 "answer": "In the Town of Mono, Ontario, max height rear side: 1.8 metres (6 feet); max height front: 1.0 metres (3.3 feet); permit required: True; pool enclosure: Minimum 1.5 m height above finished grade; gate must be self-closing, self-latching on inside at or near top.. Source: Fence Bylaw (Bylaw 2020-36, as amended by 2025-42), verified 2026-08-28.",
 "municipality_id": "gx-001643",
 "municipality": "Mono",
 "status_type": "Town",
 "jurisdiction": "Ontario",
 "country": "CA",
 "topic": "fences",
 "label": "Fences & pool enclosures",
 "status": "found",
 "last_verified": "2026-08-28",
 "official_website": "http://www.townofmono.com/",
 "documents": [
  {
   "primary": true,
   "is_official": true,
   "title": "Fence Bylaw (Bylaw 2020-36, as amended by 2025-42)",
   "category": "fences",
   "document_type": "bylaw",
   "status": "adopted",
   "adopted_date": "2020-09-08",
   "document_url": "https://mono.civicweb.net/document/72214",
   "summary": "Regulates fence height and swimming pool enclosures in residential zones: maximum 1.8 m (6 ft) in a rear yard or interior side yard, but only 1.0 m (3.3 ft) in a front yard (open construction) and in an exterior side yard, and no more than 0.6 m (2 ft) within a corner-lot sight triangle. Pool enclosure fences must be at",
   "discovered_by": "on-newcats",
   "discovered_at": "2026-08-29",
   "capture_sha256": "b3a57b53f23efd1c5362a848e158e427e21b9b86cf405f77ff723100c4d03de1",
   "captured_at": "2026-08-29T14:33:34+00:00",
   "capture_http_status": 200,
   "snapshot_url": "https://pub-e61c5ee2a8704225bfa8de0c280e8a2c.r2.dev/bylaws/b3a57b53f23efd1c5362a848e158e427e21b9b86cf405f77ff723100c4d03de1.pdf",
   "link_dead": false,
   "facts": {
    "max_height_rear_side": "1.8 metres (6 feet)",
    "max_height_front": "1.0 metres (3.3 feet)",
    "permit_required": true,
    "pool_enclosure": "Minimum 1.5 m height above finished grade; gate must be self-closing, self-latching on inside at or near top.",
    "sight_triangle": "No fence greater than 0.6 metres (2 feet) in height along any point of a Sight Triangle; must be of open construction.",
    "prohibited_materials": "Barbed wire (except industrial zone ≥1.8 m); electric fences (except agricultural zone); sheet metal or corrugated metal panels; materials not usually intended for permanent fencing."
   },
   "fact_citations": {
    "max_height_rear_side": "s. 4.1 and s. 4.3.1",
    "max_height_front": "s. 4.2",
    "permit_required": "s. 5.2",
    "pool_enclosure": "s. 5.7(a), s. 5.12(d)",
    "sight_triangle": "s. 3.4",
    "prohibited_materials": "s. 3.1, s. 3.2, s. 3.6, s. 3.7"
   },
   "transcript_url": "/ca/on/mono/fences/text-b3a57b53f23e/",
   "transcript_quality": "exact"
  }
 ],
 "source": "https://govanswers.org/ca/on/mono/fences/"
}