Municipal Services page and Municipal Rates pamphlet (effective Sept 1, 2024)

Fort Liard, Northwest Territories · summary & facts

This is the exact embedded text of the captured official document. Snapshot 44f3fe88a68c · verified 2026-10-18 · original document · archived snapshot · unofficial consolidation, the official version is held by the municipal clerk.

The installation of an overflow discharge pipe is a crucial safety measure. It must be positioned lower than the top of the water tank and the fill point and should be visible to the operator during the filling procedure. This is a crucial requirement to prevent overfilling and potential! hazards. The ‘light on full’ indicator, a red light, is not just a component, it's a critical part of the tank. It should be connected to a device in the tank and installed near the fill point, visible from the cab of the delivery truck. The indicator light support should allow for adequate clearance of the water truck The fed indicator light illuminates when the tank s full on a separate circuit. It must be weatherproof and suitable for use during ail seasons. The customer must have a wiring diagram for the indicator light, available for review if needed. The customer is responsible for replacing bulbs and maintaining the indicator light system at his own expense Fanks must not have open lids nor be of a type with an open top. In addition. if tanks are located in basements, covers must be fastened and sealed to the tank to prevent flooding The location of the sewage pump-out point is not just a detail, it's a critical aspect of the installation. It must be within a maximurn distance of 4.5 meters or 15 feet from the service vehicle access. This requirement ts not just important, It's essential for the system's efficient and safe operation and underscores the importance of adhering to regulatory guidelines The sewage pump-out connection fitting shail consist of 3 3-inch or 75-mm female camlocks suitable for use with the pump-out truck adapter on the hose. The fitting wilt have a greater diameter than the water fill point, so a cross- connection cannot be made The sewage holding tank shall be twice the volume of the water storage tank to accommodate sewage and greywater discharge The service pump-out point shall be kept a minimum of 18 inches or 457 millimetres and a maximum of 48 inches or 1,219 millimetres from the ground, including snow and ice accumulations The service pump-out point pipe and camlock adapter shall end with a 90-degree elbow and be constructed of an approved material that does not include plastic or PVC. Galvanized steel or iron is the preferred material The pump-out line from the service point to the tank shall have at least a 5-degree slope to the building such that no sewage is allowed to stand in the line or drain to the outside of the building, and the line within the holding tank shal! not exceed a grade of 30 degrees The pipe from the sewage pump-out service point to the sewage holding tank shall have an interior diameter of a minimum of 4 inches or 100 millimetres or reduced to 3 inches or 75 mm when the developed length of the sewer pump out is greater than 25 feet or 7.5 meters All sewage pump-out lines shall be rigidly secured or anchored at the paint of connection, and further to this, all pipes over 3 meters in developed length shall be anchored every 3 meters The user is responsible for all aspects of the operation and maintenance of systems required for the provision of water and sewage systems. The Hamlet assumes no responsibility for service when user systems do not meet standards or are not maintained. DEPARTMENT PUBLIC WORKS Provides Scheduled Trucked Municipal Services to the Community RATES EFFECTIVE SEPTEMBER 1, 2024 For Services Provided in the Service Area FOR SERVICES OUTSIDE THE SERVICE AREA, CONTACT TH HAMLET OFFICE How Do | Know That the Water Storage | Tank Needs Cleaning? The water from the delivery truck or pipe has | been treated and is safe. However. if your water comes out of the tap looking a little cloudy or the water in your glass dees not clear up after 1 minute, the sediment on the bottom of a storage tank could be the cause, It is often a sign that your tank needs cleaning How Often Should Water Storage Tanks Be Cleaned? Water Storage tanks should be cleaned and disinfected at least once a year iN THE CASE OF A DISCREPANCY BETWEEN THIS PAMPHLET AND THE BYLAW BYLAWS 331 + 327 +340, SUBSEQUENT AMENDMENTS WILL APPLY. ECONOMIC RATE WATER DELIVERY/SEWAGE PUMP-OUT $ .0215 per litre For customers recerning partial municipal services, the rates shall be 60% of the rate for water and 40% for sewage SOLID WASTE PICKUP DISPOSAL Residential Domestic $ 35.00 per month Retail $ 55.00 per month Commercial $ 50.00 per month SUBSIDY RATES JOT AVAILABLE FOR SERVICE OUTSIDE THE SERVICE AREA Bulk Sewage Water delivery and Sewage pump-out subsidy rates are- Residential $ .01 118 per litre Up te Senior Residential (age 70+) $ .0215 per litre To a maximum of 10,000 litres per month - additiona quantities will be billed at a total econormc rate The customer must have had an active account for three years. Garbage pickup and disposal subsidy rates are- Senior Residential $35.00 per month VOLUME CALCULATION The quantity of water will be indicated by an approved truck meter Where no approved truck meter is used, the quantity shall be by the Schedule for “Approved yey ge Quantities for Unmetered Truck Service.” co oy eh 3 To receive services, OW user facilities must meet the A Payment Security Deposit must be paid ae following standards. before the provision of municipal service MINIMUM MONTHLY CHARGES The minimum monthly charge for water/sewage services for each customer shall be $20.00 per month A minimum of one month shall be per charge for garbage pickup disposal provided for the month or part thereof BULK RATES Bulk Water $0.017 per iltre $0.025 per litre Bulk Residential Garbage Disposal $25.00 cm - sorted $80.00 cm - unsorted EXTRA SERVICE RATES Additional water or sewage services MAY be provided to non-residential customers with an active account in good standing This service is unavailable to customers outside the “Municipal Service Area 8am—5pm Monday toFriday $50.00 5 pm — 10 pm Monday to Friday $100.00 8 am — t0 pm Saturday $150.00 8 am — 10 pm Statutory Holiday $150.00 8 am ~ 10 pm Sunday $250.00 + the cost of service. Unimpeded access to the water fill point and sewage pump out shall be maintained, including removing mud, ice, snow, water, pets, vehicles, flower beds, stored items, and yard material. Fill points are not to be located behind homes or without vehicle access The water fill point shail not exceed 20 feet or 6 meters from the access and must extend from the wall facing the access. The fill point must be secured tightly to the building The exterior piping and fill point are to be of metal construction suitable for potable water supply and have good corrosion resistance. Fill points must be fitted with a mate 2-inch or 50 mm camiock fitung that connects to the truck fill hose outlet The water fill point shall be sufficrently smail in diameter that the sewage pump-out hose cannot be inserted The water fill point shall be clearly labelled at all times The water holding tank shall be a minimum of §00 gallons or 2270 titres in size for dwellings of three bedrooms or less. Larger-sized dwellings shail add 800 litres or 176 gallons per additional bedroom for tank sizing Owners of Non-residential buildings are required to size water tanks based on Canadian Architectural standards, the expected water consumption. and a water delivery penod of four (4) days The connection point of the water fill point shall be a minimum of 36 inches or 915 millimetres and a maximum of 48 inches or 1,220 mitlimetres from the ground surface in all seasons The water service line shall have a back grade so that the water does not free flow from the tank or sit in the service line, or it shall have a check valve to prevent free flow and heat tape to prevent freezing