| max height rear side | 2.0 m (Single Family/Multi-Residential, general); 2.5 m if abutting Public Highway, multi-residential, or non-residential property | Table 1 Items 6 and 9, s. 6.0(1) |
| max height front | 1.2 m within 2.4 m of lot line abutting Public Highway; 2.0 m elsewhere in Front Yard | Table 1 Items 1 and 2, s. 6.0(1) |
| permit required | no | |
| pool enclosure | Minimum 1.22 m high; self-closing self-latching gate at ≥1.22 m height; gate kept closed and locked at all times | Schedule "A" s. (1)(b); Gates requirements s. (e), (g) |
| sight triangle | Fences obstructing sightlines must be Open-Fence Construction or erected to create a Sight Triangle to the satisfaction of City staff | s. 6.0(3) and s. 6.0(4) |
| prohibited materials | Barbed wire (except industrial zones ≥1.8 m), electric fences (except agricultural livestock), sheet metal, corrugated metal, materials not intended for permanent fencing | s. 5.0(1), s. 5.0(2), s. 5.0(7) |
scout note
Fence height table limits front-yard fences within 2.4 metres of a public-highway lot line to 1.2 metres. Schedule A requires pool enclosures at least 1.22 metres high with self-closing, self-latching gates.