be based on a lot area of not less than 80.0m2 (861.14 ft2) per dwelling unit for a maximum density of 50 units per 0.4ha (1.0ac), and a maximum residential floor area of 1.1 times the lot area. 2) Maximum residential floor area may be increased: i) by not more than 37.0m2 (398.26ft2) total where common recreation facilities are provided within a principal building for the exclusive use of the occupants; ii) by not more than 5.6m2 (60.28ft2) per dwelling unit where storage and laundry facilities are provided within the individual dwelling units. 6.9.5 Building Heights: 1) Principal buildings shall not exceed a height of 10.7m (35.1ft). 2) Ancillary buildings and structures shall not exceed a height of 4.0m (13.12ft). Zoning Bylaw No. 2506 Page 63 6.9.6 Minimum Setback Requirements: 1) Principal buildings and ancillary buildings and structures in the RM-2 zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Building Ancillary Buildings and Structures Front lot line 6.0m (19.68ft) Not permitted Rear lot line (not abutting a lane) 6.0m (19.68ft) 1.5m (4.92ft) Rear lot line (abutting a lane) 6.0m (19.68ft) 2.4m (7.87ft) Interior side lot line (not abutting a lane) see 3) and 4) below 1.5m (4.92ft) Interior side lot line (abutting a lane) see 3) and 4) below 2.4m (12.47ft) Exterior side lot line (rear lot line abutting a lane or rear lot line of adjacent lot) 3.8m (12.47ft) 3.8m (12.47ft) Exterior side lot line (rear lot line abutting interior side lot line of adjacent lot) 6.0m (19.68ft) 6.0m (19.68ft) 2) Notwithstanding the above, where the rear lot line of a lot abuts the interior side lot line of an adjacent lot that is zoned for commercial use, the minimum required exterior side yard setback may be reduced to 3.8m (12.47ft). 3) The minimum interior side lot line shall be 3.0m (9.84ft) where the wall or walls of the principal building facing that interior side lot line either has no windows, or windows to non-habitable rooms only. 4) The minimum interior side lot line shall be 5.0m (16.4ft) where the wall or walls of the principal building facing that interior side lot line has a window or windows to a habitable room, or to a balcony, provided that no part of any balcony shall be sited less than 3.0m (9.84ft) from an interior side lot line. 6.9.7 Ancillary Buildings and Structures: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.9.5 and 6.9.6 above, the following also applies: 1) there shall be not more than one ancillary building per fee-simple lot. 2) ancillary buildings and structures shall not be located in any required front yard or exterior side yard area. 3) ancillary buildings and structures shall not be located closer than 3.0m (9.85ft) to a principal building. 6.9.8 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. 6.9.9 Accessory off-street loading spaces shall be provided in accordance with the provisions of sub-sections 4.15.2 and 4.15.3. Zoning Bylaw No. 2506 Page 64 6.10 RM-3 High Density Multi-Unit Residential Zone The intent of this zone is to accommodate multi-unit residential uses in the form of apartment complexes at high densities not exceeding 90 units per 0.4 hectare (1.0 acre). 6.10.1 Permitted Uses: 1) a multi-unit residential use in conjunction with not more than one (1) of the following accessory uses, per dwelling unit: a) an accessory home occupation in accordance with the provisions of Section 5.3. b) an accessory boarding use in accordance with the provisions of Section 5.4. 2) a multi-unit residential use is permitted in one (1) or more principal buildings. 6.10.2 Lot Size: 1) Minimum lot width, lot depth and lot area in the RM-3 zone are as follows: Lot width 18.0m (59.04ft) Lot depth 30.5m (100.4ft) Lot area 742.0m² (7,986.82ft²) 6.10.3 Lot Coverage: 1) Maximum lot coverage per fee-simple lot is 45%. 6.10.4 Density: 1) Maximum number of dwelling units permitted shall be based on a lot area of not less than 44.4m2 (478.4ft2) per dwelling unit for a maximum density of 90 units per 0.4ha (1.0ac), and a maximum residential floor area of 2.0 times the lot area. 2) Maximum residential floor area may be increased: i) by not more than 37.0m2 (398.26ft2) total where common recreation facilities are provided within a principal building for the exclusive use of the occupants; ii) by not more than 5.6m2 (60.28ft2) per dwelling unit where storage and laundry facilities are provided within the individual dwelling units. 6.10.5 Building Heights: 1) Principal buildings shall not exceed a height of 23.0m (75.46ft). 2) Ancillary buildings and structures shall not exceed a height of 4.0m (13.12ft). Zoning Bylaw No. 2506 Page 65 6.10.6 Minimum Setback Requirements: 1) Principal buildings and ancillary buildings and structures in the RM-3 zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Building Ancillary Buildings and Structures Front lot line 6.0m (19.68ft) Not permitted Rear lot line (not abutting a lane) 6.0m (19.68ft) 1.5m (4.92ft) Rear lot line (abutting a lane) 6.0m (19.68ft) 2.4m (7.87ft) Interior side lot line (not abutting a lane) 6.0m (19.68ft) 1.5m (4.92ft) Interior side lot line (abutting a lane) 6.0m (19.68ft) 2.4m (12.47ft) Exterior side lot line 6.0m (19.68ft) 6.0m (19.68ft) 2) Notwithstanding the above, where the interior lot line abuts another lot zoned RM-3 the principal building shall be located no closer than 12.2m (40.0ft) from the interior lot line to ensure a minimum separation distance of 24.4m (80.0ft) between principal buildings for principal buildings that exceed 10.7m (35.1ft) in building height. 6.10.7 Ancillary Buildings and Structures: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.10.5 and 6.10.6 above, the following also applies: 1) there shall be not more than one ancillary building per fee-simple lot. 2) ancillary buildings and structures shall not be located in any required front yard or exterior side yard area. 3) ancillary buildings and structures shall not be located closer than 3.0m (9.85ft) to a principal building. 6.10.8 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. 6.10.9 Accessory off-street loading spaces shall be provided in accordance with the provisions of sub-section 4.15.2. Zoning Bylaw No. 2506 Page 66 6.11 RM-4 Marine Drive Medium Density Multi-Unit Residential Zone The intent of this zone is to accommodate multi-unit residential uses in the form of apartment complexes at medium densities not exceeding 50 units per 0.4 hectare (1.0 acre) along limited areas of Marine Drive. 6.11.1 Permitted Uses: 1) a multi-unit residential use in conjunction with not more than one (1) of the following accessory uses, per dwelling unit: a) an accessory home occupation in accordance with the provisions of Section 5.3. b) an accessory boarding use in accordance with the provisions of Section 5.4. 2) a multi-unit residential use is permitted in one (1) or more principal buildings. 6.11.2 Lot Size: 1) Minimum lot width, lot depth and lot area in the RM-4 zone are as follows: Lot width 13.1m (43.0ft) Lot depth 18.79m (61.6ft) Lot area 295.0m² (3,175.35ft²) 6.11.3 Lot Coverage: 1) Maximum lot coverage per fee-simple lot is 60%. 6.11.4 Density: 1) Maximum number of dwelling units permitted shall be based on a lot area of not less than 80 m2 (861.14 ft2) per dwelling unit for a maximum density of 50 units per 0.4 ha (1.0 acres), and a maximum residential floor area of 1.1 times the lot area. 2) Maximum residential floor area may be increased: i) by not more than 37.0m2 (398.26ft2) total where common recreation facilities are provided within a principal building for the exclusive use of the occupants; ii) by not more than 5.6m2 (60.28ft2) per dwelling unit where storage and laundry facilities are provided within the individual dwelling units. 6.11.5 Building Heights: 1) Principal buildings shall not exceed a height of 7.7m (25.26ft) and the height of the southerly elevation of the building shall be determined by an angle of containment as illustrated in sub-section 4.9. 2) Structures shall not exceed a height of 4.0m. Zoning Bylaw No. 2506 Page 67 6.11.6 Minimum Setback Requirements: 1) Principal buildings and structures in the RM-4 zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Building Structures Front lot line 3.0m (9.84ft) Not permitted Rear lot line (not abutting a lane) 3.0m (9.84ft) 1.5m (4.92ft) Rear lot line (abutting a lane) 1.8m (5.91ft) 2.4m (7.87ft) Interior side lot line 1.2m (3.94ft) 1.5m (4.92ft) Exterior side lot line ... see 2) below 3.0m (9.84ft) 3.0m (9.84ft) 2) The setback requirement shall be 3.0m (9.84ft) from an exterior side lot line for a distance of 7.5m (24.61ft) from the front lot line and 1.5m (4.92ft) from that point to the rear lot line. 6.11.7 Ancillary Buildings and Structures: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- section 6.11.6 above, the following also applies: 1) ancillary buildings shall not be permitted. 2) structures shall not be located in any required front yard or exterior side yard area. 3) structures shall not be sited less than 3.0m from a principal building on the same lot. 6.11.8 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. 6.11.9 Accessory off-street loading spaces shall be provided in accordance with the provisions of sub-section 4.15.2. ‘‹‰›Žƒ™‘ǤʹͷͲ͸ ƒ‰‡͸ͺ 6.12 CR-1 Town Centre Area Commercial / Residential Zone The intent of this zone is to accommodate a mix of uses and activities, including residential and commercial development along with cultural and civic facilities, to support the ability of residents to walk to meet their daily needs. Containing the greatest concentration and variety of employment-generating uses, this zone establishes this area as the City's pedestrian and transit- focused growth area, consistent with the objectives and policies of the Official Community Plan. 6.12.1 Permitted Uses: The following uses are permitted in one (1) or more principal buildings: 1) retail service group 1 uses; 2) subject to section 9 b), licensed establishments, including liquor primary, food primary, liquor store, agent store, u-brew, u-vin, and licensed manufacturer; 3) hotel; 4) civic use; 5) medical or dental clinic; 6) multi-unit residential use; 7) accessory home occupation in conjunction with a multi-unit residential use and in accordance with the provisions of Section 5.3, and that does not involve clients of the home occupation accessing the building in person; 8) use accessory to a retail service group 1 use and limited to a storey above the portion of a building used for the retail service group 1 use. 9) adult entertainment use in accordance with the following provisions: a) the adult entertainment use has a valid business license; b) the adult entertainment use shall not operate in conjunction with a liquor licence in the same establishment; c) the adult entertainment use shall not be located within 500 metres of a school; d) despite Section 6.12.2 Lot Size, the minimum lot width of a lot accommodating an adult entertainment use shall not be less than 45 metres; e) a lot accommodating an adult entertainment use must have a lot line common with North Bluff Road; f) a building accommodating an adult entertainment use must be set back a minimum of 50 metres from Johnston Road and 30 metres from any other public road; and despite Section 4.14.1 Off-Street Parking Requirements, parking for adult entertainment use shall be provided as follows: 1 parking space per every 18.6 m² (200 ft²) of commercial floor area. 10) a cannabis store, as a site-specific permitted use at 1478 Johnston Road (West Half Lot 2 Except: The West 7 Feet; Section 11 Township 1 New Westminster District Plan 8096), subject to the conditions set out in Section 4.1.3.1 of this bylaw. ‘‹‰›Žƒ™‘ǤʹͷͲ͸ ƒ‰‡͸ͻ 6.12.2 Lot Size: 1) Subject to section 9 c), minimum lot width, lot depth and lot area in the CR-1 zone are as follows: Lot width 18.0m (59.0ft) Lot depth 30.48m (100.0ft) Lot area 548.64m2 (5,905.5ft2) 6.12.3 Lot Coverage: 1) Lot coverage per fee simple lot shall not exceed 65%. 2) Despite section 6.12.3(1), on a lot exceeding 3,035m2 (0.75 acres) in area, the area of impermeable materials on the lot shall not exceed 90 percent of the total lot area, and the minimum horizontal (length or width) dimensions for any permeable areas included toward this calculation is 4.0m (13.1 ft). 3) For the purposes of section 6.12.3(2), the following materials are impermeable: asphalt, concrete, brick, and stone. Gravel, river rock less than 5 cm in size, wood chips, bark mulch, and other materials which have fully permeable characteristics when in place installed on grade with no associated layer of impermeable material (such as plastic sheeting) that would impede the movement of water directly into the soil below are excluded from the area of impermeable materials. 6.12.4 Density: The permitted maximum density is varied throughout this zone. 1) The maximum gross floor area shall not exceed 1.75 times the lot area. 2) Despite Section 6.12.4.1, maximum gross floor area may be increased if: a) the owner of the lot i. provides a community amenity described in the City's Community Amenity Reserve Fund Bylaw, 2017, No. 2190, as amended, or ii. elects to pay to the City cash in lieu of the provision of the amenity under that bylaw in the amount of $430 per square metre of gross floor area above 1.75 times the lot area in accordance with an amenity agreement and a section 219 covenant granted to the City by the owner of the subject real property to secure the amenity; b) the lot size meets the minimums in the table below; and Minimum Lot Area Maximum density (gross floor area) 3,035m2 (0.75 acres) 2.3 times the lot area 5,058m2 (1.25 acres) 3.5 times the lot area 8,094m2 (2.0 acres) 4.0 times the lot area* *maximum density may exceed 3.5 times the lot area only for lots north of Russell Avenue c) the uses within a principal building on a lot include: i. a minimum of 30% of the dwelling units secured through a housing agreement registered on title as residential rental tenure for the life of the building; or ‘‹‰›Žƒ™‘ǤʹͷͲ͸ ƒ‰‡͹Ͳ ii. a minimum of 10% of the dwelling units secured through a housing agreement registered on title as residential rental tenure for the life of the building at rents 10% below the average rents for the primary rental market in the City as determined by Canada Mortgage and Housing Corporation; or iii. only non-residential uses. 3) Despite Section 6.12.4.1 and 6.12.4.2, if a development permit allowing density above 1.75 times the lot area for a lot has been issued for the construction of a principal building prior to December 31, 2020, the maximum gross floor area for that lot is the maximum gross floor area that applied at the time of development permit issuance. 6.12.5 Building Heights: The permitted maximum building height is varied throughout this zone. 1) Principal buildings shall not exceed a height of 10.7m (35.1ft). 2) Despite Section 6.12.5.1, maximum heights may be increased to a maximum of 13.7m (44.95ft) and a maximum of four (4) storeys, if the building is set back a minimum 7.0m from the lot line adjacent to Johnston Road, and the exterior wall of the top storey of a building facing Johnston Road is set back a minimum 2.0m from the exterior wall of the storey below it. 3) Despite Section 6.12.5.1, if a lot qualifies for the increased density described in section 6.12.4.2, the maximum permitted number of storeys for a principal building on the lot shall be in accordance with the number of storeys indicated by the following diagram, and in no case shall a principal building exceed a height of 40.0m (131.2ft). 4) Despite Section 6.12.5.1, if a development permit allowing a principal building with a maximum height over 10.7 metres for a lot has been issued for the construction of a principal building prior to December 31, 2020, the maximum height for that lot is the maximum height that applied at the time of development permit issuance. Zoning Bylaw No. 2506 Page 71 For certainty, the ^ symbol on the diagram above identifies where additional height is permitted if an on-site community amenity space (such as a City-owned conference centre, art gallery, or City Hall) is provided in addition to the amenity contribution in section 6.12.4(2)(a), with a minimum floor area of 1,400 square metres (15,069 square feet). The maximum height in storeys on these lots without such community amenity space is ten (10) storeys. The * symbol on the diagram above identifies where a fourth storey is permitted if the building complies with the additional setback requirements in section 6.12.5.2; The maximum height in storeys on these lots without such setbacks is three (3) storeys and 10.7m, per section 6.12.5.1. Zoning Bylaw No. 2506 Page 72 6.12.6 Minimum Setback Requirements: 1) Principal buildings and structures in the CR-1 zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Building Structures Front lot line (abutting Johnston Road) 15.24m (50ft) from the street centreline 0.0m (0.0ft) See s. 6.12.7 Front lot line (not abutting Johnston Road) 3.0m (9.84ft) 0.0m (0.0ft) See s. 6.12.7 Exterior side lot line (abutting Johnston Road) 15.24m (50ft) from the street centreline 0.0m (0.0ft) See s. 6.12.7 Exterior side lot line (not abutting Johnston Road) 3.0m (9.84ft) 0.0m (0.0ft) See s. 6.12.7 Interior side lot line 0.0m (0.0ft) 0.0m (0.0ft) Rear lot line (abutting a street) 3.0m (9.84ft) Not permitted Rear lot line (abutting a lane) 0.0m (0.0ft) Not permitted Rear lot line (abutting another lot) 0.0m (0.0ft) Not permitted 2) Where the lot line abuts another lot zoned CR-1 or CD and permitting a principal building that exceeds a height of 13.7 m (44.95ft), the portion of the principal building above 13.7m (44.95ft) shall be located a minimum of 12.2m (40.0ft) from the lot line to ensure a minimum separation distance of 24.4m (80.0ft) between buildings above 13.7m (44.95ft) in height. 6.12.7 Ancillary Buildings and Structures: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- section 6.12.6 above, the following also applies: 1) ancillary buildings are not permitted. 2) ancillary structures shall not be sited less than 3.0m from a principal building on the same lot. 3) despite sub-sections 6.12.6 and 6.12.7 (2), patios and awnings are permitted in the front and exterior side yard areas in accordance with White Rock License Agreement (Sidewalk Café / Business License) Bylaw requirements. 6.12.8 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. 6.12.9 Accessory off-street loading spaces shall be provided in accordance with the provisions of Section 4.15. 6.12.10 Bicycle parking facilities shall be provided in accordance with the standards of Section 4.12.2 and in the quantities indicated in Section 4.12.3. Zoning Bylaw No. 2506 Page 73 6.12.11 Adaptable Units: In a building containing a multi-unit residential use, a minimum of 50% of the dwelling units shall be adaptable housing units that are constructed to comply with the Adaptable Housing standards prescribed in the British Columbia Building Code. Zoning Bylaw No. 2506 Page 74 6.13 CR-2 Lower Town Centre Area Commercial / Residential Zone The intent of this zone is to accommodate commercial and multi-unit residential uses in the Lower Town Centre area and areas adjacent to the Town Centre. 6.13.1 Permitted Uses: The following uses are permitted in one (1) or more principal buildings: 1) retail service group 1 uses; 2) retail service group 2 uses; 3) licensed establishments, including liquor primary, food primary, agent store, u-brew and u-vin; 4) civic use; 5) medical or dental clinic; 6) multi-unit residential use in conjunction with not more than one of the following accessory uses per dwelling unit: g) accessory home occupation in accordance with the provisions of Section 5.3.; h) accessory boarding use in accordance with the provisions of Section 5.4. 7) a use, a two-unit residential use, or a three-unit residential use accessory to a retail service group 1 use or a retail service group 2 use, and limited to the storey or storeys above the portion of a building used for retail service group 1 or retail service group 2 uses. 6.13.2 Lot Size: 1) Minimum lot width, lot depth and lot area in the CR-2 zone are as follows: Lot width 15.24m (50.0ft) Lot depth 35.0m (115.0ft) Lot area 534.2m² (5,750.5ft²) 6.13.3 Lot Coverage: 1) Maximum lot coverage per fee-simple lot is 65%. 6.13.4 Density: 1) Maximum gross floor area (GFA) of all uses shall be 1.75 times the lot area. 6.13.5 Building Heights: 1) Principal buildings shall not exceed a height of 10.7m (35.1ft). 2) Structures shall not exceed a height of 4.0m. Zoning Bylaw No. 2506 Page 75 6.13.6 Minimum Setback Requirements: 1) Principal buildings and structures in the CR-2 zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Building Structures Front lot line 1.5m (4.92ft) Not permitted * Exterior side lot line 1.5m (4.92ft) 3.0m (9.84ft) Interior side lot line or rear lot line adjacent to a lot zoned only for residential use 1.5m (4.92ft) 3.0m (9.84ft) 6.13.7 Ancillary Buildings and Structures: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.13.5 and 6.13.6 above, the following also applies: 1) ancillary buildings shall not be permitted. 2) structures shall not be sited less than 3.0m from a principal building on the same lot. 3) * notwithstanding sub-sections 6.13.6 and 6.13.7 (2), patios and awnings are permitted in the front and exterior side yard areas in accordance with White Rock License Agreement (Sidewalk Café/Business License) Bylaw requirements. 6.13.8 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. 6.13.9 Accessory off-street loading spaces shall be provided in accordance with the provisions of sub-section 4.15.2 and 4.15.3. Zoning Bylaw No. 2506 Page 76 6.14 CR-3 West Beach Business Area Commercial / Residential Zone The intent of this zone is to accommodate commercial and multi-unit residential uses in the West Beach Business area. 6.14.1 Permitted Uses: The following uses are permitted in one (1) or more principal buildings: 1) retail service group 1 uses; 2) licensed establishments, including liquor primary, food primary, agent store, u-brew and u-vin; 3) hotel; 4) medical or dental clinic; 5) multi-unit residential use in conjunction with not more than one of the following accessory uses per dwelling unit: a) accessory home occupation in accordance with the provisions of Section 5.3.; b) accessory boarding use in accordance with the provisions of Section 5.4. 6) a use, a two-unit residential use, or a three-unit residential use accessory to a retail service group 1 use, and limited to the story or stories above the portion of a building used for retail service group 1 uses. 6.14.2 Lot Size: 1) Minimum lot width, lot depth and lot area in the CR-3 zone are as follows: Lot width 15.24m (50.0ft) Lot depth 35.0m (115.0ft) Lot area 534.2m² (5,750.5ft²) 6.14.3 Lot Coverage: 1) Maximum lot coverage per fee-simple lot is 75%. 6.14.4 Density: 1) Maximum gross floor area (GFA) of all uses shall be 1.75 times the lot area. 6.14.5 Building Heights: 1) Principal buildings shall not exceed a height of 11.3 metres (37.1 feet) measured as the vertical distance from the roof peak to the lessor of either the natural grade adjacent to the mid-point of the building on the lowest side of the property or not more than 0.5m (1.64ft) above the average height at the top of curb for the lowest street frontage adjacent to the property. Notwithstanding, where more than one principal building is proposed and where the natural grade for those other principal buildings is greater than 3.2 metres (10.5 feet) higher than the 1st or lowest principal building, the maximum height of the other principal buildings shall be no more than 3.2 metres (10.5 feet) greater in geodetic elevation than the maximum height of the 1st or lowest principal building, as shown in the illustration below. Zoning Bylaw No. 2506 Page 77 2) Structures shall not exceed a height of 4.0m. 6.14.6 Minimum Setback Requirements: 1) Principal buildings and structures in the CR-3 zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Building Structures Front lot line 1.5m (4.92ft) Not permitted * Exterior side lot line 1.5m (4.92ft) 3.0m (9.84ft) Interior side lot line or rear lot line adjacent to a lot zoned only for residential use 1.5m (4.92ft) 3.0m (9.84ft) 2) Notwithstanding sub-section 1) above, principal buildings shall be set back no more than 2.5m (8.2ft) from Marine Drive, where applicable. 6.14.7 Ancillary Buildings and Structures: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- section 6.14.5 and 6.14.6 above, the following also applies: 1) ancillary buildings shall not be permitted. 2) structures shall not be sited less than 3.0m from a principal building on the same lot. 3) * notwithstanding sub-sections 6.14.6 and 6.14.7 (2), patios and awnings are permitted in the front and exterior side yard areas in accordance with White Rock License Agreement (Sidewalk Café / Business License) Bylaw requirements. 6.14.8 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. 6.14.9 Accessory off-street loading spaces shall be provided in accordance with the provisions of sub-sections 4.15.2 and 4.15.3. Zoning Bylaw No. 2506 Page 78 6.15 CR-4 East Beach Business Area Commercial / Residential Zone The intent of this zone is to accommodate commercial and multi-unit residential uses in the East Beach Business area. 6.15.1 Permitted Uses: The following uses are permitted in one (1) or more principal buildings: 1) retail service group 1 uses; 2) licensed establishments, including liquor primary, food primary, agent store, u-brew and u-vin; 3) hotel; 4) medical or dental clinic; 5) a three-unit residential use or a multi-unit residential use in conjunction with not more than one of the following accessory uses per dwelling unit: a) accessory home occupation in accordance with the provisions of Section 5.3; b) accessory boarding use in accordance with the provisions of Section 5.4. 6) a use or a two-unit residential use accessory to a retail service group 1 use, and limited to the story or stories above the portion of a building used for retail service group 1 uses. 6.15.2 Lot Size: 1) Minimum lot width, lot depth and lot area in the CR-4 zone are as follows: Lot width 9.1m (30.0ft) Lot depth 18.2m (60.0ft) Lot area 167.2m² (1,800.0ft²) 6.15.3 Lot Coverage: 1) Maximum lot coverage per fee-simple lot is 85%. 6.15.4 Density: 1) Maximum gross floor area (GFA) of all uses shall be 1.75 times the lot area. 6.15.5 Building Heights: 1) principal buildings shall not exceed a height of 9.2m (30.18ft) measured as the vertical distance between the highest point of the structure and the average natural grade, however, in no case shall the building be higher than 3.l metres (10.17 feet) above the average natural grade of the rear lot line of the site. The front wall of a building shall not be higher than 4.6 metres (15.09 feet) above the average elevation of the front lot line of the site. The height of the southerly elevation of the building shall be determined by an angle of containment of 45 degrees to the vertical commencing 4.6 metres (15.09 feet) above the natural grade at the base of the wall as illustrated in sub- section 4.9. 2) structures shall not exceed a height of 4.0m. Zoning Bylaw No. 2506 Page 79 6.15.6 Minimum Setback Requirements: 1) Principal buildings and structures in the CR-4 zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Building Structures Front lot line 1.5m (4.92ft) Not permitted * Exterior side lot line 1.5m (4.92ft) 1.5m (4.92ft) Rear lot line 1.83m (6.0ft) 1.83m (6.0ft) 6.15.7 Ancillary Buildings and Structures: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.15.5 and 6.15.6 above, the following also applies: 1) ancillary buildings shall not be permitted. 2) structures shall not be sited less than 3.0m from a principal building on the same lot. 3) * notwithstanding sub-sections 6.15.6 and 6.15.7 (2), patios and awnings are permitted in the front and exterior side yard areas in accordance with White Rock License Agreement (Sidewalk Café / Business License) Bylaw requirements. 6.15.8 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. 6.15.9 Accessory off-street loading spaces shall be provided in accordance with the provisions of sub-sections 4.15.2 and 4.15.3. Zoning Bylaw No. 2506 Page 80 6.16 CR-5 Neighborhood Commercial Zone The intent of this zone is to accommodate neighborhood oriented convenience and limited commercial service type uses. 6.16.1 Permitted Uses: The following uses are permitted in not more than one (1) principal building: 1) a retail service use limited to art gallery, artisan shop, bakery shop, barber, book shop, business school, café or coffee house, dance studio, delicatessen, drug store, dry cleaner, grocery store, hairdresser, health club, launderette, medical or dental clinic, neighborhood convenience store, professional and semi-professional office, stationary store, tailor; 2) a use or a two-unit residential use accessory to a retail service use, and limited to the story or stories above the portion of a building used for retail service use. 6.16.2 Lot Size: 1) Minimum and maximum lot width, lot depth and lot area in the CR-5 zone are as follows: Minimum Maximum Lot width 15.0m (49.21ft) n/a Lot depth 30.5m (100.07ft) n/a Lot area 464.0m² (4,994.45ft²) 1,120.0m2 (12,055.58ft2) 6.16.3 Lot Coverage: 1) maximum lot coverage per fee-simple lot is 45%. 6.16.4 Density: 1) maximum gross floor area of all uses shall be 0.75 times the lot area. 2) maximum gross floor area for accessory buildings shall not exceed 6.0m2 (64.58ft2) 6.16.5 Building Heights: 1) principal buildings shall not exceed a height of 7.7m (25.26ft). 2) ancillary buildings and structures shall not exceed a height of 4.0m2 (13.12ft2). 6.16.6 Minimum Setback Requirements: 1) Principal buildings and ancillary buildings and structures in the CR-5 zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Building Ancillary Buildings and Structures Front lot line 7.5m (24.61ft) Not permitted Rear lot line 7.5m (24.61ft) 1.5m (4.92ft) Interior side lot line 1.5m (4.92ft) 1.5m (4.92ft) Exterior side lot line 3.8m (12.47ft) 7.5m (24.61ft) Zoning Bylaw No. 2506 Page 81 6.16.7 Ancillary Buildings and Structures: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.16.4, 6.16.5 and 6.16.6 above, the following also applies: 1) ancillary buildings and structures shall not be sited less than 3.0m from a principal building on the same lot. 6.16.8 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. 6.16.9 Accessory off-street loading spaces shall be provided in accordance with the provisions of sub-sections 4.15.2 and 4.15.3. Zoning Bylaw No. 2506 Page 82 6.17 CR-6 Gas Bar/Convenience Commercial 1 Zone The intent of this zone is to accommodate automobile fuel sales, a neighborhood oriented convenience store and ancillary car wash. 6.17.1 Permitted Uses: The following uses are permitted in more than one (1) principal building: 1) a gas bar / convenience store and accessory car wash. 6.17.2 Lot Size: 1) Minimum and maximum lot width, lot depth and lot area in the CR-6 zone are as follows: Lot width 15.0m (49.21ft) Lot depth 30.5m (100.07ft) Lot area 1,114.0m² (11,990.0ft²) 6.17.3 Lot Coverage: 1) maximum lot coverage per fee-simple lot is 45%. 6.17.4 Density: 1) maximum gross floor area of all uses shall be 0.45 times the lot area. 6.17.5 Building Heights: 1) principal buildings shall not exceed a height of 7.7m. 2) ancillary buildings and structures shall not exceed a height of 4.0m (13.12ft). 3) the canopy over a gas bar pump island and a separate building containing an accessory car wash are deemed to be principal buildings for the purpose of determining height. 6.17.6 Minimum Setback Requirements: 1) Principal buildings and ancillary buildings and structures in the CR-6 zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Buildings Ancillary Buildings and Structures Front lot line 6.1m (20.0ft) 6.1m (20.0ft) Rear lot line 6.1m (20.0ft) 6.1m (20.0ft) Interior side lot line 3.0m (9.84ft) 3.0m (9.84ft) Exterior side lot line 6.1m (20.0ft) 6.1m (20.0ft) 2) Notwithstanding the above, the canopy over a gas bar pump island may be located not less than 4.5m (14.76ft) from any lot line. 6.17.7 Ancillary Buildings and Structures: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.17.5 and 6.17.6 above, the following also applies: 1) ancillary buildings and structures shall be located a minimum of 3.0m (9.85ft) from a principal building. Zoning Bylaw No. 2506 Page 83 6.17.8 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. 6.17.9 Accessory off-street loading spaces shall be provided in accordance with the provisions of sub-sections 4.15.2 and 4.15.3. Zoning Bylaw No. 2506 Page 84 6.18 P-1 Civic / Institutional Use Zone The intent of this zone is to accommodate public uses and the railway. 6.18.1 Permitted Uses: The following uses are permitted in more than one (1) principal building: 1) civic uses; 2) public utility uses; 3) child care centre; 4) community service use; 5) parks and natural areas; 6) railway use; 7) parking facilities; 8) Notwithstanding 1) to 7) above, professional and semi-professional offices are permitted on property located at 1174 Fir Street (Lot 1, Block 30, Plan 11883). 6.18.2 Lot Size: 1) Minimum and maximum lot width, lot depth and lot area in the P-1 zone are as follows: Lot width 18.0m (59.06ft) Lot depth 30.5m (100.07ft) Lot area 742.0m² (7,986.82ft²) 6.18.3 Lot Coverage: 1) maximum lot coverage per fee-simple lot is 50%. 6.18.4 Building Heights: 1) principal buildings shall not exceed a height of 10.7m. 2) ancillary buildings and structures shall not exceed a height of 6.0m (19.69ft). 6.18.5 Minimum Setback Requirements: 1) Principal buildings and ancillary buildings and structures in the P-1 zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Buildings Ancillary Buildings and Structures Front lot line 6.0m (19.69ft) 6.0m (19.69ft) Rear lot line 6.0m (19.69ft) 6.0m (19.69ft) Interior side lot line 6.0m (19.69ft) 6.0m (19.69ft) Exterior side lot line 6.0m (19.69ft) 6.0m (19.69ft) 6.18.6 Ancillary Buildings and Structures: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.18.4 and 6.18.5 above, the following also applies: 1) ancillary buildings and structures shall be located a minimum of 3.0m (9.85ft) from a principal building. Zoning Bylaw No. 2506 Page 85 6.18.7 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. 6.18.8 Accessory off-street loading spaces shall be provided in accordance with the provisions of sub-sections 4.15.2 and 4.15.3. Zoning Bylaw No. 2506 Page 86 6.19 P-2 Church / Assembly Use Zone The intent of this zone is to accommodate the use of land for religious assembly and place of worship, and for community service. 6.19.1 Permitted Uses: The following uses are permitted in more than one (1) principal building: 1) assembly use; 2) community service use; 3) a use accessory to an assembly or community service use. 6.19.2 Lot Size: 1) Minimum and maximum lot width, lot depth and lot area in the P-2 zone are as follows: Lot width 18.0m (59.06ft) Lot depth 30.5m (100.07ft) Lot area 742.0m² (7,986.82ft²) 6.19.3 Lot Coverage: 1) maximum lot coverage per fee-simple lot is 45%. 6.19.4 Building Heights: 1) principal buildings shall not exceed a height of 10.7m. 2) ancillary buildings and structures shall not exceed a height of 4.0m (13.12ft). 6.19.5 Minimum Setback Requirements: 1) Principal buildings and ancillary buildings and structures in the P-2 zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Buildings Ancillary Buildings and Structures Front lot line 6.0m (19.69ft) 6.0m (19.69ft) Rear lot line 6.0m (19.69ft) 6.0m (19.69ft) Interior side lot line 6.0m (19.69ft) 6.0m (19.69ft) Exterior side lot line 6.0m (19.69ft) 6.0m (19.69ft) 6.19.6 Ancillary Buildings and Structures: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.19.4 and 6.19.5 above, the following also applies: 1) ancillary buildings and structures shall be located a minimum of 3.0m (9.85ft) from a principal building. 6.19.7 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. 6.19.8 Accessory off-street loading spaces shall be provided in accordance with the provisions of sub-section 4.15.2 and 4.15.3. Zoning Bylaw No. 2506 Page 87 6.20 P-3 Community Care Facility (Low Density) Zone The intent of this zone is to accommodate the use of land for licensed care facilities, including assisted living residences, hospitality services, community living and long-term care equivalent to low density multi-unit residential. 6.20.1 Permitted Uses: The following uses are permitted in more than one (1) principal building: 1) assisted living residence; 2) care facility; 3) community service use; 4) health service facility; 5) hospitality services. 6.20.2 Lot Size: 1) Minimum and maximum lot width, lot depth and lot area in the P-3 zone are as follows: Lot width 18.0m (59.06ft) Lot depth 30.5m (100.07ft) Lot area 742.0m² (7,986.82ft²) 6.20.3 Lot Coverage: 1) maximum lot coverage per fee-simple lot is 45%. 6.20.4 Density: 1) maximum gross floor area of all uses shall be 0.6 times the lot area, except that the gross floor area of all uses may be increased to 0.8 times the lot area where a housing agreement for affordable and/or special needs housing has been entered into and registered on title pursuant to Section 483 of the Local Government Act. 6.20.5 Building Heights: 1) principal buildings shall not exceed a height of 7.7m. 2) structures shall not exceed a height of 4.0m. 6.20.6 Minimum Setback Requirements: 1) Principal buildings and structures in the P-3 zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Buildings Structures Front lot line 6.0m (19.69ft) 6.0m (19.69ft) Rear lot line 6.0m (19.69ft) 6.0m (19.69ft) Interior side lot line 6.0m (19.69ft) 6.0m (19.69ft) Exterior side lot line 6.0m (19.69ft) 6.0m (19.69ft) Zoning Bylaw No. 2506 Page 88 6.20.7 Ancillary Buildings and Structures: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.20.5 and 6.20.6 above, the following also applies: 1) ancillary buildings shall not be permitted; 2) structures shall not be sited less than 3.0m from a principal building on the same lot. 6.20.8 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. 6.20.9 Accessory off-street loading spaces shall be provided in accordance with the provisions of sub-sections 4.15.2 and 4.15.3. Zoning Bylaw No. 2506 Page 89 6.21 P-4 Community Care Facility (Medium Density) Zone The intent of this zone is to accommodate the use of land for licensed care facilities, including assisted living residences, hospitality services, community living and long-term care equivalent to medium density multi-unit residential. 6.21.1 Permitted Uses: The following uses are permitted in more than one (1) principal building: 1) assisted living residence; 2) care facility; 3) community service use; 4) health service facility; 5) hospitality services. 6.21.2 Lot Size: 1) Minimum and maximum lot width, lot depth and lot area in the P-4 zone are as follows: Lot width 18.0m (59.06ft) Lot depth 30.5m (100.07ft) Lot area 742.0m² (7,986.82ft²) 6.21.3 Lot Coverage: 1) maximum lot coverage per fee-simple lot is 45%. 6.21.4 Density: 1) maximum gross floor area of all uses shall be 1.1 times the lot area. 6.21.5 Building Heights: 1) principal buildings shall not exceed a height of 10.7m. 2) structures shall not exceed a height of 4.0m. 6.21.6 Minimum Setback Requirements: 1) Principal buildings and structures in the P-4 zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Buildings Structures Front lot line 6.0m (19.69ft) 6.0m (19.69ft) Rear lot line 6.0m (19.69ft) 6.0m (19.69ft) Interior side lot line 6.0m (19.69ft) 6.0m (19.69ft) Exterior side lot line 6.0m (19.69ft) 6.0m (19.69ft) 6.21.7 Ancillary Buildings and Structures: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- sections 6.21.5 and 6.21.6 above, the following also applies: 1) ancillary buildings shall not be permitted. 2) structures shall not be sited less than 3.0m from a principal building on the same lot. Zoning Bylaw No. 2506 Page 90 6.21.8 Accessory off-street parking shall be provided in accordance with the provisions of Section 4.14. 6.21.9 Accessory off-street loading spaces shall be provided in accordance with the provisions of sub-sections 4.15.2 and 4.15.3. Zoning Bylaw No. 2506 Page 91 7.0 Comprehensive Development ("CD") Zones 7.1 CD-1 COMPREHENSIVE DEVELOPMENT ZONE (Peace Arch Hospital) INTENT 1. Permitted Uses The following uses and no others shall be permitted in the CD-1 comprehensive development zone (Peace Arch District Hospital): (a) a hospital and related facilities provided or funded by a federal, provincial, regional, local government, or a non-profit society or organization; (b) a health care facility provided by a not-for-profit society or organization; (c) an accessory off-street parking use; (d) an accessory off-street loading use; (e) public and private open space and recreation areas. 2. The uses which are permitted, and no others, by parcel are: Parcel A: Hospital facilities open space and parking structures; Parcel B: Hospital facilities; Parcel C: Hospital facilities, parking structures, loading and service facilities; Parcel D: Parking structure; Parcel E: Extended care hospital facilities; Parcel F: Extended care hospital facilities; Parcel G: Open space; Parcels H,J,L: Parking and access roads; Parcel K: Parking, open space, and hospital facilities; These uses shown upon diagram 1 and form part of this Bylaw. Temporary surface parking may be used upon any portion of the site until its ultimate use is realized through an approved development and building permit. This temporary parking lot will be drained and dust free. 3. The time of the application for the first development permit application upon the site this will also be considered to be an application to construct improvements to the emergency access point to the hospital and associated parking as shown upon diagrams 4 and 6. Detailed plans for these improvements to Parcels A and B will only be required for the parking and emergency access and will form part of the first development permit issued. The remainder of Parcels A and B will be approved by a separate development permit when an application is submitted. The uses shown on diagrams 4 and 6 form part of this Bylaw. 4. DESIGN AND HEIGHT CONTROL The height, setback and angles of containment of structures shall be in conformity with Diagrams 2, 5, 7 and 8. These heights are considered to be maximum, and may be Zoning Bylaw No. 2506 Page 92 reduced at the time of a development permit application without having the comprehensive development zone amended. The maximum frontage of any one structure upon any parcel fronting unto Russell Avenue shall not exceed 50% at the setback line. 5. HANDICAP ACCESS Each and every parcel of land upon the site shall be totally handicapped accessible internal to the building and structures, access to the buildings and structures, and, for all external and outdoor open spaces in conformity with the regulations of the British Columbia Building Code. 6. OPEN SPACES Open spaces shall be provided in conformity with diagrams 3 and 4, and form part of this Bylaw. The development of these designated open spaces will occur concurrently with the development of the sites which they are a part. Parcel G, open space, will occur concurrently with the development of Parcel E. At the time of a development permit application being received, financial assurance for completion will be provided by the applicant. 7. PARKING AND TRAFFIC Parking access and internal circulation shall be provided as shown upon diagrams 6 and 7. All parking structures shall be lit and finished with a light reflective surface for security purposes. At each application for a development permit it will be verified that turning movements are adequate to the standard of the City of White Rock Fire Department. Zoning Bylaw No. 2506 Page 93 The Plans Zoning Bylaw No. 2506 Page 94 Zoning Bylaw No. 2506 Page 95 Zoning Bylaw No. 2506 Page 96 Zoning Bylaw No. 2506 Page 97 Zoning Bylaw No. 2506 Page 98 Zoning Bylaw No. 2506 Page 99 Zoning Bylaw No. 2506 Page 100 Zoning Bylaw No. 2506 Page 101 7.2 CD-2 COMPREHENSIVE DEVELOPMENT ZONE (Vidal & Beachview) INTENT The intent of this zone is to accommodate the development of a multiple-family housing complex on a site of approximately 3200 square metres (34,445 square feet). 1. Permitted Uses The following uses and no others shall be permitted in the CD-2 comprehensive development zone. (a) a two-unit residential use (b) a medium density apartment use (c) an accessory off-street parking use (d) an off-street parking use 2. Location of Permitted Uses The locations of permitted uses are shown upon: (a) Drawings A-2 and A-3 dated February 17, 1995 as prepared by H. R. Hatch Architect Ltd., Suite 601, 1587 West 8th Avenue, Vancouver, B. C., on file with the City of White Rock. 3. Site Development, Architecture and Design Criteria Architect and design requirements are shown upon drawings A-1, A-2, A-3, A-6, A-7, A- 8, A-10, A-11, A-13 and A-14 dated February 17, 1995 prepared by H. R. Hatch Architect Ltd., Suite 601, 1587 West 8th Avenue, Vancouver, B. C., and on file with the City of White Rock. 4. Landscaping Landscaping requirements are shown upon drawings L-1 and L-2 dated November 21, 1994 as prepared by H. R. Hatch Architect Ltd., Suite 601, 1587 West 8th Avenue, Vancouver, B. C., on file with the City of White Rock. 5. Heights (a) the townhouse structures shall not exceed a height of 30' from average natural grade or 51.0' at datum. (b) the apartment building located at the southern portion of the site shall not exceed a height of 35' from average natural grade or 51.25' at datum. 6. Amendments Minor amendments requiring changes to the exterior or interior of the proposed structures as shown on plans attached to and forming part of this Bylaw must be approved by the City, such approval to be authorization in writing by the City Administrator, the City Planner or the Director of Permits & Licenses. Zoning Bylaw No. 2506 Page 102 7.3 CD-3 COMPREHENSIVE DEVELOPMENT ZONE (EPCOR - Oxford & Buena Vista) INTENT The intent of this zone is to accommodate the development of a water works utility on a site of approximately 2010 square metres (21,636 square feet). 1. Permitted Uses The following uses and no others shall be permitted in the CD-3 comprehensive development zone (White Rock Utilities). (a) a water utility (b) an accessory off-street parking use (c) an accessory off-street loading use (d) an accessory storage use 2. Design and Height Control The height, setback and landscape shall be in conformity with Diagrams A.1, A.3, A.4, L.1 and S. 1 all on file with the City of White Rock. These heights are considered to be maximum, and may be reduced at the time of a development permit application without having the comprehensive development zone amended. The exterior finishing of the building will reflect the patterns and tone as set out in Diagrams A.3 and A.4. This will include siding, stucco, or similar materials. Colours shall be limited to pastels and light tones. No "new used bricks" or monochromatic paints will be accepted except for access points and directional signs. 3. Parking and Traffic Parking access and internal circulation shall be provided as shown upon Diagram L.1. Zoning Bylaw No. 2506 Page 103 7.4 CD-4 COMPREHENSIVE DEVELOPMENT ZONE (15154 - 58 Roper Avenue) INTENT The intent of this zone is to accommodate the development of a multiple-family housing complex including two live/work units on a site of approximately 807 square metres (8,685 square feet). 1. Permitted Uses The following uses and no others shall be permitted in the CD-4 Comprehensive Development zone: (a) an apartment use (b) a retail service group 1 use only, for strata lots 1 and 2; (c) an accessory off-street parking use 2. Height Limit No building or structure shall exceed a height of 10.7 metres (35.1 feet). 3. Amendments Minor amendments requiring changes to the exterior of the proposed structures and landscaping as shown on drawings A-01, A-02, A-03, A-04, A-05, A-06, A-07, A-08, A- 09, A-10 and L-1, all date stamped received November 17, 1997, must be approved by the City, such approval to be authorized in writing by the City Planner or the Director of Permits and Licenses. Zoning Bylaw No. 2506 Page 104 7.5 CD-5 COMPREHENSIVE DEVELOPMENT ZONE (15161 Prospect Avenue) INTENT The intent of this zone is to accommodate the development of a multiple-family housing complex comprising six live/work units on a site of approximately 808 square metres (8,706 square feet). 1. Permitted Uses The following uses and no others shall be permitted in the CD-5 Comprehensive Development zone: (a) an apartment use (b) a retail service group 1 use, provided that such use is contained within a single strata unit which includes a residential use (c) an accessory off-street parking use 2. Location of Permitted Uses The locations of permitted uses are shown upon Drawing A-01, date stamped received March 20, 1998, and drawings A-02, A-03, A-04, date stamped received February 4, 1998 as prepared by Linda Baker Architect, and on file with the City of White Rock. 3. Site Development, Architecture and Design Criteria Architectural and design requirements are shown upon drawings A-01, A-05, A-06, date stamped received March 20, 1998 and drawings A-02, A-03, A-04, and A-07, date stamped received February 4, 1998, as prepared by Linda Baker Architect, and on file with the City of White Rock. 4. Landscaping Landscaping requirements are shown upon drawing L1 prepared by Wendy Grandin Ltd. Landscape Architects, date stamped received March 20, 1998 and on file with the City of White Rock. 5. Height Limit No building or structure shall exceed a height of 10.7 metres (35.1 feet). 6. Amendments Minor amendments requiring changes to the exterior of the proposed structures and landscaping as shown on drawings A-01, A-05, A-06, and L-1, date stamped received March 20, 1998, and drawings A-02, A-03, A-04, A-07, date stamped received February 4, 1998 must be approved by the City, such approval to be authorized in writing by the City Planner or the Director of Permits and Licenses. Zoning Bylaw No. 2506 Page 105 7.6 CD-6 COMPREHENSIVE DEVELOPMENT ZONE (15111 - 25 Russell Avenue) INTENT The intent of this zone is to accommodate site specific mixed commercial / residential uses for an existing development within the Town Centre Area. 1. Permitted Uses: The following uses are permitted in one (1) or more principal buildings: 10) retail service group 1 uses; 11) hotel; 12) multi-unit residential use in conjunction with not more than one of the following accessory uses per dwelling unit: a) accessory home occupation in accordance with the provisions of Section 5.3.; b) accessory boarding use in accordance with the provisions of Section 5.4. Notwithstanding the above, a retail service group 1 use is limited to the 1st and 2nd stories of a building, a hotel use is limited exclusively to the story or stories above a retail service group 1 use and shall be the only use in a story so used, and, multi-unit residential uses are limited exclusively to the story or stories above a retail service group 1 use and a hotel use except in those portions of the complex where there are no retail service group 1 or hotel uses. 2. Lot Size: 1) Minimum lot width, lot depth and lot area in the CD-6 zone are as follows: Lot width 45.0m (147.6.0ft) Lot depth 62.0m (203.4ft) Lot area 2,917.0m² (21,710.0ft²) 3. Lot Coverage: 1) Maximum lot coverage per fee-simple lot is 90%. 2) Notwithstanding 1) above, lot coverage above the 1st story shall not exceed 45%. 4. Density: Maximum gross floor area (GFA) of all uses shall be 3.36 times the lot area. 5. Building Heights: 1) Principal buildings shall not exceed a height of 26.0m (85.3ft). 2) Accessory structures shall not exceed a height of 4.0m (13.12ft). 6. Minimum Setback Requirements: 1) Principal buildings and ancillary structures in the CD-6 zone shall be sited in accordance with the following minimum setback requirements: Setback Principal Building Ancillary Structures Front lot line 4.0m (13.12ft) Not permitted * Zoning Bylaw No. 2506 Page 106 Rear lot line 4.0m (13.12ft) 4.0m (13.12ft) Interior or exterior side lot line 4.0m (13.12ft) 4.0m (13.12ft) 7. Ancillary Buildings and Structures: Except as otherwise provided in Section 4.13 and in addition to the provisions of sub- section 6.15.6 above, the following also applies: 1) ancillary buildings shall not be permitted. 2) ancillary structures shall not be located closer than 3.0m (9.85ft) to a principal building. 8. Accessory off-street parking spaces shall be provided in accordance with the provisions of Section 4.14. 9. Accessory off-street loading spaces shall be provided in accordance with the provisions of sub-section 4.15.2. Zoning Bylaw No. 2506 Page 107 7.7 CD-7 COMPREHENSIVE DEVELOPMENT ZONE (14971 Prospect Avenue) INTENT The intent of this zone is to accommodate two one unit residential uses and a garden pavilion and related buildings and structures on the same lot. 1. Permitted Uses The following and no others shall be permitted in the CD-7 Zone: (a) No more than two (2) one unit residential uses to RS-1 standards (b) An accessory home occupation use (c) An accessory boarding use (d) A garden pavilion and related buildings and structures 2. Regulations for Permitted Uses of Land, Buildings and Structures (a) A one-unit residential use shall not be permitted on a lot of less than 464.0m2 (4995ft2) except where such lot was existing at the effective date of this Bylaw. (b) An accessory home occupation use shall comply with the provisions of Section 5.3. (c) An accessory boarding use shall comply with the provisions of Section 5.4. 3. Regulations for the Size, Shape and Siting of Buildings and Structures (a) Principal buildings for a one unit residential use shall comply with the provisions of Section 6.1. (b) A garden pavilion and related buildings and structures, shall conform to the drawings L-1.1, L-2.1, L-2.2, L-2.3, L-3.1, L-3.2, L-3.3, L-4.1, L-4.2, L-4.3, L-4.4, L-4.5, L-4.6, L-4.7, L-4.8, date stamped received September 27, 1999, as prepared by Hollingsworth Corporation, and on file with the City of White Rock. Zoning Bylaw No. 2506 Page 108 7.8 CD-8 COMPREHENSIVE DEVELOPMENT ZONE (15451 Russell Avenue) INTENT The intent of this zone is to accommodate the development of an office building containing medical offices, on a site of approximately 1,533 square metres (16,500 square feet). 1. Permitted Uses The following uses and no others shall be permitted in the CD-8 Comprehensive Development zone: 1) a professional office use. 2. Regulations for Permitted Uses of Land, Buildings and Structures 1) Off street parking and loading shall be provided in accordance with the retail service group 1 use requirements contained in Sections 4.14 and 4.15. 3. Regulations for the Size, Shape and Siting of Buildings and Structures Subject to the provisions of Section 403, principal buildings: (a) Shall not exceed a height of 7.7m (25.26ft). (b) Together with any accessory building shall not exceed a lot coverage of 40%. (c) The maximum gross floor area shall not exceed 0.7 times the lot area. (d) Shall be sited not less than: (i) 3.0m (9.84ft) from the front lot line, provided that a minimum setback from the front lot line of 6.7m (22ft) is provided for a minimum distance of 14.6 m (48ft) of the frontage of the principal building. (ii) 1.2 m (3.93ft) from the easterly interior lot line. (iii) 7.0m (23ft) from the westerly interior lot line. (iv) 14.0m (46ft) from the rear lot line. (e) Notwithstanding Section 4.14, the maximum permitted projection for eaves is 1.2m (3.94ft) into any side yard setback area required in paragraph (d) (ii) and (d) (iii) above. (f) Subject to the provisions of Section 403, accessory structures: (i) Shall not exceed a height of 4.0m (13.12ft). (ii) No accessory buildings shall be permitted. Zoning Bylaw No. 2506 Page 109 7.9 CD-9 COMPREHENSIVE DEVELOPMENT ZONE (15383 - 99 Russell Avenue) INTENT The intent of this zone is to accommodate the development of five one-unit residential units to a density of approximately 15 units per acre. 1. Permitted Uses The following uses and no others shall be permitted in the CD-9 Comprehensive Development zone: 1) A one-unit residential use 2) An accessory home occupation use 2. Regulations for Permitted Uses of Land, Buildings and Structures 1) A one unit residential use shall not be permitted on a lot of less than 260m2 (2,800ft2). 2) An accessory home occupation use shall comply with the provisions of Section 5.3. 3. Regulations for the Size, Shape, and Siting of Buildings and Structures 1) Principal buildings for a one-unit residential use: (i) together with an accessory building shall not exceed a lot coverage of 50%; (ii) shall not exceed a height of 10.05m (33ft) (iii) shall not exceed a maximum residential gross floor area of 0.9 times the lot area; (iv) shall be sited not less than: a. 3.0m (10ft) from the front lot line b. 1.2m (4ft) from an interior lot line c. 2.4m (7.8ft) from an exterior lot line 2) Accessory buildings and structures: (i) shall not exceed a height of 4 m (13.12ft). (ii) shall be sited to the rear of the rear face of the principal building on the lot; (iii) shall be sited not less than: a. 3.0m (9.8ft) from an exterior side lot line; b. 0.0m (0.0ft) from an interior side lot line; c. 0.5m (1.64ft) from a rear lot line; d. 0.0 metres (0 feet) from a principal building on the lot. 4. Site Development, Architecture & Design Criteria: Architectural and design requirements are shown on drawing A-1 date stamped received September 5, 2001 and on file with the City of White Rock. 5. Amendments: Minor amendments requiring changes to the exterior of the proposed structures on plan A-1 date stamped received September 5, 2001 must be approved by the City, such Zoning Bylaw No. 2506 Page 110 approval to be authorized in writing by the City Planner or the Director of Permits and Licenses. Zoning Bylaw No. 2506 Page 111 7.11 CD-11 COMPREHENSIVE DEVELOPMENT ZONE (15441 - 57 Buena Vista Ave) INTENT The intent of this zone is to accommodate the development of a bare land strata subdivision containing five detached one-unit residential buildings on a site of approximately 2,023m2 (0.5 acre). 1. Permitted Uses The following uses and no others shall be permitted: a) A one unit residential use b) an accessory home occupation use 2. Regulations for Permitted Uses of Land, Buildings and Structures (a) A one unit residential use shall not be permitted on a lot of less than 275m2 (2,960ft2). (b) An accessory home occupation use shall comply with the provisions of Section 5.3. 3. Regulations for the Size, Shape and Siting of Buildings and Structures a) Principal buildings for a one unit residential use: i) Together with an accessory building shall not exceed a lot coverage of 50% as measured on each strata lot; ii) shall not exceed a height of 7.7m (25.26ft); iii) shall not exceed a residential floor area of 0.7 times the area of the strata lot; iv) shall be sited not less than: a. for the strata lots fronting onto Buena Vista Avenue, 7.0m from the front lot line, and for the strata lots not fronting onto Buena Vista Avenue, 5.48m from the front lot line, for each of the strata lots; b. for the strata lots fronting onto Buena Vista Avenue, 5.48m from the rear lot line, and for the strata lots not fronting onto Buena Vista Avenue, 7.5m from the rear lot line, for each of the strata lots; c. for all strata lots, 1.2m from an interior side lot line. b) Accessory buildings and structures: i) Shall not exceed a height of 3.0m (9.84ft); ii) Shall not exceed a gross floor area of 6.0 m2 (64ft2); iii) Shall be sited to the rear of the principal building on the lot; iv) Shall be sited not less than: a. 1.2m from an interior side lot line; b. 1.5 m from a rear lot line; c. 1.5 m from a principal building on the lot. 4. Architectural and Design Criteria Zoning Bylaw No. 2506 Page 112 Architectural and design requirements are shown on drawings G.0 101, G.0 103, and Elevations, date stamped received October 7, 2002, as prepared by Grafic Square Designers, and on file with the City of White Rock. Landscape development shall be in accordance with the design concept shown on Plan G.0 101, date stamped received October 7, 2002, as prepared by Grafic Square Designers, and on file with the City of White Rock. 5. Amendments Minor amendments requiring changes to the exterior of the proposed structures and landscaping as shown on drawings G.0 101, G.0 103, and Elevations, date stamped October 7, 2002, must be approved by the City, such approval to be authorized in writing by the City Planner. Zoning Bylaw No. 2506 Page 113 7.12 CD-12 COMPREHENSIVE DEVELOPMENT ZONE (open for use) Zoning Bylaw No. 2506 Page 114 7.13 CD-13 COMPREHENSIVE DEVELOPMENT ZONE (15164 Prospect Avenue) INTENT The intent of this zone is to accommodate the development of a multi-unit residential building on a site of approximately 1590 m2. 1. Permitted Uses The following uses and no others shall be permitted in the CD-13 zone: (a) An apartment use (b) An accessory home occupation use. 2. Location of Permitted Uses The locations of permitted uses are shown upon drawing A1.0 as prepared by Rositch Hemphill Architects, date stamped received February 20, 2003 and on file with the City of White Rock. 3. Regulations for Size, Shape and Siting of Buildings and Structures Principal buildings: (a) Shall not exceed a height of 11.93m (39.14 feet). (b) Shall not exceed a maximum residential floor area of 2,703.5m2 (29,101 square feet); (c) Shall be sited in accordance with the setbacks indicated on drawing A1.0 prepared by Rositch Hemphill Architects, received February 20, 2003 and on file with the City of White Rock. 4. Architectural and Design Criteria Architectural and Design Requirements are shown upon drawings A1.0, A3.0, A3.1, A3.2 and L1 date stamped received February 20, 2003 and on file with the City of White Rock. 5. Amendments Minor amendments requiring changes to the exterior of the proposed building as shown on drawings A1.0, A3.0, A3.1, and A3.2, all date stamped received February 20, 2003, must be approved by the City, such approval to be authorized in writing by the City Planner. Zoning Bylaw No. 2506 Page 115 7.14 CD-14 COMPREHENSIVE DEVELOPMENT ZONE (Martin, Foster, & North Bluff) INTENT : The intent of this zone is to accommodate the development of a phased residential/commercial development in the Town Centre area on a site of approximately 1 ha (2.4 acres). 1. Permitted uses The following uses and no others shall be permitted in the CD-14 Zone: (a) an apartment use (b) a retail service group 1 use (c) an accessory off-street parking use (d) a civic use. 2. Location of Permitted Uses The locations of permitted uses are shown upon Plan A attached to and forming part of this Bylaw. A retail service group 1 use shall be limited to the first and second story. 3. Regulations for Size, Shape and Siting of Buildings and Structures (a) Principal buildings: i) shall not exceed a height of 27.4m for Buildings 1 and 4, and a height of 26.0m for Buildings 2 and 3, as identified on Plan A; ii) shall be sited in accordance with the setbacks indicated on Plan A; iii) shall be sited in accordance with the angle of containment indicated on Plan B; (b) subject to the provisions of Section 403, accessory buildings and structures: i) shall not exceed a height of 7.5m; ii) shall be sited in accordance with the setbacks indicated on Plan A. 4. Architectural and Design Criteria Architectural and design requirements are shown on drawings ADP 12, ADP 13, Perspective A and Perspective B, date stamped received October 7, 2002, as prepared by Robert Ciccozzi Architecture Inc., and on file with the City of White Rock. Landscape development shall be in accordance with the design concept shown on Plan L-1, date stamped received October 7, 2002, as prepared by Eckford and Associates Landscape Architects, and on file with the City of White Rock. 5. Amendments Minor amendments requiring changes to the exterior of the proposed structures and landscaping as shown on drawings ACP 12, ADP 13, Perspective A, Perspective B, and L- 1, date stamped October 7, 2002, must be approved by the City, such approval to be authorized in writing by the City Planner. Zoning Bylaw No. 2506 Page 116 The Plans Zoning Bylaw No. 2506 Page 117 PLAN B: ANGLE OF CONTAINMENT Zoning Bylaw No. 2506 Page 118 7.15 CD-15 COMPREHENSIVE DEVELOPMENT ZONE (1347 Best Street) INTENT The intent of this zone is to allow medium density apartments to a maximum residential gross floor area of 1.1 times the area of the lot. 1. Permitted Uses The following uses and no others shall be permitted in the CD-15 Zone: (a) An apartment use (b) An accessory home occupation use 2. Regulations for Permitted Uses of Land, Buildings and Structures An apartment use is permitted in not more than one principal building on the lot. (a) An accessory home occupation use shall comply with the provisions of Section 404. (b) Off street parking and loading shall be provided in accordance with the provisions of Section 402. 3. Regulations for the Size, Shape and Siting of Buildings and Structures (a) Principal buildings for an apartment use: (i) together with accessory buildings shall not exceed a lot coverage of 45%; (ii) shall not exceed a height of 10.7 metres (35.1 feet); (iii) shall not exceed a residential floor area of 1.1 times the lot area, provided that: a. where common recreational facilities are provided within a principal building, for the exclusive use of the tenants, the permitted residential floor area may be increased by 1.0 times the area of such recreational facility, not to exceed 37 square metres (400 square feet); b. where storage or laundry facilities or both are provided within the individual dwelling unit, the permitted residential floor area may be increased by 1.0 times the area of such facilities but not to exceed 5.6 square metres (60.28 square feet) each per dwelling unit; (iv) shall be sited in accordance with the provisions of a Development Permit. (v) shall have a minimum dwelling unit size as set out in Section 403 6. (b) Accessory structures: (i) shall not exceed a height of 4.0m (13.12ft). (ii) shall be sited in accordance with the provisions of a Development Permit. (iii) no accessory buildings shall be permitted with the exception of gazebos. Zoning Bylaw No. 2506 Page 119 7.16 CD-16 COMPREHENSIVE DEVELOPMENT ZONE (Johnston, Thrift & Russell) INTENT The intent of this zone is to accommodate the development of a phased commercial / residential development including civic uses in the Town Centre area on a site of approximately 1.45ha (3.57ac). 1. Permitted Uses In the CD-16 Zone the following uses are permitted and all other uses are prohibited: (a) an apartment use (b) a townhouse use (c) a retail service group 1 (d) a licensed establishment, including liquor primary, food primary, agency store, liquor store, u-brew or u-vin (e) a civic use (f) an accessory home occupation use subject to the provisions of Section 5.3. 2. Location of Permitted Uses (a) The location of each permitted use shall be in accordance with the Plans and as follows: (i) A retail service group 1 use must only be located in the first or second story of a building; (ii) A townhouse use shall be located as generally shown and labelled as CH ("City Homes") on the Plans attached herein and forming part of this bylaw. Notwithstanding, the areas shown for townhouse use may be considered for ground level retail or live/work, and upper level office use; and (iii) A civic use may be located on the 1st or 2nd floor. 3. Density: (a) BASE DENSITY: The maximum number of dwelling units, gross floor areas and lot coverage of buildings and structures shall be in accordance with the following: Phase Area (1) Maximum number of Dwelling Units Maximum gross floor area(2) for a residential use (includes apartments, townhouses(4), and amenity areas(3)) Maximum gross floor area(2) for Retail Service Group 1(4), Licensed Establishment, and Civic Uses Maximum gross floor area(2) for commercial, civic and residential uses Maximum Lot Coverage 1 129 13,846 m2 1,162 m2 15,008 m2 33% 2 96 10,553 m2 2,438 m2 12,991 m2 64% 3 202 24,106 m2 4,662 m2 28,768 m2 53.4% Total for all Phases 427 48,505 m2 8,262 m2 56,767 m2 52% Zoning Bylaw No. 2506 Page 120 1. As indicated on the Plans 2. Excludes unenclosed balconies, stairwells, elevator shafts, common corridors, and enclosed parking areas. Further excludes 100 m2 of floor area in a mezzanine space used for commercial purposes within Phase 3, provided the mezzanine complies with the requirements of mezzanine spaces in the BC Building Code. 3. Means common storage and recreational amenity areas provided for the exclusive use of the residential tenants 4. Townhouse floor area may be considered for retail service group 1 use as outlined in Section 7.16.2 (ii). (b) ADDITIONAL (BONUS) DENSITY: If, prior to applying for a Building permit for construction of a Building on the subject lands, the Owner of parcels to which this zone applies provides the City with cash in lieu of community amenities, having a minimum value of $436,471, to assist with the provision of the amenities in the following table, the maximum number of dwelling units in Phase 3 shall be: (i) 248 apartment dwelling units, and (ii) 10 townhouse dwelling units labelled as CH ("City Homes") on the Plans and described as a townhouse use as outlined in Section 7.1.6.2(ii). # Amenity 1 Sanitary sewer system improvements The amenity must be provided in accordance with an amenity agreement and section 219 covenant delivered by the owner of the subject real property, to secure the amenity. 4. Regulations for Size, Shape, and Siting of Buildings and Structures Reference to a numbered Building refers to the building labelled that specific number on the Plans. (a) As indicated on the Plans, principal buildings: (a) shall not exceed a height of: 1. 178.2m geodetic for Building 1; 2. 167.5m geodetic for Building 2; 3. 158.2m geodetic for Building 3; 4. 161.7m geodetic for Building 4; (b) shall be sited in accordance with the setbacks from a property line, as shown on the Plans; (b) Accessory buildings and structures: (i) shall not exceed a height of 7.5 m; (ii) shall be sited in accordance with the setbacks from a property line, as shown on the Plans; 5. Parking and Loading Parking and Loading shall be provided as follows: (i) Residential uses, including apartments and townhouses, at 1.8 spaces per dwelling unit, inclusive of 0.2 parking spaces to be designated for visitors parking; Zoning Bylaw No. 2506 Page 121 (ii) Retail service group 1 uses and civic uses at 1.0 parking spaces for every 37 m2 of gross floor area; (iii) Parking spaces for persons with disabilities shall be provided at a ratio of 3 spaces for 1st 200 parking spaces, and one space for each additional 100 spaces. All other provisions of Sections 4.14 and 4.15 apply. 6. General Drawings attached hereto prepared by NSDA Architects: - A-001 July 30, 2010 - L-1.0 July 30, 2010 - A-601 July 30, 2010 on file with the City of White Rock; and for the purposes of this zone are referred to as "the Plans". Development in this zone shall conform substantially to the Plans. Zoning Bylaw No. 2506 Page 122 The Plans Zoning Bylaw No. 2506 Page 123 Zoning Bylaw No. 2506 Page 124 Zoning Bylaw No. 2506 Page 125 7.17 CD-17 COMPREHENSIVE DEVELOPMENT ZONE (1400/20 Johnston Rd) INTENT The intent of this zone is to accommodate a mixed-use (residential/commercial) development on a site of approximately 2,250 square metres in area. 1. Permitted Uses: (a) multi-unit residential use (b) retail service group 1 use (c) licensed establishments, including liquor primary, food primary, agency store, liquor store, u-brew, u-vin, and licensed manufacturer (d) accessory home occupation use in accordance with the provisions of section 5.3 and that does not involve clients directly accessing the principal building 2. Density: (a) maximum gross floor area shall not exceed 4,660 square metres (b) the maximum number of dwelling units must not exceed 36 3. Building Height: (a) The principal building shall not exceed a height of 124.14 metres geodetic 4. Parking: Parking shall be provided in accordance with Section 4.14, with the minimum number of spaces required as follows: (a) A minimum of 43 spaces shall be provided for the residential dwelling units (b) A minimum of 10 spaces shall be provided for visitors and marked as 'visitor' (c) A minimum of 42 spaces shall be provided for the retail service group 1 uses and licensed establishment uses 5. General: (a) Development in this zone shall substantially conform to the Plans prepared by Rositch Hemphill and Associates Architects dated June 25, 2012 that are attached hereto and on file at the City of White Rock Zoning Bylaw No. 2506 Page 126 Zoning Bylaw No. 2506 Page 127 Zoning Bylaw No. 2506 Page 128 Zoning Bylaw No. 2506 Page 129 Zoning Bylaw No. 2506 Page 130 Zoning Bylaw No. 2506 Page 131 7.18 CD-18 COMPREHENSIVE DEVELOPMENT ZONE (1115 Stayte Road) INTENT The intent of this zone is to allow business and professional office uses and a one-unit residential use 1. Definitions For the purposes of this zone the following definition applies: (a) a business and professional office use means the use of a building, or portion of a building, for administrative, clerical and professional work. Business and professional offices include financial, real estate, insurance, medical, dental, legal, design, accounting, advertising, consulting, telecommunications, high technology, and similar types of businesses engaged in person to person, person to business, and business to business transactions 2. Permitted Uses In the CD-18 Zone the following uses are permitted and all other uses are prohibited: (a) a business and professional office use (b) a one-unit residential use 3. Regulations for Permitted Uses of Land, Buildings and Structures (a) A business and professional office use shall be contained within one sales floor area having one business license and being on the ground floor only and not exceeding 0.15 times the area of the lot; (b) Off street parking and loading shall be provided in accordance with the provisions of Sections 4.14 and 4.15, and additionally, as follows: (i) parking for a business and professional office use shall be provided at 1 space for each 37.0m2 of gross floor area for a business and professional office use. (c) A one-unit residential use: (i) shall not be permitted on a lot of less than 464.0m2 (4,994.62ft2); (ii) shall be limited exclusively to the story or stories above the first story of a building; (d) The maximum allowable size of a lot shall be 1,120m2 (12,056ft2) in area. 1. Regulations for the Size, Shape and Siting of Buildings and Structures (a) Principal buildings: (i) shall not exceed a lot coverage of 45%; (ii) shall not exceed a height of 7.7m (25.26ft); (iii) shall be sited not less than: a. 7.5m (24.61ft) from front and rear lot lines; b. 1.5m (4.92ft) from an interior side lot line; c. 7.5m (24.61ft) from an exterior side lot line where the rear lot line abuts or faces the interior side lot line of the adjacent lot. Zoning Bylaw No. 2506 Page 132 (b) Accessory building and structures: (i) accessory structures shall not exceed a height of 4 metres (13.12 feet); (ii) accessory structures shall be sited not less than: a. 1.5m (4.92ft) from a rear lot line; b. 1.5m (4.92ft) from an interior side lot line; c. 7.5m (24.61ft) from an exterior side lot line; d. 2.4m (7.87ft) from a rear lot line abutting a lane; (iii) accessory buildings shall not exceed a maximum area of 6.0m2 (64.56ft2); (iii) accessory buildings shall not exceed a height of 4.0m (13.12ft); Zoning Bylaw No. 2506 Page 133 7.19 CD-19 COMPREHENSIVE DEVELOPMENT ZONE (1550 Oxford) INTENT The intent of this zone is to accommodate a complex care facility on a site of approximately 2.46 hectares (6.1 acres) in area. 2. Permitted Uses: (a) care facility (b) independent living use (c) assisted living residence (d) assembly use (e) hospitality service use 2. Lot Coverage: (a) lot coverage shall not exceed 29.4% 3. Units/Beds: (a) maximum number of independent living units = 110 (b) maximum number of assisted living units = 84 (c) maximum number of complex care bed units = 252 (d) maximum number of visitor accommodation units = 2 4. Building Height: (a) maximum height of principal buildings as identified on the attached Plans: (i) Building 'A' = 122.8 m geodetic (ii) Building 'B' = 114.35 m geodetic (iii) Building 'C' = 127.08 m geodetic (iv) Building 'D' = 108.69 m geodetic (b) permitted projections beyond the maximum heights outlined above are as outlined in Section 4.13.4 5. Siting Requirements: (a) minimum setbacks are as follows: (i) from front (west) lot line = 12.4 m (40.7 ft) (ii) from rear (east) lot line = 7.32 m (24.0 ft) (iii) from interior (north) lot line = 6.69 m (21.9 ft) (iv) from interior (south) lot line = 6.43 m (21.1 ft) (b) siting exceptions are as outlined in Section 4.13.1 6. Parking: Zoning Bylaw No. 2506 Page 134 (a) parking shall be provided in accordance with Section 4.14, with a minimum of 173 parking spaces 7. Loading: (a) loading shall be provided in accordance with Section 4.15, with a minimum of two (2) loading spaces 8. General: (b) Development in this zone shall substantially conform to the Plans prepared by Ankenman Associates Architects Inc. dated September 28, 2016, that are attached hereto and on file at the City of White Rock Zoning Bylaw No. 2506 Page 135 Zoning Bylaw No. 2506 Page 136 7.20 CD-20 COMPREHENSIVE DEVELOPMENT ZONE (991 Stayte Road) INTENT The intent of this zone is to allow neighborhood-oriented retail service uses and a one-unit residential use. 1. Definitions For the purposes of this zone the following definitions apply: (a) an artisan shop means the enclosed use of buildings and structures for the purpose of selling, processing, assembling, wholesaling, manufacturing, storing, repairing or producing artisan paintings, photography, woodworking, drawings, hand crafted items including knitting, weaving, silk screening or print screening, pottery, fired ceramics or sculpture for the ultimate consumer, and may include instructional classes or workshops. (b) a retail service use means a use providing for the sale at retail or repair of household or personal goods or things, or for extending services to persons; and is limited to: health clubs, appliance stores, art galleries, artisan shops, bakery shops, barbers, book shops, business offices, business schools, cafes, camera shops, clothing stores, coffee houses, dance studios, delicatessens, department stores, drug stores, dry cleaners, finance offices, grocery stores, hairdressers, hardware, home furnishing stores, launderettes, meat markets, neighbourhood convenience stores, personal furnishing shops, printers, professional and semi-professional offices, restaurants, secondhand stores, shoemakers, stationary stores, tailors, toy stores, trade school and variety stores. 2. Permitted Uses In the CD-20 Zone the following uses are permitted and all other uses are prohibited: (a) a retail service use (b) a one-unit residential use 3. Regulation for Permitted uses of Land, Buildings and Structures (a) A retail service use shall be limited exclusively to the first story of a building; (b) Off street parking and loading shall be provided in accordance with the provisions of Sections 4.14 and 4.15. (c) A one-unit residential use: (i) shall not be permitted on a lot of less than 464.0m2 (4,994.62ft2); (ii) shall be limited exclusively to the story or stories above the first story of a building; (d) The maximum allowable size of a lot shall be 1,120.0m2 (12,056.0ft2) in area. 4. Regulations for the Size, Shape and Siting of Buildings and Structures (a) Principal buildings: (ii) shall not exceed a lot coverage of 45%; (iii) shall not exceed a height of 7.7m (25.26ft); (iv) shall be sited not less than: a. 7.5m (24.61ft) from front and rear lot lines; Zoning Bylaw No. 2506 Page 137 b. 1.5m (4.92ft) from an interior side lot line; c. 7.5m (24.61ft) from an exterior side lot line where the rear lot line abuts or faces the interior side lot line of the adjacent lot; (b) Accessory buildings and structures: (i) accessory structures shall not exceed a height of 4.0m (13.12ft); (ii) accessory structures shall be sited not less than: a. 1.5m (4.92ft) from a rear lot line; b. 1.5m (4.92ft) from an interior side lot line; c. 7.5m (24.61ft) from an exterior side lot line; d. 2.4m (7.87ft) from a rear lot line abutting a lane; (iii) accessory buildings shall not exceed a height of 4.0m (13.12ft); (iv) accessory buildings shall not exceed a maximum area of 6.0m2 (64.56ft2). Zoning Bylaw No. 2506 Page 138 7.21 CD-21 COMPREHENSIVE DEVELOPMENT ZONE (Thrift, Everall, Goggs) INTENT The intent of this zone is to accommodate a residential development on a site of approximately 0.76ha (1.89ac) 1. Permitted Uses In the CD-21 Zone the following uses are permitted and all other uses are prohibited: (a) multi-unit residential use in the form of an apartment (b) accessory home occupation use in accordance with the provisions of Section 5.3 2. Regulations for Permitted Uses of Land, Buildings and Structures (a) The location of each permitted use shall be in accordance with the Plans and as follows: (i) An apartment or townhouse use is permitted in one or more principal buildings on the lot; (ii) An accessory home occupation use shall comply with the provisions of Section 404. 3. Number of Dwelling Units / Gross Floor Area / Lot Coverage The maximum number of dwelling units, gross floor area and lot coverage of buildings and structures shall be in accordance with the following: Maximum number of Dwelling Units Maximum gross floor area1 Maximum Lot Coverage 87 10,906.2 m2 42.0% 4. Regulations for Size, Shape, and Siting of Buildings and Structures Reference to a numbered Building refers to the building labeled that specific number on the Plans. (a) As indicated on the Plans, principal buildings: (i) shall not exceed a height of 101.7m geodetic for Building 1 and 104.98 m geodetic for Building 22; (ii) shall be sited in accordance with the setbacks from a property line as shown on the Plans. (b) Accessory buildings and structures: (i) shall not exceed a height of 4.0 m; (ii) shall be sited in accordance with the setbacks from a property line as shown on the Plans. 1 Excludes unenclosed balconies. 2 The heights of buildings and structures permitted in this zone may be exceeded for elevator shafts and stair towers which do not provide direct access to the roof; retaining walls; antennas; church spires, belfries and domes; chimneys; flag poles, and; scenery lofts. Zoning Bylaw No. 2506 Page 139 5. Parking and Loading Parking and Loading shall be provided in accordance with the provisions of Sections 4.14 and 4.15, and, the minimum number of parking spaces shall be 174. 6. Subdivision Minimum lot area in this zone shall be 7,600m2. No other lot maybe created through subdivision but existing legal parcels or portions thereof may be consolidated to support this development. 7. General Drawings attached hereto prepared by Ankenman Associates Architect Inc A1.01, A3.0, A3.01, A3.02, A3.03A, A3.03B dated May 15, 2008 on file with the City of White Rock and for the purposes of this zone are referred to as "the Plans". 8. Development in this zone shall conform substantially to the Plans. Zoning Bylaw No. 2506 Page 140 The Plans Zoning Bylaw No. 2506 Page 141 Zoning Bylaw No. 2506 Page 142 Zoning Bylaw No. 2506 Page 143 Zoning Bylaw No. 2506 Page 144 7.22 CD-22 COMPREHENSIVE DEVELOPMENT ZONE (open for use) Zoning Bylaw No. 2506 Page 145 7.23 CD-23 COMPREHENSIVE DEVELOPMENT ZONE (Johnston - George) INTENT The intent of this zone is to accommodate the development of a mixed-use residential development in the Town Centre area on an overall site of approximately 0.27 ha. (0.66 ac.), comprised of two separate buildings, with a residential development on George Street and a commercial and residential development on Johnston Road. 1. Permitted Uses: (a) multi-unit residential use; (b) general office use; (c) accessory home occupation in accordance with the provisions of Section 5.3 and that does not involve clients directly accessing the building; 2. Location of Permitted Uses: The location of each permitted use shall be in accordance with the Plans and as follows: (a) A general office use shall only be located on the first storey of the building on the property referred to as 1456 Johnston Road as shown on the Plans; (b) A multi-unit residential use shall only be located above the first storey of a building on the property referred to as 1456 Johnston Road as shown on the Plans; and on the property referred to as 1455 George Street as shown on the Plans. 3. Density and Lot Coverage for 1455 George Street: The maximum gross floor areas and lot coverage of buildings and structures at 1455 George Street shall be in accordance with the following: (a) Density: The maximum gross floor area shall not exceed 9,758 square metres, and the maximum number of dwelling units shall not exceed 108. (b) Lot Coverage: The maximum lot coverage shall not exceed 44.5%. 4. Density and Lot Coverage for 1456 Johnston Road: (a) Density: Maximum gross floor area shall not exceed 2,611 square metres, and the maximum number of dwelling units shall not exceed 29, comprised as follows: (i) BASE DENSITY: The maximum gross floor area shall not exceed 606.9 square metres, and the maximum number of dwelling units shall not exceed four units (ii) ADDITIONAL (BONUS) DENSITY: Where a contribution of $506,000 has been provided to the Community Amenity Reserve Fund to assist with the provision of the amenities in the following table, with $240,000 of this being designated for the creation of new publically accessible off-street parking, and a housing agreement has been entered into and filed with the Zoning Bylaw No. 2506 Page 146 Land Title Office on the subject real property to secure twelve (12) dwelling units with a minimum aggregate 876 square metres (9,434 square feet) residential floor area as rental tenure for the life of the building, the maximum gross floor area shall not exceed 2,611 square metres, and the maximum number of dwelling units shall not exceed 29 units. # Amenity 1 New public open space and walkways 2 Improvement of existing open space and walkways 3 Public art 4 Waterfront improvements 5 Civic parking facilities 6 Building or space within a building for civic uses 7 Special needs or non-market affordable housing 8 People movement infrastructure to link Uptown to the Waterfront The amenity must be provided in accordance with an amenity agreement and a section 219 covenant delivered by the owner of the subject real property to secure the amenity (b) Lot Coverage: The maximum lot coverage shall not exceed 69%. 5. Regulations for Size, Shape, and Siting of Buildings and Structures: (b) As indicated on the Plans, principal buildings: i) shall not exceed 130.73 metres geodetic for the building at 1456 Johnston Road, and 156.5 metres geodetic for the building at 1455 George Street; and ii) shall be sited in accordance with the setbacks from a property line as shown on the Plans. (c) Accessory buildings and structures: i) shall not exceed a height of 4.0 m; and ii) shall be sited in accordance with the setbacks from a property line as show on the Plans. 6. Parking: Parking shall be provided in accordance with Section 4.14 with the minimum total number of 163 spaces required as follows: (a) A minimum of 120 spaces shall be provided for the building at 1455 George Street. (b) A minimum of 32 spaces shall be provided for the residential dwelling units at 1456 Johnston Road (c) A minimum of three (3) space shall be provided for visitors to the residential dwelling units at 1456 Johnston Road and marked as 'visitor' (d) A minimum of eight (8) spaces shall be provided for the general office use at 1456 Johnston Road. Zoning Bylaw No. 2506 Page 147 (e) A minimum of two (2) of the required 42 spaces at 1456 Johnston Road shall be provided for disabled persons parking and shall be clearly marked in accordance with B.C. Building Code requirements. 7. Loading: (a) A total of 1 loading spaces shall be provided for residential and commercial uses, with dimensions provided in accordance with Section 4.15. 8. Bicycle Parking: Bicycle parking shall be provided in accordance with Section 4.16, with the minimum number of spaces required as follows: (a) A minimum of 36 Class I spaces shall be provided (b) A minimum of 6 Class II spaces shall be provided 9. General: (c) Development in this zone that pertain to the building located on the property at 1456 Johnston Road shall substantially conform to the Plans prepared by Ankenman Associates Architects Inc. that are attached hereto and labelled A2.2, A3.1 and A3.2 dated December 14, 2017 that are attached hereto and on file at the City of White Rock. Development on the property at 1456 Johnston Road that does not include the additional (bonus) density referred to in Section 3 shall be required to obtain a new Major Development Permit. (d) Development in this zone that pertain to the building located on 1456 Johnston Road shall substantially conform to the Plans prepared by Ankenman Associates Architects Inc. dated December 14, 2017 that are attached hereto and labelled A2.2, A3.1 and A3.2, on file at the City of White Rock. (e) Development in this zone that pertain to the building located at 1455 George Street shall substantially conform to the Plans prepared by Chris Dikeakos Architects Inc. that are attached hereto and labelled A102, A300, and A301, no date, on file with the City of White Rock. Zoning Bylaw No. 2506 Page 148 Zoning Bylaw No. 2506 Page 149 Zoning Bylaw No. 2506 Page 150 Zoning Bylaw No. 2506 Page 151 Zoning Bylaw No. 2506 Page 152 Zoning Bylaw No. 2506 Page 153 Zoning Bylaw No. 2506 Page 154 7.24 CD-24 COMPREHENSIVE DEVELOPMENT ZONE (15109 Buena Vista Ave) INTENT The intent of this zone is to accommodate a personal care facility on a site of approximately 0.08ha (0.20ac) 1. Permitted Uses In the CD-24 Zone the following uses are permitted and all other uses are prohibited: (a) personal care use 2. Regulations for Permitted Uses of Land, Buildings and Structures (a) Off street parking and loading shall be provided in accordance with the provisions of Sections 4.14 and 4.15 with the following exception: (i) notwithstanding the provisions of Section 4.15, an off-street loading space is not required for a personal care use; (b) The maximum number of sleeping units for a personal care use shall be 12. 3. Regulations for Size, Shape, and Siting of Buildings and Structures (a) Principal buildings: (i) together with accessory buildings shall not exceed a lot coverage of 45%; (ii) shall not exceed a height of 7.7m (25.26ft); (iii) shall not exceed a residential gross floor area of 0.6 times the lot area; (iv) shall be sited not less than: a. 8.0m (26.25ft) from a front lot line; b. 11.0m (36.09ft) from a rear lot line; c. 4.0m (13.12ft) from an interior side lot line; d. 0.6m (1.97ft) from an exterior side lot line; (b) Notwithstanding Section 403(6), sleeping units for a personal care use: (i) shall have a minimum size of 10.5m² (113ft²) (c) Accessory buildings and structures: (i) shall not exceed a height of 4.0m (13.12ft); (ii) shall be sited to the rear of the rear face of the principal building on the lot; (iii) shall be sited not less than: a. 1.2m (3.94ft) from a rear lot line; b. 0.8m (2.62ft) from an interior side lot line; c. 6.9m (22.64ft) from an exterior side lot line; 4. Subdivision Minimum lot area in this zone shall be 801m². No other lot may be created through subdivision but existing legal parcels or portions thereof may be consolidated. Zoning Bylaw No. 2506 Page 155 7.25 CD-25 COMPREHENSIVE DEVELOPMENT ZONE (1456 Everall Street) INTENT The intent of this zone is to accommodate the development of a nine (9) unit residential townhouse complex on a site of approximately 0.19ha (0.47ac) 1. Permitted Uses In the CD-25 Zone the following uses are permitted and all other uses are prohibited: (a) A townhouse use (b) An accessory home occupation use 2. Location of Permitted Uses The location of permitted use shall be in accordance with the Plans and as follows: (a) A townhouse use is permitted in one or more principal buildings on the lot; (b) An accessory home occupation use shall comply with the provisions of Section 5.3. 3. Number of Dwelling Units / Gross Floor Areas / Lot Coverage The maximum number of dwelling units and lot coverage of buildings and structures shall be in accordance with the following: (a) Maximum No. of dwelling units = nine (9) (b) Maximum lot coverage = 31.0% 4. Regulations for Size, Shape, and Siting of Buildings and Structures Reference to a Building refers to the building labeled that specific number on the Plans. As indicated on the Plans, principal buildings are identified as Blocks A, B and C: (a) Maximum height of buildings, and property line setbacks for Block A are as follows: (i) Maximum height of buildings = 12.03m (39.5ft) (ii) Setback from front lot line = 4.572m (15.0ft) (iii) Setback from rear lot line = as shown on plan (iv) Setback from south interior lot line = 2.4m (7.87ft) (b) Maximum height of buildings, and property line setbacks for Block B are as follows: (i) Maximum height of buildings = 11.41m (37.4ft) (ii) Setback from front lot line = 4.572m (15.0) (iii) Setback from rear lot line = as shown on plan (iv) Setback from north interior lot line = 2.4m (7.87ft) (c) Maximum height of buildings, and property line setbacks for Block C are as follows: (i) Maximum height of buildings = 10.37m (34.0ft) (ii) Setback from front lot line = as shown on plan (iii) Setback from rear lot line = 6.0m (19.7ft) (iv) Setback from north interior lot line = 1.2m (3.94ft) (d) Maximum projections into the above property line setback requirements shall be as outlined in Section 4.14, except that: (i) a cantilevered floor area may extend not more than 0.3m (0.98) into an interior side yard; Zoning Bylaw No. 2506 Page 156 (ii) an open porch or balcony may extend not more than 1.68m (5.5) into a front or rear yard setback. (e) Accessory buildings and structures: (i) shall not exceed a height of 4.0m (13.1ft). 5. Parking and Loading Parking and Loading shall be provided in accordance with Sections 4.14 and 4.15, and, additionally as follows: (a) Two (2) enclosed parking spaces shall be provided for each dwelling unit as shown on the plans identified as garage for each dwelling unit; (b) Three (3) visitor parking spaces, including one (1) handicap accessible parking space, shall be provided as shown on the plans. 6. General Drawings attached hereto prepared by Gerry Blonski, Architect, and LandSpace Design Inc., Landscape Architect, on file with the City of White Rock as shown on the attached plans; and for the purposes of this zone are referred to as "the Plans". 7. Development in this zone shall conform substantially to the Plans. Zoning Bylaw No. 2506 Page 157 The Plans Zoning Bylaw No. 2506 Page 158 Zoning Bylaw No. 2506 Page 159 Zoning Bylaw No. 2506 Page 160 Zoning Bylaw No. 2506 Page 161 Zoning Bylaw No. 2506 Page 162 Zoning Bylaw No. 2506 Page 163 Zoning Bylaw No. 2506 Page 164 7.28 CD-28 COMPREHENSIVE DEVELOPMENT ZONE (1434 Everall Street) INTENT The intent of this zone is to accommodate the development of a five (5) unit residential townhouse complex on a site of approximately 0.1 (0.23 ac) 1. Permitted Uses In the CD-27 Zone the following uses are permitted and all other uses are prohibited: (a) multi-unit residential uses in the form of a townhouse and may be permitted in one or more principal buildings. (b) An accessory home occupation use subject to the provisions of section 5.3. 2. Number of Dwelling Units / Gross Floor Areas / Lot Coverage The maximum number of dwelling units and lot coverage of buildings and structures shall be in accordance with the following: (a) Maximum No. of dwelling units = five (5 ) (b) Maximum Lot Coverage = 31.0% 3. Regulations for Size, Shape, and Siting of Buildings and Structures Reference to a Building refers to the building labeled that specific number on the Plans. As indicated on the Plans, principal buildings are identified as Blocks A and B: (a) Maximum height of buildings, and property line setbacks for Block A are as follows: (i) Maximum height of buildings = 11.7m (38.4ft) (ii) Setback from front lot line = 4.57m (15.0ft) (iii) Setback from rear lot line = as shown on plan (iv) Setback from south interior lot line = 1.2m (3.94ft) (b) Maximum height of buildings, and property line setbacks for Block B are as follows: (i) Maximum height of buildings = 11.4m (37.4ft) (ii) Setback from rear lot line = as shown on plan (iii) Setback from north interior lot line = 2.0m (6.56ft) (c) Maximum projections into the above property line setback requirements shall be as outlined in Section 4.14, except that: (i) a cantilevered floor area may extend not more than 0.3m (1.0ft) into an interior side yard; (ii) an open porch or balcony may extend not more than 1.68m (5.5ft) into a front or rear yard setback. (d) Ancillary buildings and structures shall not exceed a height of 4.0 m. 4. Parking and Loading Parking and Loading shall be provided in accordance with Sections 4.14 and 4.15 and the following: (a) two (2) enclosed parking spaces shall be provided for each dwelling unit as shown on the plans identified as garage for each dwelling unit; (b) one (1) visitor parking spaces shall be provided as shown on the plans. Zoning Bylaw No. 2506 Page 165 5. General Drawings attached hereto prepared by Gerry Blonski, Architect, and on file with the City of White Rock as shown on the attached plans; and for the purposes of this zone are referred to as "the Plans". Development in this zone shall conform substantially to the Plans. Zoning Bylaw No. 2506 Page 166 The Plans Zoning Bylaw No. 2506 Page 167 Zoning Bylaw No. 2506 Page 168 Zoning Bylaw No. 2506 Page 169 Zoning Bylaw No. 2506 Page 170 Zoning Bylaw No. 2506 Page 171 Zoning Bylaw No. 2506 Page 172 7.29 CD-29 COMPREHENSIVE DEVELOPMENT ZONE (Marine & Oxford) INTENT The intent of this zone is to accommodate the development of a mixed commercial/residential complex on a site of approximately 0.4 ha. (0.99 ac) in the West Beach Waterfront Business Area. 5. Permitted Uses In the CD-29 Zone the following uses are permitted and all other uses are prohibited: (a) A retail service group 1 use (b) A multi-unit residential use in the form of apartment or townhouse (c) An accessory home occupation use subject to the provisions of section 5.3. 2. Location and Conditions of Permitted Uses The location of permitted uses shall be in accordance with the Plans and as follows: (a) A retail service group 1 use shall be located on the ground level fronting Marine Drive and Oxford Street as shown on the plans attached herein. (b) A townhouse use shall be located above the retail service group 1 uses and above the parking complex as shown on the plans herein. (c) An apartment use shall be located above the parking complex as shown on the plans attached herein. (d) A short term rental use shall be in accordance with the provisions of Section 5.3. 3. Number of Dwelling Units / Gross Floor Areas The maximum number of dwelling units and gross floor area of buildings and structures shall be in accordance with the following: (a) Maximum No. of dwelling units = sixty (60) (b) Maximum gross floor area of all uses = 7,298.75m2 (78,563ft2) (c) Maximum gross floor area of all residential uses = 6,617.75m2 (71,233ft2) (d) Maximum gross floor area of all commercial and storage uses exclusive of parking = 681m2 (7,330ft2) 3. Regulations for Height and Siting of Buildings and Structures Reference to a Building refers to the building labeled on the Plans. As indicated on the Plans, principal buildings are identified as Block 1, Block 2, Block 3 and Block 4: (a) Maximum geodetic height of buildings are as follows: (i) Maximum height of Block 1 ..........................= 14.40 metres (47.25 feet) (ii) Maximum height of Block 2 ..........................= 15.21 metres (49.83 feet) (iii) Maximum height of Block 3 ..........................= 13.35 metres (43.79 feet) (iv) Maximum height of Block 4 ..........................= 13.35 metres (43.79 feet) Zoning Bylaw No. 2506 Page 173 4. Parking and Loading Parking and Loading shall be provided in accordance with Sections 4.14 and 4.15, and as follows: (a) Ninety-six (96) parking spaces shall be provided to serve the residential townhouse and apartment units inclusive of one (1) parking space for disabled persons parking and which shall be clearly marked as per BC Building Code requirements. (b) Twenty (20) enclosed parking spaces shall be provided to serve the commercial uses and visitors parking (10 spaces for commercial use one (1) of which shall be provided for disabled persons parking and which shall be clearly marked as per BC Building Code requirements, and 10 spaces for visitor use); parking spaces shall be clearly marked as "commercial parking only" and as "visitors parking only". (c) Not more than 40% of the parking spaces shall be small car spaces, and they shall be clearly marked as "small car only". All as generally shown on the Plans. 5. General Drawings attached hereto prepared by Ankenman Marchand Architects, and on file with the City of White Rock as shown on the attached plans; and for the purposes of this zone are referred to as "the Plans". Development in this zone shall generally conform to the Plans. Zoning Bylaw No. 2506 Page 174 The Plans Zoning Bylaw No. 2506 Page 175 Site Plan 1 Zoning Bylaw No. 2506 Page 176 Parking Plan 1 Zoning Bylaw No. 2506 Page 177 Parking Plan 2 Zoning Bylaw No. 2506 Page 178 Elevations 1 Zoning Bylaw No. 2506 Page 179 7.30 CD-30 COMPREHENSIVE DEVELOPMENT ZONE (1424 Everall Street) INTENT The intent of this zone is to accommodate the development of a five (5) unit residential townhouse complex on a site of approximately 0.1 ha (0.24 ac) 1. Permitted Uses In the CD-30 Zone the following uses are permitted and all other uses are prohibited: (a) A multi-unit residential use in the form of a townhouse in one or more principal buildings on the lot. (b) An accessory home occupation use subject to the provisions of section 5.3. 2. Number of Dwelling Units / Gross Floor Areas / Lot Coverage The maximum number of dwelling units and lot coverage of buildings and structures shall be in accordance with the following: 1. Maximum No. of dwelling units = five (5) 2. Maximum Lot Coverage = 38.0% 3. Regulations for Size, Shape, and Siting of Buildings and Structures (a) Maximum height of buildings, and property line setbacks follows: (i) Maximum height of buildings = 10.5m (34.45ft) (ii) Setback from front (south) lot line = 2.94m (9.65ft) (iii) Setback from rear (north) lot line = 1.2m (3.94ft) (iv) Setback from interior (east) lot line = 7.0m (23.0ft) (v) Setback from exterior lot line (west) = 4.57m (15.0ft) (b) Maximum projections into the above property line setback requirements are outlined in Section 4.14 with the following exceptions: (i) a cantilevered floor area may extend not more than 0.3m into an interior side yard; (ii) an open porch or balcony may extend not more than 1.68m into a front or exterior side yard setback. (c) Subject to the provisions of Section 5.3, accessory buildings and structures: (i) shall not exceed a height of 4.0 m. 4. Parking and Loading shall be provided in accordance with Sections 4.14 and 4.15, with the following exceptions: (a) two (2) enclosed parking spaces shall be provided for each dwelling unit as shown on the plans identified as garage for each dwelling unit; and (b) one (1) visitor parking space shall be provided as shown on the plans. 5. Drawings attached hereto prepared by Gerry Blonski, Architect, and on file with the City of White Rock as shown on the attached plans; and for the purposes of this zone are referred to as "the Plans". Development in this zone shall conform substantially to the Plans. Zoning Bylaw No. 2506 Page 180 The Plans Zoning Bylaw No. 2506 Page 181 Zoning Bylaw No. 2506 Page 182 Zoning Bylaw No. 2506 Page 183 Zoning Bylaw No. 2506 Page 184 Zoning Bylaw No. 2506 Page 185 Zoning Bylaw No. 2506 Page 186 Zoning Bylaw No. 2506 Page 187 Zoning Bylaw No. 2506 Page 188 7.31 CD-31 COMPREHENSIVE DEVELOPMENT ZONE (1450 Vidal Street) INTENT The intent of this zone is to accommodate the development of a five (5) unit residential townhouse complex on a site of approximately 0.06 hectares (0.17 acres) 1. Permitted Uses: In the CD-31 Zone the following uses are permitted and all other uses are prohibited: (a) A multi-unit residential use in the form of a townhouse (b) An accessory home occupation use in accordance with the provisions of Section 5.3. 2. Number of Dwelling Units / Gross Floor Areas / Lot Coverage: The maximum number of dwelling units and lot coverage of buildings and structures shall be in accordance with the following: (a) Maximum No. of dwelling units = five (5) (b) Maximum Lot Coverage = 45.0% 3. Regulations for Size, Shape, and Siting of Buildings and Structures: Reference to a Building refers to the building labeled on the Plans. As indicated on the Plans, principal buildings are identified and labeled as Blocks A and B: (a) Maximum height of buildings, and property line setbacks shall be as follows: (i) Maximum height of buildings = 11.68 metres (38.33 feet) (ii) Setback from front (west) lot line = 6.1 metres (20 feet) (iii) Setback from rear (east) lot line = 6.1 metres (20 feet) (iv) Setback from interior (south) lot line = 1.5 metres (5 feet) (v) Setback from interior lot line (north) = 1.1 metres(3.75 feet) (b) Maximum projections into the above property line setback requirements shall be as outlined in Section 4.14, except that: (i) a cantilevered floor area may extend not more than 0.3 metres (1.0 feet) into an interior side yard; (ii) an open porch or balcony may extend not more than 1.68 metres (5.5 feet) into a front or exterior side yard. 4. Parking and Loading: Parking and Loading shall be provided in accordance with the requirements of Sections 4.14 and 4.15, and, additionally as follows: (a) two (2) enclosed parking spaces shall be provided for each dwelling unit as shown on the plans identified as garage for each dwelling unit; (b) one (1) open parking space shall be provided for each dwelling unit as shown on the plans. Zoning Bylaw No. 2506 Page 189 5. General: Drawings attached hereto prepared by Gerry Blonski, Architect, and on file with the City of White Rock as shown on the attached plans; and for the purposes of this zone are referred to as "the Plans". Development in this zone shall conform substantially to the Plans. Zoning Bylaw No. 2506 Page 190 The Plans Zoning Bylaw No. 2506 Page 191 Zoning Bylaw No. 2506 Page 192 Zoning Bylaw No. 2506 Page 193 Zoning Bylaw No. 2506 Page 194 7.32 CD-32 COMPREHENSIVE DEVELOPMENT ZONE (1455 - 65 Vidal Street) INTENT The intent of this zone is to accommodate the development of an eight (8) unit residential townhouse complex on a site of approximately 0.16 hectares (0.40 acres) 1. Permitted Uses: In the CD-32 Zone the following uses are permitted and all other uses are prohibited: (a) A multi-residential use in the form of a townhouse, in more than one principal building (b) An accessory home occupation use in accordance with the provisions of Section 5.2 2. Number of Dwelling Units / Gross Floor Areas / Lot Coverage: The maximum number of dwelling units and lot coverage of buildings and structures shall be in accordance with the following: (a) Maximum No. of dwelling units = eight (8) (b) Maximum Lot Coverage = 38.5% 3. Regulations for Size, Shape, and Siting of Buildings and Structures: Reference to a Building refers to the building as labeled on the Plans. As indicated on the Plans, principal buildings are identified as Building #1 and #2: (a) Maximum height of buildings, and property line setbacks are as follows: (i) Maximum height of building #1 = 11.5m (37.65ft) (ii) Maximum height of building #2 = 10.8m (35.4ft) (iii) Setback from front (east) lot line = 5.4m (17.83ft) (iv) Setback from rear (west) lot line = 2.7m (8.83ft) (v) Setback from interior (south) lot line = 6.1m (20.0ft) (vi) Setback from interior lot line (north) = 6.1m (20.0ft) (b) Maximum projections into the above property line setback requirements shall be as outlined in Section 4.14, with the following exceptions: (i) a cantilevered floor area may extend not more than 0.3 metres (1.0 feet) into an interior side yard. (ii) an open porch or balcony may extend not more than 1.68 metres (5.5 feet) into a front or interior side yard setback. 4. Parking and Loading shall be provided in accordance with Sections 4.14 and 4.15 and, additionally as follows: (a) two (2) enclosed parking spaces shall be provided for each dwelling unit as shown on the plans identified as garage for each dwelling unit; (b) two (2) visitor parking spaces shall be provided as shown on the plans. Zoning Bylaw No. 2506 Page 195 5. General: Drawings attached hereto prepared by Gerry Blonski, Architect, on file with the City of White Rock as shown on the attached plans, and for the purposes of this zone, are referred to as "the Plans". Development in this zone shall generally conform to the Plans. Zoning Bylaw No. 2506 Page 196 The Plans Zoning Bylaw No. 2506 Page 197 Zoning Bylaw No. 2506 Page 198 Zoning Bylaw No. 2506 Page 199 Zoning Bylaw No. 2506 Page 200 Zoning Bylaw No. 2506 Page 201 Zoning Bylaw No. 2506 Page 202 Zoning Bylaw No. 2506 Page 203 7.33 CD-33 COMPREHENSIVE DEVELOPMENT ZONE (application deferred) Zoning Bylaw No. 2506 Page 204 7.34 CD-34 COMPREHENSIVE DEVELOPMENT ZONE (1321 Fir Street) INTENT The intent of this zone is to accommodate the development of a four (4) unit residential townhouse complex on a site of approximately 0.07 hectares (0.17 acres) 1. Permitted Uses In the CD-34 Zone the following uses are permitted and all other uses are prohibited: (a) A multi-unit residential use in the form of a townhouse in one or more principal buildings on the lot. (b) An accessory home occupation use subject to the provisions of section 5.3. 2. Number of Dwelling Units / Lot Coverage The maximum number of dwelling units and lot coverage of buildings and structures shall be in accordance with the following: (a) Maximum No. of dwelling units = four (4) (b) Maximum Lot Coverage = 38% 3. Regulations for Size, Shape, and Siting of Buildings and Structures Reference to a Building refers to the building as labeled on the Plans. As indicated, principal buildings are identified as Buildings A and B: (a) Maximum height of buildings, and property line setbacks follows: (i) Maximum height of building A = 11.54 metres (37.86 feet) (ii) Maximum height of building B = 11.61 metres (38.09 feet) (iii) Setback from front lot line = 4.45 metres (14.5 feet) (iv) Setback from rear lot line = 3.5 metres (11.5 feet) (v) Setback from interior lot line = 1.5 metres (5 feet) (vi) Setback from interior lot line = 1.5 metres (5 feet) 4. Parking and Loading Parking and Loading shall be provided in accordance with the following in addition to the requirements of Sections 4.14 and 4.15: (a) two (2) enclosed parking spaces shall be provided for each dwelling unit as shown on the plans identified as garage for each dwelling unit; (b) one (1) visitor parking space shall be provided as shown on the plans. 5. General Drawings attached hereto prepared by Gerry Blonski, Architect, and on file with the City of White Rock as shown on the attached plans; and for the purposes of this zone are referred to as "the Plans". Development in this zone shall generally conform to the Plans. Zoning Bylaw No. 2506 Page 205 The Plans Zoning Bylaw No. 2506 Page 206 Zoning Bylaw No. 2506 Page 207 Zoning Bylaw No. 2506 Page 208 Zoning Bylaw No. 2506 Page 209 Zoning Bylaw No. 2506 Page 210 7.35 CD-35 COMPREHENSIVE DEVELOPMENT ZONE (15118 Thrift Avenue) INTENT The intent of this zone is to accommodate the development of a five (5) unit residential townhouse complex on a site of approximately 0.06 hectares (0.15 acres) 1. Permitted Uses: In the CD-35 Zone the following uses are permitted and all other uses are prohibited: (a) A multi-unit residential use in the form of a townhouse in one or more principal buildings on the lot. (b) An accessory home occupation use subject to the provisions of Section 5.3. 2. Number of Dwelling Units / Lot Coverage: The maximum number of dwelling units and lot coverage of buildings and structures shall be in accordance with the following: (a) Maximum No. of dwelling units = five (5) (b) Maximum Lot Coverage = 48.5% 3. Regulations for Size, Shape, and Siting of Buildings and Structures: Reference to a Building refers to the building labeled that on the Plans: (a) Maximum height of buildings, and minimum setbacks from property lines are as follows: (i) Maximum height of building = 9.95m (32.3ft) (ii) Setback from the front lot line = 4.51m (14.8ft) (iii) Setback from the rear lot line = 3.56m (11.7ft) (iv) Setback from the west interior lot line = 4.57m (15.0ft) (v) Setback from the east interior lot line = 1.27m (4.2ft) (b) Maximum projections into the above property line setback requirements shall be as outlined in Section 4.14 except as otherwise authorized or required below: (i) an open porch may extend not more than 1.54m (5.1ft) into a front yard setback. (ii) A set of stairs may extend not more than 3.82m (12.5ft) into a front yard setback. (iii) an open balcony may extend not more than 0.55m (1.8ft) into a front or side yard setback. (iv) A canopy may extend not more than 0.91m (3.0ft) into a front or side yard setback. 4. Parking and Loading: Parking and Loading shall be provided in accordance with the provisions of Sections 4.14 and 4.15, except as otherwise authorized or required below: (a) one (1) enclosed parking space shall be provided for each dwelling unit as shown on the plans identified as garage for each dwelling unit; Zoning Bylaw No. 2506 Page 211 (b) one (1) parking space shall be provided for each dwelling unit as shown on the plans identified as driveway for each dwelling unit; and (c) one (1) visitor parking space shall be provided as shown on the plans. 5. General: Drawings attached hereto prepared by Barnett Dembek Architects Inc. and on file with the City of White Rock as shown on the attached plans and for the purposes of this zone are referred to as "the Plans". Development in this zone shall generally conform to the Plans. Zoning Bylaw No. 2506 Page 212 The Plans Zoning Bylaw No. 2506 Page 213 Zoning Bylaw No. 2506 Page 214 Zoning Bylaw No. 2506 Page 215 Zoning Bylaw No. 2506 Page 216 7.36 CD-36 COMPREHENSIVE DEVELOPMENT ZONE (15577 - 85 Marine Drive) INTENT The intent of this zone is to accommodate the development of ten (10) unit apartment and one unit commercial complex on a site of approximately 0.05 hectares (0.13 acres) 1. Permitted Uses In the CD-36 Zone the following uses are permitted and all other uses are prohibited: (a) A retail service group 1 use (b) An apartment use (c) An accessory home occupation use 2. Location of Permitted Uses The location of permitted use shall be in accordance with the Plans and as follows: (a) A retail service group 1 use shall be limited to the first and second storeys of a building; (b) An apartment use as subject to Section 403(6) shall be limited exclusively to the storey or storeys above the first storey of a building and above the highest storey in the building which is used for a retail service group 1 use; and (c) An accessory home occupation use shall comply with the provisions of Section 3. Number of Dwelling Units / Gross Floor Areas / Lot Coverage The maximum number of dwelling units and lot coverage of buildings and structures shall be in accordance with the following: (a) Maximum No. of dwelling units = ten (10) (b) Maximum Lot Coverage = 96.8% 4. Regulations for Size, Shape, and Siting of Buildings and Structures Reference to a Building refers to the building labelled that specific number on the Plans. As indicated on the Plans, principal buildings are identified as Building #1, #2, #3, and #4: (a) Maximum height of buildings, and property line setbacks follows: (i) Maximum height = 16.3 metres (53.48 feet) geodetic (ii) Setback from front (south) lot line = 0.0 metres (0.0 feet) (iii) Setback from rear (north) lot line = 0.305 metres (1.0 feet) (iv) Setback from interior (east) lot line = 0.0 metres (0.0 feet) (v) Setback from interior (west) lot line = 0.0 metres (0.0 feet) 5. Parking and Loading Parking and Loading shall be provided in accordance with Section 402 and additionally as follows: (a) one (1) enclosed parking space for a total of ten (10), including one (1) handicap parking space shall be provided for each dwelling unit as shown on the plans; and (b) One (1) commercial parking will be provided, as shown in the plans. Zoning Bylaw No. 2506 Page 217 6. General Drawings attached hereto prepared by David Danyluck Architect and on file with the City of White Rock as shown on the attached plans; and for the purposes of this zone are referred to as "the Plans". Development in this zone shall generally conform to the Plans. Zoning Bylaw No. 2506 Page 218 The Plans Zoning Bylaw No. 2506 Page 219 Site Plan Zoning Bylaw No. 2506 Page 220 Floor Plans Zoning Bylaw No. 2506 Page 221 Zoning Bylaw No. 2506 Page 222 Zoning Bylaw No. 2506 Page 223 Zoning Bylaw No. 2506 Page 224 7.37 CD-37 COMPREHENSIVE DEVELOPMENT ZONE (application deferred) Zoning Bylaw No. 2506 Page 225 7.38 CD-38 COMPREHENSIVE DEVELOPMENT ZONE (open for use) Zoning Bylaw No. 2506 Page 226 7.40 CD-40 COMPREHENSIVE DEVELOPMENT ZONE (1330 - 46 Foster Street) INTENT The intent of this zone is to accommodate the development of a fourteen (14) unit residential townhouse complex on a site of approximately 0.18 hectares (0.44 acres) 1. Permitted Uses: In the CD-40 Zone the following uses are permitted and all other uses are prohibited: (a) A multi-unit residential use in the form of a townhouse in one or more principal buildings (b) An accessory home occupation use subject to the provisions of section 5.3 2. Number of Dwelling Units / Gross Floor Areas / Lot Coverage: The maximum number of dwelling units and lot coverage of buildings and structures shall be in accordance with the following: (a) Maximum No. of dwelling units = fourteen (14) (b) Maximum Lot Coverage = 47.5% 3. Regulations for Size, Shape, and Siting of Buildings and Structures: Reference to a Building refers to the building labeled that specific number on the Plans. As indicated on the Plans, principal buildings are identified as Building #1 and #2: (a) Maximum height of buildings (from average natural grade), and property line setbacks follows: (i) Maximum height of building #1 = 10.07m (33.04ft) (ii) Maximum height of building #2 = 12.66m (41.58ft) (iii) Setback from front (west) lot line = 6.0m (19.6ft) (iv) Setback from rear (east) lot line = 5.8m (19.0ft) (v) Setback from interior (north) lot line = 3.43m (11.3ft) (vi) Setback from interior (south) lot line = 2.13m (7.0ft) (b) Maximum projections into the above property line setback requirements be as outlined in the attached drawings in addition to sub-section 4.14, including: (i) An open deck or balcony which may extend not more than 2.1 metres (6.9 feet) into a front or rear yard setback. 4. Parking and Loading: Parking and Loading shall be provided in accordance with the following in addition to the provisions of Sections 4.14 and 4.15: (a) two (2) enclosed parking spaces shall be provided for each dwelling unit as shown on the plans identified as garage for each dwelling unit; (b) additional visitor parking spaces shall be provided in the driveways as shown on the plans. Zoning Bylaw No. 2506 Page 227 5. Drawings: Drawings attached hereto prepared by Gerry Blonski, Architect, and on file with the City of White Rock as shown on the attached plans, and for the purposes of this zone are referred to as "the Plans". Development in this zone shall generally conform to the Plans. Zoning Bylaw No. 2506 Page 228 The Plans Zoning Bylaw No. 2506 Page 229 Zoning Bylaw No. 2506 Page 230 7.41 CD-41 COMPREHENSIVE DEVELOPMENT ZONE (1467 - 1519 Vidal Street) INTENT The intent of this zone is to accommodate the development of a 109 unit, 12-storey multi-unit residential complex on a site of approximately 0.4848 ha (1.198 ac) on Vidal Street. 1. Permitted Uses In the CD-41 Zone the following uses are permitted and all other uses are prohibited: (a) A multi-unit residential use in the form of apartment or townhouse (b) An accessory home occupation use subject to the provisions of section 5.3. 2. Number of Dwelling Units / Gross Floor Areas The maximum number of dwelling units and gross floor area of buildings and structures shall be in accordance with the following: (a) Maximum number of dwelling units = one hundred and nine (109) (b) Maximum number of townhouse units = twelve (12) (c) Maximum number of apartment units = ninety-seven (97) (d) Maximum residential floor area = 11,037.8m2 (118,810ft2) (e) Maximum gross floor area = 13,750m2 (148,000ft2) 3. Regulations for Height and Siting of Buildings and Structures Maximum building height = 37.04m (121.52ft) measured to a maximum height of 141.35m (463.75ft) geodetic up from a starting point of 104.31m (342.2ft) geodetic elevation. 4. Parking and Loading Parking and Loading shall be provided in accordance with Sections 4.14 and 4.15, with a total minimum of one hundred and seventy-one (171) parking spaces to be provided as follows: (a) Twenty-four (24) parking spaces shall be provided to serve the 12 townhouse units at a ratio of 2 spaces per townhouse unit; (b) One hundred and sixteen (116) parking spaces shall be provided to serve the 97 apartment units; (c) Not more than 40% of the parking spaces shall be small car spaces, and they shall be clearly marked as "small car only". (d) Twenty-nine (29) visitor parking spaces shall be provided to the residential complex and they shall be clearly marked as "visitor parking". (e) A minimum of two (2) parking spaces shall be provided for disabled persons parking and shall be clearly marked as per BC Building Code requirements. (f) A minimum of one (1) on-site loading space shall be provided. 5. General Zoning Bylaw No. 2506 Page 231 Drawings attached hereto and on file with the City of White Rock as shown on the attached plans and for the purposes of this zone are referred to as "the Plans". Development in this zone shall generally conform to the Plans. Zoning Bylaw No. 2506 Page 232 The Plans Zoning Bylaw No. 2506 Page 233 Zoning Bylaw No. 2506 Page 234 Zoning Bylaw No. 2506 Page 235 Zoning Bylaw No. 2506 Page 236 Zoning Bylaw No. 2506 Page 237 Zoning Bylaw No. 2506 Page 238 Zoning Bylaw No. 2506 Page 239 Zoning Bylaw No. 2506 Page 240 Zoning Bylaw No. 2506 Page 241 7.46 CD-46 COMPREHENSIVE DEVELOPMENT ZONE (1500 Oxford Street) INTENT The intent of this zone is to accommodate a 121-unit residential development on a site of approximately 7,090 square metres (1.75 acres) in area. 1. Permitted Uses: (a) multi-unit residential use (b) accessory home occupation use in accordance with the provisions of 5.3 and that does not involve clients directly accessing the building 2. Lot Coverage: (a) Maximum lot coverage shall not exceed 36% 3. Density: (a) Maximum gross floor area shall not exceed 32,522 square metres (350,060ft2) (b) Maximum residential floor area shall not exceed 27,607 square metres (297,156ft2) (c) Maximum number of dwelling units shall not exceed 121 4. Building Height: (d) Tower A (shown on attached Plans) shall not exceed a height of 159.5 metres geodetic (e) Tower B (shown on attached Plans) shall not exceed a height of 170.5 metres geodetic (f) Section 4.13.4 does not apply to the CD-46 Zone 5. Siting Requirements: (a) Minimum setbacks are as follows: (i) Setback for buildings from front (west) lot line = 14.8 metres (ii) Setback for balconies from front (west) lot line = 11.8 metres (iii) Setback for buildings from rear (east) lot line = 19.5 metres (iv) Setback for buildings from north interior side lot line = 6.1 metres (v) Setback for slab extensions from north interior side lot line = 3.9 metres (vi) Setback for buildings from south interior side lot line = 4.3 metres (vii) Setback for balconies from south interior side lot line = 1.2 metres (viii) Setback for buildings from other interior side lot lines = 3.0 metres (ix) Setback for slab extensions from other interior side lot lines = 0.3 metres (b) Stair accesses to the underground parking shall be sited as shown on the attached Plans 6. Parking: Parking shall be provided in accordance with Section 4.14, with a total minimum of four hundred (400) parking spaces to be provided as follows: (d) A minimum of forty (40) visitor spaces are to be provided and marked as 'visitor parking' (e) A minimum of three hundred and sixty (360) spaces shall be provided to serve the residential units Zoning Bylaw No. 2506 Page 242 (f) A minimum of six (6) spaces shall be provided for disabled persons parking and shall be clearly marked as per BC Building Code requirements 7. Loading: (a) Two (2) loading zones shall be provided in accordance with Section 4.15 8. Bicycle Parking: (a) A minimum of one hundred and twenty-two (122) Class I bicycle parking spaces shall be provided, in accordance with Section 4.16 (b) A minimum of twenty-five (25) Class II bicycle parking spaces shall be provided, in accordance with Section 4.16 9. General: (a) Development in this zone shall substantially conform to the Plans prepared by Chris Dikeakos Architects Inc. and dated October 27, 2015, that are attached hereto and on file at the City of White Rock Zoning Bylaw No. 2506 Page 243 Zoning Bylaw No. 2506 Page 244 Zoning Bylaw No. 2506 Page 245 Zoning Bylaw No. 2506 Page 246 Zoning Bylaw No. 2506 Page 247 Zoning Bylaw No. 2506 Page 248 Zoning Bylaw No. 2506 Page 249 7.48 CD-48 COMPREHENSIVE DEVELOPMENT ZONE (15611 Marine Drive) INTENT The intent of this zone is to accommodate a hotel with 39 suites above a lounge area on a site of approximately 5,567 square metres in area. 1. Permitted Uses: (a) hotel (b) licenced establishments, including liquor primary, food primary, agent store, u-brew and u-vin (c) retail service group 1 uses; 2. Lot Coverage: (a) Maximum lot coverage shall not exceed 93% 3. Density: (d) Maximum gross floor area shall not exceed 5,567 square metres (59,922 square feet) 4. Building Height: (g) Principal buildings shall not exceed a height of 19.1 metres geodetic 5. Siting Requirements: (c) Minimum setbacks are as follows: (i) Setback from front (north) lot line = 1.8 metres (ii) Setback from rear (south) lot line = 0.0 metres (iii) Setback from exterior (west) side lot line = 1.5 metres (iv) Setback from interior (east) side lot lines = 0.9 metres (d) Notwithstanding the above, balconies and roof overhangs may extend to within 0.9 metres of an exterior (west) side lot line. 6. Parking: (a) A minimum of 57 parking spaces shall be provided 7. General: (a) Development in this zone shall conform to the Plans (last revision date August 15, 2014) prepared by Paul Rust, Architect, that are attached hereto and on file at the City of White Rock Zoning Bylaw No. 2506 Page 250 Zoning Bylaw No. 2506 Page 251 Zoning Bylaw No. 2506 Page 252 Zoning Bylaw No. 2506 Page 253 7.51 CD-51 COMPREHENSIVE DEVELOPMENT ZONE (14825 & 14835 Thrift Avenue) INTENT The intent of this zone is to accommodate the development of a multi-unit residential development on a site of approximately 2,023.7 square metres in area. 1. Permitted Uses: (a) multi-unit residential use (b) accessory home occupation use in accordance with the provisions of 5.3 and that does not involve clients directly accessing the building 2. Lot Coverage: (e) Maximum lot coverage shall not exceed 38% 3. Density: Maximum gross floor area shall not exceed 5,671.3 square metres (61,045.1 ft2), maximum residential floor area shall not exceed 4,431.3 square metres (46,729.5ft2), and the maximum number of dwelling units shall not exceed 25, comprised as follows: (a) BASE DENSITY: The maximum gross floor area shall not exceed 0.9 times the lot area, and the maximum number of dwelling units shall not exceed 12 units. (b) ADDITIONAL (BONUS) DENSITY: Where a contribution of $350,000 has been provided to the Community Amenity Reserve Fund to assist with the provision of the amenities in the following table, the maximum gross floor area shall not exceed 5,671.3 square metres (61,045.1 ft2), the maximum residential floor area shall not exceed 4,431.3 square metres (46,729.5ft2), and the maximum number of dwelling units shall not exceed 25 units. # Amenity 1 New public open space and walkways 2 Improvement of existing open space and walkways 3 Public art 4 Waterfront improvement, including civic parking facilities 5 Special needs or non-market affordable housing 6 People movement infrastructure to link Uptown to the Waterfront The amenity must be provided in accordance with an amenity agreement and section 219 covenant delivered by the owner of the subject real property, to secure the amenity. 4. Building Height: (a) The building shall not exceed 118.6 metres geodetic, inclusive of the stair tower and elevator shaft. Zoning Bylaw No. 2506 Page 254 5. Siting Requirements: (a) Minimum setbacks are as follows: (i) Setback from front (south) lot line = 12.95 metres (ii) Setback from rear (north) lot line = 6.71 metres (iii) Setback from interior side (east) lot line = 7.15 metres (iv) Setback from interior side (west) lot line = 6.16 metres (b) Notwithstanding the above, balconies and canopies may encroach by up to 2.99 metres into the required front (south) lot line setback, and balconies may encroach by up to 2.14 metres into the required rear (north) lot line setback. 6. Parking: Parking shall be provided in accordance with Section 4.14, with a minimum total of sixty (60) parking spaces to be provided as follows: (a) A minimum of fifty (52) spaces shall be provided to serve the residential units, including a minimum of one (1) space for disabled persons clearly marked as per BC Building Code requirements (b) A minimum of eight (8) visitor spaces are to be provided and marked as 'visitor,' including a minimum of one (1) space for disabled persons clearly marked as per BC Building Code requirements 7. Loading: (a) One (1) loading zone shall be provided in accordance with Section 4.15 8. Bicycle Parking: (a) A minimum of twenty-five (25) Class I bicycle parking spaces shall be provided, in accordance with Section 4.16 (b) A minimum of five (5) Class II bicycle parking spaces shall be provided, in accordance with Section 4.16 9. General: (a) Development in this zone that includes the additional (bonus) density referred to in Subsection 3(b) shall substantially conform to the elevations prepared by Ankenman Associates Architects Inc. dated February 7, 2017 and the site plan prepared by Ankenman Associates Architects Inc. dated February 7, 2017, that are attached hereto and on file at the City of White Rock. (b) Development in this zone that does not include the additional (bonus) density referred to in Sub-section 3(b) shall be required to obtain a new Major Development Permit. Zoning Bylaw No. 2506 Page 255 Zoning Bylaw No. 2506 Page 256 Zoning Bylaw No. 2506 Page 257 Zoning Bylaw No. 2506 Page 258 7.54 CD-54 COMPREHENSIVE DEVELOPMENT ZONE (Best & Roper) INTENT The intent of this zone is to accommodate the development of a multi-unit residential development on a site of approximately 1,887 square metres in area. 1. Permitted Uses: (a) multi-unit residential use (b) accessory home occupation use in accordance with the provisions of 5.3 and that does not involve clients directly accessing the building 2. Lot Coverage: (a) Maximum lot coverage shall not exceed 53%. 3. Density: Maximum residential floor area shall not exceed 1.5 times the lot area, and the maximum number of dwelling units shall not exceed 28, comprised as follows: (a) BASE DENSITY: The maximum residential floor area shall not exceed 1.1 times the lot area, and the maximum number of dwelling units shall not exceed 23 units. (b) ADDITIONAL (BONUS) DENSITY: Where a contribution of $712,063 has been provided to the Community Amenity Reserve Fund to assist with the provision of the amenities in the following table, the maximum residential floor area shall not exceed 1.5 times the lot area, and the maximum number of dwelling units shall not exceed 28 units. # Amenity 1 New public open space and walkways 2 Improvement of existing open space and walkways 3 Public art 4 Waterfront improvement, including civic parking facilities 5 Special needs or non-market affordable housing 6 People movement infrastructure to link Uptown to the Waterfront The amenity must be provided in accordance with an amenity agreement and section 219 covenant delivered by the owner of the subject real property, to secure the amenity. 4. Building Height: (a) The building shall not exceed 106.6 metres geodetic Zoning Bylaw No. 2506 Page 259 5. Siting Requirements: (a) Minimum setbacks are as follows: (i) Setback from front (east) lot line = 6.01 metres (ii) Setback from rear (west) lot line = 6.0 metres (iii) Setback from exterior side (north) lot line = 6.0 metres (iv) Setback from interior side (south) lot line = 5.7 metres (b) Notwithstanding the above, balconies may encroach by up to 1.17 metres into the required rear (west) lot line setback, a bay window may encroach by up to 0.5 metres into the required interior (south) lot line setback, balconies may encroach by up to 1.17 metres into the required front (east) lot line setback, and entrance canopies may encroach by up to 3.05 metres into the required front (east) lot line setback. 6. Parking: Parking shall be provided in accordance with Section 4.14, with a minimum 1.5 parking spaces per dwelling unit to be provided as follows: (a) A minimum of 1.2 spaces per dwelling unit shall be provided to serve the residential units (b) A minimum of 0.3 spaces per dwelling unit are to be provided and marked as 'visitor' (c) A minimum of three (3) spaces shall be provided for disabled persons parking and shall be clearly marked as per BC Building Code requirements 7. Loading: (a) One (1) loading zone shall be provided in accordance with Section 4.15 8. General: (a) Development in this zone that includes the additional (bonus) density referred to in Sub-section 3(b) shall substantially conform to the Plans prepared by Gerry Blonski Architect and dated "August 27, 2016 Revised", that are attached hereto and on file at the City of White Rock (b) Development in this zone that does not include the additional (bonus) density referred to in Sub-section 3(b) shall be required to obtain a Major Development Permit. Zoning Bylaw No. 2506 Page 260 Zoning Bylaw No. 2506 Page 261 Zoning Bylaw No. 2506 Page 262 Zoning Bylaw No. 2506 Page 263 7.56 CD-56 COMPREHENSIVE DEVELOPMENT ZONE (Nichol & North Bluff) INTENT The intent of this zone is to accommodate the development of a multi-unit residential development with a commercial component on a site of approximately 2,660 square metres in area. 1. Permitted Uses: (a) multi-unit residential use (b) retail service group 1 use (c) accessory home occupation use in accordance with the provisions of 5.3 and that does not involve clients directly accessing the building 2. Location of Permitted Uses: (a) a retail service group 1use shall be located on the ground level in the portion of the building fronting on Nichol Road. (b) a multi-unit residential use shall be located in all parts of the building other than the ground level fronting on Nichol Road. (c) an accessory home occupation use may be located within a dwelling unit. 3. Lot Coverage: (a) lot coverage shall not exceed 60%. 4. Density: Maximum gross floor area shall not exceed 2.18 times the lot area, and the maximum number of dwelling units shall not exceed 51, comprised as follows: (a) BASE DENSITY: The maximum gross floor area shall not exceed 1.75 times the lot area, and the maximum number of dwelling units shall not exceed 33 units. (b) ADDITIONAL (BONUS) DENSITY: Where a contribution of $200,000 has been provided to the Community Amenity Reserve Fund to assist with the provision of the amenities in the following table, the maximum gross floor area shall not exceed 2.18 times the lot area, and the maximum number of dwelling units shall not exceed 51 units. # Amenity 1 New public open space and walkways 2 Improvement of existing open space and walkways 3 Public art 4 Waterfront improvement, including civic parking facilities 5 Special needs or non-market affordable housing 6 People movement infrastructure to link Uptown to the Waterfront Zoning Bylaw No. 2506 Page 264 The amenity must be provided in accordance with an amenity agreement and section 219 covenant delivered by the owner of the subject real property, to secure the amenity. 5. Building Height: (a) The building shall not exceed 100.5 metres geodetic 6. Siting Requirements: (a) Minimum setbacks are as follows: (i) Setback from front (west) lot line = 3.68 metres (ii) Setback from rear (east) lot line = 3.91 metres (iii) Setback from exterior side (north) lot line = 2.13 metres (iv) Setback from interior side (south) lot line = 2.33 metres (b) Notwithstanding the above, balconies/overhangs may encroach by up to 2.17 metres into the required front (west) lot line setback, 1.07 metres into the required rear (east) lot line setback, 2.13 metres into the required exterior side (north) lot line setback, and 1.67 metres into the required interior side (south) lot line setback. (c) Notwithstanding the above, columns may encroach by up to 0.81 metres into the required front (west) lot line setback, 0.61 metres into the required rear (east) lot line setback, and 0.61 metres into the required exterior side (north) lot line setback. 7. Parking: Parking shall be provided in accordance with Section 4.14, with the minimum number of spaces required as follows: (a) A minimum of 86 spaces shall be provided for the residential units (b) A minimum of 15 spaces shall be provided for visitors and marked as 'visitor' (c) A minimum of six (6) spaces shall be provided for use by the commercial tenants and marked as 'commercial' (d) A minimum of two (2) spaces shall be provided for disabled persons parking and shall be clearly marked as per BC Building Code requirements 8. Bicycle Parking: Bicycle parking shall be provided in accordance with Section 4.16, with the minimum number of spaces required as follows: (a) A minimum of 55 Class I spaces shall be provided (b) A minimum of 10 Class II spaces shall be provided 9. Loading: Loading shall be provided in accordance with Section 4.15, with the minimum number of loading spaces required as follows: (a) One (1) loading zone shall be provided for residential use in accordance with Section 4.15 (b) One (1) loading zone shall be provided for commercial use in accordance with Section 4.15 Zoning Bylaw No. 2506 Page 265 10. General: (a) Development in this zone that includes the additional (bonus) density referred to in Subsection 4(b) shall substantially conform to the Plans prepared by Integra Architecture Inc. dated October 4, 2016, that are attached hereto and on file at the City of White Rock. (b) Development in this zone that does not include the additional (bonus) density referred to in Sub-section 4(b) shall be required to obtain a new Major Development Permit. Zoning Bylaw No. 2506 Page 266 Zoning Bylaw No. 2506 Page 267 Zoning Bylaw No. 2506 Page 268 Zoning Bylaw No. 2506 Page 269 7.57 CD-57 COMPREHENSIVE DEVELOPMENT ZONE (Finlay/Russell) INTENT The intent of this zone is to accommodate the development of a mixed-use development on a site of approximately 5,290.4 square metres (1.3 acres) in area. 1. Permitted Uses: (a) multi-unit residential use (b) retail service group 1 use (c) medical or dental clinic (d) child care centre use in accordance with the provisions of section 5.1.1 (e) accessory home occupation use in accordance with the provisions of section 5.3 and that does not involve clients directly accessing the principal building 2. Location of Permitted Uses: (a) retail service group 1 uses, medical or dental clinics, and child care centre uses shall be located on the first or second storey of the principal building (b) multi-unit residential uses shall be located above the first two storeys of the principal building (c) an accessory home occupation use may be located within a dwelling unit. 3. Lot Coverage: (a) lot coverage shall not exceed 82% 4. Density: (a) Maximum gross floor area shall not exceed 24,145 square metres, and the maximum number of dwelling units shall not exceed 126, comprised as follows: (i) BASE DENSITY: The maximum gross floor area shall not exceed 9,822 square metres, and the maximum number of dwelling units shall not exceed 57 units (ii) ADDITIONAL (BONUS) DENSITY: Where a contribution of $2,210,000 has been provided to the Community Amenity Reserve Fund to assist with the provision of the amenities in the following table, and a housing agreement has been entered into and filed with the Land Title Office on the subject real property to secure sixteen (16) units with a minimum aggregate 1,363.6 square metres (14,678 square feet) residential floor area as rental tenure for the life of the building, the maximum gross floor area shall not exceed 24,145 square metres, and the maximum number of dwelling units shall not exceed 126 units # Amenity 1 New public open space and walkways Zoning Bylaw No. 2506 Page 270 2 Improvement of existing open space and walkways 3 Public art 4 Waterfront improvement, including civic parking facilities 5 Special needs or non-market affordable housing 6 People movement infrastructure to link Uptown to the Waterfront The amenity must be provided in accordance with an amenity agreement and a section 219 covenant delivered by the owner of the subject real property to secure the amenity 5. Building Height: (a) The principal building shall not exceed 143.9 metres geodetic 6. Siting Requirements: (a) Minimum setbacks are as follows: (i) Setback from front (south) lot line = 3.04 metres (ii) Setback from rear (north) lot line = 0.00 metres (iii) Setback from exterior side (west) lot line = 1.85 metres (iv) Setback from interior side (east) lot line = 6.09 metres (b) Notwithstanding the above, balconies may encroach by up to 2.57 metres into the required front (south) lot line setback and 1.15 metres into the required interior side (east) lot line setback 7. Parking: Parking shall be provided in accordance with Section 4.14, with the minimum total number of 349 spaces required as follows: (a) A minimum of 179 spaces shall be provided for the residential dwelling units (b) A minimum of 40 spaces shall be provided for visitors and marked as 'visitor' (c) A minimum of 130 spaces shall be provided for the retail service group 1 uses, medical or dental clinic and the child care centre uses (d) A minimum of eight (8) of the required 349 spaces shall be provided for disabled persons parking and shall be clearly marked in accordance with B.C. Building Code requirements (e) Where a child care centre use is operating on the property, a minimum of two (2) of the required 349 spaces shall be provided for child care centre use on the ground floor level and shall be clearly marked 8. Bicycle Parking: Bicycle parking shall be provided in accordance with Section 4.16, with the minimum number of spaces required as follows: (a) A minimum of 91 Class I spaces shall be provided (b) A minimum of 19 Class II spaces shall be provided 9. Loading: Zoning Bylaw No. 2506 Page 271 (a) One (1) loading zone shall be provided for residential use and three (3) loading zones shall be required for commercial use in accordance with Section 4.15 10. General: (a) Development in this zone that includes the additional (bonus) density referred to in Section 4 shall substantially conform to the Plans prepared by Chris Dikeakos Architects Inc. dated January 25, 2017 that are attached hereto and on file at the City of White Rock (b) Development in this zone that does not include the additional (bonus) density referred to in Section 3 shall be required to obtain a new Major Development Permit Zoning Bylaw No. 2506 Page 272 Zoning Bylaw No. 2506 Page 273 Zoning Bylaw No. 2506 Page 274 Zoning Bylaw No. 2506 Page 275 Zoning Bylaw No. 2506 Page 276 Zoning Bylaw No. 2506 Page 277 7.58 CD-58 COMPREHENSIVE DEVELOPMENT ZONE (1350 Johnston Road) INTENT The intent of this zone is to accommodate the development of a mixed-use development on a site of approximately 3,003.7 square metres (0.74 acres) in area. 1. Permitted Uses: (a) multi-unit residential use (b) retail service group 1 use (c) licensed establishments, including liquor primary, food primary, agent store, u-brew and u-vin (d) medical or dental clinic (e) accessory home occupation use in accordance with the provisions of section 5.3 and that does not involve clients directly accessing the principal building 2. Lot Coverage: (a) lot coverage shall not exceed 89.5% 3. Density: Maximum gross floor area shall not exceed 14,409.81 square metres, with a minimum commercial floor area of 917.3 square metres, and the maximum number of dwelling units shall not exceed 97, comprised as follows: (a) BASE DENSITY: The maximum gross floor area shall not exceed 5,256.5 square metres, and the maximum number of dwelling units shall not exceed 35 units (b) ADDITIONAL (BONUS) DENSITY: Where a contribution of $2,880,000 has been provided to the Community Amenity Reserve Fund to assist with the provision of the amenities in the following table, the maximum gross floor area shall not exceed 14,409.81 square metres, with a minimum of 917.3 square metres of commercial floor area, and the maximum number of dwelling units shall not exceed 97 units # Amenity 1 New public open space and walkways 2 Improvement of existing open space and walkways 3 Public art 4 Waterfront improvement, including civic parking facilities 5 Special needs or non-market affordable housing 6 People movement infrastructure to link Uptown to the Waterfront The amenity must be provided in accordance with an amenity agreement and a section 219 covenant delivered by the owner of the subject real property to secure the amenity Zoning Bylaw No. 2506 Page 278 4. Building Height: (a) The principal building shall not exceed 145.75 metres geodetic (b) The principal building shall not exceed 12 storeys. 5. Siting Requirements: (a) Minimum setbacks are as follows: (i) Setback from front (west) lot line = 3.3 metres (ii) Setback from rear (east) lot line = 0.0 metres (iii) Setback from interior side (north) lot line = 0.0 metres (iv) Setback from interior side (south) lot line = 0.0 metres (b) Notwithstanding the above, the required front (west) lot line setback may be reduced to 0.6 metres for balconies, attached and detached canopies, trellises, and overhangs 6. Ancillary Buildings and Structures: (a) One detached, unenclosed canopy structure with a maximum height of 3.5 metres is permitted in the front yard 7. Parking: Parking shall be provided in accordance with Section 4.14, with the minimum total number of 247 spaces required as follows: (a) A minimum of 181 spaces shall be provided for the residential dwelling units (b) A minimum of 29 spaces shall be provided for visitors to the residential dwelling units and marked as 'visitor' (c) A minimum of 37 spaces shall be provided for the retail service group 1 uses, licensed establishments and medical or dental clinic uses (d) A minimum of 5 of the required 247 spaces shall be provided for disabled persons parking and shall be clearly marked in accordance with B.C. Building Code requirements 8. Bicycle Parking: Bicycle parking shall be provided in accordance with Section 4.16, with the minimum number of spaces required as follows: (a) A minimum of 133 Class I spaces shall be provided (b) A minimum of 31 Class II spaces shall be provided 9. Loading: (a) A total of 3 loading zones shall be provided for residential and commercial uses in accordance with Section 4.15 10. General: Zoning Bylaw No. 2506 Page 279 (a) Development in this zone that includes the additional (bonus) density referred to in Section 3 shall substantially conform to the Plans prepared by Rafii Architects Inc. dated July 12, 2017 that are attached hereto and on file at the City of White Rock (b) Notwithstanding (a), the building height of the principal building in this zone that includes the additional (bonus) density referred to in Section 3 shall be limited to the maximum geodetic height noted in section 4 (a) of this zone and as shown on the attached Plans, and the number of storeys in the principal building shall be limited to a maximum of 12. (c) A new Major Development Permit shall be required for development in this zone that does not include the additional (bonus) density referred to in Section 3. Zoning Bylaw No. 2506 Page 280 Zoning Bylaw No. 2506 Page 281 Zoning Bylaw No. 2506 Page 282 Zoning Bylaw No. 2506 Page 283 Zoning Bylaw No. 2506 Page 284 Zoning Bylaw No. 2506 Page 285 7.59 CD-59 COMPREHENSIVE DEVELOPMENT ZONE (15241 Thrift Avenue) INTENT The intent of this zone is to accommodate the development of a multi-unit residential development on a site of approximately 2,451 square metres in area. 1. Permitted Uses: (a) multi-unit residential use (b) accessory home occupation use in accordance with the provisions of section 5.3 and that does not involve clients directly accessing the principal building 2. Lot Coverage: (a) lot coverage shall not exceed 53% 3. Density: (a) Maximum gross floor area shall not exceed 5.42 times the lot area, comprised as follows: (i) BASE DENSITY: The maximum gross floor area shall not exceed 4.97 times the lot area (ii) ADDITIONAL (BONUS) DENSITY: Where a contribution of $352,038 has been provided to the Community Amenity Reserve Fund to assist with the provision of the amenities in the following table, the maximum gross floor area shall not exceed 5.42 times the lot area # Amenity 1 New public open space and walkways 2 Improvement of existing open space and walkways 3 Public art 4 Waterfront improvement, including civic parking facilities 5 Special needs or non-market affordable housing 6 People movement infrastructure to link Uptown to the Waterfront The amenity must be provided in accordance with an amenity agreement and a section 219 covenant delivered by the owner of the subject real property to secure the amenity (b) The maximum number of dwelling units must not exceed 88 4. Building Height: (a) The principal building shall not exceed a height of 154.85 metres geodetic 5. Siting Requirements: Zoning Bylaw No. 2506 Page 286 (a) Minimum setbacks are as follows: (i) Setback from front (south) lot line = 3.12 metres (ii) Setback from rear (north) lot line = 7.54 metres (iii) Setback from exterior side (east) lot line = 2.48 metres (iv) Setback from interior side (west) lot line = 6.36 metres (b) Notwithstanding the above, balconies may encroach by up to 1.60 metres into the required front (south) lot line setback, 1.57 metres into the required rear (north) lot line setback, 0.96 metres into the required exterior side (east) lot line setback, and 1.72 metres into the required interior side (west) lot line setback 6. Parking: Parking shall be provided in accordance with Section 4.14, with the minimum number of spaces required as follows: (a) A minimum of 133 spaces shall be provided for the residential dwelling units (b) A minimum of 27 spaces shall be provided for visitors and marked as 'visitor' (c) A minimum of five (5) of the required 160 spaces (residential and visitor) shall be provided for disabled persons parking and shall be clearly marked in accordance with B.C. Building Code requirements 7. Bicycle Parking: Bicycle parking shall be provided in accordance with Section 4.16, with the minimum number of spaces required as follows: (a) A minimum of 91 Class I spaces shall be provided (b) A minimum of 19 Class II spaces shall be provided 8. Loading: (a) One (1) loading zone shall be provided for residential use in accordance with Section 4.15 9. General: (a) Development in this zone that includes the additional (bonus) density referred to in Section 3 shall substantially conform to the Plans prepared by Arno Matis Architecture Inc. dated January 6, 2017 that are attached hereto and on file at the City of White Rock (b) Development in this zone that does not include the additional (bonus) density referred to in Section 3 shall be required to obtain a new Major Development Permit Zoning Bylaw No. 2506 Page 287 Zoning Bylaw No. 2506 Page 288 Zoning Bylaw No. 2506 Page 289 Zoning Bylaw No. 2506 Page 290 Zoning Bylaw No. 2506 Page 291 Zoning Bylaw No. 2506 Page 292 7.61 CD-61 COMPREHENSIVE DEVELOPMENT ZONE (1310 Johnston Road) INTENT The intent of this zone is to accommodate the development of a mixed-use development on a site of approximately 1,516.1 square metres (0.375 acres) in area. 1. Permitted Uses: (a) multi-unit residential use (b) retail service group 1 use (c) licensed establishments, including liquor primary, food primary, agent store, u-brew and u-vin (d) medical or dental clinic (e) accessory home occupation use in accordance with the provisions of section 5.3 and that does not involve clients directly accessing the principal building 2. Lot Coverage: (a) lot coverage shall not exceed 80% 3. Density: (a) Maximum gross floor area shall not exceed 5,306.3 square metres, with a minimum commercial floor area of 431.5 square metres, and the maximum number of dwelling units shall not exceed 30, comprised as follows: (i) BASE DENSITY: The maximum gross floor area shall not exceed 2,653.1 square metres, and the maximum number of dwelling units shall not exceed 11 units (ii) ADDITIONAL (BONUS) DENSITY: Where a contribution of $850,000 has been provided to the Community Amenity Reserve Fund to assist with the provision of the amenities in the following table, the maximum gross floor area shall not exceed 5,306.3 square metres, with a minimum of 431.5 square metres of commercial floor area, and the maximum number of dwelling units shall not exceed 30 units # Amenity 1 New public open space and walkways 2 Improvement of existing open space and walkways 3 Public art 4 Waterfront improvement, including civic parking facilities 5 Special needs or non-market affordable housing 6 People movement infrastructure to link Uptown to the Waterfront Zoning Bylaw No. 2506 Page 293 The amenity must be provided in accordance with an amenity agreement and a section 219 covenant delivered by the owner of the subject real property to secure the amenity 4. Building Height: (a) The principal building shall not exceed six storeys 5. Siting Requirements: (a) Minimum setbacks are as follows: (i) Setback from front (south) lot line = 1.7 metres (ii) Setback from rear (north) lot line = 0.0 metres (iii) Setback from interior side (east) lot line = 0.0 metres (iv) Setback from exterior side (west) lot line = 1.8 metres (b) Notwithstanding the above, deck cornices may encroach by up to 0.36 metres into the required front (south) and exterior side (west) lot line setbacks 6. Parking: Parking shall be provided in accordance with Section 4.14, with the minimum total number of spaces required as follows: (a) A minimum of 1.5 spaces per unit shall be provided for the residential dwelling units (b) A minimum of 0.3 spaces per unit shall be provided for visitors to the residential dwelling units and marked as 'visitor' (c) A minimum of 15 spaces shall be provided for the retail service group 1 uses, licensed establishments and medical or dental clinic uses (d) A minimum of two (2) of the required spaces shall be provided for disabled persons parking and shall be clearly marked in accordance with B.C. Building Code requirements 7. Bicycle Parking: Bicycle parking shall be provided in accordance with Section 4.16, with the minimum number of spaces required as follows: (a) A minimum of 48 Class I spaces shall be provided (b) A minimum of 2 Class II spaces shall be provided 8. Loading: (a) One (1) off-street loading space shall be provided for the residential use and commercial use, and shall meet the loading space dimension requirements accordance with Section 4.15.3 Zoning Bylaw No. 2506 Page 294 7.62 CD-62 COMPREHENSIVE DEVELOPMENT ZONE (1453 Stayte Road) INTENT The intent of this zone is to accommodate the development of three-storey townhouse development on a site of approximately 3,163 square metres. 1. Permitted Uses: (a) Townhouse use (b) accessory home occupation use in accordance with the provisions of section 5.3 and that does not involve clients directly accessing the principal building 2. Lot Coverage: (f) lot coverage shall not exceed 42% 3. Density: (a) The maximum gross floor area shall not exceed 0.905 times the lot area. (b) The maximum number of dwelling units must not exceed 20. 5. Building Height: (h) The principal building shall not exceed a height of 73.5 metres geodetic. (i) Ancillary buildings and structures shall not exceed a height of 5.0 metres from the finished grade. 6. Siting Requirements: (e) Minimum setbacks are as follows: (i) Setback from front (east) lot line = 1.5 metres (ii) Setback from rear (west) lot line = 6.0 metres (iii) Setback from interior side (north) lot line = 4.0 metres (iv) Setback from interior side (south) lot line = 3.0 metres (f) Notwithstanding the above, the following siting exemptions are permitted: (ii) Balconies may encroach by up 1'-6" (0.46 m) and roofs projecting 1'-0" (0.31 m) into the setback from front (east) lot line (Block 1). (jj) Balconies may encroach by up 3' (0.92 m) and roofs projecting 1'-0" (0.31 m) into the setback from interior side (north) lot line. (Block 4). (kk) Balconies may encroach by 3' (0.92 m) and roofs projecting 1'-0" (0.31 m) into the 3.0m Setback from interior side (south) lot line (Block 3). (ll) Eaves may encroach by up to 1.6 metres into all required lot line setbacks. (iv) Ancillary buildings and structures may be located on the subject property in accordance with the Plans prepared by Atelier Pacific Architecture dated February 21, 2020 that are attached hereto and on file at the City of White Rock, with the exception that no ancillary buildings or structures are permitted within a 2.0 metre distance from the front (east) lot line Zoning Bylaw No. 2506 Page 295 7. Parking: Parking shall be provided in accordance with Sections 4.14 and 4.17, with the minimum number of spaces required as follows: (g) A minimum of forty (40) spaces shall be provided for the multi-unit residential use (h) A minimum of one (1) of the required forty (40) spaces shall be provided as accessible parking spaces and shall be clearly marked in accordance with the B.C. Building Code Requirements. (i) A minimum of four (4) stalls must have electric charging capacity. (j) A minimum of four (4) stalls must be roughed for electric charging capacity. 8. Bicycle Parking: Bicycle parking shall be provided in accordance with Section 4.16, with the minimum number of spaces required as follows: (c) A minimum of twenty (20) Class I spaces shall be provided (d) A minimum of four (4) Class II spaces shall be provided 9. Loading: (a) One loading space shall be provided for the multi-unit residential use in accordance with Section 4.15 Zoning Bylaw No. 2506 Page 296 Zoning Bylaw No. 2506 Page 297 Zoning Bylaw No. 2506 Page 298 Zoning Bylaw No. 2506 Page 299 Zoning Bylaw No. 2506 Page 300 Zoning Bylaw No. 2506 Page 301 7.64 CD-64 COMPREHENSIVE DEVELOPMENT ZONE (1485 Fir Street) INTENT The intent of this zone is to accommodate the development of a multi-unit residential building on a site of approximately 2,036 square metres, with the provision of affordable housing and a housing agreement bylaw in accordance with section 482 of the Local Government Act. 1. Permitted Uses: (1) multi-unit residential use; and (2) accessory home occupation use in accordance with the provisions of section 5.3 and that does not involve clients directly accessing the principal building 2. Lot Coverage: (g) For multi-unit residential uses, lot coverage shall not exceed 49% 3. Maximum Base Density: The following base density regulation applies generally for the zone: Maximum residential floor area shall not exceed 1.1 times the lot area, and maximum gross floor area shall not exceed 1.5 times the lot area. 4. Maximum Increased Density: Despite section 7.64.3, the reference to the maximum gross floor area of "1.5 times the lot area" is increased to a higher density of a maximum of 5,700 m2 (61,356.85 ft2) of gross floor area (2.8 FAR; or gross floor area ratio) and 80 apartment dwelling units where a housing agreement has been entered into and filed with the Land Title Office to secure eighty (80) dwelling units as rental tenure for the life of the building, with four (4) of these dwelling units being secured for a period of 10 years as having maximum rents set at the average rent for a private apartment in White Rock as indicated by the most current rental market report from Canada Mortgage and Housing Corporation. 5. Building Height: (j) The principal buildings for multi-unit residential uses, inclusive of elevator shafts, stair housing, and all mechanical equipment, shall not exceed a height of 129.2 metres geodetic; and (k) Ancillary buildings and structures for multi-unit residential uses shall not exceed a height of 5.0 metres from finished grade. Zoning Bylaw No. 2506 Page 302 6. Siting Requirements: (g) Minimum setbacks for multi-unit residential uses are as follows: (i) Setback from north lot line = 5.05 metres (ii) Setback from south lot line = 5.25 metres (iii) Setback from west lot line = 3.08 metres (iv) Setback from east lot line = 3.47 metres (h) Ancillary structures may be located on the subject property in accordance with the Plans prepared by Billard Architecture dated August 11, 2020 that are attached hereto and on file at the City of White Rock, with the exception that no ancillary buildings or structures are permitted within a 1.0 metre distance from a lot line. 7. Parking: Parking for multi-unit residential uses shall be provided in accordance with Sections 4.14 and 4.17, with the minimum number of spaces required as follows: (k) A minimum of ninety-six (96) spaces shall be provided for residents of the multi-unit residential use; (l) A minimum of twenty-four (24) spaces shall be provided for visitors and marked as "visitor"; (m) A minimum of three (3) of the required one hundred and eight (108) spaces shall be provided as accessible parking spaces, shall be clearly marked, and shall have a minimum length of 5.5 metres. Of the three accessible parking spaces, one space shall be provided as a van-accessible loading space with a minimum width of 2.8 metres, and the other two spaces shall have a minimum width of 2.5 metres, provided that the three parking spaces have a shared or non-shared access aisle with a minimum width of 1.5 metres; and (n) The minimum height clearance at the accessible parking spaces and along the vehicle access and egress routes from the accessible parking spaces must be at least 2.3 metres to accommodate over-height vehicles equipped with a wheelchair lift or ramp. 8. Bicycle Parking: Bicycle parking shall be provided in accordance with Section 4.16, with the minimum number of spaces required as follows: (e) A minimum of 94 Class I spaces shall be provided; and (f) A minimum of 16 Class II spaces shall be provided Zoning Bylaw No. 2506 Page 303 9. Loading: (a) One loading space shall be provided for a multi-unit residential use in accordance with Section 4.15 10. General: Development in this zone that includes the additional (bonus) density referred to in Section 4 shall substantially conform to the Plans prepared by Billard Architecture dated August 11, 2020 that are attached hereto and on file at the City of White Rock Zoning Bylaw No. 2506 Page 304 Zoning Bylaw No. 2506 Page 305 Zoning Bylaw No. 2506 Page 306 Zoning Bylaw No. 2506 Page 307 Zoning Bylaw No. 2506 Page 308 7.66 CD-66 COMPREHENSIVE DEVELOPMENT ZONE (1539 Maple Street) INTENT The intent of this zone is to accommodate the development of a multi-unit residential use within five stacked townhouse blocks on a site of approximately 4,566 square metres (0.45ha). 1. Permitted Uses: (a) multi-unit residential use; and (b) accessory home occupation use in accordance with the provisions of section 5.3 and being a use that does not involve clients directly accessing the principal building. 2. Building Height: (a) The principal buildings for multi-unit residential uses, inclusive of elevator shafts, stair housing, and all mechanical equipment, shall not exceed the maximum geodetic heights as outlined below. The Block references noted correspond with those illustrated in the Plans forming part of this CD-66 Zone: (i) Block 1: 104.51 metres (342.88 feet) (ii) Block 2: 104.51 metres (342.88 feet) (iii)Block 3: 104.51 metres (342.88 feet) (iv) Block 4: 105.01 metres (344.52 feet) (v) Block 5: 105.51 metres (346.16 feet) For reference, the average natural grade applicable to the development is 93.4 metres (306.35 feet) geodetic. (b) Ancillary buildings and structures for multi-unit residential uses shall not exceed a height of 5.0 metres from finished grade. 3. Maximum Density (Floor Area): (a) The maximum gross floor area shall not exceed 5,953.4 square metres or 1.304 times the lot area; and (b) The maximum number of dwelling units shall not exceed 53 units. 4. Siting Requirements: (a) Minimum setbacks for multi-unit residential uses are as follows: (i) Setback from the north lot line = 1.82 metres (6.00 feet) (ii) Setback from the south lot line (Russell Avenue) = 1.82 metres (6.00 feet) (iii) Setback from the west lot line = 2.43 metres (8.00 feet) (iv) Setback from the east lot line (Maple Street) = 3.04 metres (10.00 feet) (b) Despite section 7.66.4(a), limited portions of principal buildings, ancillary structures, and exterior walkways are permitted within the minimum setbacks in accordance with the Plans prepared by Ankenman Marchand Architects, dated Aug. 19, 2021, attached hereto and on file at the City of White Rock, with the exception that no ancillary buildings or structures are permitted within 1.0 metres of a lot line. Zoning Bylaw No. 2506 Page 309 5. Lot Coverage: (a) For multi-unit residential uses, lot coverage shall not exceed 61%. 6. Standard and Accessible Off-Street Parking: Parking for multi-unit residential uses shall be provided in accordance with Section 4.14 of this Bylaw, with the minimum number of spaces required as follows: (a) A minimum of 108 standard parking spaces shall be provided for residents; (b) A minimum of 18 standard parking spaces shall be provided for visitors; (c) A minimum of 3 parking spaces must be provided as accessible spaces, shall be clearly marked, and must have a minimum length of 5.5 metres. Two of these spaces shall be provided as a van-accessible space with a minimum width of 3.4 metres, and the other space shall have a minimum width of 2.5 metres. Each accessible parking space must be located adjacent to an access aisle having a minimum width of 1.5 metres; and (d) The access and egress route to and from accessible parking spaces must have a vertical clearance of 2.3 metres. 7. Off-Street Loading: (a) Notwithstanding any provision within Section 4.15 to the contrary, one loading space shall be provided for a multi-unit residential use with the minimum dimensions of this space being 3.0 metres wide and 9.0 metres long; and (b) The access and egress route to and from the loading space must have a vertical clearance of 3.7 metres. 8. Bicycle Parking: Bicycle parking shall be provided in accordance with Section 4.16 of this Bylaw with the minimum number of spaces required as follows: (a) A minimum of 53 Class I spaces shall be provided; and (b) A minimum of 14 Class II spaces shall be provided 9. Electric Vehicle Parking Electric vehicle (EV) parking shall be provided in accordance with Section 4.17 of this Bylaw, with the minimum number of EV parking spaces required as follows: (a) A minimum of 25 percent of the required parking supply shall be provided an energized outlet capable of providing a Level 2 charge, or higher for electric vehicle charging; and (b) A minimum of 75 percent of the required parking supply shall be located within three (3) metres of an electrical outlet roughed-in for electric vehicle charging . 10. Conformity to Design Plans Development in the CD-66 Zone shall substantially conform to the Plans prepared by Ankenman Marchand Architects, dated Aug. 19, 2021 attached hereto and on file at the City of White Rock. Zoning Bylaw No. 2506 Page 310 11. Road Dedication The siting and lot coverage standards established within this CD-66 Zone shall apply to the legal perimeter (outermost) boundaries, and total area, of the assembled parcels as they existed at the time of first and second reading of this Bylaw and prior to any road dedications. Zoning Bylaw No. 2506 Page 311 Zoning Bylaw No. 2506 Page 312 Zoning Bylaw No. 2506 Page 313 Zoning Bylaw No. 2506 Page 314 Zoning Bylaw No. 2506 Page 315 Zoning Bylaw No. 2506 Page 316 Zoning Bylaw No. 2506 Page 317 Zoning Bylaw No. 2506 Page 318 EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEE EEE EEE EEE EEE EEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEE EEE EEE EEE EEE EEE EEE EEE EEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEEEE EEEEEEEE EEEEEEEE EEEEEEEE EEEEEEEE EEEEEEEE EEEEEEEE EEEE EEEE EEEE EEEE EEEE EEEE EEEE EEEE EEEE EEEE EEEE EEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEE EEEE EEEE EEEE EEEE EEEE EEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEE EEE EEE EEE EEE EEE EEE EEE EEE EEEEEE EEEEEE EEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEEEEEE EEEEEEEEEE EEEEEEEEEE EEEEEEEEEE EEEEEEEEEE EEEEEEEEEE EEEEEEEEEE EEEEEEEEEE EEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEEEEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEE EEE EEE EEE EEE EEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEE EEE EEE EEE EEE EEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEE EEE EEE EEE EEE EEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEE EEEEE EEEEE EEEEE EEE EEE EEE EEE EEE EEE EEEEE EEEEE EEEEE EEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEE EEE EEE EEE EEE EEE EEE EEE EEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEE EEEE EEEE EEEE EEEE EEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEE EEE EEE EEE EEE EEE EEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEE EEEE EEEE EEEE EEEE EEEE EEEE EEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEE EEEE EEEE EEEE EEEE EEEE EEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE E E E EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEE EEE EEE EEE EEE EEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEE EEE EEE EEE EEE EEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEEEEEEEEE EEEEEEEEEEEEEE EEEEEEEEEEEEEE EEEEEEEEEEEEEE EEEEEEEEEEEEEE EEEEEEEEEEEEEE EEEEEEEEEEEEEE EEEEEEEEEEEEEE EEEEEEEEEEEEEE EEEEEEEEEEEEEE EEEEEEEEEEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEE EEEE EEEE EEEE EEEE EEEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEE EEE EEE EEE EEE EEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEEEEEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEE EEEE EEEE EEEE EEEE EEEE EEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEEEE EEE EEE EEE EEE EEE EEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEEE EEEEE EEEEE EEEEE EEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEEEEE EEEEEE EEEEEE EEEEEE EEEE EEEE EEEE EEEE EEEEE EEEEE EEEEE EEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEEEEEE EEE EEE EEE EEE EEE EEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEEEEE ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " 1354 1355 1368 13910 1569 13922 13936 13948 13976 1429 13962 13988 1451-97 1389 15115 15369 14366 15658 15668 14356 1381 15644 15632 1384 15548 15809 14884 15619 13970 14884 15600 15718 15618 1125 1135 1115 1115 1117 15431 926 920 1112 1145 1145 1531 1144 1124 1141 1160 1161 1171 15708 14836 15788 1549 1545 14367 1164 14818 15226 14880 963 14844 14854 15836 1559 14826 14872 1154 943 1157 1170 15969 1558 15781 14491 14809 14635 14627 14619 1480 14834 14824 1377 1321 1353-57 1155 1175 1165 1126 1136 1176 1467 1166 1156 1146 1493 1127 1464 1126 1471 1135 1153 1152 1136 953 1152 1377 15826 1117 1144 1501 1134 1417 14378 15778 1127 1137 1152 1155 1162 1543 1165 1511 1523 14379 1500 1091 1061 1134 1126 1340 1177 14833 15628 1137 1370 14821 1371 1341 1165 1331 14357 1041 1031 1051 1145 1330 1350 1081 1127 13805 14390 1569 1071 13841 1320 15648 1016 1360 1147 1361 1351 14831 13842 1321 1533 14862 1352 13832 13821 1511 14884 1568 1535 1520 14844 1510 932 14391 1588-92 14640 931 15471 1540 1578 15511 15556 15866 13851 15491 15501 15876 1530 1509 15856 13852 15970 15541 15521 13874 13873 14843 15481 13879 13859 13860 15461 1185 15531 1336 15381 1363 15990 1355 15565 1126 1137 1159 15982 1418-24 1554 15966 15958 14809 15789 15555 15689 15681 15974 15671 1156 15987 15692 15881 14481 1146 15827 1136 13940 15919 13982 13806 13822 13831 1333 13865 13866 1365 1347 1341 15825 976 923 1362 15980 15985 14457 953 15660 15810 15962 15672 15771 15965 14463 15829 922 906 15682 928 977 928 1347 14883 929 972 15729 1127 905 966 929 15929 15829 15877 15661 14887 1376 1368 15559 15316 13965 14471 15761 14822 15839 15736 1481 15709 14820 15679 1587 14853 1155 15226 15110 14845 1577 15728 15754 15800 15159 15226 15846 15719 13986 15118 14873 1186 15611 14815 1470 15544 14834 14863 15554 15851 14615 15861 15819 15639 15550 15645 15566 15607 15576 15615 15629 15158 15882 15880 15168 14639 15159 15546 14631 15931 13955 15764 13950 15933 911 967 912 918 967 938 973 912 918 922 963 938 959 953 949 942 942 948 943 952 952 948 939 966 958 958 982 972 923 990 991 919 976 978 987 982 983 973 977 986 943 958 932 949 938 952 972 942 948 986 939 982 912 932 932 962 933 986 962 933 15913 15708 15910 1158 14785 1530 1117 13950 13960 1171 14659 13975 14675 14653 14667 13970 13956 14645 14683 13960 13950 13940 14623 962 1156 1387 1011 947 15977 14451 13971-74 1510-48 15400-25 14560 14568 14548 1449 15556 15884 15890 15896 14403 14411 14635 14615 14607 14645 14611 15454 15565 15619 15571 15569 14611 15455 15457 1138 15048 1338 1333 1448 15317 15568 15570 1152 15096 15078 15062 15068 15046 15050 15086 15056 15080 15058 15072 1538 1560 1561 1550 1526 1527 1551 1511 1571 1570 1519 1501 1496-1512 14195 1539 1537 1516 1470 1580 1480 14191 14181 13768 13766 13778 1589 13740 13742 13706 13842 13806 13801 13841 13832 13822 13821 13831 13790 13852 13879 13866 13851 13876 13873 13857 13865 13688 13684 13726 13736 13716 13696 13756 13860 14376 1575 1580 1550 1570 1565 1551 1540 1541 1530 1531 1560 14379 14357 14367 14391 1590 14366 1520 1521 1561 1550 1442 1589 15020 1509 1467 1458 1410 1437 1430 1520 1520 1508 1497 1497 1480 1480 15035 14990 1459 1580 14980 14957 1441 1480 1473 1456 1434 1464 1450 1482 1481 14921 1424 1552 14937 1441 1558 1548 1518 1520 15765 1538 1523 1580 1583 1593 15870 1540 1550 1520 1500 15818 15866 15860 15867 15857 15847 15815 15825 15845 15835 15871-73 1560 1570 15880 15881 1530 1595 1510 1573 13620 13975 1560 1570 13954 1550 13968 13955 1595 13985 1533 1532 1575 1567 1561 1551 1522 1541 1540 14331 14343 1516 14321 1585 1530 15176 1513 1549 1531 1500-08 15111-25 1538 15141 1521 15221-45 1556 1556 15280 1555 1554 1526 1533 15395 15387 15399 15383 15391 15465 15465 1588 15466 15445 1570 1560 1550 1540 1580 1543 1553 1563 1573 1530 1593 1533 1583 15674 15664 15675 15665 15655 15685 1533 1563 1543 1553 1583 15870 15863 15916 15904 1573 1505 1550 1593 1596 15903 15931 15890 15880 15883 15873 15928 15911 15860 15855 15851 15866 15859 13645 13677 13657 13707 13629 13735 13721 13751 13691 1390 13835 13815 13795 13785 13845 13857 13825 13863 13805 13772 13782 13802 13902 13822 13832 13892 13898 13882 13872 13775 13812 13842 13792 13615 13770 13763 13769 13614 13688 13622 13678 1410 1430 13654 13642 13630 13662 13670 13702 13638 13726 13718 13740 13734 13710 13608 1420 13694 13822 13852 13836 13660 13706 13736 13690 13720 13768 13674 13752 13790 13778 13808 13866 13880 13894 13892 13616 1491 1481 1471 13900 1523 14047 14075 14037 14069 14057 1512 14119 14109 14151 14083 14093 14027 14003 14017 13976 13910 13962 13922 13936 13950 1474 1463 1473 14061 1455 1403 14093 1462 14046 14093 14036 14150 1451 1441 14115 14101 14126 14131 14139 14109 14123 1405 14056 14068 14084 14074 14120 1462 14096 1407 14127 14115 14130 14077 14112 14022 14103 14012 14110 14120 14104 14006 14032 14048 14020 14146 14112 14140 14104 14122 14136 14233 14252 14242 14262 14222 1537 14282 1549 14283 14263 14272 14232 1399 1389 14183 14229 14239 14249 1413 14171 1393 14161 14244 1351 14195 1435 14213 14265 14205 14283 14254 14273 14290 14284 14259 1397 14284 14262 14262 1375 1385 14233 14244 14254 14253 14243 14263 14170 14176 14194 14186 14238 14220 14210 1349 1401 14190 14154 14164 14200 14210 14172 14188 14220 14319 14309 14342 1476 14330 14341 14331 14320 1461 1477 1466 14357 1414 14328 14331 14320 14342 14343 14321 14343 14358 14381 14506 14505 14518 14485 14486 14496 14519 14495 14500 14510 14520 14417 14433 14475 14481 14490 14442 14450 14428 14455 14430 14410 14420 14444 14458 14470 14448 14472 14509 14480 1282 14602 14591 14585 1349 1329 1309 14684 14670 14622 14652 14644 14608 14638 14630 14666 14658 14616 1311 1349 14717 14774 14732 14773 14787 14748 14777 14733 14737 14782 14757 14756 14760 14763 14752 14736 14774 14712 14779 14713 14742 14723 14767 14728 14745 14718 14753 14706 14729 14705 14792 14732 14763 14742 14748 14767 14728 14706 14707 14717 14722 1289 14729 14743 14783 14756 14733 14766 14786 14753 14787 14747 14790 14773 14752 14737 14777 14713 14760 14778 14772 14723 14793 14712 1399 14711 14716 14742 14748 14747 14756 14712 14751 14739 14799 14717 14771 14786 14774 14757 14761 14767 14756 14776 14766 14770 14726 14777 14720 14727 14736 14735 14721 14708 14705 14728 14733 14778 14783 1259 1285 1289 14868 1279 14862 14828 14838 14820 14824 14806 14846 14850 14810 14856 14816 14811 14867 14853 14827 14823 14825 14819 14874 1447 1467 15380 1481-87 1450 1488 1438 1436 15489 15631 1415 1445 15743 1464 15676 1498 1454 1440 15780 15771 15702 15700 15701 15751 15750 15730 15731 15741 15740 15685 15691 15681 15711 15720 15770 15721 15710 15712 15761 15761 15760 15722 15751 15713 15690 15717 15677 15666 15752 15742 15686 15668 15732 15696 1475 15762 15920 15910 1426 15911 1446 15855 15861 15860 15827 15858 15847 15818 15838 15881 15828 15880 15837 15871 15848 15870 15857 15859 15805 15919 15815 15816 15915 1407 15921 15925 15822 1409 15916 1474 1455 1475 1485 1466 1465 15856 15826 15827 15858 15884 15883 15862 15861 15840 15847 15863 15837 15873 15836 15930 15810 15848 15817 15818 15915 15917 15909 15872 15857 15859 15952 15991 1453 1450-68 1471 1489 1321 1341 15632 1371 15644 15631 15621 1330 1390 1380 1370 1360 1350 1340 1320 1331 15611 1351 1361 1367 1351 1341 1323 15734 1377 1361 1370 1336 1346 1366 1388 1356 1326 15741 15731 15711 15721 15718 15881 1319 1350 1340 1356 1366 1335 1341 1368 1361 1351 1325 1373 15942 1368 1348 15900 1388 15930 1305 15824 15884 1338 15836 1385 1378 15844 1358 15830 15920 15894 15910 15993 15860 15990 15850 15876 15953 15980 15970 15973 15963 15870-72 15644 15607 15617 15643 1276 1266 1256 1246 1257 1267 1287 1237 1247 15610 1225 15663 1235 1255 1295 1238 1258 1248 15683 15670 15660 1228 1245 1285 1265 1275 1278 1268 1293 1283 1263 1253 1286 1296 1256 1276 1233 1238 1236 1226 15731 15721 15727 1243 1225 1266 1215 1212 1233 1243 1263 1247 15841 15966 15974 15970 15905 15917 1257 15931 15941 1226 15895 1216 15831 1213 15885 15823 15880 15876 15881 1283 1293 15877 15973 15887 15871 15953 15818 15890 15983 15886 15960 15963 15957 15807 15954 15958 15962 15669 15657 15639 15647 1170 15631 1162 15608 15622 1111 1130 1131 1151 1172 1171 1161 1181 1141 1121 1136 1150 15609 1160 1140 15621 15690 15678 1154 1142 1125 1155 1165 1175 1135 1145 15924 1115 1196 15948 1186 15916 1011 1070 1012 1050 1040 1060 1080 15708 1021 1061 1031 15725 1071 1081 1051 15719 1041 1030 15718 15728 15738 1041 1090 1071 1022 1023 1060 1050 1070 1040 1080 1032 15822 15877 15872 15891 15852 15862 15832 15842 1049 1061 1033 1062 1052 1072 1045 15927 1079 1029 1027 15909 1047 1071 1040 1082 1038 1042 15929 1092 15930 15920 15933 15939 15921 15908 15919 1035 1070 1066 1038 1032 1056 1046 1045 990 986 962 966 952 958 972 948 932 922 928 918 949 973 919 967 913 923 953 933 983 963 929 991 987 959 942 943 982 976 977 939 938 15611 927 15831 15827 15817 15837 15841 15821 873 863 853 829 872 852 828 862 867 849 843 839 833 887 883 891 877 859 882 866 848 842 838 832 886 878 858 15875 886 872 862 844 867 852 876 890 847-49 857-59 889 866 848 873 863 858 15880 15870 853-55 15809 877 877 877 877 877 877 877 877 838 877 877 877 877 832 877 877 877 877 877 877 828 831 15783 15783 15791 888 866 876 853 882 15606 872 856 849 15619 15605 15611 15621 1350 1371 14989 14950 1390 1376 1308 1351-53 14934 1322 1350 14916 1340 1360 1332 1370 15018 1367 1366 1327 1390 15380 1338 1346 1347 1378 1323 15303-11 1379 1360 1360 1351 1360 1351 1340 1331 1331 15265 1350 1328 1350 1371 1350 1321 15289-99 1360 1390 1341 1371 1321 15088 1359 1365 1322 1330 1331 1321 1319 1351 1381 1361 14938 1286 1278 14938 14911 1266 15021 1216 15018 15010 1219-29 15050 15031-33 1291 1281 15070 15080 15083 15081 15089 15093 15070 15069-71 1280 15168 15150 15154-58 15130 1289 1281 1259 1259 1270 15115 15163 15161 15151 15151 15151 1219-23 15169 15130 15138 15139 1230-32 15120-22 15131 15109 1251 1203 15579 15518 15573 15569 15555 15537 15598 15561 15548 15551 15531 15515 15577 15552 15588 15545 15523 1259 1267 1219 15490 15423 15492 15546 15496 15526 15516 15557 15517 15521 15519 15506 15556 15505 15497 15536 15564 14985 14981 1187 14986 1135 1155-57 14971 14994-96 15084 15052 15067 15068 15078 15064 15056 15046 15055 15047 15043 15126 15134 15146 15124 15109 15079 15051 15063 15067 15075 15055 15071 15087 15091 15083 15059 1136 15047 15130-48 15154 15190 15120 15176 15180 15170 15122 15162 15110 1135 15187 15129 15157 15117 15147 15141 15135 15173 15177 15169 15121 15151 15163 15109 15158 1105 15128 15188 15180 15176 15134 15124 15110 15118 15140 15185 15129 15117 15141 15181 15169 15175 15135 15123 15169 1097 15193 1088 15188 15187 15190 15168 15180 15170 15179 15175 15169 15156 15140 15135 15128 15125 15148 15145 15155 15100 15010 15213-33 15201 15284 15259 1191 1164 15525 15535 15545 15566 1174 1095 1087 15587 15581 1131 15205 1047 15322 15315 1174 15416 15432 15422 15413 15440 15405 15395 15421 15385 15518 15506 15472 15492 15517 15482 15516 1109 15554 15544 15528 15365 15377 15371 15357-61 1066 15341 1129 15388 15390 15392 15404 15394 15398 1164 15374 1053 15481 15511 15503 15495 15596 15585 15588 15580 1051 15567 15575 15445 15457 15441 15421 15409 15417 15427-31 1033 15446 1088 15438 15422 15430 15410 15485 1036 1031 15493 15501 15520 15482 15494 15502 15489 1038 1000 1020 1028 15525 15574 15340 15307 15408 15430 15416 15438 15450 15444 15424 951 15577 15583 15581 15587 1580 14254 14264 14290 14276 14240 14420 15095 15151 15147 15196 15157 1146 15160 15161 15212 1055 15220 15195 15930 1445 1429 1419 15869 15217 15239 15231 15245 15227 15288 15235 15257 15249 15221 15272 15253 15256 15276 15268 15260 15265 15292 15252 15223 15284 15248 15261 15264 15241 15280 15238 1058 15295 15305 15311 15279 15328 15275 15315 15301 15319 15287 15320 15350 15283 15327 15323 15291 15340 15346 15330 15324 15316 15304 15312 15356 15575 15553 15561 15571 15565 15586 15556 15552 15560 15594 15583 15592 15579 15582 15576 15590 15549 15557 15580 15589 15574 15582 15588 15590 15570 15578 15548 15564 15581 883 15591 14648 14658 14664 1499 1493 15150-62 15096 15090 15092 15088 1200 15061 15176-78 1220 1280 1273 1225 1355 1331 1320 1062 1111 1173 1273 14056 14423 14460 1390 14434 14903 15334 15498 15090 15114 1575-77 1058 15908 15890 1388 15919 15923 15568 14888 14768 15595 15928 15100 14268 14138 1265 1208 976 14268 14870 1180 14848 14858 15293 14111 14789 14250 15080 898 14426 15357 15389 15738 15654 15600 15600 1475 15521 15521 1561 1595 1575-76 15334 14518 14600 1475 14516 15318 14504 14496 15310 14486 14476 15280 14472 14462 14452 14446 14431 1550-51 1580-81 1588 14421 14306 14320 1590 14040-46 14056 14068 14078 14110 14120 14130 14140 1581 1590 14162 14168 14182 14194 14204-06 14216 14232 14243 14253 14263 14290 1586 1588 1589 1590 13902 13924 13668 13644 1580 1578 14237 1579 14273 14283 1578 1599 14465 14455 14445 1580 1593 1569 1570 1571 1570 1555 14519 14517 14505 14495 14485 14475 15921 1583 13791 13777 13765 13755 13751 13741 13735 13725 13715 13705 13697 13689 13685 13675 1558 15931 1596 1598 14089 14099 14111 14079 14069 14121 14057 14131 14047 14141 14151 14035 14023 1568 14013 1562 1562 1560 1561 1561 1560 14411 14423 1588 1550 1558 1563 1558 1573 1558 1550 1551 1553 1554 14437 1552 1550 1553 1568 1531 1544 1548 1563 14447 1540 1545 1541 1538 1542 14528 14476 14466 1544 1548 15854 15450 1540 1539 1544 13756 13764 13742 13736 13768 13726 13716 13776 13706 13790 13698 13688 13684 13674 14451 1543 1553 1538 14259 14261 14012 14022 14034 14046 14050 14056 14068 14084 14094 14098 14110 14120 14130 14140 1527 1530 1537 1542 1531 1530 15852 1532 14424 14257 14459 1530 1543 1521 1532 1536 1528 1520 1520 1529 1521 1520 14475 1501 15321 14430 1510 1500 1533 1530 1522 1500 13685 13689 13697 13705 13715 13725 13735 13741 13751 13755 13765 13777 13791 1518 14436 1519 13909 1510 1511 13645 13621 1500 14255 15261 15731 15721 1510 14446 14264 14284 1512 1508 13915 14407 14256 14456 1515 14476 1508 14258 14530 14480 14262 14260 1501 1492 1480 1485 1500 1488 1454 1487 1501 1486 1495 15630 15620 15610 13746 13742 13736 13728 13720 13712 13698 13696 13688 13680 13672 13664 13656 13648 13640 13632 13624 13616 13608 13600 15530 14441 14523 14243 14253 14263 14273 14283 14291 1478 1474 14447 14513 1476 14457 14501 14495 14485 1464 1485 13911 1468 15497 15771 15781 1465 1466 14205 14213 1460 1461 14520 13741 13735 13727 13721 13713 13705 13697 13689 13673 13665 13657 13649 13641 13633 13625 13617 13609 13601 1454 1475 14432 1455 1442 13923 1422-56 14001-47 1456 1461 14440 1465 1444 14448 1450 1455 1437 1461 13970 13960 14458 13950 1446 14510 1455 14462 1444 14844 14220 14500 14468 14478 14486 1444 1302 13922 13912 1440 1455 15680 15686 15772 14210 13862 15782 13852 1434 14166 14176 14186 14194 13760 1435 13748 1455 1431 1434 1434 14500 1425 15131 1430 1424 1400 14815 15705 15695 13987 13975 13963 13951 13937 14491 13925 13915 15659 15651 15291 13903 13891 13881 13873 1408 14171 14181 14195 14203 14211 14221 14356 14366 14378 14390 14234 14191 1392 15240 15290 1394 15430 15438 15448 15458 15468 15476 1402 15488 15502 15510 15520 15758 15530 15776 1389 15622 15540 15550 15560 15568 15578 15590 14033 14008 13986 1409 1386 14502 14034 14046 15240 1378 15250-64 1378 1384 14056 14064 1386 14371 1389 1369 1384 1369 1368 1360 15421 15431 15439 15449 15459 15469 15479 15489 15495 15501 15511 15521 15531 15551 14533 15561 15569 15579 1361 1365 14474 14381 14391 1366 14410 1355 1356 14499 14430 1341 14440 14310 14321 14334 1328 1350 1349 1350 15417 15450 15460 15470 15480 15490 15500 15510 15520 15530 15540 15550 15560 15580 1341 14516 14370 14380 14390 1340 1339 1318 14508 1328 1308 14524 14500 1334 14230 1323 14424 1320 1319 1330 1310 1315 15241 14391 15449 15451 1320 15551 15561 14462 14480 15571 15581 1331 1310 15767 14498 14411 14500 1313 15775 1324 14507 1310 15241 14517 14452 1300-1310 14527 1320 14535 14471 14638 14358 14559 14553 14547 14432 14434 14376 14436 14455 14457 1290 1285 1289 15010 1288 15420 15430 15440 15448 15468 15810 15820 15858 15876 15880 15884 1292 15900 15918 15930 15952 14466 15589 15578 14478 14479 14489 14495 14501 14508 14528 1287 1279 15937 1282 1286 14560 1276 15427 15535 15437 1553915543 15449 15565 15828 14693 15935 1280 1279 1275 1272 1276 1255 1265-67 15041 1250 1267 1250 15560 14433 14941 14925 15907 15905 15885 15531 1266 14847 15830 1273 15547 15556 14782 14752 14569 14728 1264 1266 1262 14579 14585 14591 1267 14597 1250 1267 15832 14607 15527 15831 15525 1256 1234 1252 15544 15834 15448 15569 1245 1229 15479 15523 15444 1244 15420 15430 1244-46 15540 14641 1243 15836 14810 15565 1242 14647 14824 1235 14858 14834-38 14655 15954 15898 15908 15526 15916 15930 15838 1238 1233 1240 14661 15870 1239 1236 14669 1234 1231 15840 15940 14586 1232 15950 15536 14683 15522 15564 15633-39 1230 1232 15433-37 15441-57 15463 1230 1233 1227 1209 1228 1225 1228 15532 1225 15568 15530 15572 1226 14877 1215 15367 15409 14869-75 15627 14523 1220 14861 14847 14841 14811 14811 1195 14788 14744 14730 15391 15787 15777 15737 1216 14907 14811 1185 14977 14968 14842 14850 14854 14856 14864 14878 14889 14895 14903 14935 14981 14987 14995 15015-25 15638 1101-41 14825-69 1178 1153-69 1164 14960 14980-82 15472 1170 1186 1176 1167 15262 1157 15482 1176 15208-28 15490 15498 1160 1166 15506 15445 15219 1148 14881 1148 1137 14955 14967 15453 15276 1144 1156 15459 1166 1147 15282 14899 15465 15290 15473 1113-19 14909 1146 1130 15302 15481 1121 15310 15281 1130 1136 15316 1120 15281 15322 15450 15515 15289 15226 15460 15295 15917 1126 15521 15234 15921 15338 15031 15303 15468 15242 15529 15346 15311 15476 1107 15407 15539 14959-73 15911 15354 15317 15482 15549 15360 15329 15417 1110 1085 15370 14995 1105 15427 15341 15280 1081 1089 15437 1100 15217 15347 15288 1080 15445 15294 15355 15518 1089 15790 1090 1091 15970 1090 15451 15302 15361 1079 15528 15459 15310 15371 15534 15316 1081 1081 15251 1080 1081 15322 15542 1066 15257 1085 15265 1071 1070 1071 15271 1071 15346 15277 15354 15285 1065 1060 1067 15360 1061 15291 15368 1061 15374 1050 1051 15382 1051 15315 1055 15388 15855 15321 1040 1041 15662 15327 1041 15652 15335 15642 15605 15615 15623 15631 15639 15643 15341 1033 15349 1033 1020 15357 15653 1025 15649 15805 15815 1010 15659 1011 15383 15458 15837 15821 15391 15663 15765 15397 15578 15403 15482 15411 993 15488 15417 15494 15425 15502 985 15508 15964 991 990 15535 15788 15770 991 990 15441 15518 973 15447 988 986 986 986 15520 15455 983 983 976 985 987 982 982 983 982 15465 963 15469 981 976 981 990 977 983 976 977 976 15477 977 972 967 972 971 972 973 972 15483 15491 967 966 966 966 971 966 965 965 963 962 965 962 961 962 965 962 959 958 961 956 958 959 959 958 953 952 951 952 952 953 955 953 952 949 948 949 948 951 949 948 948 945 942 949 947 942 943 943 942 938 943 938 943 938 941 939 939 938 935 932 935 935 936 932 935 932 933 928 931 932 928 933 931 929 928 928 923 922 925 922 923 923 922 918 919 918 919 919 918 912 913 913 15791 912 912 916 15679 906 909 15773 15725 15707 15671 907 15930 15912 15790 15774 15768 15726 15716 891 15670 891 887 886 887 886 887 887 887 882 883 882 883 882 877 883 883 877 876 877 876 876 877 877 873 872 871 872 873 868 873 867 866 867 867 866 866 867 866 867 863 862 861 862 861 862 863 862 863 859 858 857 858 859 858 858 859 853 853 852 853 852 849 848 849 850 849 848 853 848 845 842 839 842 842 843 843 842 839 838 839 838 838 839 838 832 835 835 832 833 832 833 832 828 829 829 828 829 828 1522 15989 15717 15941 820 808-20 14420 15638 14938 1455 888 1350 927 971 987 974 15050 967 15777 15097 991 987 975 971 15781 15783 14373 14342 14517 14523 1138 15141 1405 1441 15152 15154 1473 15747 991 14780 14970 15438 15442 15448 15776 1295 1285 1426 14855 14439 919 1439 15989 15993 15999 1251 14989 15920 15930 14129 14139 1575 1293 14088 14098 14825 14935 1589 15387 1113 1255 1265 14971 15673 15683 15890 15894 15177A 14401 15565 14236 14310 14290 14320 14330 14336 14342 14312 14517 14517 14559 14555 14547 14551 1282 14550 14718 14742 1235 14760 14756 14776 14722 14772 14732 14738 14762 14768 14786 14708 14712 14732 14784 14783 14760 14748 14779 14773 14768 14774 14764 14723 14778 14756 14763 14767 14738 14757 14717 14713 14707 14741 14737 14753 14749 14745 14733 1163 1175 14837 14857 14831 14851 14968-72 1246 14954 14859 14837 14863 14851 14832 14866 14919 14918 14910 14911 14945 14950 14937 14931 14921 14941 14979 14971 14991 14969 14933 14987 14975 14947 14970 14961 14968 14937 14961 14957 14957 14975 14941 14979 14929 14999 14947 14917 14933 14946 14934 14955 14949 14960 14946 14949 14955 14945 1122 14935 14990 14989 14985 14981 15011 15015 15007 15019 15021 15025 1120 1080 15097 15094 15087 15078 15062 15070 15054 15093 15095 15066 15089 15050 15086 15082 15090 15074 15058 15083 15079 15075 15065 15061 15042 15042 15050 15070 15096 15062 15068 15048 15066 15084 15078 15056 15054 15098 15046 15082 15086 15047 15053 15069 15073 15061 15057 15065 15081 15085 15089 15073 15811 15807 15681 15667 15677 15671 15691 15683 15165 15147 15122 15162 15188 15211 15170 15108 15112 15118 15123 15129 15216 15298 15322 15278 15304 15264 15256 15240 15222 15226 15244 15182 15234 15260 15248 15282 15128 15230 15294 15300 15274 15286 15310 15156 15316 15220 15191 15290 15148 15134 15152 15196 15138 15318 15238 15142 15176 15135 15117 15181 15113 15192 15187 15233 15237 15215 15109 15225 15221 15229 15252 910 979 15392 873 15441 15331 15389 15372 15457 15420 15511 15541 15513 15341 15373 15479 15510 15539 15431 15542 15411 15561 15365 15519 15485 15361 15449 15531 15415 15357 15482 15518 15515 15427 15349 15481 15514 15490 15560 15419 15499 15503 15556 15526 15530 15495 15557 15381 15527 15423 15388 15517 15376 15445 15507 15407 15404 15549 15522 15536 15533 15412 15548 15395 15540 15491 15523 15369 15385 15553 15353 15486 15573 15453 15380 15384 15377 15552 15416 15400 15435 15507 15506 916 15408 15440 15512 15506 15498 15480 15494 15452 15484 15448 15516 15444 15528 15490 15502 15522 15456 15424 15480 15475 919 15223 15227 15235-37 15596 15598 852 872 852 828 873 859 15957 15963 15971 15665 15655 15645 15498 15511 15518 15510 15444 15438 15435 15531 15454 15459 15470 15468 15525 15473 15521 15493 15469 15474 15434 15488 15477 15460 15453 15445 15439 15449 15465 15440 15509 15520 15496 15436 15512 15560 1428 15501 15492 15467 15420 15476 15448 15526 15530 15456 15523 15578-82 15511-15 15592 15588 15425 1418 15585 15433 15423 15579 15462 15436 15541 15591 15480 15439 15488 15539 15468 15447 15443 15495 15544 15429 15419 15573 15451 15540 15440 15497 15481 15475 15479 15486 15484 15430 15487 15444 15554 15597 15510 15409 15516 15550 15551 15406 15432 15402 15540 15546 15405 15550 15539 15535 15543 15533 15419 15415 15403 15487 15429 15520 15450 15458 1586-98 14022 13636 1418 855 15557-75 15521-23 15393 15301 15245 15259 15241 15255 15255 15415 900 14411 14410 14460 14438 14431 14428 14439 14421 14780 14772 14762 14752 14728 14718 14749 14751 14761 14732 14742 14750 14752 14758 14762 14766 1519 14733 14737 14757 14759 14765 14769 14779 14728 14732 14742 14766 14786 1491 13870 13860 13850 13840 13830 13820 13810 13800 13790 13780 13770 13760 13750 13890 14785 14775 14765 14741 14733 14711 14705 13901 13881 13871 13861 13851 13841 13831 13821 13809 13801 13791 13781 13771 13769 13759 13749 14706 14716 14740 14748 14769 14739 14733 14727 14725 14705 1425 14716 15561 15566 15564 15569 15553 15557 15559 15563 15565 15574 15556 15549 15595 15598 15592 15586 15580 15575 15589 15583 15560 15562 15568 15541 15543 15555 1500 14741 1475 14779 14722 14791 14772 14772 14730 14757 14791 14792 14796 14778 14763 14743 14721 14762 14744 14726 14709 14751 14711 14722 14746 14755 14782 14766 14776 14760 14777 14758 14788 14752 14781 14727 14774 14755 14715 14749 14762 14738 14761 14740 14739 14729 14707 1215 14773 14743 14711 14757 14747 14783 14763 14787 14717 14779 14721 14737 14733 14767 14753 14807+ 1120+ 14820 15340 15372 15386 15360 15364 15392 15344 15356 15348 15376 15352 15380 15382 15368 15474 15464 15448 15460 15456 15442 15438 15468 15452 15478 15341 15441 15323 15431 15373 15305 15361 15365 15543 15501 15311 15539 15423 15445 15357 15481 15293 15495 15555 15513 15315 15501 15457 15345 15479 15427 15475 15491 15353 15517 15289 15369 15435 15273 15381 15319 15277 15273 15485 15349 15419 15377 15385 15505 15545-53 15449 15474 15474 15430 15414 15422 15410 15406 15426 15418 15434 15572 15531 15527 15523 1400 1420 15451 1522-26 14411 14560 15272 15274 15285 1450 1330-48 15733 15737 14234 14230 15164 15492 15496 1172 1182 14848 15486 15570 15572 15586 1445 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-1 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RS-3 RE-1 RE-2 RS-3 RS-1 RS-1 RS-1 RS-1 RS-1 RI-1 RS-2 RS-1 RS-1 RS-2 RS-1 RS-1 RS-1 RS-1 RS-2 RS-1 RS-2 RS-1 RS-1 RS-1 RS-1 RS-1 RS-1 RS-1 RS-1 P-1 RS-1 RS-1 RS-3 RM-1 RM-1 RM-1 RM-1 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 CR-1 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-2 RM-3 CR-1 RM-3 RM-3 RM-4 RM-4 RM-4 RM-4 RM-4 RM-1 CR-5 CR-3 CR-3 CR-3 CR-3 CR-5 CR-4 CR-4 CR-2 CR-1 CR-1 CR-2 CR-2 CR-2 CR-2 CR-2 CR-2 CR-1 CR-4 RM-2 CR-2 CR-2 CR-2 CR-2 CR-6 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-4 P-2 P-2 P-2 P-2 P-2 P-2 P-2 P-2 P-2 RM-3 P-3 P-1 P-3 RE-2 RE-2 RS-1 RS-3 P-1 CR-4 RS-2 RS-2 RS-2 RS-2 RS-2 RS-2 RM-4 RM-1 RI-1 RS-2 P-1 RI-1 RM-1 RM-2 P-1 P-1 P-1 P-1 P-1 P-1 RS-1 RM-2 RM-2 RI-2 RM-1 RS-1 RS-1 RS-3 RS-2 RS-2 RS-2 RS-2 RS-2 RS-2 RS-2 RS-2 RS-2 RS-3 P-1 RS-1 RM-2 RS-2 RS-2 P-1 RM-2 RS-3 RS-3 RS-3 P-2 RS-3 RS-2 RS-2 CR-4 RS-2 RS-2 RS-2 RS-2 RS-2 P-1 P-1 P-1 RS-2 RS-2 RS-2 RS-1 RS-1 CR-4 RS-1 RM-1 CD-2 CD-14 CD-4 CD-13 CD-8 CD-9 CD-24 CD-15 CD-23 CD-25 CD-28 CD-30 CD-31 CD-32 CD-5 CD-7 CD-35 CD-21 CD-11 CD-34 CD-18 CD-20 CD-6 CD-40 CD-36 CD-41 CD-19 CD-56 CD-54 CD-59 CD-17 CD-58 CD-46 CD-61 CD-64 CD-16 CD-1 CD-57 CD-3 CD-51 CD-66 CD-62 CD-29 CD-48 HIGH ST FINLAY CRT STOCKER CRT PACIFIC PL SUNSET DR FIR ST STAYTE RD PACIFIC AVE RUSSELL AVE BEST ST LANE JOHNSTON RD FOSTER ST LANE LANE LANE VIDAL ST CORY RD LANE BALSAM ST BREARLEY ST PROSPECT AVE LANE CYPRESS ST DOLPHIN ST COLDICUTT AVE TERRY RD ROYAL AVE OXENHAM AVE VISTA DR LANE MARTIN ST LANE LANE OXFORD ST MAPLE ST STEVENS ST MAGDALEN AVE MAGDALEN AVE LANE LANE LANE LANE PHOENIX ST VINE AVE VINE AVE LANE BEACHVIEW AVE WINTER ST LANE BLACKBURN CRES CHESTNUT ST MAGDALEN CRES LANE LANE WEST BEACH AVE ELM ST MCDONALD AVE LANE LANE LANE LANE LANE KEIL CRES LANE MALABAR CRES KYLE CRT BELLEVUE CRES FOSTER ST LANE LANE THRIFT AVE LANE LANE LANE LANE NORTH BLUFF RD MARINE DR MARINE DR MERKLIN ST LANE BUENA VISTA AVE BLACKBURN AVE LANE VINE AVE PROSPECT CRES SATURNA DR VINE AVE BEACHVIEW AVE LANE HARDIE AVE GORDON AVE LANE LANE UPPER ROPER AVE BAY ST SEMIAHMOO AVE VIDAL ST LANE BLACKBURN AVE JOHNSTON RD LANE KEIL ST STEVENS ST KENT ST MAPLE ST PROSPECT CRES STEVENS ST KENT ST LEE ST KEIL ST PARKER ST EWSON ST FIR ST MERKLIN ST BEST ST FIR ST CYPRESS ST PARKER PL HABGOOD ST GOGGS AVE SEYMOUR AVE GORDON AVE DUPREZ ST MAGDALEN AVE SUNSET DR ARCHIBALD RD VINE AVE PARK AVE WHEATLEY AVE LAUREL AVE TERRY RD LANE NORTH BLUFF RD NORTH BLUFF RD NORTH BLUFF RD BERGSTROM RD MALABAR AVE MALABAR AVE BERGSTROM RD LANCASTER ST NICHOL RD COLDICUTT AVE NORTH BLUFF RD MARINE DR BLACKBURN AVE BISHOP RD BISHOP RD MARINE DR SUNSET LANE MANN PARK CRES KERFOOT RD MAGDALEN AVE MARINE DR LANE MALABAR AVE SUNSET DR SUNSET DR BREARLEY ST KERFOOT RD LANE LANE MAGDALEN AVE RUSSELL AVE OXFORD ST OXFORD ST GOGGS AVE EVERALL ST NORTH BLUFF RD NORTH BLUFF RD RUSSELL AVE RUSSELL AVE FIR ST GEORGE ST GEORGE ST EVERALL ST EVERALL ST ROPER AVE ROPER AVE ROPER AVE ROPER AVE THRIFT AVE THRIFT AVE ROPER AVE THRIFT AVE BUENA VISTA AVE BUENA VISTA AVE PROSPECT AVE LANE LANE LANE OXENHAM AVE BLACKWOOD ST MARTIN ST MARTIN ST FOSTER ST JOHNSTON RD VICTORIA AVE COLUMBIA AVE LANE LANE LANE LANE LANE LANE LANE LANE COLUMBIA AVE VICTORIA AVE VICTORIA AVE PACIFIC AVE PACIFIC AVE SEMIAHMOO AVE JOHNSTON RD JOHNSTON RD CLIFF AVE CENTRE ST CENTRE ST DOLPHIN ST COLUMBIA AVE PACIFIC AVE PACIFIC AVE CLIFF AVE CLIFF AVE BUENA VISTA AVE BUENA VISTA AVE LEE ST PARKER ST KENT ST HABGOOD ST STEVENS ST STAYTE RD STAYTE RD HABGOOD ST LANE LANE FINLAY ST MOFFAT LANE LANE MAPLE ST PARKER ST STAYTE RD NORTH BLUFF RD NORTH BLUFF RD NORTH BLUFF RD FINLAY ST PROSPECT CRES ROPER AVE THRIFT AVE GOGGS AVE LEE ST LANE MAPLE ST HOSPITAL ST LANE LANE LANE LORNE CRT CATH CRT LANE LANE LANE NICHOL RD MARINE DR HIGH ST ANDERSON ST NORTH BLUFF RD OXENHAM MARTIN ST BLACKWOOD ST THRIFT AVE GOGGS AVE RUSSELL AVE FINLAY ST THRIFT AVE GOGGS AVE LEE ST THRIFT AVE KENT ST ROPER AVE BALSAM ST FINLAY ST ROYAL AVE SEMIAHMOO AVE FIR ST ROYAL AVE BUENA VISTA AVE ROYAL AVE COLUMBIA AVE MARINE DR FOSTER ST VICTORIA AVE LANE LANE EVERALL ST PROSPECT AVE ANDERSON ST MARINE DR BALSAM ST MARINE DR COLUMBIA AVE COLUMBIA AVE ASH ST ASH ST FINLAY ST MARINE DR MARINE DR VICTORIA AVE BUENA VISTA AVE LANE VICTORIA AVE BLACKWOOD LN NORTH BLUFF RD LANE LANE LANE LANE SUNSET LANE LANE LANE MARINE DR CARDINAL LN Zone map adopted by City Council on June 24, 2024 Schedule B - Bylaw No. 2506 The Corporation of the City of White Rock ­ Printed: Feb 3, 2026 100 0 100 200 300 400 50 Meters Zones: RS-1 SSMUH Residential Zone RS-2 SSMUH Residential Zone RS-3 (Small Lot, Hillside) SSMUH Residential Zone RE-1 SSMUH Estate Residential 1 Zone RE-2 SSMUH Estate Residential 2 Zone RI-1 (Infill 1) SSMUH Residential zone RI-2 (Infill 2) SSMUH Residential Zone RM-1 Low Density Multi-Unit Residential Zone EEEEE EEEEE EEEEE RM-2 Medium Density Multi-Unit Residential Zone RM-3 High Density Multi-Unit Residential Zone RM-4 Marine Drive Medium Density Multi-Unit Residential Zone CR-1 Town Centre Area Commercial / Residential Zone ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! CR-2 Lower Town Centre Area Commercial / Residential Zone CR-3 West Beach Business Area Commercial / Residential Zone CR-4 East Beach Business Area Commercial / Residential Zone CR-5 Neighbourhood Commercial Zone CR-6 Gas Bar/Convenience Commercial Zone P-1 Civic / Institutional Use Zone P-2 Church / Assembly Use Zone P-3 Community Care Facility (Low Density) Zone " " " " " " " " " " P-4 Community Care Facility (Medium Density) Zone C-D Comprehensive Development Zone Flood Plain Elevation 3.9 m 4.6 m Pier District Lot 595 6217.001 4.6 3.9 4.6 3.9 3.9 3.9 3.9 3.9