Hydronic Heaters (Section 83) 83. (1) A Hydronic Heater is: (a) not permitted on a lot within: (i) areas A, B and C on Schedule 1; and, (ii) the V1, V2, V3 and VM zones; (b) Only permitted on a lot with an area equal to or greater than 8000 square metres, except in the AG zone; (c) Required to be setback a minimum of: (i) 30 metres from a lot line abutting a public street; (ii) 15 metres from any other lot line; and, (iii) 60 metres from a residential use building located on another lot, (d) Required to have a chimney or stack which projects at least 3.66 metres above ground level; (e) Notwithstanding clause (d), where a Hydronic Heater is within 92 metres of a residential use building located on another lot, the Hydronic Heater must have a chimney or stack which projects at least 4.88 metres above ground level. (By-law 2012-344)