| max height rear side | 1.83 m. (6.0 ft.) | "Higher than 1.83 m. (6.0 ft.) for that portion of the fence" |
| max height front | 0.91 m. (3.0 ft.) | "Higher than 0.91 m. (3.0 ft.) for that portion of the fence" |
| permit required | no | "less than 0.9 m. (3.0 ft.) in height in front yards and less than 1.8 m. (6.0 ft.)"; "Development Authority approval is required for fence construction at heights" |
| sight triangle | On any corner site, no wall, fence, shrub, trees, hedge or any object over 0.9 m (3.0 ft) above the lowest street grade within the sight triangle, formed by points on the site boundaries 3.05 m (10.0 ft) from the intersection. | "within the sight triangle a wall, fence, shrub, trees, hedge, or any object over 0.9 m. (3.0 ft.) in height" |
| prohibited materials | No electrical or barbed wire fences shall be permitted within the corporate boundaries of the Summer Village | s. 3.2(d) |
scout note
Fences capped at 1.83 m (6.0 ft) generally and 0.91 m (3.0 ft) closer to a front/flanking yard; corner-lot sight triangle bans any wall, fence, shrub, tree or hedge within the triangle formed by lines 6 m back from an intersection (Sec. 4.12, 4.16).