City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 1 of 47
CITY OF PORT COQUITLAM
FIRE AND EMERGENCY SERVICES BYLAW
Bylaw No. 4395
The Council of the Corporation of the City of Port Coquitlam enacts as follows:
CONTENTS
1.
PART 1 - INTRODUCTION
1.1
Citation
1.2
Minimum Competency Training Level
2.
PART 2 - DEFINITIONS
3.
PART 3 - INTERPRETATION AND GENERAL PROVISIONS
3.1
Words and Phrases
3.2
Conflict
3.3
Application
3.4
Duty of Care
4.
PART 4 - FIRE DEPARTMENT OPERATIONS
4.1
Fire Chief
4.2
Authority of Fire Chief
4.3
Conduct of Persons
4.4
Vacant and Fire-Damaged Property
4.5
Demolition
4.6
Commandeer Privately Owned Equipment
4.7
Safe Handling of Dangerous Goods
4.8
Tampering with Fire Protection Equipment
5.
PART 5 - PUBLIC SAFETY
5.1
Risk-based Compliance Monitoring System - Regular System of Inspections
5.2
Fire Chief, Members and Fire Inspectors
5.3
Emergency Fire Protection System Inspection, Testing and Maintenance
5.4
Falsify Records and Reports
5.5
Premises Evacuation
5.6
Fire Watch
5.7
Review of Building Construction Plans
5.8
Alternate Solutions to Prescribed Code
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 2 of 47
5.9
Technical Assistance
5.10
Code Analysis
5.11
Construction Fire Safety Planning
5.12
Fire Safety Plan/Emergency Planning
5.13
Occupancy Contact Requirements
5.14
Operating Permit
6.
PART 6 - REGULATION OF FIRE HAZARDS
6.1
Fire Hazards
6.2
Disposal of Material
6.3
Garbage and Recycling Containers
6.4
Combustible Waste Near Buildings
6.5
Explosion or Potential Explosion - Hazardous Substances
6.6
Open Air Fires
6.7
Forest Fire Danger
6.8
Delegation of Authority - Fire Risk in Forest/Woodlands
6.9
Compliance with Orders
6.10
Right to Enter
6.11
Firework Regulations
6.12
Fuel Dispensing Stations / Underground Tanks
7.
PART 7 - INSPECTION OF PREMISES AND FIRE PROTECTION EQUIPMENT
7.1
Adoption of Fire Code
7.2
Fire Department Access
7.3
Addressing of Occupancies
7.4
Fire Department Lock Cylinders
7.5
Fire Doors
7.6
Exit Signs
7.7
Exit Systems
7.8
Location of Fire Alarm Annunciator Panel
7.9
Fire Alarm System Monitoring and Certificate Posting
7.10
Automatic Sprinkler Systems Hydraulic Data Plate
7.11
Fire Department Connections
7.12
Fire Pumps & Private Fire Hydrants for Fire Protection
7.13
Special Fire Suppression Systems
7.14
Commercial Cooking Equipment
7.15
In Building Emergency Responder Communication Enhancement Systems
7.16
Enclosed Storage Garages for Vehicles
7.17
Shipping Containers
7.18
Construction and Demolition Sites
7.19
New Fire Hydrants
7.20
Flammable and Combustible Liquids
7.21
Spray Coating Using Flammable or Combustible Materials
7.22
Mobile Food Vendors
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 3 of 47
7.23
Special Events
7.24
Integrated Fire Protection and Life Safety System Testing
8.
PART 8 - COST RECOVERY AND FEES
8.1
Fees for Permits and Services
8.2
Special Inspections, Follow-up and Re-inspections
8.3
Fire Investigations
8.4
Comfort Letter Requests
8.5
Damaged or Contaminated Vehicles or Equipment
8.6
Extraordinary Charges
8.7
Development Review Fees
8.8
Occupant Load
8.9
Event Approval
8.10
Filming Special Effects and Pyrotechnics
8.11
Notification of Fire and Sprinkler Alarm Testing
8.12
False Alarms and Nuisance Alarms
9.
PART 9 - PERMITS
9.1
Issuance of Permit
9.2
Conditions of Permit
9.3
Permit Form
10. PART 10 - ENFORCEMENT
10.1
Orders
10.2
Standard of Work
10.3
Rejection of Work
10.4
Form of Order
10.5
Serving and Compliance with Order
10.6
Cost Recovery
10.7
Compensation to Municipality
10.8
Designation of the Bylaw
10.9
Obstruction
10.10
Default
10.11
Offences and Penalties
11. PART 11 - MISCELLANEOUS
11.1
Severability
11.2
Repeal
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 4 of 47
1.
PART 1 - INTRODUCTION
1.1
Citation
1.1.1 This Bylaw is cited as "Fire and Emergency Services Bylaw, 2025,
No. 4395".
1.2
Minimum Competency Training Level
1.2.1 The City of Port Coquitlam Fire and Emergency Services is a Full-
Service Operation according to the Structure Firefighters Competency
and Training Standards, prepared by the Officer of the Fire
Commissioner of British Columbia, pursuant to paragraph 4(1)(d) of the
Fire Safety Act.
2.
PART 2 - DEFINITIONS
In this Bylaw, unless the context otherwise requires:
"Alternate solution" means a proposed alternate design solution for a building that is
produced by a registered professional to comply with the requirements of the Building
Code, Fire Code or other statutory or regulatory requirements.
"Area of refuge" means a space that facilitates a safe delay in egress, is sufficiently
protected from fire conditions developing in the floor area, and provides direct access to
an exit or firefighters elevator.
"Authority having jurisdiction" means the governmental agency having regulatory
authority over a specific aspect of a project.
"Building" means any structure used or intended for supporting or sheltering any
use or occupancy as defined by the Fire Code.
"Building Code" means the current edition of the British Columbia Building Code as
adopted by the Minister responsible under provincial legislation, as amended or
replaced.
"Building permit" has the meaning prescribed in the building and plumbing bylaw.
"Bylaw" laws passed by municipal council to exercise their statutory authority.
"Bylaw enforcement officer" means a Royal Canadian Mounted Police officer, a member,
or any official or employee of the municipality whose designated duties include the
enforcement of bylaws within the municipality;
"Bylaw Notice Enforcement Bylaw" means the "Bylaw Notice Enforcement Bylaw, 2013,
No. 3814", as amended or replaced.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 5 of 47
"Certified fire protection technician" means a person certified by ASTTBC (Applied
Science Technologists and Technicians of British Columbia) to inspect and test fire
protection equipment, or an equivalent acceptable to the Fire Chief.
"City" means the Corporation of the City of Port Coquitlam or the geographic area within
the municipal boundaries of the city, as the context requires.
"Combustible" refers to the chemical reaction that is demonstrated when matter
(substance, product) bursts into flame, through combustion or being exposed to fire.
Combustion is a self- sustaining chemical reaction yielding energy or products that cause
further reactions of the same kind.
"Community Charter" means the Community Charter, SBC 2003, c. 26, as amended or
replaced.
"Construction fire safety plan" means a plan meeting Fire Department Guidelines for
construction fire safety submitted for acceptance in accordance with the Fire Code and
Building Code.
"CSA/ULC" means the Canadian Standards Association/Underwriters Laboratory of
Canada.
"Dangerous goods" means those products or substances which are regulated by the
Transportation of Dangerous Goods Act, SC 1992, c. 34 and its Regulations, as
amended or replaced.
"Enclosed storage garage" means a structure built within a common area of a storage
garage as defined in the Building Code, where the interior space can be fully viewed
from the exterior through a gated or mesh overhead door.
"Explosion" means a rapid release of energy that may or may not be preceded or
followed by a fire which produces a pressure wave or shock wave in air and is usually
accompanied by a loud noise.
"False alarm" means the activation of a fire alarm system, regardless of how caused, as
a result of which Fire Department resources and services are provided and a member
does not find any evidence of fire, fire damage or smoke.
"Fees and Charges Bylaw" means the "Fees and Charges Bylaw, 2024, No. 4390", as
amended or replaced.
"Fire alarm system" means a device or devices installed on or in real property and
designed to issue a warning of a fire by activating an audible alarm signal and/or alerting
a monitoring service, but does not include local smoke alarms that are intended to alert
only the occupants of a single-family dwelling unit in which it is installed.
"Fire Chief" means the person appointed as the Chief of the Fire Department of the
municipality or an authorized designate.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 6 of 47
"Fire Code" means the BC Fire Code adopted as Regulation 263/2012 to the Fire Safety
Act;
"Fire Commissioner" means the person appointed as the Fire Commissioner for British
Columbia pursuant to the Fire Safety Act.
"Fire Department" means the department that provides municipal emergency and non-
emergency fire and rescue services.
"Fire Department access route" means an approved route designed to Building Code
and municipal standards that the Fire Department uses to respond to a building or
occupancy.
"Fire Department connection" means a 4-inch Storz connection through which the Fire
Department pumps supplemental water into a sprinkler or standpipe system.
"Fire Department lock cylinder" means a 1-1/2 inch or 2-1/2 flush mount Abloy lock
cylinder, which contains access keys to, but not limited to, front entrance, mechanical
room, service room, electrical room, elevator room, fire safety plan box, and roof access.
"Fire Department response point" means an identified primary response point on a
property where the Fire Department would access and operate the site-specific fire
protection equipment and life safety systems during an incident response.
"Fire Inspector" means an individual designated in writing as a fire inspector pursuant to
this Bylaw and Section 8 of the Fire Safety Act.
"Fire Investigator" means an individual designated in writing as a fire investigator
pursuant to this Bylaw and Section 23 of the Fire Safety Act.
"Fire Officer" means Fire Department personnel who have achieved the rank of
Lieutenant or Captain.
"Fire protection equipment" means, but is not limited to, fire alarm systems, automatic
sprinkler systems, special extinguisher systems, portable fire extinguishers, fire hydrants,
water supplies for fire protection, standpipe and hose systems, fixed pipe fire
suppression systems in commercial cooking exhaust systems, smoke control measures
and emergency power installations.
"Fire safety plan" means a documented plan outlining fire safety measures, procedures
and equipment as required in accordance with the Fire Code and the Building Code.
"Fire separation" has the meaning prescribed in the Building Code.
"Fire Safety Act" means the Fire Safety Act, S.B.C., c.19, as amended or replaced.
"Fire watch" is a temporary measure intended to ensure continuous and systematic
surveillance of a building or portion thereof by an assigned fire watch person, for the
purposes of identifying and controlling fire hazards, detecting early signs of fire, raising
an alarm for fire and notifying occupiers and the Fire Department.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 7 of 47
"Flammable and combustible liquid" means a liquid classified as flammable or
combustible in the Fire Code.
"Hazardous materials" means products, materials, or substances that are considered
dangerous goods.
"Highway" includes a street, road, lane, bridge, viaduct and any other way open to public
use, other than a private right of way on private property.
"Hot works" means processes that involve open flames or that produce heat or sparks,
including but not limited to cutting, welding, soldering, brazing, grinding, adhesive
bonding, roofing operations, thermal spraying and thawing pipes.
"Incident response" means aid provided in response to fires, explosions, medical
emergencies, earthquakes or other natural disasters, escape of dangerous goods, rail or
marine incidents, motor vehicle or other accidents and other circumstances to which the
Fire Department responds or attends.
"Integrated test" means a test of the interconnections between fire protection and life
safety systems as per CAN/ULC-S1001 "Integrated Systems Testing of Fire Protection
and life safety systems".
"Integrated testing coordinator" means a person, firm, corporation, or organization
responsible for developing and implementing the integrated testing plan and who are
knowledgeable and experienced in the design, installation and operation of the fire
protection equipment included in the integrated testing plan. The integrated testing
coordinator is to be certified by ULC as an Integrated Systems Testing Service Provider
or equivalent acceptable to the Fire Chief.
"Integrated testing plan" means a written project-specific document, prepared by the
integrated testing coordinator, outlining the required tests and necessary functional
results to conduct integrated fire protection and life safety system testing.
"Integrated testing report" means a written project-specific document, prepared by the
integrated testing coordinator, documenting the implementation of the integrated testing
plan.
"Life safety systems" means components or combinations of equipment of fire alarm
systems, sprinkler systems, special suppression systems, means of egress, and other
emergency equipment as regulated by the Fire Code, its regulations and this Bylaw.
"Member" means any employee of the Fire Department.
"Metro Vancouver Air Quality Bylaw" means the "Metro Vancouver Air Quality Management
Bylaw No. 1082, 2008" as amended or replaced.
"Mobile food vendor" means a person carrying on a business of preparing food and
offering it for sale from a vehicle and includes, but is not limited to, vehicles, trailers and
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 8 of 47
carts with cooking equipment that produce smoke or grease laden vapors in a confined
compartment.
"Municipal council" or "council" means the elected council of the municipality.
"Municipal engineer" means the General Manager - Engineering, Parks and Environment
or a person designated to act in his/her place.
"Municipality" means the Corporation of the City of Port Coquitlam or the geographic area
within the municipal boundaries, as the context requires.
"NFPA" means the National Fire Protection Association.
"Nuisance alarms" means activation of a fire alarm system regardless of how it is
caused necessitating a fire response where a fire or emergency does not exist.
"Occupancy" means the use or intended use of a building or part thereof for the
shelter or support of persons, animals or property as defined in Fire Code.
"Occupier" means the owner, tenant, lessee, agent or other person who has the right of
access to and responsibility for any building or premises.
"Order" means an order, direction, remedial action, approval, decision, determination, or
permit made under this Bylaw and/or the Fire Code by the Fire Chief, fire inspector or a
member.
"Owner" has the meaning prescribed in the Community Charter, SBC 2003, c. 26, as
amended or replaced.
"Owner's authorized agent" means the person or persons appointed by the owner to
make decisions in relation to the owner's property in their absence.
"Permit" means a permit issued by the Fire Chief or any member pursuant to this Bylaw.
"Protection of adjacent buildings report" means a report that is prepared by a registered
professional that is submitted with the construction fire safety plan, that identifies the
methods that are required to implement to protect adjacent buildings during the
appropriate stages of construction.
"Registered professional" means a person who is registered or licensed to practice as an
architect under the Architects Act, RSBC 1996, c. 17, as amended or replaced, a person
who is registered or licensed to practice as a professional engineer under the Professional
Governance Act, SBC 2018, c. 47, as amended or replaced, or other professionals as
approved by the Fire Chief.
"Safety Standards Act" means Technical Safety BC general requirements for regulated
work performed by contractors.
"Shipping container" means a large standardized container designed and built for
intermodal freight transport.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 9 of 47
"Special event" means any exhibit, market, outdoor concert, fair display, trade show,
vehicle display or outdoor event or other similar event.
"Special fire suppression system" includes low, medium and high expansion foam
systems, foam-water, carbon dioxide, dry chemical and wet chemical systems.
"Storage garage" as defined by the BC Building Code means a building or part thereof
intended primarily for the storage or parking of motor vehicles and containing no
provision for the repair or servicing of such vehicles, but do not include entrances at
which vehicles stop for a short time beneath an unenclosed canopy to pick up and drop
off passengers. For certainty, storage garages may also contain space for parking or
storing other vehicles, including, but not limited to bicycles and boats.
"Traffic control plan" means a plan describing the manner in which the individual granted
the permit will manage vehicle, bicycle, and pedestrian traffic along affected streets, all
while maintaining the ability for emergency vehicles to gain access unimpeded.
"ULC Certificate" is a certificate issued under the Certificate Service of Underwriters
Laboratories of Canada.
"Water supply system" means the system for supplying water for fire protection
purposes and includes, but is not limited to, fire hydrants, fire pumps, water towers and
tanks, Fire Department connections and any other hose connections necessary for Fire
Department operations.
3.
PART 3 - INTERPRETATION AND GENERAL PROVISIONS
3.1
Words and Phrases
3.1.1 Unless specifically defined herein, words and phrases used in this Bylaw
shall be construed in accordance with the meanings assigned to them by
the Fire Safety Act, the Building Code, or the Fire Code, all as may be
amended or replaced, as the context and circumstances require.
3.2
Conflict
3.2.1 In the event of a conflict, discrepancy, variation or inconsistency between
any provisions of this Bylaw and the Fire Safety Act, the Fire Code or the
Building Code, the provisions of the Fire Safety Act, the Fire Code or the
Building Code, as the case may be, shall prevail over the provisions of
this Bylaw to the extent of any conflict, discrepancy, variation or
inconsistency.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 10 of 47
3.3
Application
3.3.1 The provisions of this Bylaw apply to all buildings, structures, premises
and conditions within the municipality and, for certainty, apply to both
existing buildings and buildings under construction.
3.4
Duty of Care
3.4.1 This Bylaw does not create any duty of care whatsoever on the
municipality or its elected officials, officers, employees or agents in
respect of enforcement or failure to enforce this Bylaw. Neither the
failure to administer or enforce, nor the incomplete or inadequate
administration or enforcement of this Bylaw or inspections made by the
Fire Chief or fire inspector gives rise to a cause of action in favour of any
person.
4.
PART 4 - FIRE DEPARTMENT OPERATIONS
4.1
Fire Chief
4.1.1 The Fire Chief is appointed by the Chief Administrative Officer.
4.1.2 Any references to the Fire Chief in this Bylaw shall include a reference to
any person duly authorized by the Fire Chief to exercise any of the Fire
Chief's powers or to carry out any of the Fire Chief's duties under this
Bylaw.
4.1.3 The municipal council hereby delegates to the Fire Chief the power to
administer and enforce the Fire Safety Act, the Fire Code and any
statute or regulation thereunder.
4.2
Authority of Fire Chief
4.2.1 The Fire Chief is authorized to:
a)
Manage, control, supervise and enforce the activities of the Fire
Department and its members;
b)
Appoint or authorize members to exercise any of the Fire Chief's
powers on such terms and conditions as the Fire Chief considers
appropriate and revoke any such appointment or authorization;
c)
Carry out all other actions the Fire Chief is authorized to perform
pursuant to this Bylaw, the Fire Code, the Fire Safety Act and any
statute or regulation;
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 11 of 47
d)
Designate, in writing, persons or classes of persons as fire
inspectors to conduct fire safety inspections provided that any
such designated individual meets the applicable standards
established by the Fire Commissioner in accordance with the Fire
Safety Act;
e)
Designate, in writing, persons or classes of persons as fire
investigators to conduct fire investigations provided that any such
designated individual meets the applicable standards established
by the Fire Commissioner in accordance with the Fire Safety Act;
and
f)
Make such orders as the Fire Chief deems necessary with
respect to any of the matters referred to in this Bylaw.
4.2.2 The Fire Chief, fire inspectors, fire investigators, and every member
authorized by the Fire Chief is authorized to take all measures
considered necessary to:
a)
Prevent, suppress, control, and extinguish fires;
b)
Provide incident response;
c)
Provide fire inspection and fire investigation services;
d)
Provide Fire Code review for buildings;
e)
Protect life and property;
f)
Have the care, custody and control of all Fire Department
apparatus, equipment and buildings; and
g)
Provide emergency preparedness programs.
4.2.3 No apparatus of the Fire Department shall be used beyond the
jurisdictional boundaries of the municipality without the permission of the
Fire Chief.
4.3
Conduct of Persons
4.3.1 A person must not:
a)
Impede in any way any member in the execution of their duties,
including but not limited to:
(i)
Providing an incident response;
(ii)
Investigating a fire scene;
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 12 of 47
(iii)
Investigating a building to determine the cause of
activation of a fire alarm system, sprinkler system or other
fire or life safety system;
(iv)
Investigation of a complaint of a fire hazard; or
(v)
Conducting a fire safety inspection as required by the Fire
Safety Act or this Bylaw.
b)
Enter an incident area without the permission of the Fire Chief
except for those duty authorized by the Fire Chief or any member
in charge at an incident;
c)
Drive a vehicle over any fire hose;
d)
Falsely represent themselves as a member or wear or display the
Fire Department badge, cap, button, insignia, or other
paraphernalia for the purpose of such false representation.
4.3.2 The Fire Chief or any member designated by the Fire Chief to be in
charge at an incident may order any person at or near an incident
response to render reasonable assistance to mitigate an incident.
4.4
Vacant and Fire-Damaged Property
4.4.1 The owner(s) or owner's authorized agent of a vacant or fire-damaged
building must promptly take all steps necessary to secure the building
against the entry of unauthorized persons, including, but not limited to,
guarding the building and securing all openings to the building and land
surrounding the building, if so ordered by the Fire Chief, to the
satisfaction of the Fire Chief. In such events, the owner(s) or owner's
authorized agent or occupier of the property must pay the cost to secure
the building and land surrounding the building.
4.4.2 The Fire Chief or any member has the authority, at all times, by day or
night, to provide a post-incident watch for a period of time deemed
necessary to secure the vacant or fire damaged building and any
necessary surrounding land against further incident. The Fire Chief can
engage the services of a security company or security person to
maintain a fire watch for the building and surrounding land, to perform
site security or to secure vacant or fire damaged building and any
necessary surrounding land at the expense of the owner(s) or owner's
authorized agent or occupier and any such measures taken are
considered services provided in relation to lands or improvements.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 13 of 47
4.5
Demolition
4.5.1 The Fire Chief and any member authorized by the Fire Chief may order
the damage, destruction or demolition of any building, part of a building,
structure, equipment or other private property as may be necessary to
extinguish, suppress or prevent the spread of fire or prevent the potential
collapse of a building resulting from an incident response.
4.5.2 None of the municipality, the Fire Department or any of their elected or
appointed officials, officers, employees or members is obligated to
restore or pay compensation for property damaged, destroyed or
demolished pursuant to section 4.5.1.
4.5.3 If the Fire Chief or a member arranges for damage, destruction or
demolition pursuant to sections 4.5.1, the owner(s) or owner's authorized
agent of the property subject to such services must pay to the
municipality the hourly rate of equipment and staffing cost of each
member for the actual time the member and equipment attended at the
site, plus any other expenses incurred by the Fire Department in relation
to the incident response in accordance of Schedule G of the Fees and
Charges Bylaw, No. 4390.
4.6
Commandeer Privately Owned Equipment
4.6.1 The Fire Chief or any member in charge at an incident response has the
authority to commandeer privately owned equipment which the Fire
Chief or members considers necessary to deal with the incident
response and the owner of such equipment will be compensated in
accordance with standard industry rates.
4.7
Safe Handling of Dangerous Goods
4.7.1 Every owner(s) or owner's authorized agent, carrier, agency,
organization or other person having responsibility for the transport,
storage or use of dangerous goods is responsible, at their own cost, for
the clean-up and safe disposal of all such dangerous goods arising from
any incident and where the person fails to clean up and/or dispose of
such dangerous goods adequately (as determined by the Fire Chief).
Such person must pay the actual costs and expenses incurred by the
Fire Department or its contractors in mitigating the incident involving
dangerous goods and pay the actual costs and expenses incurred to
clean up and safely dispose of the dangerous goods.
4.8
Tampering with Fire Protection Equipment
4.8.1 A person must not:
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 14 of 47
a)
Tamper with, or damage in any way any fire protection equipment
of any kind except as may be required for maintenance and
service; or
b)
Reset or silence a fire alarm system until authorized by the Fire
Chief.
5.
PART 5 - PUBLIC SAFETY
5.1
Risk-based Compliance Monitoring System - Regular System of Inspections
5.1.1 The Fire Chief is authorized and required to implement a risk-based
compliance monitoring system for public buildings consisting of fire
safety inspections and fire safety assessments as required by the Fire
Safety Act to ensure that owners of public buildings comply with the Fire
Safety Act and its regulations.
5.2
Fire Chief, Members and Fire Inspectors
5.2.1 Fire inspectors are authorized to enforce rules, regulations and policies
for the administration and operation of the Fire Department as directed
by the Fire Chief.
5.2.2 The Fire Chief, members, and fire inspectors are authorized to:
a)
Enter on property and inspect premises for conditions that may
cause a fire, increase the dangers of a fire or increase the
dangers to persons or property from a fire;
b)
Take measures to prevent and suppress fires, including the
demolition of buildings or other structures and removal or cutting
of natural or planted vegetation to prevent the spreading of fires;
c)
Order an owner(s) or owner's authorized agent to undertake any
actions to remove or reduce anything or condition that is a fire
hazard that increases the danger of fire;
d)
Provide incident response;
e)
Exercise any of the powers conferred to a Fire Chief or fire
inspector under the Fire Safety Act;
f)
Create and enforce rules, orders, regulations and policies
respecting fire prevention and suppression and the protection of
life, property and the environment;
g)
Inquire into, investigate and record the causes of fires in the
municipality;
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 15 of 47
h)
Collect and disseminate information in regard to fires in the
municipality;
i)
Investigate and hold inquiries into fires in the municipality;
j)
Study methods of fire prevention; and/or
k)
Provide advice and make recommendations to council, other
officers and employees of the municipality and the public in
relation to:
(i)
The installation or maintenance of fire protection
equipment; and
(ii)
Fire prevention generally.
5.3
Emergency Fire Protection System Inspection, Testing and Maintenance
5.3.1 Every occupier, owner(s) or owner's authorized agent must undertake
required actions to correct violations within the time specified in a report,
notice or order.
5.3.2 The municipality may undertake required actions to correct violations,
but is not obligated to carry out such work. The Fire Chief has the
authority, at all times, by day or night to hire or engage the services of a
fire protection service company to repair, inspect or maintain fire
protection equipment that may require repair, inspection or maintenance
and the costs are to be paid by the occupier, owner(s) or owner's
authorized agent. Any such measures taken are considered services
provided in relation to lands or improvements.
5.3.3 Every person who is required under any provision of the Fire Code to
perform or cause to be performed any inspection or test of fire protection
equipment, whether annually or otherwise, must ensure that:
a)
The inspection or test is performed by a certified fire protection
technician and in accordance with the Fire Code; and
b)
The inspection or test is recorded or the fire protection equipment
tagged or labelled in accordance with the Fire Code and any
regulations or bylaws under the Professional Governance Act,
SBC 2018, c. 47, as amended or replaced, and acceptable to the
authority having jurisdiction.
5.3.4 All fire protection equipment in buildings with two or more strata
corporations must be serviced by a common certified fire protection
technician.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 16 of 47
5.4
Falsify Records and Reports
5.4.1 A person must not withhold or falsify any information required by any
member, nor refuse to assist a member in their responsibilities under this
Bylaw.
5.5
Premises Evacuation
5.5.1 Upon activation of a fire alarm system, the owner(s) or owner's
authorized agent and all occupiers must exit the building, if possible, or
remain inside the suite, unit, building or area of refuge as directed in the
fire safety plan for the building or comply with the order(s) or directions of
the Fire Chief or member, until the Fire Chief or officer in charge
authorizes re-entry into the building or premises and/or the re-setting of
the fire protection equipment and/or the all clear is given.
5.6
Fire Watch
5.6.1 A fire watch is required:
a)
When any life safety system is taken out of service, requires
servicing, has been silenced or shut down, or as otherwise
directed by a member; and
b)
When doing hot works or as required in a special permit or fire
safety plan.
5.6.2 When a fire watch has been initiated, the person assigned to perform the
fire watch must have the means and ability to comply with all of the
following:
a)
Communicate effectively with building occupants and emergency
personnel;
b)
Notify the Fire Department in the event of a fire emergency;
c)
Notify the building occupiers in the event of a fire emergency;
d)
Ensure that all public areas on all floors of the building are
patrolled at least once every 15 minutes;
e)
Maintain a logbook on the premises to be immediately available
for inspection by the Fire Chief;
f)
Relay any special order(s) or pertinent information to any person
relieving the owner of the fire watch duty;
g)
Remain on duty until relieved by another assigned fire watch
person that complies with this section; and
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 17 of 47
h)
Must not have other assigned duties that negate their ability to
perform the fire watch as detailed in this section 5.6.2.
5.6.3 The fire watch must be maintained until Fire Department personnel have
been notified that the life safety systems are back in service.
5.7
Review of Building Construction Plans
5.7.1 The Fire Chief or any member is authorized to review plans and inspect
the construction of all new buildings and structures, other than single
family dwellings, in order to establish that the fire protection facilities and
equipment in the building comply with the Fire Code and all other
applicable fire-related regulations, codes and standards.
5.8
Alternate Solutions to Prescribed Code
5.8.1 A design solution from a registered professional for an alternate solution
that is approved by the city is subject to the following requirements:
a)
Alternate solutions must be functionally demonstrated before
occupancy of a building is authorized by the Fire Chief;
b)
Alternate solutions must be serviced and maintained in
accordance with applicable codes and standards as represented
by the system components in Part 7 of this Bylaw and must be
operational at all times;
c)
A copy of the alternate solutions and the service and
maintenance requirements must be included in the fire safety
plan;
d)
Alternate solutions that include interconnected components of
property and/or multiple property strata(s) must be serviced by a
common fire protection service company in order to maintain the
operational function of the alternate solution; and
e)
A functional demonstration of an alternate solution may be
requested by the Fire Department at any time in which case the
owner of the property must pay the applicable fee prescribed in
Schedule G of the Fees and Charges Bylaw, No. 4390, for the
attendance and review by the Fire Department.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 18 of 47
5.9
Technical Assistance
5.9.1 If, in the opinion of the Fire Chief, a design proposal for a building
requires an independent review, the Fire Chief is authorized, at the
owner's expense, to retain the services of a registered professional with
the expertise in the proposed design to review the design proposal and
provide an evaluation, including making recommendations for changes
to the proposed design, operation, process, or new technology. The cost
for the registered professional must be paid by the building owner upon
receipt of an invoice from the municipality.
5.10
Code Analysis
5.10.1 The Fire Chief may require an owner(s) or owner's authorized agent of a
building to provide, at the owner's expense, confirmation from a
registered professional that the building or use within the building is
adequately protected against fire hazards in conformance with the
Building Code, the Fire Code and any associated regulations.
5.10.2 If required by the Fire Chief, the owner's registered professional must
provide an evaluation of the building for use and, where applicable,
recommended upgrades to the building or life safety systems.
5.11
Construction Fire Safety Planning
5.11.1 An owner(s) or owner's authorized agent must at the time of building
permit application submit a construction fire safety plan for review and
acceptance in a form and diagram template acceptable to the Fire Chief
together with the construction fire safety plan review fee prescribed in
Schedule G of the Fees and Charges Bylaw, No. 4390.
5.11.2 The owner(s) or owner's authorized agent must ensure that the
construction fire safety plan is kept up to date, including but not limited
to:
a)
The emergency contact information; and
b)
The changing hazards or risks at the construction site and
mitigation strategies.
5.11.3 The owner(s) or owner's authorized agent must:
a)
Submit updates to the construction fire safety plan to the Fire
Department for review and acceptance; and
b)
Ensure that the construction fire safety plan includes a protection
of adjacent buildings report per the Fire Code, prepared by a
registered professional in accordance with the Fire Code, to
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 19 of 47
identify risks to adjacent properties and the mitigation methods
that will be used on the construction site.
5.12
Fire Safety Plan/Emergency Planning
5.12.1 The owner(s) or owner's authorized agent must provide fire emergency
planning and procedures conforming to the Fire Code as well as multi-
tenanted commercial and multi-tenanted industrial buildings.
5.12.2 The owner(s) or owner's authorized agent must:
a)
Where required to have a fire safety plan per the Fire Code or
this Bylaw, submit the plan for review and acceptance in a form
and diagram template acceptable to the Fire Chief, together with
the fire safety plan review fee prescribed in Schedule G of the
Fees and Charges Bylaw, No. 4390;
b)
Submit a pre-incident plan (PIP) in a form prescribed and
accepted by the Fire Chief;
c)
Review the approved fire safety plans at least every twelve (12)
months to ensure that the emergency contact information is up to
date;
d)
Forward any changes in the use, design or life safety systems to
the Fire Department for review and acceptance; and
e)
Ensure that every fire safety plan is placed in a locked cabinet
located at the Fire Department response point or other location
acceptable to the Fire Chief.
5.13
Occupancy Contact Requirements
5.13.1 The owner(s) or owner's authorized agent of a building, must:
a)
Provide three (3) twenty-four-hour emergency contact name and
phone numbers for persons able to respond to a phone call and
attend the premises immediately;
b)
Have full access to the entire building for which they have
responsibility;
c)
Be available to attend, enter and secure the premises at all times
of day and night to respond to an incident response;
d)
Be able to take responsibility for the building from the member on
competition of an incident response;
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 20 of 47
e)
Attend all alarms at the building within forty-five (45) minutes of
being requested by the Fire Department; and
f)
Secure the premises within a reasonable time or when directed to
do so by the Fire Chief.
5.14
Operating Permit
5.14.1 The owner(s) or owner's authorized agent of a building that has a fire
alarm system must have an operating permit as per the Safety
Standards Act.
5.14.2 The owner(s) or owner's authorized agent must ensure that individuals
who do regulated work under the permit maintain current knowledge of
the Safety Standards Act, relevant regulations, directives, safety orders
and any other relevant material as per the Safety Standards Act.
5.14.3 A copy of the permit shall be posted in a conspicuous place at the
building and shall not be removed as per BC Electrical Code Regulation.
6.
PART 6 - REGULATION OF FIRE HAZARDS
6.1
Fire Hazards
6.1.1 The Fire Chief may, at all reasonable hours enter any premises to
inspect them and ascertain whether;
a)
A fire hazard exists on the premises;
b)
The premises are in such a state of disrepair that a fire starting in
them might spread rapidly to endanger life or other property;
c)
The premises are so used or occupied that fire would endanger
life or property; or
d)
Combustible or explosive material is kept or other flammable
conditions exist on the premises so as to endanger life or
property.
6.1.2 A person must not cause a fire hazard.
6.2
Disposal of Material
6.2.1 A person must not:
a)
Dispose of any liquid, flammable substance or hazardous
substance in any manner that could cause a fire hazard;
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 21 of 47
b)
Dispose of any explosive, flammable and combustible liquid,
hazardous material or any liquid of a petro-chemical nature
without written permission from the Fire Chief;
c)
Dispose of any lighted or extinguished cigarette, cigar, match,
smoking or vaporizing equipment or other burning substance
except into a garbage container or other container designed for
such disposal; or
d)
Dispose of yard waste or trimmings, trees, branches or any other
materials which could cause a fire hazard.
6.3
Garbage and Recycling Containers
6.3.1 Containers for the disposal, removal or storage of garbage, refuse,
building debris, paper, recyclable materials or combustible material with
any dimension greater than 1.5 metres must comply with the following
requirements:
a)
Be constructed of non-combustible material;
b)
Be equipped with a non-combustible tight-fitting lid;
c)
Have lids kept closed at all times, unless otherwise approved by
the Fire Chief;
d)
If the container is located outside of a building, it must not be
located within 5 metres of any combustible building or structure,
unless stored within a non-combustible structure or in a location
approved by the Fire Chief; and
e)
If the container is located outside of a building and is a non-
combustible container with a self-closing lid and no hold-open
devices, it must be located no closer than 1 metre from any
combustible building or structure,
6.3.2 Combustible containers with dimensions greater than 1.5 metres are
permitted to be stored in storage rooms specifically designed for the
storage of garbage and recycling.
6.4
Combustible Waste Near Buildings
6.4.1 An owner(s) or owner's authorized agent must not allow combustible
waste materials or garbage to remain adjacent to such building for longer
than forty-eight (48) hours.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 22 of 47
6.4.2 The municipality may facilitate or cause the removal of combustible
materials from, in or around buildings and in such event, the owner of the
property must pay the cost of such removal. Any such measures are
considered services provided in relation to lands or improvements.
6.5
Explosion or Potential Explosion - Hazardous Substances
6.5.1 It is the duty of the owner(s) or owner's authorized agent of any property,
building, premises, motor vehicle, vessel or railway rolling stock, to
immediately report the potential for or the occurrence of any explosion,
discharge, emission, escape or spill of a hazardous materials to the Fire
Chief.
6.6
Open Air Fires
6.6.1 Restrictions:
a)
Except as specifically permitted in this Bylaw, a person must not
light, ignite, start or cause to be lighted, ignited or started, a fire of
any kind whatsoever in the open air, including airborne fire
holding devices not under the control of the user (e.g. wish
lanterns);
b)
Burning for land clearing and/or construction purposes is
prohibited;
c)
All exterior solid fuel-fired appliances or devices are prohibited,
including pizza ovens and outdoor fireplaces that were built
without a municipal building permit.
d)
Existing wood-fired pizza ovens and outdoor fireplaces that were
constructed and inspected through a municipal building permit
may be permitted to operate, but must be in compliance with the
Metro Vancouver Air Quality Bylaw.
6.6.2 Exemptions:
a)
The Fire Chief may issue a permit for open air burning fires. Any
person to whom such a permit has been issued must comply with
the Metro Vancouver Air Quality Bylaw, as amended or replaced;
b)
Approved burning permit signage must be posted in an area
visible from the street;
c)
The Fire Chief or designate may suspend an open-air fire permit
if on the date specified, the wind and weather conditions, or other
conditions such as fire danger rating, are not conducive to fire
safety;
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 23 of 47
d)
CSA/ULC approved briquette, natural gas, electric or propane
appliances are permitted on private property provide such
appliance is operated in accordance with its listed use and
manufacturer's instructions. In the absence of defined operating
instructions, the operator must:
(i)
Maintain a minimum of 3-metre clearance from the nearest
structure, property line, overhead tree or other combustible
material;
(ii)
Keep the appliance under constant supervision when in
use;
(iii)
Provide an adequate extinguishing agent, such as a fire
extinguisher or garden hose; and
(iv)
Dispose of used briquettes in a non-combustible container;
e)
Open air burning for the purposes of Fire Department approved
training is permitted; and
f)
The Fire Chief may only issue a permit for CSA/ULC approved
propane cooking appliances to be used on city property.
6.7
Forest Fire Danger
6.7.1 For the purpose of preventing forest fires within the municipality, the Fire
Chief may:
a)
Order the temporary closure to public use of outdoor trails,
camping areas and other facilities located in or near forested
areas, whether on municipal land or private land;
b)
Order the notification of the public regarding a closure under this
section, including without limitation, the erection of signs and the
publication and broadcasting of notices;
c)
Order that a person not light, ignite, start, or maintain, or allow or
cause to be lighted, ignited, started or maintained, a campfire or
other kind of fire outdoors or within a grill, barbeque or other
outdoor fireplace or appliance with uses wood, charcoal,
briquettes;
d)
Order that any procedures, activity or work program of any
business, contractor, facility or their operations adjacent to a
forest or park be stopped or modified as directed by the Fire
Chief;
e)
Modify and rescind any order under this section;
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 24 of 47
f)
Exempt in writing any person or group of persons from an order
issued under this section where the Fire Chief considers that
such an exemption is unlikely to result in a fire, increase the
danger of a fire or increase the danger to persons or property
from fire; and
g)
Suspend, revoke or deny any permits.
6.7.2 An order under section 6.7.1 does not prevent any person from traveling
to and from occupying their residence or using a highway.
6.7.3 A person must not:
a)
Tamper with or remove any sign or notice placed pursuant
section 6.7.1; or
b)
Violate any order issued pursuant to section 6.7.1.
6.8
Delegation of Authority - Fire Risk in Forest/Woodlands
6.8.1 Where the Fire Chief determines that there is a fire or a risk of fire in a
forest or woodland, the Fire Chief has the authority to take the following
measures to prevent or suppress the fire:
a)
Order the owner(s) or owner's authorized agent, occupier or any
other person who has contributed or may contribute to the risk of
fire to cease any activity that may contribute to the risk of fire;
b)
Order the owner(s) or owner's authorized agent, occupier or any
other person who has contributed or may contribute to a risk of
fire to take specified reasonable actions to prevent or suppress a
fire, including, but not limited to, cutting, removing and
demolishing any trees, vegetation, and buildings;
c)
Order that no person enter or be in all or a portion of the forest or
woodland unless authorized by the Fire Chief; and
d)
Enter on private or public forest or woodland and take any
reasonable action to prevent or suppress a fire, including, but not
limited to, cutting, removing and demolishing any trees,
vegetation, and buildings.
6.9
Compliance with Orders
6.9.1 If the Fire Chief makes an order under sub-section 6.8, any person to
whom the order is directed must:
a)
Cease the activity specified in the order; and/or
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 25 of 47
b)
Take the actions specified in the order.
6.9.2 If the Fire Chief makes an order under sub-section 6.8.1(c), a person
must not enter or be in the forest or woodland specified in the order
unless authorized by the Fire Chief.
6.10
Right to Enter
6.10.1 The Fire Chief may:
a)
On reasonable notice, enter on property for the purpose of fire
protection;
b)
In the case of an emergency, as determined by the Fire Chief or
any person authorized to act in the place of the Fire Chief, enter
on property for the purpose of fire protection; and
c)
On reasonable notice, enter on property that is subject to a
direction in or requirement of a bylaw to ascertain whether the
direction or requirement is being met or the regulations under the
bylaw are being observed.
6.11
Firework Regulations
6.11.1 No person may possess for purposes of re-sale or distribution, offer for
sale, store, distribute or sell:
a)
Low hazard fireworks;
b)
High hazard fireworks; and/or
c)
Firecrackers.
6.11.2 No person shall possess for purposes of use, set off, explode or
discharge:
a)
Low hazard fireworks;
b)
High hazard fireworks; and/or
c)
Firecrackers.
6.11.3 Fireworks may be discharged by persons:
a)
18 years of age or over;
b)
Conducting a public fireworks display or representing an
organization conducting such a public display; and
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 26 of 47
c)
With a permit, being written permission of the Fire Chief having
jurisdiction in the municipality.
6.11.4 Provided that the said display is conducted under the direct supervision
of a person who has been certified as a Fireworks Supervisor under the
Explosives Act.
6.11.5 Any discharge of the fireworks shall comply with any conditions included
in the permit; in strict accordance with the manufacturer's approved
instructions and the requirements of the Explosives Regulatory Division
of Natural Resources Canada.
6.11.6 Before a fireworks permit is issued, the registered owner of the property
must be the applicant for the permit or must have provided written
consent to the applicant to seek such a permit.
6.11.7 Discharge of fireworks is only permitted at the civic address the permit
was issued.
6.11.8 The Fire Chief, a member of the Fire Department or a member of the
Bylaw Department may rescind a permit or written permission and/or
confiscate and seize any fireworks in the event:
a)
Circumstances arising or ascertained after the written permission
or permit was issued demonstrated that a public safety risk or risk
to public or private property exists in connection with the
fireworks event;
b)
The Fire Chief determines that the permit holder submitted false
or inaccurate information in their application;
c)
The permit holder violates or breaches any of the provisions of
the bylaw or any condition of the permit;
d)
The fireworks are used in a dangerous manner. No person may
point, direct or throw fireworks at any person, animal, building or
motor vehicle; and/or
e)
The fireworks are used in a public place. No person may explode,
light or discharge any fireworks on a highway, street, park,
playground, school grounds or any other public place within the
municipality.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 27 of 47
6.12
Fuel Dispensing Stations / Underground Tanks
6.12.1 No person shall operate a fuel dispensing station or install any storage
tank or pump, or measuring device, used or intended to be used, for the
purpose of dispensing Flammable liquids or Combustible liquids unless
that person has a Fuel Dispensing/Underground Tank Permit from the
City.
6.12.2 The owner or occupier of a property may apply for a Fuel
Dispensing/Underground Tank installation or removal Permit upon
paying the permit fee specified in Schedule G in the Fees & Charges
Bylaw.
7.
PART 7 - INSPECTION OF PREMISES AND FIRE PROTECTION EQUIPMENT
7.1
Adoption of Fire Code
7.1.1 The substantive regulations (but not the procedural or remedial
provisions) of the Fire Code are hereby adopted and made part of this
Bylaw such that every provision of the Fire Code shall be considered a
provision of this Bylaw.
7.1.2 Unless otherwise specified, the owner(s) or owner's authorized agent
shall be responsible for carrying out the provisions of the Fire Code.
7.1.3 All Fire Code deficiencies must be corrected immediately without delay.
The Fire Chief may issue a fine for each Fire Code deficiency as per
Schedule A of the Bylaw Notice Enforcement Bylaw.
7.2
Fire Department Access
7.2.1 An owner(s) or owner's authorized agent must, in relation to all property
they own or control:
a)
Maintain and keep all streets, yards and roadways provided for
Fire Department access routes on private property clear and
ready for use by Fire Department vehicles at all times;
b)
Maintain Fire Department access routes in compliance with all
applicable codes and standards;
c)
Post signs in all fire lanes prohibiting parking with the wording
"FIRE LANE - NO PARKING";
d)
Provide directional signage for entrances not visible from the
primary Fire Department response point;
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 28 of 47
e)
Post permanent signage on all exterior doors for mechanical and
electrical rooms; and
f)
Maintain and keep corridors used by the public and exits free of
obstructions.
7.3
Addressing of Occupancies
7.3.1 Each owner of property, whether or not there is a building on the
property, must ensure that the property is individually addressed with
the address assigned by the city.
7.3.2 An individual address must be placed on new or existing buildings or
structures in such a position as to be plainly visible and legible from
the street, road, fire lane, or other right of way or easement and at the
front of the structure.
7.3.3 If the property is vacant, the address must be as close as possible to
the access entrance.
7.3.4 The address must be conspicuous and legible from a distance of 15
metres and in accordance with the city's addressing procedures.
7.3.5 The letters or numbers of any addresses shall be a minimum of 5
inches in height and no less than ½" in a width stroke.
7.3.6 The letters or numbers shall be of a colour in contrast with any
background colour of the building.
7.4
Fire Department Lock Cylinders
7.4.1 All premises, not including single family dwellings, with a monitored or
unmonitored fire alarm or an automatic fire sprinkler system, must install
a Fire Department flush mount Abloy lock cylinder conforming to the Fire
Department key requirements and:
a)
Maintenance and upgrades of the Fire Department lock cylinder
is the responsibility of the owner(s) or owner's authorized agent;
b)
The owner(s) or owner's authorized agent is responsible for
ensuring that the building access, service rooms, and common
area keys that are provided in the Fire Department lock cylinder,
are kept current; and
c)
Additional Fire Department lock cylinders may be required to
accommodate additional sets of access keys for high-rise or
complex buildings.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 29 of 47
7.4.2 For all new construction, the interior access stairs for providing access to
all levels of each building must be located within close proximity to the
Fire Department response point, in a location acceptable to the Fire
Chief.
7.5
Fire Doors
7.5.1 The owner(s) or owner's authorized agent of any building must not block,
wedge or keep open closures in fire separations or allow such action.
7.5.2 Every door used as a closure within a fire separation must have a
permanent sign posted on the visible side of the door when the door is in
the open position with the words "FIRE DOOR KEEP CLOSED".
7.6
Exit Signs
7.6.1 Replacement of illuminated exit signage must be consistent to avoid
combining current code green signs with previous code versions of red
signs.
7.7
Exit Systems
7.7.1 There must be no storage in access to exits, including elevators, stair
shafts, hallways, and fire escapes.
7.8
Location of Fire Alarm Annunciator Panel
7.8.1 Annunciator panel shall be installed on the exterior of the building in
close proximity to the building entrance or located in a common vestibule
accessible by the Fire Department or as determined by the Fire Chief.
7.9
Fire Alarm System Monitoring and Certificate Posting
7.9.1 The owner(s) or owner's authorized agent of any building required by the
Building Code to have a monitored fire alarm system installed, must
obtain a ULC Certificate or equivalent as approved by the Fire Chief and
post it in a permanent manner in close proximity to the monitoring
equipment or such other location acceptable to the Fire Chief.
7.9.2 The owner(s) or owner's authorized agent of any building containing a
ULC monitored fire alarm system must immediately notify the Fire Chief
if the monitoring service has been cancelled or changed or the ULC
Certificate has been removed.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 30 of 47
7.10
Automatic Sprinkler Systems Hydraulic Data Plate
7.10.1 Hydraulic data plate must be installed on the riser indicating maximum
storage height.
7.11
Fire Department Connections
7.11.1 Unless otherwise approved by the Fire Chief, Fire Department
connections must be located not less than 0.61m (24 inches) and not
more than 0.91 m (36 inches) above the level of the adjacent grade or
access level.
7.11.2 Fire Department connections must:
a)
Be clearly identified, clean, functional and with protective caps in
place;
b)
Have signage in place to clearly identify the area that the Fire
Department connection serves and the maximum pumping
pressure, if applicable;
c)
Be kept free and clear by at least one metre (three feet) from all
shrubbery, trees, other vegetation, structures, buildings and
obstructions and be clearly visible at all times form the Fire
Department access route;
d)
The Fire Department connection must be a 0.1 m (4 inch) Storz
connection;
e)
The Fire Department connection must be installed at a thirty (30)
degree downward angle;
f)
Buildings with more than one (1) Fire Department connection
must design system to be interconnected; and
g)
Be located at the property line to the front (address side) of the
property facing the street.
7.12
Fire Pumps & Private Fire Hydrants for Fire Protection
7.12.1 Fire hydrants must be maintained in operable condition at all times.
7.12.2 No person, except a member, may use or take water from any water
supply system nor make any attachment thereto without first obtaining
authorization from the Fire Chief.
7.12.3 Fire hydrants must be in clear view from the driving lane when
approached from either direction.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 31 of 47
7.12.4 Fire pumps must be inspected, serviced and tested at full rated capacity
by a certified fire protection technician at least once per year to ensure
that they are capable of delivering the rated flow.
7.12.5 The owner of any property being used for manufacturing or industrial
uses must ensure that the property is equipped with sufficient fire
hydrants and water supply with pressure and quantity that is adequate to
meet the demands for fire protection purposes to the satisfaction of the
Fire Chief.
7.12.6 The owner(s) or owner's authorized agent of a property on which a
private fire hydrant has been installed must:
a)
Have the private fire hydrant flushed and drained and have all the
threads of outlets and caps greased with waterproof grease not
less than once per calendar year;
b)
Maintain the private fire hydrant so that the center of the 0.1 m (4
inch) port is not less than 0.46 m (18 inches) and not more than
0.91 m (36 inches) above the level of the adjacent grade;
c)
Keep the ground surface clear of shrubs, trees, structures, debris
and any obstructions of any kind within a radius of one metre
(three feet) around the private fire hydrant; and
d)
The private fire hydrant must be painted with the colour coding,
Fire Hydrant Yellow; paint code 020A0176-70402, or a colour as
determined by the Fire Chief.
7.13
Special Fire Suppression Systems
7.13.1 Where a special fire suppression system has been installed, inspection,
testing and maintenance must be provided in conformance with the Fire
Code and/or applicable NFPA standard.
7.14
Commercial Cooking Equipment
7.14.1 Commercial cooking equipment, fire suppression, hood, vent and
exhaust systems must be installed in accordance with the Fire Code.
7.14.2 Commercial cooking equipment and fire suppression systems must be
inspected, tested and maintained in conformance with the Fire Code by
a certified fire protection technician at intervals not greater than 6
months, or more often if required, to remove grease and other
combustible residues.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 32 of 47
7.14.3 A permanent access ladder to the location in which the ventilation fan is
located must be installed to allow for regular fire inspections and
maintenance. If a key is required to gain access, a copy must be
provided to the Fire Department.
7.15
In Building Emergency Responder Communication Enhancement Systems
7.15.1 Radio amplification systems must be installed, maintained and inspected
in buildings as per the "Emergency Services Radio Bylaw, 2021, No.
4210".
7.16
Enclosed Storage Garages for Vehicles
7.16.1 Enclosed storage garages in any multifamily residential development
must be used for the parking of vehicles only (including bicycles,
scooters, motorcycles and watercraft).
7.16.2 "NO STORAGE PERMITTED" signage must be installed in all enclosed
storage garages in any multifamily residential development.
7.16.3 The fire safety plan for an enclosed storage garage must require the
owner or Strata Corporation to inspect the enclosed storage garages
monthly and enforce for compliance with sections 7.16.1 through 7.16.6,
inclusive.
7.16.4 Enclosed storage garages must be available for inspection by the Fire
Department at any time without notice and must not have the access or
visibility of the garage blocked at any time.
7.16.5 Replacement of the door at the entrance to an enclosed storage garage
with a solid door is not permitted.
7.16.6 An owner(s) or owner's authorized agent of a building must in relation to
all property they own or control:
a)
Not permit combustible materials to accumulate or be stored in a
storage garage or underground storage garage designed for the
parking of motor vehicles;
b)
Not permit limited non-combustible materials such as bicycles
and metal ladders to be stored in a storage garage unless, they
can remain in place during a fire without affecting sprinkler flow,
aisles and means of egress, and so as not to interfere with
firefighting activities which is to be determined at the discretion of
the Fire Chief;
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 33 of 47
c)
Ensure that no storage units, cabinets or shelving, whether
combustible or non-combustible, are located within a storage
garage;
d)
Not permit storage in the common area of a storage garage;
storage is only to be permitted in storage rooms designed for
storage use; and
e)
Not permit storage in portable storage containers or bike lockers
in the common area of a storage garage.
7.17
Shipping Containers
7.17.1 A shipping container used for storage of any Dangerous Goods,
flammable or combustible liquids, or other combustible materials must
comply with the following BC Safety Codes and requirements:
a)
Parts 3 and 4 of Division B of the BC Fire Code;
b)
Smoking shall not be allowed in a shipping container;
c)
Where flammable liquids and combustible liquids are stored in a
shipping container, combustible construction shall be removed,
provisions for spill containment installed, and the shipping
container shall be grounded;
d)
The dispensing of flammable liquids and the storage of open
containers in a shipping container is prohibited; and
e)
Compressed gases shall not be stored in a shipping container.
Limited amounts of aerosols may be stored in a shipping
container only when stored in metal cabinets.
7.17.2 Electrical equipment, wiring and installations in a shipping container
must not be installed unless:
a)
They are designed, installed, inspected and maintained by
qualified persons for the applicable environmental and hazardous-
location classification; and
b)
Electrical installations must be approved by the authority having
jurisdiction and records of inspection and maintenance must be
provided to the City on request.
7.17.3 Shipping containers must be positioned such that:
a)
There is a minimum separation of 1.5m between any building or
structure and a shipping container to allow for firefighting access
to the exposed structures;
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 34 of 47
b)
A shipping container must be located at least 6m from exits,
windows or unprotected openings of a building;
c)
Shipping container doors are positioned such that they face away
from any other buildings or structures;
d)
Shipping container doors must be positioned such that they face
away from any means of road access to the shipping container
for fire personnel; and
e)
No combustible materials may be placed near the shipping
container.
7.17.4 A shipping container must be identified such that:
a)
UN Placards for all stored Dangerous Goods must be visible
on the two sides of the shipping container most visible to
emergency responders;
b)
The name of the company/person responsible for the
shipping container and an emergency telephone contact
number must be marked on the shipping container in
lettering visible from a distance of 10m; and
c)
The shipping container and contents must be identified in the
Fire Safety Plan for the property.
7.17.5 A shipping container being used for any kind of storage must have the
following safety features in place prior to any use for storage:
a)
One ventilation opening must be added within 150 mm of the
floor in the shipping container door primarily used for
opening;
b)
One ventilation opening must be added within 150 mm from
the top of the shipping container on the opposite end from
the doors for cross ventilation;
c)
The upper ventilation opening required in (7.17.5.b) must not
directly vent toward a structure and must be equipped with a
wind vent device designed to generate a venturi effect during
low wind speeds; and
d)
Where heavier than air flammable or combustible liquids are
stored in the shipping container, a ventilation opening at a
low level as referenced in (7.17.5.a) must also be installed at
the opposite end from the doors.
7.17.6 The ventilation openings in a shipping container required in section
(7.17.5) must be constructed in accordance with the following minimum
requirements:
a)
Shipping containers 6m or less in length must have two 0.3
m x 0.3 m ventilation openings;
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 35 of 47
b)
Shipping containers over 6m in length must have two 0.5 m
x 0.5 m ventilation openings;
c)
Both ventilation openings must be covered by open grate
wire mesh with greater than 50% free area; and
d)
Both ventilation openings must remain unobstructed by
stored materials at all times and must be kept clean of
internal and external debris.
7.17.7 Where 1A flammable liquids (as defined in the Fire Code) in quantities
greater than 4 litres are stored in a shipping container, provisions shall
be made to comply with the requirements for withstanding an internal
explosion as per the BC Fire Code, BC Building Code and NFPA 68.
7.18
Alternate engineered solutions for ventilation and explosion protection in a
shipping container may be submitted to the Building Department for
consideration
7.19
Construction and Demolition Sites
7.19.1 All construction and demolition sites must have a construction fire safety
plan in accordance with Section 5.11.
7.19.2 Prior to construction of any new water supply system or extension of an
existing water supply system, the owner(s) or owner's authorized agent
of the property must submit plans for the water supply system, including
the proposed fire hydrant locations and all components of the water
supply system to the municipal engineer and the Fire Chief for review
and acceptance.
7.19.3 Fire hydrants must not be decommissioned prior to review and
acceptance by the municipal engineer and the Fire Chief.
7.19.4 All construction and demolition sites must immediately advise the
municipal engineer and the Fire Department of all fire hydrant conditions
affecting fire safety during the installation of the water supply to the site
for mitigation measures, including, but not limited to, fire hydrants
temporarily out of service, low water volumes and low water pressure.
7.19.5 Construction and Demolition sites must maintain a Fire Department
access route as required in the Building Code and Fire Code.
7.19.6 The owner(s) or owner's authorized agent of all construction and
demolition sites must:
a)
Comply with the site-specific construction fire safety plan;
b)
Comply with the site-specific Fire Code protection of adjacent
buildings report; and
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 36 of 47
c)
Ensure that the water supply to the site for mitigating measures
proposed in the construction fire safety plan and the BC Fire
Code protection of adjacent buildings report is installed at the
beginning of construction and is functionally operational before a
hazard exists.
7.20
New Fire Hydrants
7.20.1 As part of the development of a property, the Fire Chief may require an
owner to provide additional fire hydrant(s) to be located and installed to
address Fire Department operational requirements.
7.20.2 New fire hydrants must be installed so that the distribution density and
fire flow requirements will meet the needs for each building, structure or
use that the new fire hydrant serves.
7.20.3 Fire hydrants must be installed in accordance with the city's standard.
7.20.4 Fire hydrants that are connected directly to a building, also known as
wall hydrants, are not permitted in the City of Port Coquitlam.
7.21
Flammable and Combustible Liquids
7.21.1 At no time shall an owner or occupier store more than 25 litres of a
flammable or combustible liquid in a portable container(s) on residential
property.
7.21.2 Flammable and combustible liquids must be handled and stored in
accordance with the Fire Code for assembly, commercial and industrial
occupancies.
7.22
Spray Coating Using Flammable or Combustible Materials
7.22.1 Every owner or occupant of a premises where spray coating operations
using flammable or combustible materials are conducted must ensure
that a building permit for the installation of a spray booth/room is
obtained by the building department.
7.23
Mobile Food Vendors
7.23.1 Every mobile food vendor operation must:
a)
Apply for and obtain an annual inspection by the Fire Chief;
b)
Comply with the commercial cooking equipment requirements in
this Bylaw; and
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 37 of 47
c)
Situate all cooking appliances on a stable non-combustible base
with clearance from combustibles.
7.24
Special Events
7.24.1 Any person organizing or hosting any special event must submit an
application for an occupant load certificate together with a dimensioned
site plan prepared by a registered professional must ensure that:
a)
All cooking and mobile food vendor operations comply with the
commercial cooking equipment requirements in sections 7.14;
b)
Aisles with a minimum width of 3.0 metres are maintained
between displays at all times;
c)
The line of travel to an exit door by an aisle is not more than 45
metres;
d)
Lobbies, foyers or access to exit are not blocked;
e)
A special inspection is scheduled; and
f)
All prescribed fees for special events in accordance with
Schedule C of the Fees and Charges Bylaw, No. 4390, have
been paid.
7.24.2 Any person holding a special event that display automobiles,
motorcycles, scooters, or other fuel-operated vehicles in any public
building must ensure that the vehicles comply with the Fire Code,
including, but not limited to:
a)
The battery must be disconnected and the battery cable placed
or tied in a position to prevent accidental battery contact;
b)
Fuel tanks must be equipped with a key-locking cap or other
similar locking device; and
c)
The quantity of fuel in the fuel tank must not exceed the lesser of
one quarter of the tank capacity or nineteen (19) litres (5 gallons).
7.24.3 Any person holding a special event that requires emergency access
routes to be temporarily closed, an approved traffic control plan and
arrange for volunteers/private security company at all the barricaded
locations to operate the gates to allow access to emergency vehicles.
7.25
Integrated Fire Protection and Life Safety System Testing
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 38 of 47
7.25.1 As per CAN/ULC-S1001, an integrated testing plan must be submitted to
the Fire Department for review as required by the Building Code.
7.25.2 The integrated testing coordinator must ensure that system testing is
coordinated with the Fire Department in advance of the occupancy of a
building being authorized by the Fire Chief.
7.25.3 The integrated testing coordinator must coordinate with the Fire
Department to conduct an integrated test one year after completion of
the initial integrated test.
7.25.4 The integrated testing coordinator must ensure that subsequent
integrated tests are conducted at intervals not exceeding five years.
7.25.5 Integrated testing reports must be kept on site and available for
examination by the Fire Chief on request.
7.25.6 As outlined in CAN/ULC-S1001, the municipality may request that any
building which has not undergone an initial integrated test provide an
integrated testing plan, conduct an integrated test and submit an
integrated testing report.
7.25.7 A functional demonstration of the integrated test may be required by the
Fire Department.
8.
PART 8 - COST RECOVERY AND FEES
8.1
Fees for Permits and Services
8.1.1 Every person who requests any permits, inspections and services from
the Fire Department listed in Schedule G of the Fees and Charges
Bylaw, No. 4390, must pay the applicable fee unless otherwise
exempted under this Bylaw.
8.1.2 Payment of a fee or charge under this Bylaw or Schedule G of the Fees
and Charges Bylaw, No. 4390, does not relieve a person from an
obligation to pay any fee or change prescribed under another enactment.
8.2
Special Inspections, Follow-up and Re-inspections
8.2.1 Where a special inspection is required to determine compliance with the
Fire Code and/or municipal bylaws, the applicant may be required to pay
the fee prescribed in Schedule G of the Fees and Charges Bylaw, No.
4390.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 39 of 47
8.2.2 Where a second and subsequent inspections are required to determine
compliance with instructions noted on a Fire Department "Fire Inspection
Violation Report", the applicant must pay the re-inspection fee as
prescribed in Schedule G of the Fees and Charges Bylaw, No. 4390.
8.3
Fire Investigations
8.3.1 Every owner of property which requires a Fire Department investigation
and report pursuant to the Fire Safety Act must pay the minimum fee for
fire investigation services as prescribed in Schedule G of the Fees and
Charges Bylaw, No. 4390.
8.3.2 If, while completing an investigation pursuant to the Fire Safety Act, the
Fire Chief deems it necessary to obtain the services of a private
investigation company, service contractor, industry specialist or
consultant, site security or structure securing services and/or testing fees
from an independent agency, the owner(s) or owner's authorized agent
of the property shall pay all expenses incurred by the municipality in
relation to such services.
8.4
Comfort Letter Requests
8.4.1 Comfort letter request may be fulfilled on payment of the fee prescribed
in Schedule E of the Fees and Charges Bylaw, No. 4390. Additional fees
may be charged for any requested on-site inspection to complete a
comfort letter.
8.5
Damaged or Contaminated Vehicles or Equipment
8.5.1 The Fire Chief may charge an owner or occupier of a premises for the
costs of decontamination, replacement or repair of Fire Department
vehicles or equipment where such vehicles or equipment has been
damaged or contaminated by a hazardous substance or dangerous
goods and requires decontamination, repair or replacement as a result of
an incident at the owner or occupier's property as per Schedule G of the
Fee and Charges Bylaw.
8.6
Extraordinary Charges
8.6.1 Where additional personnel or equipment must be provided for an
incident, including but not limited to, the provision of equipment and
personnel under a mutual aid agreement with another local government,
rescue vessels or hazardous materials equipment, the owner or occupier
of the property where the incident originates shall pay the applicable fee
prescribed in Schedule G of the Fees and Charges Bylaw, No. 4390.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 40 of 47
8.7
Development Review Fees
8.7.1 When the Fire Department is involved in the process of building permit
issuance or is required to perform an inspection or inspections in order to
determine compliance with an issued building permit, the building permit
holder must pay a fee as set out in Schedule G of the Fees and Charges
Bylaw, No. 4390. Such fee must be paid at the time of building permit
issuance and may be waived for city-led civic projects on city-owned
land in whole or in part, at the discretion of the Fire Chief.
8.8
Occupant Load
8.8.1 The owner(s) or owner's authorized agent of a premises must ensure
that the number of persons in a room does not exceed the maximum
occupant load for that room for that use. Occupant loads are calculated
as follows:
a)
For all new construction - calculated in conformance with the
Building Code; and/or
b)
For all existing construction - calculated in conformance with the
Fire Code.
8.8.2 Occupant load signage must be posted as required by the Fire Code:
a)
In a conspicuous location near the principal entrance to the room
or floor area;
b)
In the form prescribed by the Fire Commissioner; and
c)
Be signed by the Fire Chief.
8.8.3 Every person who receives an occupancy load certificate must pay the
municipality the fee set out in Schedule E of the Fees and Charges
Bylaw, No. 4390.
8.9
Event Approval
8.9.1 If the approval of the Fire Chief is required by an Act, bylaw or procedure
for an event to be permitted within the municipality, the Fire Chief will
review the details of the event application any may:
a)
Refuse approval if the Fire Chief determines that the event may
be hazardous or create a nuisance;
b)
Provide approval without condition; or
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 41 of 47
c)
Provide approval subject to the conditions and restrictions that
they deem necessary for safety and the prevention or the spread
of fire.
8.9.2 If as a condition of event approval, the Fire Chief requires any number of
members to inspect or attend an event site for any time before, during or
after the event, for any reason, the person applying to the municipality
for the event shall pay to the municipality the fees set out in Schedule G
of the Fees and Charges Bylaw, No. 4390.
8.10
Filming Special Effects and Pyrotechnics
8.10.1 Fire protection is required for special effects and pyrotechnics. A permit
is required in the form prescribed by the Fire Chief and must include a
site plan, a description of the event including time and date, the risks of
the event, training staff, and the proposed mitigation measures for the
event. The Fire Chief will review for acceptance the level of fire
protection required based on the location and event specific risks.
8.10.2 Permit, inspection, and fire protection fees for the event must be paid to
the municipality as prescribed in Schedule G of the Fees and Charges
Bylaw, No. 4390.
8.11
Notification of Fire and Sprinkler Alarm Testing
8.11.1 Any owner or occupier of a premises where there is a monitored fire
alarm system must notify their fire alarm monitoring company prior to any
service, test, repair, maintenance, adjustment alteration or installation of
the system which might activate a false alarm which would normally
result in an emergency response.
8.11.2 Where an owner or occupier of a premises fails to notify as required in
section 8.11.1, such owner or occupier must pay the applicable fee
prescribed in Schedule G of the Fees and Charges Bylaw, No. 4390.
8.12
False Alarms and Nuisance Alarms
8.12.1 The owner or occupier of a premises must pay the applicable fee
prescribed the Schedule G of the Fees and Charges Bylaw, No. 4390,
on the occurrence of a second false alarm, or Nuisance Alarm, and for
each subsequent false alarm or nuisance alarm, respecting the premises
occurring in a calendar year.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 42 of 47
9.
PART 9 - PERMITS
9.1
Issuance of Permit
9.1.1 If a permit is required under this Bylaw, the Fire Chief will only issue
such permit if:
a)
The proposed operation or occupancy conforms to this Bylaw,
the Fire Code and any other applicable bylaws or codes;
b)
Receptacles, vehicles, buildings and storage places to be used
for the activity have been reviewed and accepted by the Fire
Chief;
c)
The proposed location for the activity is acceptable to the Fire
Chief with respect to topography, proximity to other occupancies
and adequacy of water supply for fire control; and
d)
The permit fee, if required, has been paid.
9.2
Conditions of Permit
9.2.1 A permit issued by the Fire Chief:
a)
Is not transferable and any change in use or occupancy of a
building or premises or change in operations to be conducted,
requires a new permit;
b)
Is revocable where there is a violation of any condition under
which the permit was issued or any violation of this Bylaw;
c)
Must be posted in the premises in a conspicuous place on the
building or structure to the satisfaction of the Fire Chief; and
d)
May be revoked at any time at the discretion of the Fire Chief.
9.3
Permit Form
9.3.1 Where in this Bylaw a permit is required for any activity, the application
for a permit must be in the form prescribed by the Fire Chief for such
permit.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 43 of 47
10.
PART 10 - ENFORCEMENT
10.1
Orders
10.1.1 If any provision of this Bylaw has been contravened or has not been
complied with, or has been complied with improperly or only in part, or
conditions exist in or upon a building or property to which the bylaw
applied and which, in the opinion of the Fire Chief, constitute a fire
hazard or otherwise constitute a hazard to life or property or both:
a)
The Fire Chief may make an order to ensure full and proper
compliance with this Bylaw and in particular, but without limiting
the generality of the foregoing, may make such recommendations
to the owner or occupier of the building or property as the Fire
Chief deems necessary to correct the contravention or to ensure
compliance with this Bylaw or to remove the hazards referred to
in the bylaw; and
b)
A person who is delivered an order, whether by mail, sign,
posting or personal delivery, must comply with it, either promptly
or, if a time period for compliance is specified, within that time
period. Any and all costs and expenses associated with
compliance are the responsibility of the property owner or other
person to whom the order is directed.
10.1.2 Where an order issued by the Fire Chief is not complied with within the
time specified, the Fire Chief may give such notice as the Fire Chief
deems sufficient for entry onto the property or premises and carrying out
of any remedial work required to bring the property into a safe, compliant
condition, including, within limitation:
a)
Removal and safe disposal of any accumulation of combustible
material;
b)
Installation of a fire safety device; or
c)
Work to secure a vacant or fire-damaged building.
10.1.3 In any circumstance where the Fire Chief has arranged for work to be
carried out on, within, or for a property or building to achieve compliance
with an order, the owner of the property is liable to pay the municipality
the total amount of all costs incurred by the Fire Department for the
purpose.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 44 of 47
10.1.4 If fees charged for fire inspections, reviews or charges payable in
respect of other services to land or improvements that are undertaken
under this Bylaw, are not paid to the municipality by December 31st of
the year in which they are due and payable, the amounts owing may be
collected from the owner in the same manner as for property taxes in
arrears.
10.2
Standard of Work
10.2.1 The Fire Chief may, where work being completed in not covered by this
Bylaw or applicable codes, in the interest of safety adopt the lasted
edition of the National Fire Protection Association codes, standards,
recommended practices and manuals by reference or equivalent.
10.3
Rejection of Work
10.3.1 The Fire Chief may, after the examination of any work, issue a written
rejection which shall have the same force and effect as an order issued
under this Bylaw.
10.4
Form of Order
10.4.1 An order made under this Bylaw will be in writing and may be directed to
the owner, occupier or lessee of the building or property in respect to
whom the order is made.
10.5
Serving and Compliance with Order
10.5.1 An order made under this Bylaw will be served by delivering it or causing
it to be delivered to the person to whom it is directed.
10.5.2 An owner(s) or owner's authorized agent of a building or premises must,
after receipt of a violation report, inspection report or order issued by the
Fire Chief, comply within the stated timelines.
10.5.3 Where an order has been made pursuant to this Bylaw, the owner must
pay applicable fees for inspection prescribed in Schedule G of the Fees
and Charges Bylaw, No. 4390, and if upon re-inspection, a member
determines that the order has not been complied with, the owner must
pay the applicable fee for each additional inspection as prescribed in
Schedule G of the Fees and Charges Bylaw, No. 4390.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 45 of 47
10.6
Cost Recovery
10.6.1 The municipality may recover the costs and expenses of providing
services to lands or improvements service and/or incident response as
outlined in the bylaw, jointly and severally from any person, owner(s) or
owner's authorized agent responsible for the building or premises.
10.6.2 Fees may be collected as property taxes as per section 258(1) of the
Community Charter. If the owner does not pay the cost of the service, on
or before December 31st in the year in which the service was done the
cost shall be added to and form part of the taxes payable on the parcel
as taxes in arrears.
10.7
Compensation to Municipality
10.7.1 Every person who, without necessary cause or required permit, sets a
fire to which the Fire Department responds, or in any manner makes or
causes to be made a false alarm, or causes a fire, damage to property or
injury to persons that can be attributed to the use of fireworks contrary to
Section 6.11 of this Bylaw, or to the unauthorized cultivation, processing,
manufacturing or storage of a controlled substance contrary to the
Controlled Drugs and Substances Act (Canada), SC 1996, c. 19, is
deemed to have caused a nuisance in the community and, in addition to
any fine or other penalty, as an extraordinary service fee is liable to
compensate the municipality for the actual costs and expenses incurred
by the Fire Department in responding to the fire, false alarm or
unauthorized activity. The amount of the extraordinary service fee will be
calculated in accordance with the rates prescribed in Schedule G of the
Fees and Charges Bylaw, No. 4390.
10.7.2 Whether or not a permit is in effect, any person who fails to comply with
this Bylaw must, upon direction of the Fire Chief, immediately and
completely extinguish any fire that the person has started, maintained or
otherwise is responsible for, and at their own cost, promptly take any and
all remedial measures that the Fire Chief considers necessary or
advisable in the interest of fire safety and protection of life or property as
communicated to that person.
10.7.3 If a person fails to extinguish a fire as directed by the Fire Chief or fire
officer, the Fire Chief or fire officer may direct or cause it to be
extinguished and, in that circumstance, the permit holder or other
personal responsible is liable to pay the municipality the costs and
expenses of extinguishment incurred by the Fire Department.
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 46 of 47
10.7.4 Every person who is not a resident or taxpayer of the municipality and
who causes, directs, allows or suffers an incident attended by the Fire
Department is liable to pay the municipality for all costs and expenses
incurred by the Fire Department in response to the incident as well as
any fees imposed under Schedule G of the Fees and Charges Bylaw,
No. 4390.
10.8
Designation of the Bylaw
10.8.1 Pursuant to section 4 of the Local Government Bylaw Notice
Enforcement Act, SBC 2003, c. 60, this Bylaw is designed as a bylaw
that may be enforced by bylaw notice and the Fire Chief, fire inspectors,
and bylaw enforcement officers are designated to enforce this Bylaw
pursuant to the "Bylaw Notice Enforcement Bylaw, No. 3814", or as
otherwise provided by this or any other bylaw of the City of Port
Coquitlam.
10.8.2 Pursuant to sections 264(1)(c) and 265(1)(a) of the Community Charter,
this Bylaw is designated as a bylaw that may be enforced by means of a
ticket in the form prescribed and Fire Chief, fire inspectors, and bylaw
enforcement officers are designated to enforce this Bylaw pursuant to
the "Ticket Information Utilization Bylaw, 1992, No. 2743" or as otherwise
provided by this or any other bylaw of the City of Port Coquitlam.
10.9
Obstruction
10.9.1 A person must not interfere with, delay, obstruct or impede any person
lawfully authorized to enforce this Bylaw in the performance of duties
under this Bylaw.
10.10 Default
10.10.1 Whenever a person is in default of doing any matter or thing required to
be done under this Bylaw, the municipality, through its employees or
agents, may do what is required to be done, at the expense of the
person in default and such costs will constitute a debt due and owing in
accordance with section 17 of the Community Charter.
10.11 Offences and Penalties
10.11.1
A person who:
a)
contravenes a provision of this Bylaw;
b)
causes, consents to, allows or permits an act or thing to be done
contrary to this Bylaw;
City of Port Coquitlam | Fire and Emergency Services Bylaw
No. 4395
Page 47 of 47
c)
neglects or refrains from doing anything required by a provision
of this Bylaw; or
d)
fails to comply with any order, direction or notice given under this
Bylaw commits an offence and is subject to the penalties
imposed by this Bylaw and the Offence Act.
10.11.2
Each instance that a contravention of a provision of this Bylaw
occurs and each day that a contravention occurs or continues
shall constitute a separate offence.
10.11.3
A person found guilty of an offence under this Bylaw is subject to
a fine of not less than $5,000.00 and not more than $50,000.00
for every instance that it occurs or continues, plus the costs of
prosecution.
11.
PART 11 - MISCELLANEOUS
11.1
Severability
If a section, subsection, paragraph, subparagraph or phrase of this Bylaw is for
any reason declared invalid by a Court of competent jurisdiction, the decision shall
not affect the validity of the remaining portions of this Bylaw.
11.2
Repeal
"Fire and Emergency Services Bylaw, 2014, No. 3880" and all its amendments are
hereby repealed, and all references in other bylaws of the City to "Fire and
Emergency Services Bylaw, 2014, No. 3880" are hereby amended to refer to this
"Fire and Emergency Services Bylaw, 2025, No. 4395"
READ A FIRST TIME this
25th day of
February, 2025
READ A SECOND TIME this
25th day of
February, 2025
READ A THIRD TIME this
25th day of
February, 2025
ADOPTED this
11th day of
March, 2025
B. WEST
C. DEAKIN
Mayor
Corporate Officer