Town of Buxton Zoning Ordinance
13-1
June 13,2026 Edition
ARTICLE 13 - LAND DEVELOPMENT AND SUBDIVISION STANDARDS
13.1 General.
13.1.A Purpose
The Buxton Planning Board has the responsibility of planning for sound land use
developments that will protect the public health and will enhance the environmental quality
of our community and the land and water resources. At the same time the Planning Board
has the responsibility to plan so that individuals, landowners, prospective lot owners,
taxpayers and the Town are protected from ill-advised development that will add to the tax
burden of the people of the Town. The Town strongly favors sound, planned developments
that show reasonable promise of providing benefits to the people of our Town without
unreasonable expense. Under state law, municipal planning boards are the delegated
authority to approve subdivisions.
13.1.B Authority
13.1.B.1 The following standards have been adopted under the authority of Maine
Subdivision Law (Title 30-A MRSA, S4401 et seq.), and the Town's home rule authority.
13.1.B.2. These standards shall be cited as "Land Development and Subdivision
Standards of the Town of Buxton, Maine" and will be referred to herein as "Land
Development and Subdivision Standards".
13.1.C. Administration
13.1.C.1. The Town of Buxton Planning Board, hereinafter called the "Planning Board" or
"Board", shall administer the standards of this article. All submission to the Board shall
be made through the Code Enforcement Office.
13.1.C.2. The provisions of these standards shall pertain to all the land and buildings
proposed for subdivision, as defined under Article 2, within the boundaries of the Town
of Buxton.
13.1.D. Planning Board Administrative Procedure
13.1.D.1 The Code Enforcement Office shall prepare an agenda for each regularly
scheduled meeting and has the right to limit the number of agenda items to be heard per
meeting.
Town of Buxton Zoning Ordinance
13-2
June 13,2026 Edition
13.1.D.2. Applicants shall be placed on the agenda according to the date of receipt in the
Code Enforcement Office of a complete submission, which meets the requirements of the
applicable stage of subdivision review.
13.1.D.3. Applicants who are not on the agenda and wish to be heard, may be heard only
after all agenda items have been completed and only if a majority of the Board so votes.
No substantive review may take place with respect to such matters, which are not on the
agenda.
13.1.D.4. The Planning Board shall follow the procedures listed below for each stage of
the review process.
13.2 Stages of Subdivision Review.
13.2.A Pre-Application Review of Sketch Plan:
13.2.A.1 An applicant shall present a sketch plan to the Planning Board at least seven (7)
days prior to submission of an application. At the meeting, the applicant shall display
plans with a laptop/electronic files for overhead display for public viewing via the
Town's cable channel and shall appear with information sufficient to:
13.2.A.1.a. Locate the site and identify the zoning classification;
13.2.A.1.b. Describe the site: its area, shape, and existing features, both natural and man-
made; and
13.2.A.1.c. Describe the general intent of development.
13.2.A.2. The Planning Board may have questions and comments.
13.2.A.3. The Planning Board may schedule an on-site inspection.
13.2.A.4. Within thirty (30) days of on-site inspection the Planning Board may make
design suggestions which the applicant should investigate as part of the development
plan.
13.2.B Preliminary Plan Review:
13.2.B.1:
Twelve (12) Copies of the preliminary plan together with an application for
subdivision review is submitted to the Planning Board. These documents must be
received in the Planning Office at least seven (7) days prior to the meeting at which they
are scheduled for preliminary review. If an application and a preliminary plan are not
submitted to the Planning Board within six (6) months following the pre-application
Town of Buxton Zoning Ordinance
13-3
June 13,2026 Edition
meeting, another pre-application meeting must be scheduled. Preliminary plan review
includes:
13.2.B.1.a. applicant's presentation of preliminary plan to Planning Board;
13.2.B.1.b. Planning Board questions;
13.2.B.1.c. Review comments from Code Enforcement Officer and other technical
consultants to the Planning Board;
13.2.B.1.d. Determination by Planning Board of completeness of application plans;
13.2.B.1.e. If application is incomplete, the Planning Board provides a list of items,
which need to be addressed and submitted by the applicant prior to complete
application. The applicant must have a completed plan (all required submissions)
before any further board action is taken;
13.2.B.1.f. When the application is determined complete, the Planning Board schedules a
public hearing within thirty (30) days. The Code Office notifies abutters by certified mail
at least seven (7) days before the hearing, and files certified mail receipts; and
13.2.B.1.g. Within thirty (30) days of the public hearing, the Planning Board shall act on
the plan and shall notify the applicant in writing, of its decisions and reasons therefore.
13.2.C. Final Plan Review
Final plan review includes:
13.2.C.1. Applicant's presentation to the Board. The applicant shall display plans with a
laptop/electronic files for overhead display for public viewing via the Town's cable
channel;
13.2.C.2. Planning Board review and comments;
13.2.C.3. Final review comments from Code Enforcement Officer and other technical
consultants to the Planning Board;
13.2.C.4. Planning Board determination of completeness of application; and
13.2.C.5. Within sixty (60) days of complete application or within thirty (30) days of
public hearing, the Planning Board shall act to approve, approve with conditions or deny
the final plan application and shall notify the applicant in writing of its decision and
reasons therefore.
Town of Buxton Zoning Ordinance
13-4
June 13,2026 Edition
13.3. Submission Requirements and Procedures
13.3.A. Sketch Plan Review
13.3.A.1. The applicant shall make a complete sketch plan submission to Code
Enforcement Office in order to be scheduled on an upcoming agenda. When an
application is received, the Code Enforcement Officer shall give the applicant a dated
receipt and shall notify by mail all abutting property owners of the proposed subdivision
and comply with any other applicable provisions of current state laws regarding the
review process (30-A M.R.S.A. §4403). A copy of the application shall also be forwarded
to the Town's Department Heads or their assigned designees, Buxton Hollis Historical
Society and the Saco River Commission.
13.3.A.2. Submissions
13.3.A.2.a. Twelve (12) complete copies of the plan and application are required for the
Board to proceed with its review.
13.3.A.2.b. The sketch plan shall consist of the following:
(i) The approximate location, dimensions and areas of all existing and proposed lots and
buildings;
(ii) The approximate location and widths of existing and proposed
Streets (intersections within 250 feet of proposed subdivision road
should be shown);
(iii) Approximate topography (USGS) shown at same scale and site layout;
(iv) Location of significant site features such as streams, wetlands, ledge, tree lines etc.;
(v) The approximate location, dimensions and area of all parcels of land proposed to be
set aside as open space;
(vi) Perimeter boundaries from deed description or tax map conforming to legal
description; and
(vii) A location map showing the proximity to "certain" areas i.e. historical, deer
wintering, open space etc.
13.3.A.2.c. Vicinity map showing streets and existing land uses surrounding area;
Town of Buxton Zoning Ordinance
13-5
June 13,2026 Edition
13.3.A.2.d. List of the names and mailing addresses of all property owners abutting the
proposed site (listed by tax map, lot number);
13.3.A.2.e. If the plan is for a "cluster" subdivision, the submission of twelve (12) copies
of the subdivision layout that meets conventional zoning standards is required in
addition to the other submission items; and
13.3.A.2.f. Evidence that the sketch plan has been submitted to each of the department
heads or their assigned designees, applicable Town Committees/ Boards/ Commissions,
and utility companies serving the site.
13.3.A.2.g. An electronic copy of all application materials shall be submitted with the
initial and each subsequent submission. Submission should include two (2) electronic
files in a file format acceptable to the Code Enforcement Office - one file containing all
drawing sheets and one file containing all other supporting documents. Files should be
labeled either "drawings" or "documents" with the Property Tax Map and Lot included
in the file name.
13.3.A.3. The applicant shall make a presentation to Planning Board. The sketch plan
meeting is an informal workshop between the Planning Board and the applicant which
is intended to provide guidance to the applicant in order to achieve a more acceptable
subdivision proposal. The Planning Board may make design or other suggestions to be
addressed by the applicant in subsequent submissions.
13.3.A.4. Site Inspection: The Planning Board shall schedule an on-site inspection with
applicant. The applicant shall have the following areas flagged on-site:
13.3.A.4.a. Property corners;
13.3.A.4.b. Edge of wetlands (different color than property corner flags);
13.3.A.4.c. Approximate centerline of proposed street(s); and
13.3.A.4.d. Approximate lot and/or building locations.
Within thirty (30) days of the on-site inspection, the Planning Board shall set the required
contour level to be shown on future plan submissions should they determine it necessary
and require such other information as deemed necessary at sketch plan meeting. If
required, a copy of this determination will be sent to the applicant by the Code Office.
13.3.A.5. If the sketch plan submitted is significantly different from what the zoning
would permit or what exists at the development site, then the Planning Board may
Town of Buxton Zoning Ordinance
13-6
June 13,2026 Edition
require the applicant to submit a revised sketch plan, which more accurately represents
the site conditions and/or zoning standards.
13.3.B. Preliminary Plan Review
13.3.B.1. Procedure and Fees.
The preliminary plan application shall be accompanied by a fee, as provided in Section
5.8. Within thirty (30) days of determination of a complete preliminary plan application,
the Board shall hold a public hearing. Notice of the date, time and place of the Public
Hearing will be given to the applicant and will be published at least twice in a local
newspaper. The date of first publication must be at least seven (7) days before the hearing.
In addition, abutting landowners will be notified by Certified Mail at least seven (7) days
in advance of the Public Hearing. Notice of the hearing also will be posted at the Buxton
Municipal Office. The developer will be responsible for all costs of notification required
for the Public Hearing, as provided in Section 5.8
In its evaluation of the proposed subdivision, the Board must determine if the plan
provides for compliance with all applicable review standards contained in the Buxton
Zoning Ordinance and the relevant state statutes. In addition to the application
documents originally submitted, the Board may request in its review other studies
deemed necessary or desirable to protect the public convenience, health, safety and
welfare of the citizens of the Town including the occupants of the proposed subdivision.
The Board may also request independent review of some or all of the application and its
supporting documentation. The developer shall be responsible for all costs associated
with the review, as provided in Section 5.8.
13.3.B.2. Preparation of the Preliminary Plan.
The preliminary plan must contain all of the following information:
13.3.B.2.a. Names of record owner(s), subdivider(s), engineer(s) or surveyor(s);
13.3.B.2.b. Deed reference to the land to be subdivided;
13.3.B.2.c. Graphic scale of not more than 100 feet to the inch, date and north point;
13.3.B.2.d. Boundaries of the tract and zoning district;
13.3.B.2.e. Ownership and location of abutting properties;
13.3.B.2.f. Name, location and width of all streets. All street names shown for proposed
streets located in a subdivision must be submitted for approval by the Board of Selectmen
Town of Buxton Zoning Ordinance
13-7
June 13,2026 Edition
to assure that none are duplicates of existing street names or so similar as to cause
confusion;
13.3.B.2.g. Type, location, profile and cross-section of all existing surface water drainage;
13.3.B.2.h. Location of all existing or proposed utilities--water, gas, electricity or other;
13.3.B.2.i. The developer must supply a copy of the medium intensity soil survey covering
the site. If on-site inspection or test pit los indicate the likelihood of poorly or very poorly
drained soils on the site, the Planning Board may request that a high intensity soil survey
be completed for the project site;
13.3.B.2.j. Location of all existing sanitary sewers showing size, profile and cross-section;
or description, plan and location of other means of sewage disposal. When disposal is
proposed by use of individual subsurface disposal areas, soil profile logs meeting
requirements of section 13.5.H must be submitted for each lot. The location of all test pits must
be shown on the plan;
13.3.B.2.k. The general slope of the land must be indicated in five-foot intervals;
13.3.B.2.l. Lot lines and dimensions must be shown;
13.3.B.2.m. Proposed uses of all land, buildings, easements, and rights-of-way including
parking, loading and storage must be indicated.
13.3.B.2.n. Proposed public areas, if any;
13.3.B.2.o. Determination whether project plan is subject to Department of Environmental
Protection approval;
13.3.B.2.p. Drawings, prepared by a registered professional engineer indicating the plan,
profile and cross-section of all proposed streets, sidewalks and parking areas;
13.3.B.2.q. A copy of any deed restrictions, easements, rights-of-way or other
encumbrances currently affecting the property;
13.3.B.2.r. Identification of all wetland areas on the property;
13.3.B.2.s. The location of any open space to be preserved and a description of proposed
ownership and management;
13.3.B.2.t. Delineation of the boundaries of any flood prone areas which exist on the
parcel. All proposals shall include base flood elevations, flood boundaries, and in a
Town of Buxton Zoning Ordinance
13-8
June 13,2026 Edition
riverine floodplains, the floodway data. These determinations shall be based on
engineering practices recognized by the Federal Emergency Management Agency;
13.3.B.2.u. A hydrogeologic assessment prepared by a Certified Geologist or Registered
Professional Engineer experienced in hydrogeology when the subdivision:
(i) is located over a significant sand and gravel aquifer or its recharge area; or
(ii) has an average density of more than one dwelling unit per 100,000 square feet.
The Board may require a hydrogeologic assessment in other cases where site considerations
or development design indicate a potential of adverse impacts on ground water quality.
These cases include extensive areas of shallow to bedrock soils; or cluster developments in
which the average density is less than one dwelling unit per 100,000 square feet but the
density of the developed portion is in excess of one dwelling per 80,000 square feet; and the
proposed use of shared or common subsurface waste water disposal systems.
The hydrogeologic assessment shall be conducted in accordance with the provisions of
Section 13.5.O.1.a below.
13.3.B.2.v.
Identification of any areas of significant wildlife habitat as determined by
the Maine Department of Inland Fisheries and Wildlife or the Buxton Comprehensive
Plan.
13.3.B.2.w. Location of all existing and proposed permanent monuments.
13.3.B.2.x.
Lot numbers in accordance with approved Town numbering policy.
13.3.B.2.y.
An erosion and sedimentation control plan that has been prepared by a
qualified professional.
13.3.B.2.z.
A storm water management plan that has been prepared by a registered
professional engineer.
13.3.C. Final Plan Review
13.3.C.1 Procedure
Within thirty (30) days after approval of the preliminary plan or within any other time limit
which is mutually agreed to, the applicant must submit a final plan to the Board for
inspection to verify that the plan has all the information requested by the Board and
required by applicable state laws.
Town of Buxton Zoning Ordinance
13-9
June 13,2026 Edition
Within sixty (60) days of complete application or within thirty (30) days of public hearing,
the Planning Board shall act: (1) to approve the final plan or to approve the final plan
with conditions to (a) Satisfy the criteria contained in the Buxton Zoning Ordinance and
relevant state laws and (b) protect and preserve the public's health, safety and general
welfare; or (2) to deny the final plan application. The Planning Board shall notify the
applicant in writing of its decision and reasons therefore.
13.3.C.2. Submissions
13.3.C.2.a. All information required for the preliminary plan;
13.3.C.2.b. Completed application form and fee;
13.3.C.2.c. One (1) complete set of one (1) or more maps or drawings and one (1) original
mylar of the filing plan, plus two (2) paper copies; of any changed plans; all to be drawn
at a scale of not more than 100 feet to the inch. Plans shall be no larger than 24x36 inches
in size and shall have a Planning Board signature box;
13.3.C.2.d. The name, registration, seal and signature of the land surveyor, architect,
engineer and/or consultant who prepared the plans;
13.3.C.2.e. The final calculations on the total and net residential acreage of the site of each
proposed lot, as well as deductions made for each of the following: wetlands, steep
slopes, easements, and rights-of-way;
13.3.C.2.f. Landscape and buffer plan if applicable showing what vegetation will remain
and what will be planted including botanical name and common names of plants and
trees, dimensions, approximate planting time and maintenance schedule;
13.3.C.2.g. Types of existing and proposed monumentation shall be identified and
located;
13.3.C.2.h. A Performance bond or letter of credit meeting the standards of 13.5;
13.3.C.2.i. Written evidence of all state and federal approvals;
13.3.C.2.j. Any legal documents which are required to be submitted and reviewed as part
of the subdivision review;
13.3.C.2.k. Longitudinal profiles, radii of curves, and angles of intersections for all
proposed streets;
Town of Buxton Zoning Ordinance
13-10
June 13,2026 Edition
13.3.C.2.l. Offers of cession in a form certified as satisfactory by the Town Attorney of all
land included in streets, highways, parks or other open space ultimately to be dedicated
for public use, or not specifically reserved by the developer; and
13.3.C.2.m. A note on the plan shall state "all plans and documents used to approve this
subdivision are made part of and are a condition of plan approval.
13.3.D. Final Approval; Recording; Lapse of Approval:
13.3.D.1. The final approval is dependent upon, and limited to, the proposals and plans
contained in the application and supporting documents submitted and affirmed by the
applicant. Any variation from the plans, proposals and supporting documents, is subject
to review and approval by the Planning Board.
13.3.D.2. After completing a findings-of-fact and determining all standards in 30-A
M.R.S.A §4404 and these regulations have been met, and upon voting to approve the
subdivision, the Board shall sign the final plan. The Board shall specify in writing its
findings-of-fact and reasons for any conditions or denial. One copy of the signed plan
shall be retained by the Code Enforcement Officer.
13.3.D.3. The applicant shall record the approved plan at the York County Registry of
Deeds and a copy of the plan as recorded and stamped by the Registry shall be brought
back and filed with the Code Enforcement Office. Any subdivision not recorded in the
Registry of Deeds within ninety (90) days of the date upon which the plan is approved
and signed by the Planning Board shall become null and void.
13.3.D.4. No changes, erasures, modifications, or revisions shall be made in any final plan
after Planning Board approval unless the revised final plan is first submitted and the
Board approves the modifications. The Board shall make finding that the revised plan
meets the standards of 30-A M.R.S.A. §4404, and these regulations. In the event that that
a plan is recorded without complying with this requirement, it shall be considered null
and void, and the Board shall record a notice to that effect at the Registry of Deeds. [SEE
SECTION 13.4]
13.3.D.5. Failure to substantially complete construction of the required improvements of
the subdivision within five (5) years of the date of approval and signing of plan shall
render the plan null and void; unless an alternative phasing schedule was made part of
the final plan approval, in which case the time limit shall be five (5) years from the starting
date of the last scheduled development phase. The determination of whether or not
substantial completion has taken place shall be made by the Planning Board based on
evidence presented by the applicant and the town's Code Enforcement Officer
concerning the status of such improvements. Upon determining that a subdivision's
approval has expired under this paragraph, the Board shall have a notice recorded in the
Town of Buxton Zoning Ordinance
13-11
June 13,2026 Edition
Registry of Deeds to that effect. This section only to those projects which receive final
approval after the effective date of this amendment, June 18, 2011.
13.4 Enforcement.
Any person, firm, corporation or other legal entity who violates the provisions of this Article
pertaining to Land Development and Subdivision Standards shall be punished in
accordance with Title 30-A M.R.S.A. S4452. After notification from the Code Enforcement
Officer in writing of the nature of the violation, the violator has thirty (30) days from that
time as a corrective period to ease the violation. Each day the violation exists after the thirty
(30) day period shall constitute a separate offense and the violator shall be punished by a
fine of $100 each day the violation exists. All fines collected shall be payable to the Town of
Buxton.
The Code Enforcement Officer or the appropriate municipal officers may institute
proceedings to enjoin the violations of this Ordinance.
Any person, who after receiving approval from the Planning Board and recording the plan
at the registry of deeds, constructs or develops the subdivision or transfers any lot in a
manner other than depicted on the approved plans or amendments or in violation of any
condition imposed by the Planning Board shall be penalized in accordance with Section
4452.
13.5 General Standards for All Subdivisions.
The standards in this section are intended to clarify and expand upon the criteria for
approval found within the Subdivision Statute (30-A MRSA, S4404). In reviewing a
proposed subdivision, the Board must review the application for conformance with the
following standards and make findings that each has been met prior to the approval of a
Final Plan. In all instances the burden of proof is upon the applicant to present adequate
information to indicate all standards and statutory criteria for approval have been or will
be met.
13.5.A. Based on the Federal Emergency Management Agency's Flood Boundary and
Floodway Maps and Flood Insurance Rate Maps, and information presented by the
applicant whether the subdivision is in a flood-prone area. If the subdivision, or any part
of it, is in such an area, the subdivider shall determine the 100-year flood elevation and
flood hazard boundaries within the subdivision. The proposed subdivision plan must
include a condition of plan approval requiring that the principal structures in the
subdivision will not be constructed within the 100-year floodplain.
13.5.B. Each lot that is offered for sale must be such that any buyer, with or without, a
knowledge of the physical characteristics, will be able to build thereon a reasonable abode
Town of Buxton Zoning Ordinance
13-12
June 13,2026 Edition
with adequate access, water supply, sewage disposal system and reserve sites for disposal
areas in compliance with the Maine Subsurface Wastewater Disposal Rules.
13.5.C Soil Erosion.
13.5.C.1. The proposed subdivision must prevent soil erosion from entering water bodies,
wetlands and adjacent properties.
13.5.C.2. The procedures outlined in the erosion and sedimentation control plan must be
implemented during the site preparation, construction and clean-up stages.
13.5. C.3. Topsoil is considered part of the subdivision and is not to be removed from
the site except for surplus topsoil from roads, parking areas and building excavations.
13.5.D. Traffic Conditions.
13.5.D.1. In general, provision must be made for vehicular access to the subdivision and
circulation within the subdivision in such a manner as to:
13.5.D.1.a. Safeguard against hazards to traffic and pedestrians in existing streets and within
the subdivision;
13.5.D.1.b. Avoid traffic congestion on any street; and
13.5.D.1.c. Provide safe and convenient circulation on public streets and within the
subdivision.
13.5.D.2. More specifically, access and circulation must also conform to the following
standards:
13.5.D.2.a. The vehicular access to the subdivision must
be arranged to avoid traffic
use of existing streets, which the Comprehensive Plan has classified as residential access
streets.
13.5.D.2.b. Where necessary to safeguard against hazards to traffic and pedestrians
and/or to avoid traffic congestion, provision must be made for turning lanes, traffic
directional islands, frontage roads, sidewalks, bicycle ways and traffic controls within
existing public streets.
13.5.D.2.c. Access ways to non-residential subdivisions or to multifamily developments
must be designed to avoid queuing of entering vehicles on any street.
Town of Buxton Zoning Ordinance
13-13
June 13,2026 Edition
13.5.D.2.d. Where topographic and other site conditions allow, provision must be made for
street connections to adjoining lots of similar existing or potential use within areas of the
Town designated as growth areas in the Comprehensive Plan; or in non-residential
subdivisions when such access will
(.i.) Facilitate fire protection services as approved by the Fire Chief; or
(.ii.) Enable the public to travel between two existing or potential uses, generally open
to the public without need to travel upon a public street.
13.5.E Impact on the Town's ability to dispose of solid waste. If the additional solid waste
from the proposed subdivision exceeds the capacity of the Town's solid waste facility,
causes the facility to no longer be in compliance with its license from the Department of
Environmental Protection or causes the Town to exceed its contract with a non-municipal
facility, the applicant must make alternative arrangements for the disposal of solid waste.
The alternative arrangements must be at a disposal facility, which is in compliance with its
license. The Board may not require the alternative arrangement to exceed a period of five
(5) years.
13.5.F. All streets in the plan including private roads must be built by the developer under
the supervision of the Public Works Director in conformance with the Road Acceptance
Regulations. Section 12.4 of the Road Acceptance Regulations must be adhered to at the
time the development is fifty percent (50%) completed. When the Code Enforcement Officer
determines that the fifty percent (50%) completion stage has been reached, he shall inform
the developer by certified mail that the developer has one (1) year from that date to complete
the roads as required under Section 12.4 of the Road Acceptance Regulations and that no
additional building permits shall be issued for the development until the roads are
completed. The provisions of Article 12 are mandatory for all streets in subdivisions
regardless of whether or not they are to remain private. All streets within a new or
expanded subdivision shall be either public or private, but not a mix thereof. Where the
subdivision streets are to remain private roads, there shall be a maintenance agreement for
all lots serviced by the road approved by the Planning Board. This agreement shall specify
the rights and responsibilities of each lot owner with respect to the maintenance, repair and
plowing of the road, and the following words must appear on the recorded plan: amended
June 14, 2003
"All roads in this subdivision shall remain private roads to be maintained by the developer
or the lot owners and shall not be accepted or maintained by the Town. Reference to the
status of the roads as private roads shall be included in the deed of each lot. A description
of the road, including its status as a private road, must be filed with the Town Clerk as an
addendum to the Buxton Road Book"
Town of Buxton Zoning Ordinance
13-14
June 13,2026 Edition
13.5.G. All lot dimensions shall conform to the requirements of Section 9.6.
13.5.H. Each lot that is to be offered for sale or sold must contain a minimum of one
thousand (1,000) square feet of land so located that it is suitable for septic sewage disposal
field absorption area with reasonable assurance of functioning adequately, and to comply
with state laws. Where the site evaluation indicates a depth of original mineral soil of less
than twenty four (24) inches to the limiting factor, a reserve area of an additional one
thousand (1,000) square feet for the eventual expansion or replacement of the disposal area
shall be indicated on the plan. This reserve area shall not be built upon.
13.5.I. The establishment of reserve strips prohibiting access to streets from adjoining lands
will not be permitted.
13.5.J. A permanent marker, meaning a granite monument, a concrete monument, or an
iron pin must be established at every corner of each lot. *In addition, an iron pin must be
set on both sidelines of each lot at a distance of 150 ft - 200 ft from the front of the lot and be
shown on the plan. (*6/97)
13.5.K. Sufficient Water.
13.5.K.1.
Water Supply.
13.5.K.1.a.
Individual wells must be sited and constructed to prevent infiltration of
surface water and contamination from subsurface wastewater disposal systems and other
sources of potential contamination.
13.5.K.1.b. If a central water supply system is provided by the subdivider, the location
and protection of the source, the design, construction and operation of the system must
conform to the standards of the Maine Rules Relating to Drinking Water (10-144A
C.M.R. 231).
13.5.K.1.c. When the development of a new or the expansion of an existing subdivision,
including any existing lots, contains a total of 5 or more lots, the developer shall be required
to install a fire protection water supply within the new or expanded subdivision. The
volume and location of the supply(s) shall be determined by the Fire Chief based on the
NFPA Codes (rural water supply for fire protection) for the type and use of the buildings.
The fire protection water supply shall meet the following standards, along with further
standards, located in the Fire Chief's office: amended June 14, 2003
(.i.) A 10,000 gallon storage tank, or two 5000 gallon tanks interconnected shall be
installed in accordance with the guidelines adopted jointly by the Fire Chief and
Code Enforcement Officer, which guidelines shall be kept on file at the Municipal
Building. Amended June 15, 2002
Town of Buxton Zoning Ordinance
13-15
June 13,2026 Edition
(ii) Entire section deleted by Town meeting vote June 14, 2025.
(.iii.) All fire protection water supplies shall be equipped with a dry hydrant
system that is designed, located and installed in accordance with the guidelines
adopted jointly by the Fire Chief and the Code Enforcement Officer, which
guidelines shall be kept on file at the Municipal Building. The dry hydrant shall be
located so that fire trucks may connect to the hydrant by means of a 10-foot section
of hard suction hose. The area within 37.5' each side of the hydrant, parallel to the
road, and extending to the roadway shall be kept clear of all obstacles and shall be
posted "NO PARKING FIRE LANE". If a private access road is provided, it shall be
a minimum of 12 feet wide; be capable of handling fire trucks in all seasons; be
posted "NO PARKING FIRE LANE", and be otherwise in compliance with the above
referenced guidelines. If the hydrant is located on a public road, the hydrant shall
be located a minimum of 20 feet from the paved portion of the road and, where
needed, fill material shall be provided to widen the road shoulder so that fire
trucksmay connect to the hydrant without interfering with passing traffic.
(iv.) Prior to release by the Town of the signed subdivision plan for recording,
an easement in recordable form shall be conveyed to the Inhabitants of the Town
of Buxton, which permits the Town to use and maintain the fire protection
water supply and dry hydrant. The form of the easement shall be subject to
approval of the Town Attorney.
(v.) A detailed plan of the water supply, hydrant, piping overflow and roadway
shall be submitted to the Planning Board as part of the preliminary plan submission.
The Fire Chief and the Code Enforcement Officer shall review the plan and make
their recommendations in writing to the Planning Board.
(vi.) The fire protection water supply and dry hydrant shall be installed by the
developer in accordance with the above referenced guidelines. No building permit
for any dwelling in the subdivision may be issued unless and until the fire protection
water supply and hydrant have been tested and approved as being in working order
by the Fire Chief or his designee and the Code Enforcement Officer.
(.vii.) The requirement of compliance with this Section 13.4.K.I.c. shall not apply
if the developer, as a written condition of subdivision approval, agrees to install
an approved sprinkler system in each and every dwelling in the development.
The sprinkler system shall meet the current standards of Section 10.17.B of this
ordinance. Amended 6/18/05 and 6/14/25.
13.5.K.2. Water Quality.
Town of Buxton Zoning Ordinance
13-16
June 13,2026 Edition
Water supplies must meet the primary drinking water standards contained in the Maine
Rules Relating to Drinking Water. If existing water quality contains contaminants in excess
of the secondary drinking water standards in the Maine Rules Relating to Drinking Water,
that fact must be disclosed in a note on the plan to be recorded in the registry of deeds
13.5.L. Impact on natural beauty, aesthetics, historic sites, wildlife habitat, rare natural
areas or public access to the shoreline.
13.5.L.1. Preservation of natural beauty and aesthetics.
13.5.L.1.a. The Board may require that the application include a landscape plan that will
show the preservation of any existing trees larger than 24" inches diameter breast height,
the replacement of trees and vegetation and graded contours.
13.5.L.1.b. When a proposed subdivision street traverses open fields the plans must include
the planting of street trees.
13.5.L.2. Retention of Open Spaces and Natural or Historic Features.
13.5.L.2.a. If any portion of the subdivision is located within an area designated by the
Comprehensive Plan as open space or greenbelt, that portion must be reserved for open
space preservation.
13.5.L.2.b. If any portion of the subdivision is located within an area designated as a critical
natural area by the Comprehensive Plan or the Department of Economic and Community
Development's Natural Heritage Program, the plan must indicate appropriate measures for
the preservation of the values which qualify the site for such designation.
13.5.L.2.c. If any portion of the subdivision is designated a site of historic or prehistoric
importance by the Comprehensive Plan or the Maine Historic Preservation Commission,
appropriate measures for the protection of the historic or prehistoric resources must be
included in the plan.
13.5.L.2.d. Section 11.6.C. must be adhered to when the subdivision is a clustered
development.
13.5.L.3. Preservation of Significant Wildlife Habitat.
If any portion of a proposed subdivision lies within:
(a.) 250 feet of the following areas identified and mapped by the Department Of Inland
Fisheries and Wildlife as:
Town of Buxton Zoning Ordinance
13-17
June 13,2026 Edition
(i.) habitat for species appearing on the official state or federal lists of endangered
or threatened species; or
(ii.) high and moderate value waterfowl and wading bird habitats including nesting
and feeding areas;
(b.) 1,320 feet of an area identified and mapped by the Department of Inland Fisheries and
Wildlife as a high or moderate value deer wintering area or travel corridor;
(c.) or other important habitat areas identified in the Comprehensive Plan, the applicant
must demonstrate that there shall be no adverse impacts on the habitat and species it
supports. A report prepared by wildlife biologist, selected or approved by the Board, must
be submitted. This report must assess the potential impact of the subdivision on the
significant habitat and adjacent areas that are important to the maintenance of the affected
species and must describe appropriate mitigation measures to ensure that the subdivision
will have no adverse impacts on the habitat and species it supports.
13.5.L.4. Any existing public rights of access to the shoreline of a water body must be
maintained by means of easements or rights-of-way or should be included in the open space
with provisions made for continued public access.
13.5.M. Financial and Technical Capacity.
13.5.M.1. Financial Capacity.
The applicant must have adequate financial resources to construct the proposed
improvements and meet the criteria of the statute and the standards of Section 13.4.
When the applicant proposes to construct the buildings as well as the subdivision
improvements, the applicant must have adequate financial resources to construct the
total development. In making the above determinations, the Board must consider the
proposed time frame for construction and the effects of inflation.
13.5.M.2. Technical Ability.
13.5.M.2.a. The applicant must retain qualified contractors and consultants to supervise,
construct and inspect the required improvements in the proposed subdivision.
13.5.M.2.b. In determining the applicant's technical ability, the Board must consider the
applicant's previous experience, the experience and training of the applicant's consultants
and contractors and the existence of violations of previous approvals granted to the
applicant.
Town of Buxton Zoning Ordinance
13-18
June 13,2026 Edition
13.5.N. Impact on water quality or shoreline. Cutting or removal of vegetation along water
bodies must not increase water temperature, result in shoreline erosion or sedimentation of
water bodies.
13.5.O. Impact on ground water quality or quantity.
13.5.O.1. Ground Water Quality.
13.5.O.1.a. When a hydrogeologic assessment is submitted, the assessment must contain
at least the following information:
(.i.) A map showing the basic soil types.
(ii.) The depth of the water table at representative points throughout the
subdivision.
(iii.) Drainage conditions throughout the subdivision.
(iv.) Data on the existing ground water quality either from test wells in
the subdivision or from existing wells on neighboring properties.
(v.) An analysis and evaluation of the effect of the subdivision on ground water
resources. In the case of residential developments, the evaluation must, at a
minimum, include a projection of post development nitrate-nitrogen concentration
at any wells within the subdivision, at the subdivision boundaries and at a distance
of 1,000 feet from potential contamination sources, whichever is a shorter distance.
(vi.) A map showing the location of any subsurface wastewater disposal systems
and drinking water wells within the subdivision and within 200 feet of the
subdivision boundaries.
13.5.O.1.b. Projections of ground water quality must be based on the assumption of drought
conditions (assuming 60% of annual average precipitation).
13.5.O.1.c. A subdivision must not increase any contaminant concentration in the ground
water to more than one half of the Primary Drinking Water Standards. (The Primary
Drinking Water Standards have been set by the Maine Department of Human Services for
those contaminants which pose a health threat, such as bacteria, nitrate and heavy metals)
A subdivision must not increase any contaminant concentration in the ground water to
more than the Secondary Drinking Water Standards. (The Secondary Drinking Water
Town of Buxton Zoning Ordinance
13-19
June 13,2026 Edition
Standards are for contaminants which pose more of an aesthetic concern than a health
concern, such as iron and manganese)
13.5.O.1.d. If ground water contains contaminants in excess of the primary standards and
the subdivision is to be served by on-site ground water supplies, the applicant must
demonstrate how water quality will be improved or treated.
13.5.O.1.e. If ground water contains contaminants in excess of the secondary standards, the
subdivision must not cause the concentration of the parameters in question to exceed 150%
of the ambient concentration. (It is not uncommon for natural contamination levels to
exceed the secondary standards in Maine, particularly for iron and manganese and
occasionally sulfur)
13.5.O.1.f. Subsurface waste water disposal systems and drinking water wells must be
constructed as shown on the map submitted with the assessment. If construction standards
for drinking water wells or other measures to reduce ground water contamination and
protect drinking water supplies are recommended in the assessment, those standards must
be included as a note on the Final Plan and as restrictions in the deeds to the affected lots.
13.5.O.2.
Ground Water Quantity.
13.5.O.2.a. Ground water withdrawals by a proposed subdivision must not lower the
water table beyond the boundaries of the subdivision.
13.5.O.2.b. A proposed subdivision must not result in a lowering of the water table at the
subdivision boundary by increasing runoff with a corresponding decrease in infiltration of
precipitation.
13.5.P. Identification of freshwater wetlands.
Freshwater wetlands must be identified in accordance with the 1987 Corps of Engineers
Wetland Delineation Manual, published by the United States Army Corps of Engineers.
13.5.Q. Storm water management.
13.5.Q.1. Adequate provision must be made for disposal of all storm
water
generated
within the subdivision and any drained ground water through a management system of
swales, culverts, underdrains and storm drains. The storm water management system must
be designed to conduct storm water flows to existing watercourses or storm drains except
where retention basins are designed or ground water recharge is desirable.
13.5.Q.2. Where a subdivision is traversed by a stream, river or surface water drainage way
or where the Board feels that surface water runoff to be created by the subdivision should
be controlled, there shall be provided easements or drainage rights-of-way with swales,
culverts, catch basins or other means of channeling surface water within the subdivision
Town of Buxton Zoning Ordinance
13-20
June 13,2026 Edition
and over other properties. Wherever the storm drainage system is not within the right-of-
way of a public street, perpetual easements shall be provided to the Town allowing
maintenance and improvement of the system.
13.5.Q.3. All components of the storm water management system must be designed to limit
peak discharge rates to predevelopment levels for the 2-year, 10-year and the 25-year
frequency, 24-hour duration storms, based on rainfall data for Portland, Maine.
13.5.Q.4. Outlets must be stabilized against soil erosion by stone riprap or other suitable
materials which reduce water velocity.
13.6 Performance Guarantees.
13.6.A. Types of Guarantees. With submittal of the application for Final Plan approval,
the subdivider shall provide one of the following performance guarantees for an amount
adequate to cover the total construction costs of all required improvements, taking into
account the time span of the construction schedule and the inflation rate for construction
costs:
13.6.A.1. The establishment of an escrow account by means of either a certified check
payable to the Town or a savings account or certificate of deposit naming the Town as
owner;
13.6.A.2. A performance bond payable to the Town issued by a surety company approved
by the Municipal Officers;
13.6.A.3. An irrevocable letter of credit from a financial institution establishing funding
for the construction of the required improvements from which the Town may draw if
construction is inadequate, approved by the Municipal Officers; or
The amount of the performance guarantee shall be determined by the Board with the advice
of the Public Works Director, Municipal Officers and/or Town Attorney. The performance
guarantee shall be for a term not less than three (3) years and shall not expire between
October 30 and April 15. The developer shall renew the performance guarantee if
development is not complete after three (3) years. If the developer does not renew the
performance guarantee, the developer shall be subject to fines as stated in Article 5.3.
No signed subdivision plans shall be released or recorded, and no building permits of any
kind shall be issued until a performance guarantee has been accepted by the Town.
(amended 6/15/19)
13.6.B.
Contents of Guarantee. The performance guarantee shall contain a
construction schedule, itemized cost estimates for each major phase of construction
Town of Buxton Zoning Ordinance
13-21
June 13,2026 Edition
taking into account inflation, provisions for inspections of each phase of construction,
provisions for the release of part or all of the performance guarantee to the developer
and a date after which the developer would be in default and the Town shall have
access to the funds to finish construction. (amended 6/12/04)
13.6.C. Escrow Account. A cash contribution to the establishment of an escrow
account shall be made by either a certified check made out to the municipality, the
direct deposit into a savings account or the purchase of a certificate of deposit. For any
account opened by the subdivider, the municipality shall be named as owner and the
consent of the municipality shall be required for a withdrawal. Any interest earned on
the escrow account shall be returned to the subdivider unless the municipality has
found it necessary to draw on the account, in which case the interest earned shall be
proportionately divided between the amount returned to the subdivider and the
amount withdrawn to complete the required improvements.
13.6.D. Performance Bond. A performance bond shall detail the conditions of the
bond, the method for release of the bond or portions of the bond to the subdivider and
the procedures for collection by the municipality. The bond documents shall
specifically reference the subdivision for which approval is sought.
13.6.E. Letter of Credit. An irrevocable letter of credit from a bank or other lending
institution shall indicate that funds have been set aside for the construction of the
subdivision and may not be used for any other project or loan.
13.6.F. Release of guarantee. Prior to the release of any part of the performance
guarantee, the Board shall determine to its satisfaction, in part upon the report of the
Code Enforcement Officer or whatever other agencies and departments may be
involved, that the proposed improvements meet or exceed the design and construction
requirements for that portion of the improvements for which the release is requested.
13.6.G. Default. If, upon inspection, the Code Enforcement Officer finds that any of
the required improvements have not been constructed in accordance with the plans and
specifications filed as part of the application, he/she shall so report in writing to the
Code Enforcement Officer, the Municipal Officers, the Board and the subdivider or
builder. The Municipal Officers shall take any steps necessary to preserve the Town's
rights.
13.7 Revisions to Approved Plans.
An applicant for a revision to a previously approved plan shall, at least seven days
prior to a scheduled meeting of the Board, request to be placed on the Board's agenda.
Town of Buxton Zoning Ordinance
13-22
June 13,2026 Edition
If the revision involves the creation of additional lots or dwelling units, the procedures
for preliminary plan approval shall be followed. If the revision involves only
modifications of the approved plan, without the creation of additional lots or dwelling
units, the procedures for final plan approval shall be followed. If the revision involves
only modifications of conditions or notes to the approved plan, the procedures for final
plan approval shall be followed with the exception that a complete plan need not be
recreated. Upon approval, a notarized document of plan revision shall be provided by
the Planning Board. The document of plan revision shall be filed in the York County
Registry of Deeds. This filing shall be the responsibility of the applicant.
The applicant shall submit a copy of the approved plan as well as the required copies of
the proposed revisions. The applicant shall also include enough supporting
information to allow the board to make a determination that the proposed revisions
meet the standards of these regulations and the criteria of the statute. The revised plan
shall indicate that it is the revision of a previously approved and recorded plan and
shall show the title of the subdivision and the book and page or cabinet and sheet on
which the original plan is recorded at the Registry of Deeds.
The Board's scope of review shall be limited to those portions of the plan which are
proposed to be changed.
PAGE INTENTIONALLY LEFT BLANK