This is the exact embedded text of the captured official document.
Snapshot 58ad836c9d1d · verified 2026-09-22 ·
original document ·
archived snapshot ·
unofficial consolidation, the official version is held by the municipal clerk.
Table of Contents
Section 1: General Provisions.....................................................................................................7
A. Repeal And Replacement...............................................................................................................7
B. Title.................................................................................................................................................7
C. Authority..........................................................................................................................................7
D. Applicability.....................................................................................................................................7
E. Exemptions..................................................................................................................................... 7
F. Conflict With Other Ordinances.......................................................................................................9
G. Separability.....................................................................................................................................9
H. Amendments...................................................................................................................................9
I. Effective Date................................................................................................................................... 9
Section 2: Purposes..................................................................................................................11
A. Protect General Welfare................................................................................................................11
B. Protect Environment......................................................................................................................11
C. Promote Community Development...............................................................................................11
D. Balance Property Rights...............................................................................................................11
E. Reduce Fiscal Impact....................................................................................................................11
F. Implement The Comprehensive Plan............................................................................................11
G. Establish Procedures And Standards...........................................................................................11
Section 3: Definitions................................................................................................................13
A. Construction Of Language............................................................................................................13
B. Definitions..................................................................................................................................... 13
Section 4: Administration...........................................................................................................37
A. Administering Body.......................................................................................................................37
B. Approval Required........................................................................................................................37
C. Application Required.....................................................................................................................37
D. Other Permits Required................................................................................................................37
E. Start And Completion Of Construction..........................................................................................38
F. Conditions Of Approval..................................................................................................................39
G. Public Hearings............................................................................................................................40
H. Permit Transfers...........................................................................................................................41
Section 5: Criteria Of Approval..................................................................................................43
A. Pollution........................................................................................................................................ 43
B. Erosion..........................................................................................................................................43
C. Traffic............................................................................................................................................ 43
D. Sewage Disposal..........................................................................................................................43
E. Municipal Solid Waste Disposal....................................................................................................44
F. Aesthetic, Cultural And Natural Values..........................................................................................44
G. Financial And Technical Capacity.................................................................................................44
H. Sufficient Water............................................................................................................................ 44
I. Public Water Supply....................................................................................................................... 44
J. Surface Waters..............................................................................................................................44
I
K. Ground Water............................................................................................................................... 44
L. Flood Areas................................................................................................................................... 44
M. Freshwater Wetlands...................................................................................................................45
N. River, Stream Or Brook................................................................................................................45
O. Storm Water................................................................................................................................. 45
P. Spaghetti-Lots Prohibited..............................................................................................................45
Q. Municipal Services.......................................................................................................................45
R. Lake Phosphorus Concentration..................................................................................................45
S. Impact On Adjoining Municipality..................................................................................................45
T. Lands Subject To Liquidation Harvesting......................................................................................46
U. Conformity With Local Ordinances And Plans..............................................................................46
Section 6: Inspection, Violation And Enforcement....................................................................47
A. Inspection..................................................................................................................................... 47
B. Recording Of Subdivision Plan Without Approval Prohibited........................................................48
C. Conveyance Without Approval Prohibited....................................................................................48
D. Conveyance Without Recording Prohibited..................................................................................49
E. Conveyance Of Lots Or Dwelling Units Not Shown On Final Plan Prohibited..............................49
F. Utility Hookups Prior To Approval Prohibited.................................................................................49
G. Road Completion Prior To Conveyance Required........................................................................49
H. Life Safety And Fire Suppression Prior To Conveyance Required...............................................49
I. Failure To Comply With Conditions Of Approval............................................................................49
J. Owner Responsible For Off-Site Sedimentation...........................................................................49
K. Nuisances..................................................................................................................................... 50
L. Code Enforcement Officer.............................................................................................................50
M. Legal Actions................................................................................................................................50
N. Fines............................................................................................................................................. 51
O. Contractor Liability........................................................................................................................51
Section 7: Appeals....................................................................................................................53
A. Powers And Duties Of The Board Of Appeals..............................................................................53
B. Variance Appeals..........................................................................................................................53
C. Administrative Appeals.................................................................................................................54
D. Appeal Procedure.........................................................................................................................54
E. Appeal To Superior Court..............................................................................................................56
Section 8: Administrative Procedures.......................................................................................57
A. Purpose........................................................................................................................................ 57
B. Agenda..........................................................................................................................................57
Section 9: Pre-Application Conference (Optional)....................................................................59
A. Procedure.....................................................................................................................................59
B. Submission...................................................................................................................................59
C. Contour Interval And On-Site Inspection......................................................................................59
D. Rights Not Vested.........................................................................................................................59
Section 10: Application Procedure And Submission Requirements.........................................61
A. General......................................................................................................................................... 61
B. Procedure.....................................................................................................................................61
II
C. Submissions.................................................................................................................................63
D. Final Approval And Filing..............................................................................................................79
Section 11: Growth Management Districts And Nonconformance............................................83
A. Growth Management Districts Established...................................................................................83
B. Standards Establishing Districts And District Descriptions...........................................................83
C. Official Growth Management District Map....................................................................................84
D. Interpretation Of District Boundaries............................................................................................84
E. Division Of Lots By District Boundaries........................................................................................85
F. Dimensional Requirements...........................................................................................................86
G. Reserved...................................................................................................................................... 87
H. District Uses................................................................................................................................. 87
I. Nonconforming Structures, Uses And Lots....................................................................................89
Section 12: Performance Guarantees.......................................................................................95
A. Types Of Guarantees....................................................................................................................95
B. Contents Of Guarantee.................................................................................................................95
C. Escrow Account............................................................................................................................95
D. Performance Bond........................................................................................................................96
E. Letter Of Credit.............................................................................................................................96
F. Conditional Agreement..................................................................................................................96
G. Phasing Of Development.............................................................................................................96
H. Extension...................................................................................................................................... 96
I. Release Of Guarantee...................................................................................................................97
J. Default........................................................................................................................................... 97
K. Improvements Guaranteed...........................................................................................................97
Section 13: Waivers..................................................................................................................99
A. Waiver Of Submission Requirements...........................................................................................99
B. Waiver Of Performance Standards...............................................................................................99
C. Waivers Of Required Improvements.............................................................................................99
D. Waivers Conditionally Granted.....................................................................................................99
Section 14: Provision For Cluster Development.....................................................................101
A. Purpose...................................................................................................................................... 101
B. Application Procedure.................................................................................................................101
C. General Requirements...............................................................................................................101
Section 15: Provision For Planned Unit Development............................................................105
A. Purpose...................................................................................................................................... 105
B. Procedure...................................................................................................................................105
C. Standards...................................................................................................................................107
Section 16: Reserved..............................................................................................................109
Section 17: Dedication And Maintenance Of Common Land And Services............................111
A. Dedication................................................................................................................................... 111
B. Maintenance................................................................................................................................111
Section 18: General Performance Standards.........................................................................113
A. Conformance With Comprehensive Plan....................................................................................113
B. Municipal Services......................................................................................................................113
III
C. Preservation And Enhancement Of The Landscape...................................................................114
D. Relation Of Proposed Buildings To Environment........................................................................114
E. Land Not Suitable For Building...................................................................................................115
F. Topsoil And Vegetation Removal.................................................................................................116
G. Erosion And Sedimentation Control............................................................................................116
H. Stormwater Management...........................................................................................................117
I. Reserved......................................................................................................................................118
J. Site Conditions.............................................................................................................................118
K. Plumbing.....................................................................................................................................118
L. Water Supply...............................................................................................................................118
M. Utilities........................................................................................................................................ 119
N. Sign Standards...........................................................................................................................119
O. Lighting Design Standards.........................................................................................................119
P. Dust, Fumes, Vapors, Gases, Odors, Glare, And Explosive Materials........................................119
Q. Reserved.................................................................................................................................... 120
R. Refuse Disposal......................................................................................................................... 120
S. Protection Of Significant Fisheries And Wildlife Habitat.............................................................120
T. Scenic Locations.........................................................................................................................120
U. Archaeological Sites...................................................................................................................121
V. Historic Locations........................................................................................................................121
W. Agricultural Protection Buffer Strips...........................................................................................121
X. Vehicular And Pedestrian Traffic.................................................................................................121
Y. Ground Water Protection.............................................................................................................122
Z. Noise........................................................................................................................................... 124
Aa. Buffers And Screening Standards.............................................................................................132
Section 19: Road Design And Construction Standards..........................................................135
A. General Requirements................................................................................................................135
B. Road Design Standards..............................................................................................................136
C. Road Construction Standards....................................................................................................140
D. Cleanup......................................................................................................................................142
E. Road Names And Signs..............................................................................................................142
F. Certification Of Construction Of Roads.......................................................................................142
G. Acceptance Of A Road By The Town To Become A Town Road.................................................142
H. Private Roads.............................................................................................................................144
Section 20: Parking And Entrance Design Standards............................................................145
A. General Requirements................................................................................................................145
B. Vehicular Entrance Design Standards........................................................................................146
C. Parking Area Design Standards.................................................................................................148
D. Off-Site Parking Facilities........................................................................................................... 150
Section 21: First Responder Access And Fire Lanes.............................................................153
A. Applicability................................................................................................................................. 153
B. Access Proximity To Structures:.................................................................................................153
C. Fire Apparatus Access Road Specifications:..............................................................................153
D. Fire Lanes, Marking, And Obstruction:.......................................................................................154
IV
E. Security Gates And Locked Access:...........................................................................................154
F. Address Identification:.................................................................................................................155
Section 22: Storm Drainage Design And Construction Standards.........................................157
A. General Provisions.....................................................................................................................157
B. Storm Water Management Design Standards............................................................................157
C. Storm Drainage Construction Standards....................................................................................158
Section 23: Borrow Pits...........................................................................................................161
A. Applicability................................................................................................................................. 161
B. General Restrictions...................................................................................................................161
C. General Standards.....................................................................................................................161
Section 24: Home Occupations..............................................................................................163
Section 25: Life Safety And Fire Suppression........................................................................165
A. Fire Protection Options...............................................................................................................165
B. Documentation Of Approved Fire Protection Option...................................................................165
C. Sprinkler Systems.......................................................................................................................165
D. Location Of Water Storage Facilities:.........................................................................................165
E. Water Storage Facilities..............................................................................................................165
F. Hydrants...................................................................................................................................... 166
G. Fire Ponds.................................................................................................................................. 169
Section 26: Commercial Wind Energy Facilities.....................................................................171
A. Design Safety Certification.........................................................................................................171
B. Structure Type.............................................................................................................................171
C. Blade Clearance.........................................................................................................................171
D. Signal Interference.....................................................................................................................171
E. Overspeed Controls And Brakes................................................................................................171
F. Voltage Warnings........................................................................................................................ 171
G. Visual Appearance.....................................................................................................................172
H. Shadow Flicker And Blade Reflection.........................................................................................172
I. Use Of Public Roads....................................................................................................................172
J. Safety Setbacks.......................................................................................................................... 173
K. Local Emergency Services.........................................................................................................173
L. Insurance.................................................................................................................................... 173
M. Public Inquiries And Complaints.................................................................................................173
N. Decommissioning.......................................................................................................................174
Section 27: Mineral Exploration Or Extraction........................................................................177
A. General Restrictions...................................................................................................................177
B. General Standards......................................................................................................................177
C. Additional Submittals For Site Plan Review................................................................................179
D. Reclamation Bond Update..........................................................................................................180
Section 28: Wireless Telecommunications Facilities..............................................................181
A. Purpose...................................................................................................................................... 181
B. Applicability................................................................................................................................. 182
C. Review And Approval Authority...................................................................................................182
D. Application Procedures...............................................................................................................183
V
E. Standard Of Review....................................................................................................................183
F. Standard Conditions Of Approval................................................................................................186
G. Abandonment.............................................................................................................................187
Section 29: Solar Energy Systems.........................................................................................189
A. Purpose...................................................................................................................................... 189
B. Applicability................................................................................................................................. 189
C. Review And Approval Authority...................................................................................................190
D. Dimensional Requirements........................................................................................................190
E. Standard For Approval................................................................................................................191
F. Decommissioning And Removal..................................................................................................195
G. Modifications.............................................................................................................................. 196
Section 30: Recreational Lodging Facilities............................................................................199
A. Applicability................................................................................................................................. 199
B. Operating Standards...................................................................................................................199
C. Land Use Standards...................................................................................................................200
Appendix 1: Exhibits And Maps..............................................................................................203
VI
SECTION 1:
GENERAL PROVISIONS
SECTION USER'S GUIDE: This section contains general information related to the
title of the Ordinance, the statutory authority under which it was prepared and
adopted, the municipal officials charged with its administration, the area of juris
diction, the date of its adoption, and the procedure for its amendment.
A.
REPEAL AND REPLACEMENT
The Town of Newry's Unified Development Review Ordinance, last adopted on June 15,
1992, including all amendments thereto, is hereby repealed and replaced in its entirety by
the provisions set forth in this new Ordinance.
B.
TITLE
This Ordinance shall be known and be cited as the Unified Development Review Ordi
nance for the Town of Newry, Maine.
C.
AUTHORITY
This Ordinance is adopted pursuant to the Home Rule Powers as provided for in Article
VIII-A of the Maine Constitution and Title 30-A, M.R.S.A. §3001.
D.
APPLICABILITY
The provisions of this Ordinance shall apply to the following land uses and buildings
within the boundaries of the Town of Newry (Additional requirements and restrictions may
be imposed by the Town of Newry Shoreland Zoning Ordinance):
1.
Subdivisions as defined by Title 30-A, M.R.S.A. §4401.
2.
Site Uses: Building(s), structure(s) and use(s) of land for commercial, indus
trial, office, multiple dwelling residential that is not a subdivision as defined, mu
nicipal, institutional, utility, fraternal, and recreational purposes, including:
a.
New buildings and structures;
b.
New uses of existing buildings, structures and land;
c.
Resumption of uses which have been discontinued for at least two years;
d.
Existing uses which seek to expand by either 1000 square feet or 25% in
area, whichever is lesser, within any 10 year period, in floor space, park
ing area, or outdoor storage area.
E.
EXEMPTIONS
This Ordinance does not apply to the following:
May 12, 2026
Section: 1 | 7
1.
Existing uses or uses which were legally established prior to the adoption of
this Ordinance;
2.
Subdivision lots exempted by Title 30-A, M.R.S.A. §4401;
3.
Detached single family and two family dwelling units, when not part of a new
subdivision or new development proposal. Except that detached single family
and two family dwelling units and lots shall comply with:
a.
§11 Growth Management Districts and Nonconformance,
b.
§20.B. Parking Area Design Standards,
c.
and §29 Solar Energy Systems.
4.
Agricultural land management practices, forest management activities, timber
harvesting activities and timber harvesting; and
5.
Home occupations which meet the following conditions do not need Site Plan
approval:
a.
The home occupation is incidental and secondary to the primary residen
tial use of the premises;
b.
Do not employ any persons who do not make the residence their perma
nent home;
c.
Do not display any exterior sign larger than eight (8) square feet, exterior
exhibits, exterior storage of materials or any other exterior indications of
the home occupation or variation from the residential character of the prin
cipal dwelling or accessory structure;
d.
Do not generate any nuisance, waste discharge, noise, vibration, smoke,
dust, odors, heat, glare, radiation, fumes, or electrical interference de
tectable to the normal senses or which interferes with normal radio or tele
vision reception, data transmission or causes other nuisances which ex
tend beyond the limits of the subject property; and
e.
Are not likely to generate regular daily or seasonal traffic not associated
with residential uses.
Home Occupations which do not meet the criteria in §1.D.5.a-e above shall
comply with §18.AB.
8 | Unified Development Review Ordinance
F.
CONFLICT WITH OTHER ORDINANCES
Whenever the requirements of this Ordinance are in conflict with the requirements of any
other lawfully adopted rule, regulation, ordinance, the more restrictive standards shall
govern.
G.
SEPARABILITY
In the event that any section, subsection or any provision of this Ordinance shall be de
clared by any court of the competent jurisdiction to be invalid for any reason, such deci
sion shall not be deemed to affect the validity of any other section, subsection or other
portion of this Ordinance, to this end, the provisions of this Ordinance are hereby de
clared to be severable.
H.
AMENDMENTS
This Ordinance may be amended by a majority vote of a regular or special town meeting.
Amendments may be initiated by a majority vote of the Select Board, by request of the
Planning Board, or by a petition signed by a number of registered voters greater than
10% of the votes cast in the last gubernatorial election in the Town. The Select Board
shall conduct a public hearing on the amendments.
I.
EFFECTIVE DATE
The provisions of this Ordinance shall become effective on May 12, 2026.
May 12, 2026
Section: 1 | 9
SECTION 2:
PURPOSES
SECTION USER'S GUIDE: This section presents the broad goals of this Ordi
nance. These goals are not intended to be specific standards used by the Plan
ning Board in its consideration of applications but rather as a guide for provisions
contained herein.
The purposes of this Ordinance are as follows:
A.
PROTECT GENERAL WELFARE
To assure the comfort, convenience, safety, health and welfare of the citizens of Newry;
B.
PROTECT ENVIRONMENT
To protect the natural resources from unacceptable adverse impacts and to integrate new
development harmoniously into the Town's natural environment;
C.
PROMOTE COMMUNITY DEVELOPMENT
To promote the development of an economically sound and stable community;
D.
BALANCE PROPERTY RIGHTS
To protect property rights and values by balancing the rights of landowners to use their
land for the purposes regulated by this Ordinance with the corresponding rights of abut
ting and neighboring landowners to enjoy their property without undue disturbance from
noise, smoke, dust, fumes, odor, glare, traffic, stormwater run-off or the pollution of
ground or surface water resources;
E.
REDUCE FISCAL IMPACT
To provide the means for assessing development proposals for their fiscal impacts on the
municipality's ability to provide and improve necessary public facilities and services;
F.
IMPLEMENT THE COMPREHENSIVE PLAN
To implement the goals and policies of Newry's comprehensive plan
G.
ESTABLISH PROCEDURES AND STANDARDS
To establish procedures whereby the Town Officials may review the developments regu
lated by this Ordinance by providing fair and reasonable standards for evaluating such
developments, to provide a public hearing process through which Town residents may
raise questions and receive answers regarding how such developments may affect them
and to provide procedures whereby aggrieved parties may appeal decisions made under
this Ordinance to the Board of Appeals.
May 12, 2026
Section: 2 | 11
To establish standards that:
1.
Encourage orderly growth and development in appropriate areas of the com
munity, while protecting the Town's rural character, making efficient use of pub
lic services and preventing development sprawl;
2.
Plan for, finance and develop an efficient system for public facilities and ser
vices to accommodate anticipated growth and economic developments;
3.
Promote economic climate which increases job opportunities;
4.
Encourage and promote affordable, decent housing opportunities;
5.
Protect the quality and manage the quantity of the Town's water resources, in
cluding ground water extraction from aquifers and rivers;
6.
Protect the other critical natural resources, including, without limitations, wet
lands, wildlife, and fisheries habitat, shorelands, scenic vistas, and unique nat
ural areas;
7.
Safeguard agricultural and forest resources from development which threatens
those resources;
8.
Preserve historic and archaeological resources;
9.
Promote and protect the availability of outdoor recreation opportunities, includ
ing access to surface waters.
10.
Seek to retain landowner permission for use of traditional trail systems and
back county recreation opportunities from development which would reduce
such opportunities.
12 | Unified Development Review Ordinance
SECTION 3:
DEFINITIONS
SECTION USER'S GUIDE: This section contains specific definitions for words and
phrases used in this Ordinance.
A.
CONSTRUCTION OF LANGUAGE
In this Ordinance, certain terms and words shall be interpreted as follows:
1.
The words "persons" and "applicant" includes individuals, firms, associations,
corporations, organizations, and similar entities;
2.
Words used or defined in one tense or form shall include other tenses or deriv
ative forms;
3.
Words in the singular number shall include the plural number and words in the
plural shall include the singular number;
4.
The masculine gender shall include the feminine and the feminine shall include
the masculine;
5.
The word "shall" is mandatory;
6.
The word "may" is permissive;
7.
The words "used" or "occupied" include words "intended", "designed", or "ar
ranged to be used or occupied";
8.
The word "building" including the word "structure":
9.
The word "dwelling" includes the word "residence";
10.
The word "lot" includes the words "plot" or "parcel";
11.
The word "town" or "municipality" means Town of Newry, Maine;
12.
The word "Board" refers to the "Planning Board" duly appointed by the Town of
Newry, Maine.
13.
The words "Municipal Officers" refers to the Select Board duly elected by the
Town of Newry, Maine; and
14.
In case of difference of meaning or implication between the text of this Ordi
nance, any map, illustration, or table, the text shall control.
B.
DEFINITIONS
For the purpose for interpreting this Ordinance, the following terms, phrases, words and
their derivations shall have the meaning given herein.
May 12, 2026
Section: 3 | 13
ABUTTERS:
Property owner within five hundred (500) feet of the property involved,
including owners of the property on the opposite side of a road or right of way and in adja
cent municipalities. The owners of the property shall be considered to be those against
whom taxes are assessed.
ACCESSORY DWELLING UNIT:
A self-contained dwelling unit located within, at
tached to or detached from a single-family dwelling unit or multi-unit structure located on
the same parcel of land.
ACCESSORY USE OR STRUCTURE: A subordinate use of a building, other structure or
land, or a subordinate building or other structure:
1.
Whose use is customary in connection with the principal building, other struc
ture or use of land; and
2.
Whose use is clearly incidental to the use of the principal building, other struc
ture or use of land; and
3.
Which is located on the same lot with the principal building, other structure or
use of land, or on a lot adjacent to such lot if in the same ownership or part of
the same establishment.
AGRICULTURAL/FORESTRY SALES AND SERVICE:
The use of buildings or land
for the sale of equipment or products or services to those primarily engaged in agriculture
or forestry and/or the sale of agricultural/forestry products to the public.
AGRICULTURAL LAND MANAGEMENT PRACTICES:
Means those devices and
procedures utilized in the cultivation of land in order to further crop and livestock produc
tion and conservation of related soil and water resources.
ALTERATION:
Structural changes, rearrangement, change of location or addition to a
building, or structure other than repairs and modification in building equipment, involving
more than 25% increase in the overall floor space or bulk of the building or structure at
any time or in total since the effective date of this ordinance.
AMBIENT SOUND: At a specified time, the all-encompassing sound associated with a
given environment, being usually a composite of sounds from many sources at many di
rections, near and far, including the specific facility of interest.
ANSI S1.1-1960:
American National Standard Acoustical Terminology.
ANSI S12.9-1988:
American National Standard Quantities and Procedures for Descrip
tion and Measurements of Environmental Sound, Part 1;
ANSI S3.20-1973:
American National Standard Psychoacoustical Terminology.
14 | Unified Development Review Ordinance
ANTENNA
Means any system of poles, panels, rods, reflecting discs or similar de
vices used for the transmission or reception of radio or electromagnetic frequency sig
nals.
APPROVED RESIDENTIAL SUBDIVISION:
A residential subdivision for which all ap
plicable land use permits have been issued, provided that the time for beginning con
struction under such permits has not expired.
AQUIFER (Significant ground water aquifer):
Significant ground water aquifer means a
porous formation of ice-contact and glacial outwash sand and gravel or fractured bedrock
that contains significant recoverable quantities of water which is likely to provide drinking
water supplies.
ASSOCIATED FACILITIES:
Elements of a Commercial Wind Energy Facility other
than its Generating Facilities that are necessary to the proper operation and maintenance
of the Commercial Wind Energy Facility, including but not limited to buildings, access
roads, Generator Lead Lines and substations.
AUTHORITY HAVING JURISDICTION (AHJ):
An organization, office, or individual
responsible for enforcing the requirements of a code or standard, or for approving equip
ment, materials, an installation, or a procedure. AHJs ensure compliance with safety reg
ulations and may include local code enforcement officers, fire departments, and planning
boards.
AUTOMOBILE GRAVEYARD/RECYCLING/JUNKYARD:
As defined in Title 30-A
MRSA §3752.
BED AND BREAKFAST:
A dwelling unit where the general public can stay overnight and
are served a breakfast meal, for which a fee is charged.
BORROW PIT:
Means an excavation for sand, fill or gravel that is moved off the parcel
that it is excavated from.
BUILDABLE LAND: Land other than the following:
1.
Land which is situated below the normal high water mark of any water body.
2.
Land which is located within the one hundred (100) year floodplain, other than
roads and driveways which shall be constructed to meet standards contained in
the Shoreland Zoning Ordinance and/or Floodplain Management Ordinance
where applicable, as identified by the Federal Emergency Management
Agency, Flood Insurance Administration, unless the applicant shows proof
through the submittal of materials prepared by a Professional Land Survey that
the property in question lies at least one (1) foot above the one hundred (100)
year flood level. The elevation of filled or made land shall not be considered.
May 12, 2026
Section: 3 | 15
3.
Land which is part of a permanent road right-of-way or permanent road ease
ment.
4.
Land that has been created by filling or draining a pond or wetland that has not
received approval for such filling and draining by the Army Corps of Engineers
and/or the Maine Department of Environmental Protection.
5.
Land that has been identified as significant wildlife habitat by the Maine Depart
ment of Inland Fisheries and Wildlife when a mitigation plan has not been ap
proved by the Maine Department of Inland Fisheries and Wildlife.
BUILDING:
Any structure having a roof or partial roof supported by columns or walls
used for the shelter or enclosure of persons, animals, goods or property of any kind.
CAMPGROUND:
A Recreational Lodging Facility which includes any area or tract of
land to accommodate a user's recreational vehicle, motor home, tent or other form of
temporary shelter and for which a fee is charged. The shelter must be provided by the
user, arrives with the user at the commencement of their stay and departs with the user at
the termination of their stay.
CEO: See Code Enforcement Officer.
CLUSTER SUBDIVISION: A subdivision in which the dimensional requirements are re
duced below those normally required in return for permanently preserved open space.
CODE ENFORCEMENT OFFICER:
Appointed by the Select Board, the Code En
forcement Officer shall enforce the town's ordinances, keep a complete record of all es
sential transaction of the office and investigate complaints of alleged violations of local
land use laws.
COLOCATION
When referring to a Wireless Telecommunications Facility means the
use of such facility by more than one wireless telecommunications provider.
COMMERCIAL USE:
The use of lands, buildings or structures the intent or result of
which is the production of income from the buying or selling of goods or services. Com
mercial use does not include a home-based business (home occupation), the rental of a
single dwelling unit or a single lot or incidental sales of goods or services as may be al
lowed by permit or standard.
COMMERCIAL COMMUNICATION TOWER:
Any structure, antenna, tower, or other de
vice which provides to the public for a fee radio/television transmission, commercial mo
bile wireless services, unlicensed wireless services, cellular phone services, specialized
mobile radio communications (SMR), common carrier wireless exchange phone services
and personal communications service (PCS) or pager services. This definition does not
16 | Unified Development Review Ordinance
include amateur radio towers/antenna, or towers/antenna used to provide communication
for a single business.
COMMERCIAL RECREATION:
Any commercial enterprise which receives a fee in re
turn for the provision of some recreational activity including but not limited to: amusement
facilities, racket and tennis clubs, health facility, amusement parks, gymnasiums and
swimming pools, shooting ranges, skiing, golf course, and the like.
COMMERCIAL WIND ENERGY FACILITY:
A wind energy facility whose primary pur
pose is to sell electricity to be supplied to the regional electric power grid. A Commercial
Wind Energy Facility includes Generating Facilities and Associated Facilities.
COMMON LAND:
Land owned jointly or in common by the owners of the dwelling units
by means of a homeowners' association, by an association which has as its principal pur
pose the conservation or preservation of land in essentially its undeveloped condition, or
by an acceptable legal entity.
COMPLETE APPLICATION:
An application shall be considered complete upon sub
mission of the required fee and all information required by this Ordinance, or by a vote by
the Board to waive the submission of required information. The Board shall issue a re
ceipt to the applicant upon its determination that an application is complete.
COMPREHENSIVE PLAN:
As defined in Title 30-A MRSA §4301.
CONTIGUOUS LOTS:
Lots which adjoin at any line or point, except that lots on oppo
site sides of a public or private road shall be each considered a separate tract or parcel
unless such road was established by the owner of land on both sides thereof subsequent
to September 22, 1971.
CONSTRUCTION: Activity and operations associated with the facility or expansion of the
facility or its site.
CORNER CLEARANCE:
the minimum required distance between a street intersection
and the nearest edge of a Driveway or Vehicular Entrance. This distance is typically mea
sured along the edge of the roadway's traveled path (or edge of pavement) from the inter
section of the two street right-of-way lines to the nearest edge of the driveway (usually the
point of tangency for the driveway's or vehicular entrance's curb return or flare).
DEMOLITION/WASTE DISPOSAL:
A facility including a landfill operated by a public,
quasi-public or private entity the purpose of which is to dispose of useless, unwanted or
discarded solid material with insufficient liquid content to be free flowing, including by way
of example, and not by limitation to, rubbish, garbage, scrap materials, junk, refuse, inert
fill material, landscape refuse, and demolition debris. The definition does not, however,
include commercial hazardous waste disposal facilities or recycling of products.
May 12, 2026
Section: 3 | 17
DEP CERTIFICATION:
A certification issued by the Department of Environmental Pro
tection pursuant to 35-A M.R.S. §3456 for a Wind Energy Development.
DESIGNATED SCENIC RESOURCE
Means that specific location, view, or corridor, as
identified as a scenic resource in the Town's adopted comprehensive plan, an ordinance
adopted by the Town or by a State or federal agency, that consists of:
1.
a three-dimensional area extending out from a particular Viewpoint on a public
way or within a public recreational area, focusing on a single object, such as a
mountain, resulting in a narrow corridor, or a group of objects, such as a down
town skyline or mountain range or views of seascapes or offshore islands, re
sulting in a panoramic view corridor; or
2.
lateral terrain features such as valley sides or woodland as observed to either
side of the observer, constraining the view into a narrow or particular field, as
seen from the Viewpoint on a public way or within a public recreational area.
DETACHED SINGLE FAMILY DWELLING:
A dwelling unit that is not attached to any
other dwelling unit by any means.
DEVELOPMENT AREA:
Building(s), structure(s) and use(s) of land for commercial, in
dustrial, office, multiple dwelling residential, municipal, institutional, utility, fraternal and
recreational purposes, including new buildings and structures; new uses of existing build
ings, structures, and land; resumption of uses which have been discontinued for at least
two years; and existing uses which seek to expand by either 1000 square feet or 25% in
area, whichever is lesser, within any 10 year period, in floor space, parking area, seating
capacity or outdoor storage area.
DEVELOPED AREA:
Any area on which a site improvement or change is made, in
cluding buildings, landscaping, parking areas, roads, and other areas not revegetated.
DISABILITY:
Any disability, infirmity, malformation, disfigurement, congenital defect or
mental condition caused by bodily injury, accident, disease, birth defect, environmental
conditions or illness; and also includes the physical or mental condition of a person which
constitutes a substantial handicap as determined by a physician or in the case of mental
handicap, by a psychiatrist or psychologist, as well as any other health or sensory impair
ment which requires special education, vocational rehabilitation or related services.
DRIVEWAY: A vehicular access way serving two or less lots and/or dwelling units
DWELLING UNIT:
A room or group of rooms designated and equipped exclusively for
use as living quarters for one family including provisions for living, cooking and eating; in
cludes single family houses and the units in a duplex, apartment houses, multi-family
dwelling and residential condominiums. Access is not through another dwelling unit.
18 | Unified Development Review Ordinance
ELECTRICAL EQUIPMENT
When referring to a Solar Energy System means any
device such as an outdoor electrical unit/control box, that transfers the energy from the
solar energy system to the intended location.
ELECTRICITY GENERATION (PRODUCTION, OUTPUT)
The amount of electric en
ergy produced by transforming other forms of energy, commonly expressed in kilowatt-
hours (kWh) or megawatt-hours (MWh).
EMERGENCY:
An unforeseen combination of circumstances which calls for immediate
action at a facility.
EMERGENCY MAINTENANCE AND REPAIRS:
Work done in response to an emer
gency at a facility.
ENERGY SUM OF A SERIES OF LEVELS:
Ten times the logarithm of the arithmetic
sum of the antilogarithms of one-tenth of the levels.
ENVIRONMENTAL SENSITIVE AREAS:
Those significantly natural; scenic, historic,
and archaeological areas identified in the Town of Newry Comprehensive Plan.
EQUIVALENT SOUND LEVEL:
The level of the mean-square A-weighted sound pres
sure during a stated time period, or equivalently the level of the sound exposure during a
stated time period divided by the duration of the period. (NOTE:
For convenience, a
one hour equivalent sound level should begin approximately on the hour.)
EXISTING FACILITY:
A Commercial Wind Energy Facility legally constructed before
the effective date of this ordinance or a proposed Commercial Wind Energy Facility for
which the Application is found complete on or before the effective date of this ordinance.
Any facility with an approved permit application which has been remanded to planning
board by a court of competent jurisdiction for further proceedings relating to noise limits or
noise levels prior to the effective date of this ordinance shall not be deemed an existing
facility and the ordinance shall apply to the existing noise sources at that facility.
EXISTING HOURLY SOUND LEVEL:
The hourly sound level resulting from routine op
eration of an existing facility prior to the first expansion that is subject to this ordinance.
For purposes of this definition:
1.
a Residence is considered planned when the owner of the parcel of land on
which the Residence is to be located has received all applicable building and
land use permits and the time for beginning construction under such permits
has not expired,
2.
a residential subdivision is considered approved when the developer has re
ceived all applicable land use permits for the subdivision and the time for be
ginning construction under such permits has not expired.
May 12, 2026
Section: 3 | 19
EXPANSION:
When referring to a Wireless Telecommunications Facility means the ad
dition of antennas, towers, or other devices to an existing structure.
FAA:
Means the Federal Aviation Administration, or its lawful successor.
FCC: Means the Federal Communications Commission, or its lawful successor.
FINAL PLAN:
The final drawings, on which the applicant's plan of subdivision or devel
opment is presented to the Board for approval and which, if approved, may be recorded
at the Registry of Deeds.
FIRE DEPARTMENT ACCESS ROAD: A public or private roadway, vehicular entrance,
driveway, or right-of-way that is specifically designated, constructed, and maintained to
provide fire-fighting personnel, apparatus, and equipment with safe, reliable, and timely
entry to any building, structure, or site within the Town.
FIRE LANE:
A public or private roadway, vehicular entrance, driveway, or right-of-way
that is specifically designated, constructed, and maintained to provide fire-fighting person
nel, apparatus, and equipment with safe, reliable, and timely entry to any building, struc
ture, or site within the Town.
FLICKER:
The phenomenon of noticeable pulsating light produced by the wind turbine
blades passing between the sun and the observer and temporarily interrupting the sun's
rays."
FLICKER SECTOR:
A zone with the shape of a circular sector within which the ob
server may see the sun's rays interrupted by the Wind Turbine's blades in the phenome
non herein called Flicker. The radius of this circular sector that shall be equal to the maxi
mum width of the blade of each Wind Turbine times 100. The Flicker occurs mostly to the
north of each Wind Turbine base and is limited by the radial line with an azimuth of 114
degrees going counter-clockwise through north to the radial line with an azimuth of 246
degrees. This zone represents the area north and south of the Wind Turbine within which
the Flicker phenomenon throughout the year. This maximum area occurs on the day of
the summer solstice .
FLOOD HAZARD AREAS:
See one hundred year flood.
FRESH WATER WETLAND:
Means fresh water swamps, marshes, bogs and similar
areas which are:
1.
Inundated or saturated by surface or ground water at a frequency and for a du
ration sufficient to support, and which under normal circumstances do support
a prevalence of wetland vegetation typically adapted for life in saturated soils;
and
2.
Not considered part of great pond, river, stream or brook.
20 | Unified Development Review Ordinance
These areas may contain small stream channels or inclusions of land that do not conform
to the above criteria.
FOREST MANAGEMENT ACTIVITIES: Includes timber cruising and other forest resource
evaluation activities, pesticide application, timber stand improvement, pruning, timber har
vesting and other forest harvesting, regeneration of forest stands, and activities associ
ated with these forest practices.
GENERATING FACILITIES:
Wind Turbines and electrical lines, not including Gener
ator Lead Lines, that are immediately associated with the Wind Turbines.
GENERATOR LEAD LINE:
A generator interconnection transmission facility as de
fined by 35-A M.R.S. § 3132 (1-B).
GROSS FLOOR AREA:
All habitable area with headroom in excess of five (5) feet.
GROUNDWATER: Water found underground in the cracks and spaces in soil, sand and
rock, especially that supplies wells and springs.
HEIGHT:
When referring to a Wireless Telecommunications Facility means the verti
cal distance measured from the base of the antenna support structure at grade to the
highest point of the structure, even if said highest point is an antenna. Measurement of
tower height shall include antenna, base pad, and other appurtenances and shall be mea
sured from the finished grade of the facility site. If the support structure is on a sloped
grade, then the average between the highest and lowest grades shall be used in calculat
ing the antenna height.
HEIGHT OF STRUCTURE:
The vertical distance between the mean finished grade
at the downhill side of the structure measured from the finished top floor level intended for
human habitation.
HISTORIC AREAS: Historic sites administered by the Bureau of Parks and Lands of the
Maine Department of Conservation.
HISTORIC OR ARCHAEOLOGICAL RESOURCES: Means resources that are:
1.
Listed individually in the National Register of Historic Places or eligible for list
ing on the National Register;
2.
Certified or preliminarily determined by the Secretary of the Interior as con
tributing to the historical significance of a registered Historic District or a district
preliminarily determined by the Secretary of the Interior to qualify as a regis
tered Historic District;
3.
Individually listed on a state inventory of historic places in states with historic
preservation programs approved by the Secretary of the Interior;
May 12, 2026
Section: 3 | 21
4.
Individually listed on a local inventory of historic places in communities with his
toric preservation programs that have been certified by Secretary of the Interior
through the Maine Historic Preservation Commission; or
5.
Areas identified by a governmental agency such as the Maine Historic Preser
vation Commission as having significant value as an historic or archaeological
resource and any areas identified in the municipality's comprehensive plan,
which have been listed or are eligible to be listed on the National Register of
Historic Places.]
HISTORIC DISTRICT:
Means a geographically definable area possessing a signifi
cant concentration, linkage or continuity of sites, buildings, structures or objects united by
past events or aesthetically by plan or physical development and identified in the munici
pality's comprehensive plan, which is listed or is eligible to be listed on the National Reg
ister of Historic Places. Such Historic Districts may also comprise individual elements
separated geographically, but linked by association or history.
HISTORIC LANDMARK:
See Historic Site.
HISTORIC SITE:
Any site, structure, district or archaeological site which has been offi
cially included on the National Register of Historic Places and/or on the Maine Historic
Resource Inventory, or which is established by qualified testimony as being of historic sig
nificance.
HOME OCCUPATION:
An occupation or profession which results in a product or ser
vice and is conducted in whole or in part in a residential structure, accessory structure to
a residential use or property which is:
1.
clearly incidental to and compatible with the residential use of the property and
surrounding residential uses; and
2.
which employs no more than two (2) persons other than family members resid
ing in the home.
HOTEL/MOTEL: A commercial building or group of buildings built to accommodate for a
fee travelers or other transit quests who are staying for a limited duration with sleeping
rooms without kitchen facilities and each room or rooms having its own private bathroom
and its own separate entrance leading either to the outdoors or a common corridor or
hallway. A hotel may include restaurant facilities where food is prepared and meals
served to guests and other customers.
HOURLY SOUND LEVEL: The equivalent sound level for one hour measured or com
puted in accordance with this ordinance.
22 | Unified Development Review Ordinance
IMPERVIOUS SURFACE: The area of land covered by buildings, structures and paved
and gravel surfaces.
IMPERVIOUS SURFACE RATIO (ISR):
Is calculated by dividing the total square
footage of all impervious surfaces on a lot or project by the total square footage of the lot
area. It is often expressed as a percentage.
ISR=(
Total Areaof Impervious Surfaces(sq.ft .)
Total Lot Area(sq.ft .)
)×100
INCREASE IN NON CONFORMITY OF A STRUCTURE:
Any change in a structure or
property which causes further deviation from the dimensional standard(s) creating the
nonconformity such as, but not limited to, reduction in water body, tributary stream or wet
land setback distance, increase in lot coverage, or increase in height of a structure. Prop
erty changes or structure expansions which either meet the dimensional standard or
which cause no further increase in the linear extent of non-conformance of the existing
structure shall not be considered to increase nonconformity.
INDUSTRIAL:
Connected with the assembling, fabrication, finishing, manufacturing,
packaging, or processing of goods.
INSPECTING OFFICIAL: An individual or individuals appointed by the Select Board to
oversee all aspects of Required Improvements including road construction, drainage and
stormwater management. The Inspecting Official shall possess such education and train
ing that the Select Board deem necessary to perform all aspects of inspection.
INSTITUTIONAL:
A building devoted to some public, governmental, educational, chari
table, medical or similar purpose.
INTERSECTION SIGHT DISTANCE (ISD)
The distance a motorist should be able to
see other traffic operating on an intersecting roadway in order to safely:
1. Enter or cross the intersecting roadway.
2. Avoid or stop short of any unexpected conflicts in the intersection area.
ISD is calculated using the methodology set by the American Association of State High
way and Transportation Officials (AASHTO).
LAND BASED RECREATIONAL ACTIVITIES: It is the intention for these activities to in
clude recreation trails and transport and to provide safety and maintenance access or
equipment for these recreation trails or transport.
LINE OF SIGHT:
When referring to a Wireless Telecommunications Facility means the
direct view of the object from the Designated Scenic Resource.
LIQUIDATION HARVESTING:
The purchase or other acquisition of forestland followed
by a timber harvest that does not comply with Section 6 of the Maine Forest Service Rule-
May 12, 2026
Section: 3 | 23
Chapter 23 and the subsequent sale, offer for sale, or other conveyance of the harvested
land, or any portion of it, within five years.
LOCALLY-DESIGNATED PASSIVE RECREATION AREA:
Any site or area designated
by a municipality for passive recreation that is open and maintained for public use and
which:
1.
has fixed boundaries,
2.
is owned in fee simple by a municipality or is accessible by virtue of public
easement,
3.
is identified and described in a local comprehensive plan and,
4.
has been identified and designated at least nine months prior to the submission
of the Applicant's Commercial Wind Energy Facility permit application.
LOT:
An area of land in one ownership, or one leasehold, with ascertainable boundaries
established by deed or instrument of record, or a segment of land ownership defined by
lot boundary lines on a subdivision plan approved by the Planning Board and recorded in
the Registry of Deeds.
MAJOR SUBDIVISION, See Subdivision, Major.
MANUFACTURED HOUSING:
As defined in Title 30-A M.R.S.A. §4358 and as here
after amended.
MAXIMUM SOUND:
Largest A-weighted and fast exponential-time-weighted sound
during a specified time interval. Unit: pascal (Pa).
MAXIMUM SOUND LEVEL:
Ten times the common logarithm of the square of the ra
tio of the maximum sound to the reference sound of 20 micropascals. Symbol: LAFmax.
METEOROLOGICAL TOWER (MET TOWER):
A Tower used for the measurement
and collection of wind data that supports various types of equipment, including but not
limited to anemometers, data recorders, and solar power panels. MET Towers may also
include wildlife related equipment such as ANABAT detectors, bird diverts and wildlife en
tanglement protectors.
MINERAL EXTRACTION ACTIVITY:
An excavation or removal, handling or
storage of rock, minerals, or topsoil to include but not limited to quarries, mines, and rock
removal.
MINERAL EXTRACTION SITE OR AREA:
All of the land area disturbed or otherwise
developed for the extraction, removal, processing, or storage of minerals, stone, or rock;
including any access roads and cleared areas adjacent to a pit or excavated area.
24 | Unified Development Review Ordinance
MINOR SUBDIVISION, See Subdivision, Minor.
MOBILE HOME PARK:
A parcel of land under unified ownership approved as a subdi
vision for the placement of three or more manufacture homes.
MOTOR HOME: a motor vehicle that:
1.
Is originally designed, reconstructed or permanently altered to provide facilities
for human habitation; or
2.
Has a camper permanently attached to it.
MOUNTING
When referring to a Solar Energy System means the manner in which a
solar photovoltaic system is affixed to the roof or ground (i.e., roof mount, or ground
mount.
MULTI-UNIT DWELLING: A building or group of buildings consisting of three or more at
tached dwelling units.
MULTI-USER WATER SYSTEM: A system of pipes or other constructed conveyances,
structures and facilities through which water is obtained, furnished or distributed for hu
man consumption. The term includes any collection, treatment, storage or distribution
pipes or other constructed conveyances, structures or facilities under the control of the
supplier of water and used primarily in connection with such a system, and any collection
or pretreatment storage facilities not under that control that are used primarily in connec
tion with such a system. The system does not include the portion of service pipe owned
and maintained by user of the system.
NET RESIDENTIAL ACREAGE: The total acreage available for the subdivision or devel
opment, and shown on a subdivision or development plan, minus the area for roads or
access, easements (including right-of-ways) and the areas which are unsuitable for devel
opment.
NET RESIDENTIAL DENSITY:
The average number of dwelling units per net residential
acre.
NACELLE:
The frame and housing at the top of the tower that encloses the gearbox
and generator.
NGVD:
National Geodetic Vertical Datum.
NORMAL HIGH WATER LINE:
That line which is apparent from visible markings,
changes in the character of soils due to prolonged action of the water or changes in vege
tation, and which distinguishes between predominantly aquatic and predominantly terres
trial land. Areas contiguous with rivers that support non-forested wetland vegetation and
May 12, 2026
Section: 3 | 25
hydric soils and that are at the same or lower elevation as the water level of the river dur
ing the period of normal high-water are considered part of the river.
NON-CONFORMING LOT:
A single lot of record which, at the effective date of
adoption or amendment of this Ordinance, does not meet the area, frontage, or width re
quirements of the district in which it is located.
NON-CONFORMING STRUCTURE:
A structure which does not meet any one or more
of the following dimensional requirements; setback, height, or lot coverage, but which is
allowed solely because it was in lawful existence at the time this Ordinance or subse
quent amendments took effect.
NON-CONFORMING USE:
A use of buildings, structures, premises, land or parts
thereof which is not allowed in the district in which it is situated, but which is allowed to re
main solely because it was in lawful existence at the time this Ordinance or subsequent
amendments took effect.
NON-PARTICIPATING LANDOWNER: Any landowner, other than a Participating
Landowner.
OCCUPIED BUILDING:
A dwelling unit, school, hospital, house of worship, public li
brary or other building that is occupied or in use as a primary residence or is customarily
frequented by the public at the time when the permit application is submitted.
OFFICIAL SUBMITTAL DATE:
The date on which the entire application, supporting ma
terials, and application fee are provided to the town office.
OFF-SITE PARKING FACILITY: A legally established, non-appurtenant area that pro
vides required parking spaces for a development site located on a separate lot. An Off-
Site Parking Facility is established and governed by a Parking Agreement.
OFF-SITE PUBLIC ROAD:
Public roads not to be constructed as part of a develop
ment.
ONE-HUNDRED-YEAR FLOOD: The flood having a one percent chance of being
equaled or exceeded in any given year.
OPEN AREA:
Area not covered by an impervious surface, including but not limited to
grass, shrubs, mulch, trees or other comparable surface covers and existing vegetative
land and which is reserved for lawn, gardens, recreation or conservation.
OPEN SPACE:
See Open Area.
OUTDOOR RECREATION BASED SALES AND SERVICES:
A business establish
ment engaged in the sale, rental or lease of goods or services related to outdoor recre
ation.
26 | Unified Development Review Ordinance
PARKING AGREEMENT: A legally binding agreement, recorded with the Oxford County
Registry of Deeds, between a property developer and the owner of an Off-Site Parking
Facility to provide required parking spaces for a specific development site.
PARKING AREA:
Any mad-made, stabilized surface, whether impervious (such as as
phalt or concrete) or engineered pervious (such as structural gravel or reinforced turf) in
tended for the temporary or long-term parking, storage, or standing of two or more motor
vehicles. This term includes designated parking spaces, circulation aisles, loading areas,
and any required landscaping or drainage within the perimeter of the area used for park
ing.
PARTICIPATING LANDOWNER: One or more Persons that hold title in fee or a leasehold
interest with sublease rights to property on which Generating Facilities or Associated Fa
cilities or Development are proposed to be located pursuant to an agreement with the Ap
plicant or an entity that has entered into an appropriate agreement with the Applicant al
lowing the Applicant to demonstrate the requisite right, title and interest in such property.
PERSON:
Includes an individual, firm, association, partnership, trust, company, corpo
ration, municipal or other local government entity, quasi-municipal entity, state agency,
educational or charitable organization or institution or other legal entity.
PIT PRIVY:
An alternative toilet, consisting of a permanent structure placed over an ex
cavation where human waste is deposited.
PLANNED RESIDENCE: A Residence for which all applicable building and land use per
mits have been issued, provided that the time for beginning construction under such per
mits has not expired.
PLANNED UNIT DEVELOPMENT:
A planned unit development is a residential or
mixed-use land development which is developed under unified management; is planned
as a whole according to comprehensive and detailed plans, including roads, utilities, lots
or building sites, open space and preserved natural features, recreational facilities, and
design principles for proposed buildings; is reviewed and approved as a subdivision and
as a site plan by the Planning Board; may be developed in clearly identified stages; and
provides for the operation and maintenance of common facilities.
PLANNING BOARD:
The Planning Board of the Town of Newry, Maine, as created
by the Planning Board Ordinance.
POWER
The rate at which work is performed (the rate of producing, transferring, or
using energy). Power is measured in Watts (W), kilowatts (kW), Megawatts (MW), etc.
PRE-DEVELOPMENT AMBIENT:
The ambient sound at a specified location in the
vicinity of a facility site prior to the construction and operation of the proposed Commer
cial Wind Energy Facility, Development or expansion.
May 12, 2026
Section: 3 | 27
PRIMITIVE CAMPSITE:
A Recreational Lodging Facility unit in an undeveloped section
of the Recreational Lodging Facility with no facilities or amenities such as water, electric
ity or toilets/showers, where campers are expected to leave little or no evidence of human
visitation.
PRINCIPAL STRUCTURE:
A building other than one which is used for purposes
wholly incidental or accessory to the use of another building or use on the same
premises.
PRINCIPAL USE:
A use other than one which is wholly incidental or accessory to an
other use on the same premises.
PRIVATE ROAD (PRIVATE WAY):
Any road or way, other than Driveways or Vehicu
lar Entrances, providing access to three or more lots that has not been accepted by the
municipality as a Public Way. All Private Roads shall be constructed and improved in ac
cordance with the standards specified in this Ordinance and shall remain the responsibil
ity of the owners served thereby for maintenance and upkeep.
PROTECTED LOCATION:
Any location that is beyond the property boundary of the
applicant. In cases where Participating Landowner agreements exist, the property
boundary of the applicant may be extended as described in such documents.
PUBLIC RECREATIONAL FACILITY OR AREA:
Means a regionally or locally signifi
cant facility or area, as defined and identified either by State statute or in the Town's
adopted comprehensive plan or a municipal ordinance adopted by the Town, designed to
serve the recreational needs of municipal property owners.
PUBLIC ROAD: A road maintained with public funds
PUBLIC UTILITY FACILITIES:
Facilities needed to furnish electricity, waste disposal,
communication, transportation or water to the public. Public utility facility shall not include
commercial communication towers and related facilities.
PUBLIC WATER SUPPLY:
Any publicly or privately-owned system of pipes or other
constructed conveyances, structures and facilities through which water is obtained for or
sold, furnished or distributed to the public for human consumption, if such system has at
least 15 service connections or serves at least 25 individuals daily at least 60 days out of
the year or bottles water for sale. The term "public water system" shall include any collec
tion, treatment, storage or distribution pipes or other constructed conveyances, structures
or facilities under the control of the supplier of water and used primarily in connection with
such a system, and any collection or pretreatment storage facilities not under that control
that are used primarily in connection with such a system.
RECLAMATION:
The restoration or continued maintenance of the area of land affected
by mining under a reclamation plan. This may include but is not limited to, grading and
28 | Unified Development Review Ordinance
shaping of the land, the creation of lakes, ponds, or wetlands, the planting of forests, the
seeding of grasses, legumes, or crops for harvest, or the enhancement of wildlife and
aquatic resources.
RECLAMATION PLAN:
A plan which depicts how the project will be restored, or main
tained, after excavation is complete. Such a plan usually includes final grading and re-
vegetation plans, of any given phase.
RECORDING PLAN:
A copy of the Final Plan which is recorded at the Registry of
Deeds.
RECREATIONAL LODGING FACILITY - A facility which primarily caters to users who en
gage in recreation activities that are primarily natural resource based. The term includes,
but is not limited to, commercial sporting camps, youth or group camps, back-country
huts, rental cabins, outpost cabins, outdoor education institutions and campgrounds.
These facilities contain campsites of temporary or permanent structures including, without
limitation, tents, recreational vehicles, motor homes, cottages, cabins, yurts, tiny homes
and other types of shelter which are used or rented for sleeping purpose by tourist, tran
sients, students, staff, organization members or other visitors. Recreational Lodging Fa
cility includes, but is not limited to:
1.
any facility that is regulated by the State of Maine Department of Health and
Human Services (DHHS) Rules Related to Campgrounds (10-144 CMR 205).
2.
any facility that is regulated by the State of Maine Department of Health and
Human Services (DHHS) Rules Relating To Youth Camps, Primitive, And Trip
Camping (10-144 CMR 208).
Recreational Lodging Facility does not include hotel, motel, home occupation bed and
breakfast, individual private campsites, recreational facilities, residential dwelling unit or
the rental of a residential dwelling unit or of rooms in a residential dwelling unit.
RECREATIONAL LODGING FACILITY UNIT: Individual campsites within a Recreational
Lodging Facility.
RECREATIONAL VEHICLE:
A vehicle or an attachment to a vehicle designed to be
towed, and designed for temporary sleeping or living quarters for one or more persons,
and which may include a pick-up camper, travel trailer, tent trailer, camp trailer, and motor
home. In order to be considered as a vehicle and not as a structure, the unit must remain
with its tires on the ground, and must be registered with the State Division of Motor Vehi
cles.
REQUIRED IMPROVEMENTS:
Any and all infrastructure improvements shown on the
Final Plan. It includes, but is not limited to, roads, street lights, potable water systems,
May 12, 2026
Section: 3 | 29
fire protection, sewers and water treatment, stormwater management, utilities and struc
tures.
RESIDENCE:
see Dwelling Unit.
RESORT: A self contained complex developed as a single entity providing lodging facili
ties, recreation and services for transit quests.
RESORT BASED USES: Uses normally associated with a resort.
RESTAURANT: A commercial establishment where meals are prepared and served to
the public.
RESUBDIVISION:
The division of an existing subdivision or development or any change
in the plan for an approved subdivision or development which affects the lot lines, includ
ing land transactions by the subdivider not indicated on the Final Plan.
RETAIL:
Connected with the sale of goods to the ultimate consumer for direct use and
consumption and not for trade.
REVEGETATED:
That surface area that has been returned to its natural state as grass,
meadow, forest or agricultural use.
ROAD:
A strip of land or other area, regardless of the method of creation, that has
been dedicated or is used for vehicular access, ingress, and egress, and includes all as
sociated rights-of-way, whether formally accepted, publicly maintained, or privately owned
and constructed. The term specifically includes, but is not limited to, the entire width of
the right-of-way, including the traveled surface, shoulders, drainage ditches, and slopes.
Does not include Driveways.
ROAD CLASSIFICATION:
1.
NEIGHBORHOOD ROAD:A road having a minimum 50' right-of-way with a
travel way width of at least 18 feet and 2' wide shoulder on each side. A neigh
borhood road shall serve small residential areas with a maximum speed of 25
mph. The road shall be within a subdivision, and is not intended to allow thru
traffic. No more than 65 lots and/or individual dwelling units shall be served by
a neighborhood road or roads.
2.
PRIMARY ROAD:
A road having a minimum 60' right-of-way with a travel way
width of at least 22' and 4' wide shoulder on each side for a total width of 30'
from outside to outside of the shoulders.
3.
SECONDARY ROAD:
A road having a minimum 50' right-of-way with a
travel way width of at least 20' and 2' wide shoulder on each side with a maxi
mum length of 15,000'. A secondary road will serve an area intended primarily
30 | Unified Development Review Ordinance
for residential use, and serve as the means to access no more than 200 lots
and/or individual dwelling units per connection with a Primary road. This num
ber shall include lots and/or individual dwelling units on other roads whose only
access is via this secondary road. A secondary road shall have a maximum
speed limit of 35 mph.
ROUTINE OPERATION:
Regular and recurrent operation of regulated sound sources
associated with the purpose of the Commercial Wind Energy Facility and operating on the
facility site.
SAWMILL:
A commercial facility where logs or bolt wood are sawn, split, shaved,
stripped, chipped or otherwise processed to produce wood products. The term saw mill
does not include slashing or chipping at the harvest site.
SCENIC RESOURCE:
Either a Scenic Resource of state or national significance, as
defined in 35-A M.R.S §3451(9) or a scenic resource of local significance located within
the municipality and identified as such in a comprehensive plan, open space plan or
scenic inventory adopted by the municipal legislative body.
STOPPING SIGHT DISTANCE (SSD): The minimum length of roadway a driver must be
able to see ahead to bring their vehicle to a complete and safe stop before colliding with a
stationary object in the travel lane. SSD is calculated using the methodology set by the
American Association of State Highway and Transportation Officials (AASHTO).
SERVICE BUSINESS:
Establishments engaged in providing services for individuals
and businesses such as laundries, beauty shops, barbershop, advertising and equipment
leasing.
SEWAGE TREATMENT SYSTEM:
A municipal or private system for treating sewage
which is an overboard discharge system.
SEWERED: Serviced by an underground conduit that carries wastewater to an off-site
sewage treatment system.
SHADOW FLICKER:
Alternating changes in light intensity caused by the movement
of Wind Turbine blades casting shadows on the ground or a stationary object.
SHORT DURATION REPETITIVE SOUNDS:
A sequence of repetitive sounds which oc
cur more than once within an hour, each clearly discernible as an event and causing an
increase in the sound level of at least 6 dBA on the fast meter response above the sound
level observed immediately before and after the event, each typically less than ten sec
onds in duration, and which are inherent to the process or operation of the facility and are
foreseeable.
May 12, 2026
Section: 3 | 31
SIGHT LINE REPRESENTATION:
A profile drawing showing prominent features, in
cluding but not limited to topography, buildings, and trees, along and in relation to a line of
sight extending from an observer's eye to the lowest point visible on a proposed Tower.
SIGN:
An object, device or structure, or part thereof, situated outdoors, visible from a
public road, free standing or attached, which is used to advertise, identify, display, direct
or attract attention to an object, person, institution, organization, business, product, ser
vice, event or location, by any means including words, letters, figures, design, symbols,
advertising flags, fixtures, colors, illuminations or projected images. Each substantially
different face of a sign shall constitute a separate sign.
SIGNIFICANT WILDLIFE HABITAT:
A Significant Wildlife Habitat as defined in 38
M.R.S. §480-B(10).
SITE PLAN: A plan showing the proposed layout of lots, buildings, roads, parking, land
scaping, and other required improvements.
SOLAR ARRAY:
Multiple solar photovoltaic panels or thermal collector panels com
bined together to create one system.
SOLAR COLLECTOR:
A solar photovoltaic cell, panel, or array, or solar thermal col
lector device, that relies upon solar radiation as an energy source for the generation of
electricity or transfer of heat.
SOLAR ENERGY SYSTEM (SES):
A system whose primary purpose is to harvest
energy by transforming solar energy into another form of energy or transferring heat from
a collector to another medium using mechanical, electrical, or chemical means. It may be
roof-mounted or ground-mounted, and may be of any size as follows:
1.
Small-scale Solar Energy System is one whose physical size based on total
airspace projected over a roof or the ground is less than 15,000 square feet
(approximately one-third of an acre);
2.
Medium-scale Solar Energy System is one whose physical size based on total
airspace projected over a roof or the ground is equal to or greater than 15,000
square feet but less than 87,120 square feet (two acres); and
3.
Large-scale Solar Energy System is one whose physical size based on total
airspace projected over a roof or the ground is equal to or greater than 87,120
square feet (two acres).
SOLAR ENERGY SYSTEM, GROUND-MOUNTED: A Solar Energy System that is struc
turally mounted to the ground and is not roof-mounted; may be of any size (small-,
medium- or large-scale).
32 | Unified Development Review Ordinance
SOLAR ENERGY SYSTEM, ROOF-MOUNTED:
A Solar Energy System that is
mounted on the roof of a building or structure; may be of any size (small-, medium- or
large-scale).
SOUND COMPONENT:
The measurable sound from an audibly identifiable source or
group of sources.
SOUND LEVEL: Ten times the common logarithm of the square of the ratio of the fre
quency-weighted and time-exponentially averaged sound pressure to the reference
sound of 20 micropascals. For the purpose of this ordinance, sound level measurements
are obtained using the A-weighted frequency response and fast dynamic response of the
measuring system, unless otherwise noted.
SOUND PRESSURE:
Root-mean-square of the instantaneous sound pressures in a
stated frequency band and during a specified time interval. Unit: pascal (Pa).
SOUND PRESSURE LEVEL:
Ten times the common logarithm of the square of the ra
tio of the sound pressure to the reference sound pressure of 20 micropascals.
STREAM:
Means a channel between defined banks. A channel is created by the ac
tion of surface water and has two (2) or more of the following characteristics.
1.
It is depicted as a solid or broken blue line on the most recent edition of the
U.S. Geological Survey 7.5-minute series topography map or if that is not
available, a 15-minute series topography map.
2.
It contains or is known to contain flowing water continuously for a period of at
least 3 months of the year in most years.
3.
The channel bed is primarily composed of material such as sand and gravel,
parent material or bedrock that has been deposited or scoured by water.
4.
The channel contains aquatic animals such as fish, aquatic insects or mollusks
in the water or, if no surface water is present in the stream bed.
STRUCTURE:
Anything temporarily or permanently located, placed, built or con
structed. The term includes structures temporarily or permanently located, such as
decks, patios, and satellite dishes. Structure does not include fences; poles and wiring
and other aerial equipment normally associated with service drops, including guy wires
and guy anchors; lift towers for skier transport; subsurface waste water disposal systems
as defined in Title 30-A, §4201(5); geothermal heat exchange wells as defined in Title 32,
§4700-E(3-C); or wells or water wells as defined in Title 32, §4700-E(8).
SUBDIVIDER:
The person, or persons proposing a subdivision as defined in this ordi
nance.
May 12, 2026
Section: 3 | 33
SUBDIVISION: A subdivision is defined by Title 30-A MRSA §4401.
SUBDIVISION, MAJOR:
Any subdivision of 10 or more lots and/or dwelling units.
SUBDIVISION, MINOR:
Any subdivision with less than 10 lots and/or dwelling units.
SUBSTANTIAL ENLARGEMENT:
Any expansion of the land area of the develop
ment site by more than 25% at any one time of in total since the effective date of this ordi
nance.
SUBSTANTIALLY COMPLETED: Completion of at least 80% of the Required Improve
ments measured as a percentage of total estimated cost of such improvements.
TARGETED MARKET COVERAGE AREA:
means the portion(s) of the Town of Newry
that are targeted to be served by a proposed Wireless Telecommunications Facility.
TILT:
The angle of the solar panels and/or solar collector relative to horizontal. Tilt is
often between 5 and 40 degrees. Solar energy systems can be manually or automatically
adjusted throughout the year. Alternatively, fixed-tilt systems remain at a static tilt year-
round.
TIMBER HARVESTING:
The cutting and removal of timber for the primary purpose of
selling or processing forest products.
TIMBER HARVESTING ACTIVITIES:
Timber harvesting, the construction and mainte
nance of roads used primarily for timber harvesting and other activities to facilitate timber
harvesting.
TINY HOME:
a living space permanently constructed on a frame or chassis and de
signed for use as temporary or permanent living quarters that:
1.
Complies with American National Standards Institute standard A 119.5 on
plumbing, propane, fire and life safety and construction or National Fire Protec
tion Association standard 1192 on plumbing, propane and fire and life safety for
recreational vehicles;
2.
Does not exceed 400 square feet in size;
3.
Does not exceed any dimension allowed for operation on a public way in the
State of Maine; and
4.
Is a vehicle without motive power.
Tiny Home does not include a trailer, semitrailer, camp trailer, recreational vehicle, motor
home or manufactured housing.
34 | Unified Development Review Ordinance
TONAL SOUND:
A tonal sound exists if, at a Protected Location, the one-third octave
band sound pressure level in the band containing the tonal sound exceeds the arithmetic
average of the sound pressure levels of the two contiguous one-third octave bands by 5
dB for center frequencies at or between 500 Hz and 10,000 Hz, by 8 dB for center fre
quencies at or between 160 and 400 Hz, and by 15 dB for center frequencies at or be
tween 25 Hz and 125 Hz.
TOWER: The free-standing structure on which a wind measuring or energy conversion
system is mounted.
TOWN:
Means the Town of Newry.
TOWN ROAD:
A town way as defined in Title 23 M.R.S. §3021(3) or public easement as de
fined in Title 23 M.R.S. §3021(2) and §3022.
TRACT OR PARCEL OF LAND: all contiguous land in the same ownership provided that
lands located on opposite sides of a public or private road shall be considered each a
separate tract or parcel of land unless such road was established by the owner of land on
both sides after September 22, 1971.
TURBINE HEIGHT: The distance measured from the surface of the Tower foundation to
the highest point of any turbine rotor blade measured at the highest arc of the blade.
UNREASONABLE ADVERSE IMPACT UPON A DESIGNATED SCENIC RESOURCE:
Means that the proposed project would produce an end result that is:
1.
excessively out of character with the Designated Scenic Resources affected,
including existing buildings, structures and features within the Designated
Scenic Resource, and
2.
would significantly diminish the scenic value of the Designated Scenic Re
source.
VAULT PRIVY:
An alternative toilet that retains human waste in a sealed vault.
VEHICULAR ENTRANCE:
An access way, service drive, or private road that con
nects a Commercial Use or multi-unit dwelling to an existing public or private way. A Ve
hicular Entrance shall be considered the entire continuous length of the access drive from
the edge of the traveled way of the main road to the nearest point of the principal parking
area or the point where the drive bifurcates (splits) to serve individual units. For the pur
poses of this Ordinance, a Vehicular Entrance shall not exceed a maximum length of
three hundred (300) feet from the edge of the traveled way of the public or private road it
accesses. Access drives exceeding this length shall be regulated as a Private Road and
shall be subject to all applicable subdivision or road standards and permitting require
ments.
May 12, 2026
Section: 3 | 35
VIEWPOINT:
Means that location which is identified either in the municipally adopted
comprehensive plan or a municipal ordinance adopted by the Town or by a federal or
State agency, and which serves as the basis for the location and determination of a par
ticular Designated Scenic Resource.
VIGOROUS (Related to Buffer and Screening):The capacity of a plant or tree to be
healthy and to grow in a normal growth pattern over time for its species, such as foliage
volume, height, girth, etc., while enduring environmental stress and strain.
VISIBLE: Capable of being seen without visual aid by a person of normal visual acuity.
WAY:
See Road.
WHOLESALE BUSINESS:
The use of land and/or buildings engaged I the selling of
merchandise to retailers, industry, commercial, institutional or professional businesses or
other wholesalers as distinguished from the sale to the general public.
WIND ENERGY FACILITY:
A facility that uses one or more Wind Turbines to con
vert wind energy to electrical energy
WIND TURBINE:
A system for the conversion of wind energy into electricity which is
comprised of a Tower, generator, Nacelle, rotor and transformer.
WIRELESS TELECOMMUNICATION FACILITY:
Means any structure, antennas,
tower, or other devise which provides commercial mobile wireless services, cellular tele
phone services, specialized mobile radio communications (SMR), common carrier wire
less exchange access services, personal communications service (PCS) or pager ser
vices, and internet services.
36 | Unified Development Review Ordinance
SECTION 4:
ADMINISTRATION
SECTION USER'S GUIDE: This section contains provisions for the administration
of this Ordinance including specific provisions for certificates of compliance, con
ditions of approval, and public hearings.
A.
ADMINISTERING BODY
The Planning Board of the Town of Newry shall administer this Ordinance. No building
permit or plumbing permit shall be issued by the Select Board or Code Enforcement Offi
cer for any use or development within the scope of this Ordinance until an application re
quired by this Ordinance has been reviewed and approved by the Planning Board.
B.
APPROVAL REQUIRED
After the effective date of this Ordinance or amendment thereto, no person shall engage
in any activity requiring a permit under this Ordinance without first obtaining the approval
of the Planning Board or Code Enforcement Officer as required.
C.
APPLICATION REQUIRED
Applications for approval shall be submitted in writing to the Planning Board, on forms
provided by it. The Planning Board has the right to require the submission of whatever
additional information is necessary to determine compliance with the provisions of this Or
dinance.
D.
OTHER PERMITS REQUIRED
Applications for approval under this Ordinance will be considered separately and concur
rently with all other required local, state, and federal permits which have been applied for.
Evidence that they have been applied for and/or acquired must be provided to the Plan
ning Board at the time of application. These may include but not be limited to the follow
ing:
1.
Maine Department of Environmental Protection, under the Site Location of De
velopment Act, Natural Resources Protection Act, or if a waste water discharge
license is needed.
2.
Maine Department of Human Services, if the applicant proposes to provide a
public water system.
3.
Maine Department of Human Services, if an engineered subsurface waste wa
ter disposal system(s) is to be utilized.
4.
U.S. Army Corps of Engineers, if a permit under Section 404 of the Clean Wa
ter Act is required.
May 12, 2026
Section: 4 | 37
5.
An approved Driveway or Entrance permit issued by the Maine Department of
Transportation if a driveway or entrance will enter onto Routes 2 and 26 or the
Sunday River Road to the Ski Way Road.
No building or use permits for a development approved under this Ordinance shall be
granted until proof is provided that any and all state and federal permit have been ob
tained.
E.
START AND COMPLETION OF CONSTRUCTION
Construction and alteration activities for which approval has been granted under this Ordi
nance shall commence within twenty-four (24) months of the date of issuance of Planning
Board approval for projects under Local review or shall commence within thirty-six (36)
months of the date of issuance for projects under State or Federal review and shall be
substantially complete within eighteen (18) months of the date of commencement.
At the time the Planning Board grants Final Plan approval, it may permit the Plan to be di
vided into two or more phases subject to any conditions the Planning Board deems nec
essary in order to ensure the orderly development of the Plan. If any municipal, quasi-
municipal department head, or superintendent of schools notified of the proposed Plan in
forms the Planning Board that their department or district does not have adequate capital
facilities to service the proposed Plan, the Planning Board may require the Plan to be di
vided into two or more phases subject to any conditions the Planning Board deems nec
essary in order to allow the orderly planning, financing and provision of public services to
the proposed Plan.
If a project is subject to phasing, a phasing time line for commencement and completion
of each phase shall be shall be approved by the Planning Board. The Planning Board
may agree on a phasing time line which lasts for no more than ten (10) years after the
date of approval at which time all project activities must be substantially completed.
Activities which are not commenced or substantially completed within the time limits pro
vided above shall be subject to new application and the original approval issued under
this ordinance shall be considered void. The new application shall be accompanied by a
re-application fee as per the Town's Fee Schedule. In the event the new application dif
fers substantially from the original submission, the Planning Board, at its discretion, may
require the applicant to pay an additional fee to aid the Planning Board in its review of the
new submission. Said additional fee shall be either 50% of the application fee or
$10,000, whichever is greater and shall be held in a non-interest bearing escrow account
("The Account"). If the balance of The Account is drawn down by 75%, the Board shall re
quire 50% of the original additional fee to be paid by the applicant. Any unused portion of
escrow account will be returned to the Applicant.
38 | Unified Development Review Ordinance
Activities may be extended for up to one (1) year by the Planning Board if the application
for extension is submitted not later than thirty (30) days prior to expiration. Activities may
be approved in phases of longer periods of time if preapproved by the Planning Board.
When future phases do commence, those phases must meet life safety town ordinances
in effect at that time, including the Building Code Ordinance sections that address chim
neys, fireplaces, vents and fuel burning appliances, electrical wiring, means of egress,
safety detection and suppression systems (e.g. detection systems for smoke, radon, car
bon monoxide, sprinklers, etc.) and portions of this ordinance which address Life Safety
and Fire Suppression, and as amended or combined.
F.
CONDITIONS OF APPROVAL
The Planning Board may in approving applications attach such conditions of approval, in
addition to those required elsewhere in this Ordinance, that it finds necessary to further
the purposes of this Ordinance. Such conditions of approval may include, but are not lim
ited to, specifications for:
1.
Type of vegetative cover;
2.
Increased setbacks or dimensional requirements;
3.
Specific sewage or other waste disposal facilities;
4.
Specific water supply facilities;
5.
Landscaping and planting screen;
6.
Periods of operation;
7.
Operational controls;
8.
Professional inspection and maintenance;
9.
Specific storage and display requirements;
10.
Sureties and bonds;
11.
Restrictive covenants;
12.
Location of piers, docks, parking areas and signs;
13.
Type of construction; and
14.
Any other term or condition of approval necessary to fulfill the purposes of this
Ordinance.
The Planning Board may, as a term or condition of approval, establish any reasonable re
quirement to ensure that the Applicant has made adequate provision for the control of
May 12, 2026
Section: 4 | 39
noise from the facility and to reduce the impact of noise on Protected Locations. Such
conditions may include, but are not limited to, enclosing equipment or operations, impos
ing limits on hours of operation, or requiring the employment of specific design technolo
gies, site design, modes of operation, or traffic patterns.
The sound level limits prescribed in this ordinance shall not preclude the Planning Board
from requiring an Applicant to demonstrate that sound levels from a facility will not unrea
sonably disturb wildlife or adversely affect wildlife populations. In addition, the sound
level limits shall not preclude the Planning Board as a term or condition of approval, from
requiring that lower sound level limits be met to ensure that the Applicant has made ade
quate provision for the protection of wildlife.
Violation of any conditions of approval shall be considered a violation of this Ordinance.
G.
PUBLIC HEARINGS
In scheduling public hearings under this ordinance, the Planning Board shall publish no
tice of the hearing at least seven (7) days in advance of the hearing in a newspaper of
general circulation in the area at least two (2) times and shall post such notice in at least
two (2) conspicuous public places at least seven (7) days in advance of the hearing.
The Applicant shall notify, by mail, and provide the board with certified mail receipts, all
property owners within one thousand feet (1,000') of the project site, including owners of
property on the opposite side of the road, at least ten (10) days in advance of the hearing,
of the nature of the application and of the time and place of the public hearing. The own
ers of property shall be considered to be those against whom taxes are assessed. For
the purpose of this section when an abutter is a condominium, the President of the Con
dominium Association shall be notified. ,
At any hearing, a party may be represented by agent or attorney. Hearings shall not be
continued to other times except for good cause. The applicant's case shall be heard first.
To maintain orderly procedure, each side shall proceed without interruption.
Questions may be asked through the Chair. All persons at the hearing shall abide by the
order of the Chairman of the Planning Board or designated public officer. Within thirty
(30) days of the public hearing, or within any other time limit that is otherwise mutually
agreed to, the Planning Board shall reach a decision on the proposed development plan
and shall inform the applicant and the Select Board in writing within seven (7) days of its
decision stating its reasons. The Planning Board shall prepare detailed, written findings
of fact, based on; sufficient evidence presented at the public hearing, as well as its con
clusions and the reasons or basis thereof; and said findings shall not be based on feel
ings or unsubstantiated allegations, but upon all reasonable evidence.
40 | Unified Development Review Ordinance
H.
PERMIT TRANSFERS
A permit received pursuant this Ordinance is freely transferable provided that:
1.
If the project was subject to the Site Location of Development Law, 38 M.R.S.A.
§481, the transferee has satisfied the Department of Environmental Protection
that the financial and technical criteria to undertake the project has been met;
and
2.
The transferee has submitted information to the Planning Board which demon
strates adequate technical and financial capacity to complete the proposed
project.
May 12, 2026
Section: 4 | 41
SECTION 5:
CRITERIA OF APPROVAL
SECTION USER'S GUIDE: This section contains the criteria by which the Planning
Board will judge all applications submitted pursuant to this Ordinance.
In approving applications submitted pursuant to this Ordinance, the Planning Board shall
consider the following criteria, and find that the proposed development:
A.
POLLUTION
The proposed development will not result in undue water or air pollution. In making this
determination, it shall at least consider:
1.
The elevation of the land above sea level and its relation to the flood plains;
2.
The nature of soils and subsoils and their ability to adequately support waste
disposal;
3.
The slope of the land and its effect on effluents;
4.
The availability of streams for disposal of effluents; and
5.
The applicable state and local health and water resource rules and regulations;
B.
EROSION
The proposed development will not cause unreasonable soil erosion or a reduction in the
land's capacity to hold water so that a dangerous or unhealthy condition results;
C.
TRAFFIC
The proposed development will not cause unreasonable highway or public road conges
tion or unsafe conditions with respect to the use of the highways or public roads existing
or proposed. If the proposed development requires driveways or vehicular entrances onto
a state or state aid highway (Route 2, Route 26 and the Sunday River Road to the Ski
Way Road) the Maine Department of Transportation has provided documentation indicat
ing that the driveways or entrances conform to Title 23 section 704 and any rules adopted
under that section. If the proposed development requires driveways or vehicular en
trances onto a town road, the town has approved the driveway or vehicular entrance and
confirmed that it conforms to town requirements for driveways or vehicular entrances;
D.
SEWAGE DISPOSAL
The proposed development will provide for adequate sewage waste disposal and will not
cause an unreasonable burden on municipal services if they are utilized;
May 12, 2026
Section: 5 | 43
E.
MUNICIPAL SOLID WASTE DISPOSAL
The proposed development will not cause an unreasonable burden on the Town's ability
to dispose of solid waste. Use of Town services for the disposal of construction and de
molition debris is not allowed except under §18.R.
F.
AESTHETIC, CULTURAL AND NATURAL VALUES
The proposed development will not have an undue adverse effect on the scenic or natural
beauty of the area, aesthetics, historic sites, significant wildlife habitat identified by the
Department of Inland Fisheries and Wildlife or the Town, or rare and irreplaceable natural
areas or any public rights for physical or visual access to the shoreline;
G.
FINANCIAL AND TECHNICAL CAPACITY
The applicant has adequate financial and technical capacity to meet the standards of this
Ordinance;
H.
SUFFICIENT WATER
The proposed development has sufficient water available for its reasonably foreseeable
needs;
I.
PUBLIC WATER SUPPLY
The proposed development will not cause an unreasonable burden on an existing public
water supply, if one is to be used;
J.
SURFACE WATERS
Whenever situated entirely or partially within the watershed of any pond or lake or within
250 feet of any wetland, great pond or river as defined in Title 38, chapter 3, subchapter I,
article 2-B1, the proposed development will not adversely affect the quality of that body of
water or unreasonably affect the shoreline of that body of water;
K.
GROUND WATER
The proposed development will not, alone or in conjunction with existing activities, ad
versely affect the quality or quantity of ground water;
L.
FLOOD AREAS
Based on the Federal Emergency Management Agency's Flood Boundary and Floodway
Maps and Flood Insurance Rate Maps and information presented by the applicant
whether the development is in a flood-prone area. If the development, or any part of it, is
in such an area, the developer shall determine the 100-year flood elevation and flood
hazard boundaries within the development. The proposed development plan must in
44 | Unified Development Review Ordinance
clude a condition of plan approval requiring that principal structures in the development
will be constructed with their lowest floor, including the basement, at least one foot above
the 100-year flood elevation;
M.
FRESHWATER WETLANDS
All freshwater wetlands within the proposed development have been identified on any
maps submitted as part of the application, regardless of the size of these wetlands. Any
mapping of freshwater wetlands may be done with the help of the local soil and water
conservation district;
N.
RIVER, STREAM OR BROOK
Any river, stream or brook within or abutting the proposed development has been identi
fied on any maps submitted as part of the application. For purposes of this section, "river,
stream or brook" has the same meaning as in Title 38, Section 480-B, subsection 9;
O.
STORM WATER
The proposed development will provide for adequate storm water management;
P.
SPAGHETTI-LOTS PROHIBITED
If any lots in the proposed development have shore frontage on a river, stream, or brook
as these features are defined in Title 38, section 480-B, none of the lots created within the
development have a lot depth to shore frontage ratio greater than 5 to 1 (i.e. to create a
lot 1,000-feet deep, the lot must have a minimum of 200-feet of shore frontage, for a
deeper lot the shore frontage would need to be greater);
Q.
MUNICIPAL SERVICES
The proposed development will not place unreasonable burden on the town's municipal
services including but not limited to the Newry Fire Department or the local school sys
tem;
R.
LAKE PHOSPHORUS CONCENTRATION
The long term cumulative effects of the proposed development will not unreasonably in
crease Howard Pond phosphorus concentration during the construction phase and life of
the proposed development;
S.
IMPACT ON ADJOINING MUNICIPALITY
For any proposed development that crosses municipal boundaries, the proposed devel
opment will not cause unreasonable traffic congestion or unsafe conditions with respect to
the use of existing public roads in an adjoining municipality in which part of the develop
ment is located;
May 12, 2026
Section: 5 | 45
T.
LANDS SUBJECT TO LIQUIDATION HARVESTING
Timber on the parcel being developed has not been harvested in violation of rules
adopted pursuant to Title 12, section 8869, subsection 14. If a violation of rules adopted
by the Maine Forest Service to substantially eliminate liquidation harvesting has occurred,
the planning board must determine prior to granting approval for the development that
five (5) years have elapsed from the date the landowner under whose ownership the har
vest occurred acquired the parcel; and
U.
CONFORMITY WITH LOCAL ORDINANCES AND PLANS
The proposed development conforms with a duly adopted subdivision regulation or ordi
nance, comprehensive plan, development plan or land use plan, if any. In making this de
termination, the Planning Board may interpret these ordinances and plans.
46 | Unified Development Review Ordinance
SECTION 6:
INSPECTION, VIOLATION AND ENFORCEMENT
SECTION USER'S GUIDE: This section contains specific provisions outlining the
inspection of Required Improvements and those actions which shall be consid
ered violations of this Ordinance and provisions for enforcement. It also provides
that contractors and property owners shall be held liable for their actions which
are in violation of this Ordinance.
A.
INSPECTION
1.
Appointment of Inspecting Official:
a.
The Select Board shall have the responsibility of approving the Inspecting
Official. If an Inspecting Official is not approved by the Select Board at
least five (5) days prior to commencing construction of Required Improve
ments the Code Enforcement Officer will act as the Inspecting Official.
b.
As part of the application review process the Planning Board and/or the
Code Enforcement Officer may make recommendations to the Select
Board regarding the selection of the individual or individuals to serve in
this capacity.
c.
The Inspecting Official shall possess the education and training that the
Select Board deems necessary to oversee all aspects of Required Im
provements, including road construction, drainage, and stormwater man
agement.
d.
The Inspecting Official shall be responsible for observing all on-site and
off-site construction of Required Improvements and shall provide periodic
reports to the Select Board, Planning Board, and Code Enforcement Offi
cer.
2.
Notification of Construction: At least five (5) days prior to commencing con
struction of Required Improvements, the applicant shall.
a.
Notify the Code Enforcement Officer and/or Inspecting Official in writing of
the time when (s)he proposes to commence construction so that the Mu
nicipal Officers can arrange for inspection to be made. The Inspecting Of
ficial shall assure that all municipal specifications, requirements and con
ditions of approval shall be met during the construction and shall assure
the satisfactory completion of Required Improvements required by the
Planning Board.
b.
Deposit with the Municipal Officers a check for the amount of 2% of the
estimated costs of Required Improvements or $10,000, which ever is
May 12, 2026
Section: 6 | 47
greater, to pay for the costs of inspection. This deposit shall not be re
quired should the Code Enforcement Officer be the Inspecting Official. If
upon satisfactory completion of construction and cleanup there are funds
remaining, the surplus funds shall be refunded to the applicant within 30
days. If the inspection account shall be drawn down by 90%, the appli
cant shall deposit an additional 1% of the estimated costs of construction
and improvements or $10,000, whichever is greater.
3.
The Inspecting Official shall be responsible for observing all on-site and off-site
construction of Required Improvements. The Inspecting Official shall prepare
periodic reports and provide the same to the Select Board, Planning Board and
Code Enforcement Officer. The Inspecting Official shall have no enforcement
authority but is authorized to request the Code Enforcement Officer to take en
forcement actions as necessary to ensure compliance including Stop Work or
ders.
4.
Noncompliance With Final Plan: Upon finding that the Required Improvements
have not been constructed in accordance with the Final Plan and specifica
tions, the Inspecting Official shall so report in writing to the Municipal Officers,
Planning Board, Code Enforcement Officer and Applicant. The Municipal Offi
cers shall take any steps necessary to assure compliance with Final Plans.
5.
Modification During Construction: If at any time it appears necessary or desir
able to modify the Required Improvements before or during construction, the
Inspecting Official is authorized to approve minor modifications due to unfore
seen circumstances such as encountering hidden outcrops of bedrock, natural
springs, etc. The Inspecting Official shall issue any approval under this section
in writing and shall transmit a copy of the approval to the Municipal Officers,
Planning Board and Code Enforcement Officer. Revised plans shall be filed
with the Planning Board for the record. For major modifications, such as relo
cation of rights-of-way, changes in grade by more than 1%, etc., the applicant
shall submit to the Planning Board an amended application for review and ap
proval.
B.
RECORDING OF SUBDIVISION PLAN WITHOUT APPROVAL PROHIBITED
No plan of a division of land or structure within the municipality which would constitute a
subdivision shall be recorded in the Registry of Deeds until a Final Plan has been ap
proved by the Planning Board in accordance with this Ordinance.
C.
CONVEYANCE WITHOUT APPROVAL PROHIBITED
No person may convey any land or dwelling in a subdivision which has not been ap
proved as required by this Ordinance.
48 | Unified Development Review Ordinance
D.
CONVEYANCE WITHOUT RECORDING PROHIBITED
No person may convey any land or dwelling unit in a subdivision which has not been ap
proved by the Planning Board and recorded in the Registry of Deeds.
E.
CONVEYANCE OF LOTS OR DWELLING UNITS NOT SHOWN ON FINAL PLAN
PROHIBITED
No person may convey any land or dwelling units in an approved subdivision which is not
shown on the Final Plan as a separate lot or dwelling.
F.
UTILITY HOOKUPS PRIOR TO APPROVAL PROHIBITED
No public utility, water district, sanitary district or any utility company of any kind shall
serve any lot or dwelling unit in a subdivision or building in a development for which a Fi
nal Plan has not been approved by the Planning Board, except for utilities needed for
testing and exploration.
G.
ROAD COMPLETION PRIOR TO CONVEYANCE REQUIRED
No lot or dwelling in a subdivision may be sold, leased, occupied or otherwise conveyed
before the road upon which the lot fronts and access is gained is completed for the entire
frontage of the lot in accordance with this Ordinance and Final Plan as determined by the
Inspecting Official. This provision shall not apply when a performance guarantee has
been issued and accepted by the Municipality, except that the requirements of §12 must
be met.
H.
LIFE SAFETY AND FIRE SUPPRESSION PRIOR TO CONVEYANCE REQUIRED
No lot or unit in a subdivision may be conveyed prior to proof is provided to the Town that
Life and Fire Suppression standards, as required by the Final Plan and §25, has been
satisfied.
I.
FAILURE TO COMPLY WITH CONDITIONS OF APPROVAL
Failure to comply with any conditions of approval shall be construed to be a violation of
this Ordinance and may be grounds for revoking the approved development plan, initiat
ing legal proceedings to enjoin construction development or any specific activity violating
the conditions of permit approval or applying the legal penalties provided herein.
J.
OWNER RESPONSIBLE FOR OFF-SITE SEDIMENTATION
Whenever sedimentation is caused by stripping vegetation, re-grading or other develop
ment, it shall be the responsibility of the owner to remove sediment from all adjoining sur
faces, intermittent drainage systems and to repair any drainage, at his expense. Failure
May 12, 2026
Section: 6 | 49
to do so within two (2) weeks after official notification by the Code Enforcement Officer
shall be considered a violation of this Ordinance.
K.
NUISANCES
Any violation of this Ordinance shall be deemed a nuisance.
L.
CODE ENFORCEMENT OFFICER
1.
It shall be the duty of the Code Enforcement Officer to enforce the provisions of
this Ordinance. If the Code Enforcement Officer shall find that any provision of
this Ordinance is being violated, he or she shall notify in writing the person re
sponsible for such violation, indicating the nature of the violation and ordering
the action necessary to correct it, including discontinuance of illegal use of
land, buildings or structures, or work being done, removal of illegal buildings or
structures, and abatement of nuisance conditions. A copy of such notices shall
be submitted to the municipal officers and be maintained as a permanent
record.
2.
The Code Enforcement Officer shall conduct on-site inspections to insure com
pliance with all applicable laws and conditions attached to permit approvals.
The Code Enforcement Officer shall also investigate all complaints of alleged
violations of this Ordinance.
3.
The Code Enforcement Officer shall keep a complete record of all essential
transactions of the office, including applications submitted, permits granted or
denied, variances granted or denied, revocation actions, revocation of permits,
appeals, court actions, violations investigated, violations found, and fees col
lected.
M.
LEGAL ACTIONS
When the above action does not result in the correction or abatement of the violation or
nuisance condition, the Municipal Officers, upon notice from the Code Enforcement Offi
cer, are hereby directed to institute any and all actions and proceedings, either legal or
equitable, including seeking injunctions of violations and the imposition of fines, that may
be appropriate or necessary to enforce the provisions of this Ordinance in the name of
the municipality. The municipal officers, or their authorized agent, are hereby authorized
to enter into administrative consent agreements for the purpose of eliminating violations
of this Ordinance and recovering fines without Court action. Such agreements shall not
allow an illegal structure or use to continue unless there is clear and convincing evidence
that the illegal structure or use was constructed or conducted as a direct result of erro
neous advice given by an authorized municipal official and there is no evidence that the
owner acted in bad faith, or unless the removal of the structure or use will result in a
50 | Unified Development Review Ordinance
threat or hazard to public health and safety or will result in substantial environmental
damage.
N.
FINES
Any person who continues to violate any provision of this Ordinance after receiving writ
ten notice of such violations shall be guilty of a Civil Violation and subject to a minimum
fine of one hundred dollars ($100.00) up to a maximum fine to five thousand dollars
($5,000.00) for each violation, except that the maximum penalty for starting construction
or commencing a land use activity without a required permit is two thousand five hundred
dollars (2,500.00). Each day such violation is continued is a separate offense. All such
fines shall accrue to the Town. If remedial action has commenced within two (2) weeks of
receiving such written notice, there shall be no fine.
O.
CONTRACTOR LIABILITY
Any contractor involved in any activity regulated by the provisions of this Ordinance may
be held liable for violating this Ordinance if the necessary permits for such activity have
not been obtained by himself or his employer.
May 12, 2026
Section: 6 | 51
SECTION 7:
APPEALS
SECTION USER'S GUIDE: This section contains specific provisions regarding
variance and administrative appeals to the Board of Appeals and appeals to Supe
rior Court.
A.
POWERS AND DUTIES OF THE BOARD OF APPEALS
The Board of Appeals shall have the following powers under this Ordinance:
1.
Administrative Appeals - To hear and decide administrative appeals, on an ap
pellate basis, where it is alleged by an aggrieved party that there is an error in
any order, requirement, decision, or determination made by, or failure to act by,
the Planning Board in the administration of this Ordinance; and to hear and de
cide administrative appeals on a de novo basis where it is alleged by an ag
grieved party that there is an error in any order, requirement, decision or deter
mination made by, or failure to act by, the Code Enforcement Officer in his or
her review of and action on a permit application under this Ordinance. Any or
der, requirement, decision or determination made, or failure to act, in the en
forcement of this ordinance is not appealable to the Board of Appeals.
2.
Variance Appeals - To authorize variances upon appeal, within the limitations
set forth in this Ordinance.
B.
VARIANCE APPEALS
Variances may be granted only under the following conditions:
1.
Variances may be granted from the dimensional requirements of this Ordi
nance.
2.
Variances shall not be granted for establishment of any uses otherwise prohib
ited by this Ordinance.
3.
The Board of Appeals shall not grant a variance unless it finds that the strict ap
plication of the terms of this Ordinance would result in undue hardship. The
term "undue hardship" shall mean:
a.
That the land in question cannot yield a reasonable return unless a vari
ance is granted;
b.
That the need for a variance is due to the unique circumstances of the
property and not to the general conditions in the neighborhood;
c.
That the granting of a variance will not alter the essential character of the
locality; and
May 12, 2026
Section: 7 | 53
d.
That the hardship is not the result of action taken by the applicant or a
prior owner.
4.
Notwithstanding §7.B.3.above, the Board of Appeals may grant a variance to
an owner of a residential dwelling for the purpose of making that dwelling ac
cessible to a person with a disability who resides in or regularly uses the
dwelling. The Board of Appeals shall restrict any variance granted under this
subsection solely to the installation of equipment or the construction of struc
tures necessary for access to or egress from the dwelling by the person with
the disability. The Board of Appeals may impose conditions on the variance, in
cluding limiting the variance to the duration of the disability or to the time that
the person with the disability lives in the dwelling. The term "structures neces
sary for access to or egress from the dwelling" shall include railing, wall or roof
systems necessary for the safety or effectiveness of the structure.
5.
The Board of Appeals shall limit any variances granted as strictly as possible in
order to ensure conformance with the purposes and provisions of this Ordi
nance to the greatest extent possible, and in doing so may impose such condi
tions to a variance as it deems necessary. The party receiving the variance
shall comply with any conditions imposed.
C.
ADMINISTRATIVE APPEALS
When the Board of Appeals reviews a decision of the Code Enforcement Officer the
Board of Appeals shall hold a de novo hearing. Any order, requirement, decision or deter
mination made, or failure to act, in the enforcement of this ordinance is not appealable to
the Board of Appeals. At this time the Board may receive and consider new evidence
and testimony, be it oral or written. When acting in a de novo capacity the Board of Ap
peals shall hear and decide the matter afresh, undertaking its own independent analysis
of evidence and the law, and reaching its own decision.
When the Board of Appeals hears a decision of the Planning Board, it shall hold an appel
late hearing, and may reverse the decision of the Planning Board only upon finding that
the decision was contrary to specific provisions of the Ordinance or State law or contrary
to the facts presented to the Planning Board. The Board of Appeals may only review the
record of the proceedings before the Planning Board. The Board Appeals shall not re
ceive or consider any evidence which was not presented to the Planning Board, but the
Board of Appeals may receive and consider written or oral arguments. If the Board of Ap
peals determines that the record of the Planning Board proceedings are inadequate, the
Board of Appeals may remand the matter to the Planning Board for additional fact finding.
D.
APPEAL PROCEDURE
1.
Making an Appeal
54 | Unified Development Review Ordinance
a.
An administrative or variance appeal may be taken to the Board of Ap
peals by an aggrieved party from any decision of the Code Enforcement
Officer or the Planning Board, except for enforcement-related matters as
described in §6.K and §6.L. above. Such an appeal shall be taken within
thirty (30) days of the date of the official, written decision appealed from,
and not otherwise, except that the Board, upon a showing of good cause,
may waive the thirty (30) day requirement.
b.
Applications for appeals shall be made by filing with the Board of Appeals
a written notice of appeal which includes:
i.
A concise written statement indicating what relief is requested and
why the appeal or variance should be granted.
ii.
A sketch drawn to scale showing lot lines, location of existing build
ings and structures and other physical features of the lot pertinent to
the relief sought.
c.
Upon receiving an application for an administrative appeal or a variance,
the Code Enforcement Officer or Planning Board, as appropriate, shall
transmit to the Board of Appeals all of the papers constituting the record of
the decision appealed from.
d.
The Board of Appeals shall hold a public hearing on an administrative ap
peal or a request for a variance within thirty (30) days of its receipt of a
complete written application, unless this time period is extended by the
parties. Hearings shall be conducted in accordance with §4.G
2.
Decision by Board of Appeals
a.
A majority of the full voting membership of the Board shall constitute a
quorum for a meeting.
b.
A majority of the membership of the Board present and voting shall be re
quired for the purpose of deciding an appeal.
c.
The person filing the appeal shall have the burden of proof.
d.
The Board shall decide all administrative appeals and variance appeals
within thirty (30) days after the close of the hearing, and shall issue a writ
ten decision on all appeals.
e.
The Board of Appeals shall state the reasons and basis for its decision, in
cluding a statement of the facts found and conclusions reached by the
Board.
May 12, 2026
Section: 7 | 55
E.
APPEAL TO SUPERIOR COURT
Except as provided by 30-A M.R.S.A. §2691(3)(F), any aggrieved party who participated
as a party during the proceedings before the Board of Appeals may take an appeal to Su
perior Court in accordance with State laws within forty-five (45) days from the date of any
decision of the Board of Appeals
56 | Unified Development Review Ordinance
SECTION 8:
ADMINISTRATIVE PROCEDURES
SECTION USER'S GUIDE: This section contains provisions related to the proce
dure required to have applications placed on the Planning Board's agenda.
A.
PURPOSE
The purpose of this Section is to establish an orderly, equitable and expeditious proce
dure for reviewing applications for developments requiring Planning Board approval under
this Ordinance.
B.
AGENDA
In order to avoid unnecessary delays in processing applications, the Planning Board pre
pares an agenda for each regularly scheduled meeting.
1.
To be considered for placement on the agenda, notification of such must be
communicated by the applicant to the Chairperson, Vice-Chairperson or Secre
tary a minimum of two (2) weeks prior to a Planning Board meeting.
2.
However, if the Planning Board's agenda is already full for the next meeting,
the Secretary shall place the application on the agenda for the next available
meeting.
May 12, 2026
Section: 8 | 57
SECTION 9:
PRE-APPLICATION CONFERENCE (OPTIONAL)
SECTION USER'S GUIDE: This section contains specific information related to the
procedures to be followed during a pre-application conference, the required sub
missions, the setting of the contour intervals required on subsequent plans, the
scheduling of required on-site inspections, and establishes that rights are not
vested by the pre-application review: Both Subdivision and site review.
A.
PROCEDURE
The procedures to be followed for a pre-application conference are as follows:
1.
Applicant submission of sketch plan.
2.
Question and answer period. Planning Board makes specific suggestions to be
incorporated by the applicant into subsequent submissions.
3.
Scheduling of on-site inspection.
B.
SUBMISSION
The pre-application submission shall show, in simple sketch form, the proposed layout of
roads, lots, structures and other features in relation to existing conditions. The Sketch
Plan, which may be a freehand penciled sketch, should be supplemented with general in
formation to describe or outline the existing conditions of the site and the proposed subdi
vision or development. It is recommended that the sketch plan be superimposed on or
accompanied by a copy of the Assessor's Map(s) on which the land is located. The
Sketch Plan shall be accompanied by a copy of a portion of the U.S.G.S. topographic
map of the area showing the outline of the proposed subdivision or development.
C.
CONTOUR INTERVAL AND ON-SITE INSPECTION
Within thirty days, the Planning Board may hold an on-site inspection of the property and
shall determine and inform the applicant in writing of the required contour interval on sub
sequent plans.
D.
RIGHTS NOT VESTED
The submittal or review of the pre-application sketch plan shall not be considered the initi
ation of the review process for the purposes of bringing the plan under the protection of
Title 1, M.R.S.A., §302.
May 12, 2026
Section: 9 | 59
SECTION 10: APPLICATION PROCEDURE AND SUBMISSION RE
QUIREMENTS
SECTION USER'S GUIDE: This section outlines the procedures and submissions
required for the review and approval of Applications submitted to the Planning
Board.
A.
GENERAL
The Planning Board may require, where it deems it necessary for the protection of public
health, safety, and welfare, that a Minor Subdivision (less than 10 lots and/or dwelling
units) comply with all or any of the submission requirements for a Major Subdivision (10
or more lots and/or dwelling units).
B.
PROCEDURE
1.
Pre-application conference: The applicant may request a pre-application con
ference. The Planning Board may request a pre-application conference.
2.
Application: The applicant shall submit an application for approval two weeks
prior to the scheduled meeting of the Planning Board.
3.
Documenting the date of submission: All documents submitted to the Planning
Board shall include the date of submission.
4.
Receipt: When the application is received, a dated receipt shall be provided to
the applicant.
5.
On-Site Visits: The Planning Board may schedule on-site visits at their discre
tion. The Planning Board shall give public notice of on-site visits.
6.
Fees: All applications shall be accompanied by an application fee as estab
lished by the Select Board payable to the Town of Newry. Such fee shall not be
refundable. The Planning Board, at its discretion, may require the applicant to
pay an additional fee to aid the Planning Board in its review of the applicant's
submissions. Said additional fee shall be either 50% of the application fee or
$10,000, whichever is greater and shall be held in a non-interest bearing es
crow account ("The Account"). If the balance of The Account is drawn down by
75%, the Board shall require 50% of the original additional fee to be paid by the
applicant. Any unused portion of escrow account shall be returned to the appli
cant.
7.
Representation: The Applicant, or his duly authorized representative, shall at
tend all meetings of the Planning Board to discuss the application.
May 12, 2026
Section: 10 | 61
8.
Abutter notification: The Applicant, when preparing an application shall notify
by mail and provide the board with certified mail receipts all abutting property
owners within 1,000 feet of the project site. For the purpose of this section
when an abutter is a condominium, the President of the Condominium Associa
tion also shall be notified.
9.
Notification 30 days from application: Within thirty (30) days of receiving an ap
plication and fee, the Applicant will be notified in writing that either that the ap
plication is complete or, if it is incomplete, the specific material needed to com
plete it.
10.
When application is determined Complete: Upon determination by the Plan
ning Board that a complete application has been submitted for review, the Plan
ning Board shall issue a dated receipt to the Applicant and determine whether
to hold a public hearing on the application.
11.
Public hearings: Public hearings are required for Major Subdivisions. For
other applications, the Planning Board may require a public hearing at its dis
cretion. Public hearings shall be held within thirty (30) days from the date of the
vote that an application has been determined to be complete. The Planning
Board shall give public notice of such hearing.
12.
Approval/Denial: Criteria:
a.
Applicant shall meet the performance guarantee requirements contained
in this Ordinance.
b.
Applicant shall prove receipt of all applicable State, Federal and other re
quired permits.
c.
Within thirty (30) days of a public hearing, or within sixty (60) days of re
ceipt of a complete application, if no hearing is held, or within another time
limit as may be otherwise mutually agreed to, in writing, by the Planning
Board and the Applicant, the Planning Board shall approve, approve with
conditions, or deny the Final Plan.
d.
Planning Board shall ensure all Conditions of Approval are documented
on the Final Plan.
13.
Findings of Fact and Conclusions:
The Planning Board, within thirty (30) days of voting to approve, approve with
conditions, or deny, shall make written findings of fact, and conclusions relative
to:
a.
for subdivisions, the standards contained in Title 30-A M.R.S.A. §4404
62 | Unified Development Review Ordinance
b.
for all applications, the provisions of this Ordinance.
C.
SUBMISSIONS
1.
Plan(s)
a.
Initial Submission and Interim Submissions
i.
Eight (8) copies shall be submitted.
ii.
One (1) electronic copy shall be submitted.
iii.
Plans shall be drawn to a scale of one hundred (100) feet to the inch.
Plans containing more than one hundred (100) acres may be drawn
at a scale of two hundred (200) feet to the inch provided all neces
sary detail can easily be read.
iv.
Plans shall be no larger than 24 by 36 inches in size, and shall have
a margin of two (2) inches outside of the border along the remaining
sides.
v.
Plans may be submitted at a reduced legible sized scale, if the appli
cant also provides three (3) full scale sets of drawings.
b.
Final Submission
i.
Two (2) reproducible, minimum weight 20 pound white paper origi
nals, of each sheet of the Final Plan required, one to be recorded at
the Registry of Deeds, and the other to be filed at the Town Office.
ii.
One (1) paper copy of each sheet required of the Final Plan, to be
forwarded to the Code Enforcement Officer.
iii.
The Plan(s) shall be provided in a digital format as specified by the
Planning Board.
iv.
Space shall be provided for endorsement by the Planning Board, see
Appendix 1. Exhibit C for the format.
v.
Shall include a listing of all the plans and documents which comprise
the Final Plan.
2.
The application shall include the following information. An Application Form is
available at the Town Office and online.
May 12, 2026
Section: 10 | 63
a.
Eight (8) copies shall be submitted.
b.
Proposed name(s) of roads within the project approved by the E-911 Ad
dressing Officer.
c.
Information about the Applicant
i.
Name, address and telephone number of Applicant.
ii.
Name address and telephone number of property owner (if other
than applicant).
iii.
If Applicant is a corporation, state whether the corporation is licensed
to do business in Maine, and attach a copy of Secretary of State's
registration.
iv.
Name, address and telephone number of the applicant's authorized
representative.
v.
If applicable, letter(s) from all appropriate parties authorizing the rep
resentative must be submitted with the application.
vi.
Address to which all correspondence from the Planning Board
should be sent.
vii.
A statement describing the interest the applicant has in the parcel to
be developed (option, land purchase contract, record ownership,
etc.)
viii.
A statement describing the interest the applicant has in any property
abutting the parcel to be developed
d.
Information about the Parcel of land
i.
Location of property: Address
ii.
Location of property: Book and page (from Registry of Deeds).
iii.
Location of property: Map and lot (from Town Office).
iv.
Zoning/Land Management District(s).
v.
A statement describing whether the parcel covers the entire contigu
ous holdings of the applicant.
vi.
Total acreage of parcel to be developed. Any encumbrances on the
acreage to be developed such as right-of-ways, easements and land
not suitable for building (§18.E) needs to be listed.
64 | Unified Development Review Ordinance
vii.
For Subdivisions, the number of lots or dwelling units
viii.
For Site Plan review and multi-unit dwelling subdivisions, the total
Impervious Surface and the calculated Impervious Surface Ratio
(ISR).
ix.
A statement indicating if the parcel or structure is part of a prior ap
proved subdivision, or any other division of land within the past five
years.
x.
A copy of the deed or deeds from which the survey was based.
xi.
A copy of all covenants, deed restrictions, easements, rights-of-way,
or other encumbrances currently affecting the property, including
book and page of abutter deed(s).
xii.
Proposed deed restrictions or covenants.
xiii.
Names and addresses of property owners and Condominium Associ
ations within one thousand (1000) feet of the property boundaries in
volved, including owners of the property on the opposite side of the
road. The owners of the property shall be considered to be those
against whom taxes are assessed. In the case of condominium own
ership, the names and addresses of the President(s) of condominium
association(s).
xiv.
A written statement indicating if the parcel to be developed has
changed ownership within the past five years, if timber has been har
vested within the past five years and if such harvesting resulted in a
violation of the applicable State of Maine laws.
xv.
A copy of the approved Driveway or Entrance permit issued by the
Maine Department of Transportation if a driveway or entrance will en
ter onto Route 2 or 26 or the Sunday River Road (from its intersec
tion with Route 2 to the Ski Way Road) and letter showing town ap
proval for subdivision entrance road onto the town road.
xvi. RESERVED
xvii. A description of the type of sewage disposal to be used.
(1)
When sewage disposal is to be accomplished by subsur
face wastewater disposal systems, test pit analyses, pre
pared by a Licensed Site Evaluator, shall be provided. A
map showing the location of all test pits dug on the site
May 12, 2026
Section: 10 | 65
shall be submitted. There shall be a minimum of one (1)
test pit per lot.
(2)
When sewage disposal is to be accomplished by connec
tion to a multi-user system, provide a written statement
that plans have been submitted to the Department of Hu
man Services, Division of Health Engineers or the Depart
ment of Environmental Protection. A multi-user water sys
tem may be required, see C.2.d.xix.(3) of this section.
xviii. A class A high intensity soil map covering the parcel to be developed
and a written soils report, both prepared by a Maine Registered Soils
Scientist. The Board may waive or modify this requirement for lots
greater than two (2) acres in size or for Minor Subdivisions.
xix. Description of the type of water supply system(s) to be used.
(1)
Any multi-user supply systems shall be mapped and de
scribed.
(2)
When water is to be supplied by private wells, evidence of
adequate ground water supply and quality shall be submit
ted by a well driller or a hydro-geologist familiar with the
area.
(3)
On lots under one (1) acre in size when a multi-user
sewage system is used, a multi-user water system shall be
required unless it can be proven that wells will be accom
modated within state subsurface waste water rules by us
ing a nitrate impact model or other methods acceptable to
the town.
xx.
Description of method of fire protection proposed.
xxi. Description of method of solid waste disposal.
xxii. If the applicant proposes to dedicate recreation or common land to
the public, provide a written description of proposal.
xxiii. Provide a list and proof of application of required State and Federal
permits.
xxiv. Traffic Data (the Board may waive this requirement for Minor Subdi
visions). Traffic data shall include the following:
66 | Unified Development Review Ordinance
(1)
The estimated peak-hour traffic to be generated by the
proposal.
(2)
Traffic accident data covering the most recent three-year
period for which such data is available.
(3)
The capacity of surrounding roads and any improvements
which may be necessary on such roads to accommodate
anticipated traffic generation.
(4)
When a Maine Department of Transportation Traffic Move
ment Permit is required, existing traffic counts and vol
umes on surrounding roads must be submitted.
xxv. RESERVED
]
e.
Information on the Development Plan
i.
Name, address and number of licensed professional engineer, Pro
fessional Land Surveyor, or planner who prepared the plan.
ii.
Proposed name of Development or identifying title; and the name of
the Town.
iii.
Date, magnetic north point, graphic map scale.
iv.
A field survey of the boundary lines of the parcel, giving complete de
scriptive data bearings and distances, made and certified with the
embossed seal of the Professional Land Surveyor. The corners of
the tract shall be located on the ground and marked by monuments.
The plan shall indicate the type of monument set or found at each lot
corner.
v.
For Subdivisions:
(1)
Lot or unit numbers.
(2)
Lot lines with dimensions and areas.
vi.
Suggested locations of subsurface sewage disposal systems, and
wells.
vii.
Contour lines at 5' intervals or other intervals as specified by the
Board, showing elevation in relation to Mean Sea Level (NGVD).
May 12, 2026
Section: 10 | 67
viii.
If any portion of the parcel is in a flood-prone area, the boundaries of
any flood hazard areas and the 100-year flood elevation.
ix.
The title and boundary lines of any zoning or Land Management Dis
trict boundaries.
x.
Setback lines of all applicable building setbacks.
xi.
Location, ground floor area and height of buildings and other struc
tures within 500 feet of the site.
xii.
Location and dimensions of on-site pedestrian and vehicular access
ways, parking areas, loading and unloading facilities, design of
ingress and egress of vehicles to and from the site on to public roads
and curb and sidewalk lines.
xiii.
Landscape plan showing location, type and approximate size of
plantings and location and dimensions of all fencing and screening.
xiv.
Location and size of existing sewers and water mains, and culverts
and drains.
xv.
The location of freshwater wetlands.
xvi. The location of all Farmland within the proposed project. Farmland
is defined as a parcel consisting of five (5) or more acres of land that
is:
(1)
Classified as prime farmland, unique farmland or farmland
of statewide or local importance by the Natural Resources
Conservation Service within the United States Department
of Agriculture; or
(2)
Used for the production of agricultural products as defined
in Title 7, §152, subsection 2. ("Agricultural products"
means those plants and animals and their products that
are useful to humans and includes, but is not limited to,
forages and sod crops, grains and feed crops, dairy and
dairy products, poultry and poultry products, bees and
bees' products, livestock and livestock products and fruits,
berries, vegetables, flowers, seeds, grasses and other
similar products, or any other plant, animal or plant or ani
mal products that supply humans with food, feed, fiber or
fur. "Agricultural products" does not include trees grown
and harvested for forest products.)
68 | Unified Development Review Ordinance
xvii. The location of all rivers, streams and brooks within the parcel or
within 250 feet of the parcel to be developed.
xviii. Areas within the parcel or within 250 feet of the parcel which have
been identified as significant wildlife habitat by the Maine Depart
ment of Inland Fisheries and Wildlife. If any portion of the proposed
project is located within an area designated as a unique natural area
by the Maine Natural Areas Program, the plan shall indicate appro
priate measures for the preservation of the values which qualify the
site for such designation.
xix. The location of all parcels of land proposed to be dedicated to public
use and the conditions of such dedication.
xx.
The location of any open space to be preserved and a description of
proposed ownership, improvement and management.
xxi. The location of open drainage courses, wetlands, significant wildlife
habitat, known or potential archaeological resource, historic buildings
and sites, significant scenic areas, mapped sand and gravel aquifers,
rare and endangered, other important natural features with a descrip
tion of how such features will be maintained or impacts upon them
minimized.
xxii. The location, names, and present right of way widths of existing
roads, highways, easements, building lines, parks and other open
spaces on or adjacent to the parcel to be developed.
xxiii. Location and names of proposed streets
xxiv. The location of all existing and proposed overhead and underground
utilities.
xxv. For Site Plan review, the location, dimensions, design and exterior
materials of all proposed buildings and structures.
xxvi. The location and dimensions of existing and proposed signs.
xxvii.The size, location and direction and intensity of illumination and
method of installation of all major outdoor lighting apparatus.
xxviii.
The type, size and location of all incineration devices.
xxix. The type, size and location of all machinery likely to generate appre
ciable noise at the lot lines. Technical Information required pertaining
to Noise (sound level analysis): Technical information shall be sub
May 12, 2026
Section: 10 | 69
mitted describing the Applicant's plan and intent to make adequate
provision for the control of noise. The applicant's plan shall contain
information such as the following, when appropriate:
(1)
Maps and descriptions of the land uses, local zoning and
comprehensive plans for the area potentially affected by
sounds from the facility.
(2)
Preconstruction Ambient sound levels
(3)
A description of major sound sources, including tonal
sound sources and sources of short duration repetitive
sounds, associated with the construction, operation and
maintenance of the proposed facility, including their loca
tions within the proposed facility.
(4)
A description of the daytime and nighttime hourly sound
levels and, for short duration repetitive sounds, the maxi
mum sound levels expected to be produced by these
sound sources at Protected Locations.
(5)
A description of proposed major sound control measures,
including their locations and expected performance.
(6)
A comparison of the expected sound levels from the pro
posed facility with the sound level limits of this regulation.
xxx. Suitable space to record on the approved plan, the date and condi
tions of approval if any.
xxxi. Plans to be recorded at the County Registry of Deeds must be rolled,
not folded, and shall have a dimension in inches of a minimum 11x17
and a maximum of 24x36 and be printed on white paper with a mini
mum weight of 20 pounds. They must include a registrar's block no
smaller than 3x3 inches for the register's purposes, and include a ti
tle block with the name of the plan, the record owner's name and ad
dress, the location by street and town and the date of the plan. They
must be embossed, sealed or both with the seal of an architect, pro
fessional engineer, or professional land surveyor, and contain the
signature and address of the plan preparer.
f.
Accompanying Documents
i.
Eight (8) copies shall be submitted.
70 | Unified Development Review Ordinance
ii.
Copies of letters to the Newry Fire Chief, Newry Road Commissioner
and Oxford County Sheriff's Department notifying them of the pro
posed development project and requesting their comments.
iii.
A list of construction items including but not limited to the Required
Improvements, with cost estimates, that will be completed by the ap
plicant.
iv.
Written evidence from financial institutions that the applicant has fi
nancial commitments or resources to cover these costs.
v.
A separate list of construction and maintenance items, with both cap
ital and annual operating cost estimates, that must be financed by
the Town, or construction and maintenance items, with both capital
and annual operating cost estimates, that must be financed by the
Town, or quasi-municipal districts. These lists shall include but not
be limited to:
(1)
Schools, including bussing.
(2)
Recreation facilities.
(3)
Road maintenance and snow removal.
(4)
Storm water drainage.
(5)
Police and fire protection.
(6)
Solid waste disposal.
(7)
The applicant shall provide the Planning Board with an as
sessment of the financial impacts of the proposed devel
opment on the above public facilities and services.
vi.
A storm water management plan, prepared by a registered profes
sional engineer in accordance with the most recent edition of Storm
Water Management for Maine: BMPS Technical Design Manual,
published by the Maine Department of Environmental Protection.
[Note: The applicant need only to submit one copy of storm water
calculations]
vii.
An erosion and sedimentation control plan prepared in accordance
with the Maine Erosion and Sedimentation Control Handbook for
Construction: Best Management Practices.
May 12, 2026
Section: 10 | 71
viii.
If the proposed Development is in the direct watershed of Howards
Pond, a phosphorus control plan shall be submitted.
ix.
Road and roadway plan and profile drawings drawn to a scale 1" =
100' horizontal and 1" = 1' vertical, prepared by Licensed Profes
sional Engineer. The Planning Board may allow for a variation of
scale based on readability.
x.
Typical cross section views of all proposed roads.
xi.
Other information not indicated above, as specified by the Planning
Board on the application.
g.
Submission Waivers - See §13.A.
h.
Easements - The Planning board may require easements for sewage,
drainage, or other utilities.
i.
Additional information for Commercial Wind Energy Facilities
i.
Location map showing the boundaries of the proposed facility site
and all contiguous property under total or partial control of the Appli
cant or Participating Landowner(s) and any Scenic Resource or His
toric Site within one (1) mile of the proposed development.
ii.
Description of the proposed Wind Energy Facility that includes the
number and aggregate generating capacity of all Wind Turbines, the
Turbine Height and manufacturer's specifications for each Wind Tur
bine (including but not limited to the make, model, maximum gener
ating capacity, sound emission levels and types of overspeed con
trols) and a description of Associated Facilities.
iii.
Site plan showing the proposed location of each Wind Turbine, its
flicker sector, Associated Facilities and any of the following features
located within 1,000 feet of any Wind Turbine: parcel boundaries, re
quired setbacks, topographic contour lines (maximum 20-foot inter
val), roads, rights-of-way, overhead utility lines, buildings (identified
by use), land cover, wetlands, streams, water bodies and areas pro
posed to be re-graded or cleared of vegetation.
iv.
Written evidence that the provider of electrical service to the property
has been notified of the intent to connect an electric generator to the
electricity grid.
v.
Description of emergency and normal shutdown procedures.
72 | Unified Development Review Ordinance
vi.
Photographs of existing conditions at the site.
vii.
Site line, photographic and, if applicable any screening information.
(1)
Sight Line Representations of each Wind Turbine from the
nearest Occupied Building, Planned Residence, or other
approved but not yet developed facility and from at least
one other representative location within 1,000 feet of the
Wind Turbine, such as a Scenic Resource or another Oc
cupied Building. Each Site Line Representation shall be
drawn at a scale sufficiently large to make it legible. If
screening is proposed, the proposed screening device,
such as trees, shrubs or fencing, shall be depicted on the
drawing along with the sight line as altered by the screen
ing.
(2)
A current four-inch by six-inch color photograph of the pro
posed site of the Wind Turbine(s) taken from viewpoints
corresponding to each of the Site Line Representations.
(3)
One copy of each of the photographs described in b),
above, onto which is superimposed an accurately-scaled
and sited presentation of the Wind Turbine(s).
viii.
Certificates of design compliance obtained by the equipment manu
facturers from Underwriters Laboratories, Det Norske Veritas, or
other similar certifying organizations.
ix.
Decommissioning plan.
x.
Written summary of operation and maintenance procedures for the
Wind Energy Facility and a maintenance plan for access roads.
xi.
Visual impact assessment.
xii.
Sound level analysis, prepared by a qualified engineer.
xiii.
Shadow Flicker analysis based on WindPro or other modeling soft
ware approved by the Department of Environmental Protection. The
Flicker Sector will be shown on maps.
xiv.
Foundation and anchoring system drawings that are stamped by a
Maine-licensed professional engineer.
xv.
A Public Utility Grid Impact Statement documenting all anticipated
changes to the public utility grid within the Town due to the Wind En
May 12, 2026
Section: 10 | 73
ergy Facility. The Statement shall be signed and approved by the
Maine Public Utilities Commission and shall include proof of leases
or rights of way for transmission lines, and an analysis of the residual
capacity in the grid that will be available to other local generating
projects after the construction of the Wind Energy Facility.
xvi. Other relevant studies, reports, certifications and approvals as may
be reasonably requested by the Planning Board to ensure compli
ance with this Ordinance.
j.
Additional Information for Wireless Telecommunications Facilities
i.
A copy of the FCC license for the Wireless Telecommunications Fa
cility or a signed statement from the owner or operator of the Wire
less Telecommunications Facility attesting that the Wireless Telecom
munications Facility complies with current FCC regulations.
ii.
For a proposed expansion of a facility, a signed statement that com
mits the owner of the facility, and its successors or assigns, to:
(1)
Respond in a timely, comprehensive manner to a request
for information from a potential colocation applicant, in ex
change for a reasonable fee not in excess of the actual
cost of preparing a response;
(2)
Negotiate in good faith for shared use by third parties;
(3)
Allow shared use if colocation applicant agrees in writing
to pay reasonable charges for colocation;
(4)
Require no more than a reasonable charge for shared use,
based on community rates and generally accepted ac
counting principles. This charge may include but is not lim
ited to a pro rata share of the cost of site selection, plan
ning project administration, land costs, site design, con
struction and maintenance, financing, return on equity, de
preciation, and all of the costs of adopting the tower or
equipment to accommodate a shared user without causing
electromagnetic interference.
iii.
Applicants for a Wireless Telecommunications Facility permit must
be a telecommunications provider or must provide a copy of its
lease/contract with an existing telecommunications provider. Alterna
tively, applicants may provide letters of intent from carriers to place
antennas on the tower once all necessary permits and authorizations
74 | Unified Development Review Ordinance
have been obtained, including approval by the Planning Board. A
permit issued under this ordinance shall not be granted for a wireless
communications facility to be built on speculation.
iv.
A USGS 7.5 minute topographic map showing the location of all
structures and Wireless Telecommunication Facilities above 150 feet
in height above ground level, except antennas located on roof tops,
within a five (5) mile radius of the proposed Wireless Telecommuni
cations Facility. This requirement may be met by submitting current
information (within thirty days of the date the application is filed) from
the FCC Tower Registration Database.
v.
Certification by a registered electrical or electronics engineer that the
proposed facility complies with all FCC standards for radio emis
sions.
vi.
A scenic assessment, consisting of the following:
(1)
Elevation drawings of the proposed Wireless Telecommu
nications Facility, and any other proposed structures,
showing Height above ground level;
(2)
A landscaping plan indicating the proposed placement of
the Wireless Telecommunications Facility on the site; loca
tion of existing structures, trees, and other significant site
features; the type and location of plants proposed to
screen the Wireless Telecommunications Facility; the
method of fencing, the color of the structure, and the pro
posed lighting method.
(3)
Photo or video simulations of the proposed Wireless
Telecommunications Facility taken from perspectives de
termined by the Planning Board, or their designee. Each
photo and video must be labeled with the Line of Sight, el
evation, and with the date taken imprinted on the photo
graph. The photos and videos must show the color of the
Wireless Telecommunications Facility and method of
screening.
vii.
A narrative discussing:
(1)
the extent to which the proposed Wireless Telecommuni
cations Facility would be visible from or within a Desig
nated Scenic Resource,
May 12, 2026
Section: 10 | 75
(2)
the tree line elevation of vegetation within 100 feet of the
Wireless Telecommunications Facility, and
(3)
the distance to the proposed Wireless Telecommunica
tions Facility from the Designated Scenic Resource's
noted Viewpoints.
viii.
A written description of how the proposed Facility fits into the service
provider's telecommunications network. This submission requirement
does not require disclosure of confidential business information.
ix.
Evidence demonstrating that no existing building, site, or structure
can accommodate the applicant's proposed Wireless Telecommuni
cations Facility, the evidence for which may consist of any one or
more of the following:
(1)
Evidence that no existing Facilities are located within the
Targeted Market Coverage Area as required to meet the
applicant's engineering requirements,
(2)
Evidence that existing Wireless Telecommunications Facil
ities do not have sufficient Height or cannot be increased
in Height at a reasonable cost to meet the applicant's engi
neering requirements,
(3)
Evidence that existing Wireless Telecommunications Facil
ities do not have sufficient structural strength to support
applicant's proposed antenna and related equipment.
Specifically:
(a)
Planned, necessary equipment would exceed the
structural capacity of the existing Wireless Telecommuni
cations Facility, considering the existing and planned use
of those Facilities, and these existing Facilities cannot be
reinforced to accommodate the new equipment.
(b)
The applicant's proposed antenna or equipment
would cause electromagnetic interference with the an
tenna on the existing towers or structures, or the antenna
or equipment on the existing Wireless Telecommunications
Facility would cause interference with the applicant's pro
posed antenna.
76 | Unified Development Review Ordinance
(c)
Existing or approved Wireless Telecommunications
Facilities do not have space on which planned equipment
can be placed so it can function effectively.
(4)
For Wireless Telecommunications Facilities existing prior
to the effective date of this Ordinance, the fees, costs, or
contractual provisions required by the owner in order to
share or adapt an existing Wireless Telecommunication
Facility are unreasonable. Costs exceeding the pro rata
share of a new Wireless Telecommunication Facility devel
opment are presumed to be unreasonable. This evidence
shall also be satisfactory for a tower built after the passage
of this ordinance;
(5)
Evidence that the applicant has made diligent good faith
efforts to negotiate Colocation on an existing Wireless
Telecommunication Facility, building, or structure, and has
been denied access.
x.
A form of surety approved by the Select Board to pay for the costs of
removing the Wireless Telecommunication Facility if it is abandoned.
xi.
Evidence that a notice of the application has been published in a lo
cal newspaper of general circulation in the community.
k.
Additional Information for Solar Energy Systems
i.
A description of the owner of the Solar Energy System, the operator
if different, and detail of qualifications and track record to run the fa
cility.
ii.
If the operator will be leasing the land, a copy of the agreement (mi
nus financial compensation) clearly outlining the relationship inclu
sive of the rights and responsibilities of the operator, landowner and
any other responsible party with regard to the Solar Energy System
and the life of the agreement.
iii.
A description of how and to whom the energy produced will be sold.
iv.
A copy of the agreement and schematic details of the connection ar
rangement with the transmission system (most likely Central Maine
Power), clearly indicating which party is responsible for various re
quirements and how they will be operated and maintained.
May 12, 2026
Section: 10 | 77
v.
A description of the panels to be installed, including make and
model, and associated major system components.
vi.
A construction plan and timeline, identifying known contractors, site
control and anticipated on-line date.
vii.
An emergency management plan for all anticipated hazards.
viii.
A stormwater management plan, certified by a licensed Maine engi
neer, that demonstrates stormwater from the Solar Energy System
will infiltrate into the ground beneath the Solar Energy System at a
rate equal to that of the infiltration rate prior to the placement of the
system.
ix.
A background noise measurement for the site location as per §18.Z,
Noise.
x.
Proof of financial capacity to construct and operate the proposed So
lar Energy System.
xi.
A decommissioning plan, including:
(1)
A description of the trigger for implementing the decom
missioning plan. There is a rebuttable presumption that
decommissioning is required if 10% or less permitted ca
pacity of electricity is generated for a continuous period of
twelve (12) months. The Applicant may rebut the presump
tion by providing evidence, such as a force majeure event
that interrupts the generation of electricity, that although
the project has not generated electricity for a continuous
period of twelve (12) months, the project has not been
abandoned and should not be decommissioned.
(2)
A description of the work required to physically remove all
Solar Energy System and solar related components, in
cluding associated foundations, buildings, cabling, electri
cal components, and any other associated facilities to the
extent they are not otherwise in or proposed to be placed
into productive use. All earth disturbed during decommis
sioning must be graded and re-seeded, unless the
landowner of the affected land requests otherwise in writ
ing and subject to Planning Board approval.
(3)
An estimate of the total cost of decommissioning value of
the equipment and itemization of the estimated major ex
78 | Unified Development Review Ordinance
penses, including the projected costs of measures taken to
minimize or prevent adverse effects on the environment
during implementation of the decommissioning plan. The
itemization of major costs may include, but is not limited
to, the cost of the following activities: panel removal, panel
foundation removal and permanent stabilization, building
removal and permanent stabilization, transmission corridor
removal and permanent stabilization and road infrastruc
ture removal and permanent stabilization.
(4)
Demonstration in the form of a performance bond, surety
bond, letter of credit, or other form of financial assurance
as may be acceptable to the Select Board that upon the
end of the useful life of the Solar Energy System the Appli
cant will have the necessary financial assurance in place
for 150% of the estimated total cost of decommissioning,
subject to a review of such cost by the Code Enforcement
Officer. The financial assurance shall include a provision
granting the Town the ability to access the funds and prop
erty and perform the decommissioning if the facility is
abandoned or the Applicant or subsequent responsible
party fails to meet their obligations after reasonable notice,
to be defined in the agreement and approved by the Plan
ning Board. For a Medium Scale Solar Energy System, the
Applicant may propose securing the necessary financial
assurance in phases, as long as the total required financial
assurance is in place a minimum of five (5) years prior to
the expected end of the useful life of the Solar Energy
System.
D.
FINAL APPROVAL AND FILING
1.
No plan shall be approved by the Planning Board if the applicant has outstand
ing violations of this Ordinance.
2.
The Planning Board shall confirm all Conditions of Approval are documented
on Final Plans submitted for signature.
3.
Once the board has determined the facts of the application and has determined
that all standards in Title 30-A, M.R.S.A., §4404, and this Ordinance have been
met, and upon voting to approve or amend the Application, the Planning Board
shall sign the Final Plan.
May 12, 2026
Section: 10 | 79
a.
The Applicant shall provide and the Planning Board shall sign:
i.
Two (2) reproducible, minimum weight 20 pound white paper origi
nals, of each sheet of the Final Plan required, one to be recorded at
the Registry of Deeds, and the other to be filed at the Town Office.
ii.
One (1) paper copy of each sheet required of the Final Plan to be
forwarded to the Code Enforcement Officer.
iii.
The Plan(s) shall be provided in digital format as specified by the
Planning Board.
iv.
Space shall be provided for endorsement by the Planning Board in a
format specified by the Planning Board.
b.
Plans to be recorded with the County Registrar shall meet the following:
i.
Be rolled, not folded, and shall have a dimension in inches of a mini
mum 11x17 and a maximum of 24x36 and be printed on white paper
with a minimum weight of 20 pounds.
ii.
Include a registrar's block no smaller than 3x3 inches for the regis
ter's purposes, and include a title block with the name of the plan,
the record owner's name and address, the location by street and
town and the date of the plan. They must be embossed, sealed or
both with the seal of an architect, professional engineer, or profes
sional land surveyor, and contain the signature and address of the
plan preparer.
c.
Any Final Plan not recorded in the Registry of Deeds within ninety (90)
days of the date upon which the plan is approved and signed by the Plan
ning Board shall be considered unapproved and shall require resubmis
sion, review and approval.
4.
Within thirty (30) days from the date of granting final approval, the applicant
shall provide the Code Enforcement Officer with one complete set of all plans,
specifications and documents as approved by the Planning Board.
5.
No changes, erasures, modification, or revisions shall be made on the Final
Plan presented for Planning Board signatures. The Planning Board shall make
sure findings of the plan meet the standards of Title 30-A, M.R.S.A., §4404, and
this Ordinance. In the event that a Plan is recorded without complying with this
requirement, it shall be considered null and void, and the Planning Board shall
have a notice placed in the Registry of Deeds to that effect.
80 | Unified Development Review Ordinance
6.
The approval by the Planning Board of a proposed plan shall not be deemed to
constitute or be evidence of any acceptance by the Town of any easement, or
other open space shown on such plan. When a park, playground, or other
recreation area shall have been shown on the plan to be dedicated to the Town,
approval of the Plan shall not constitute an acceptance by the municipality of
such areas. The Planning Board shall require the plan to contain appropriate
notes to this effect. The Planning Board may also require the filing of a written
agreement between the applicant and the Select Board covering future deed
and title, dedication, and provision for the cost of grading, development, equip
ment, and maintenance of any such dedicated area.
May 12, 2026
Section: 10 | 81
SECTION 11: GROWTH MANAGEMENT DISTRICTS AND
NONCONFORMANCE
SECTION USER'S GUIDE: This section establishes Growth Management Districts,
dimensional requirements, Growth Management District uses and provisions re
garding non-conforming structures, uses and lots.
A.
GROWTH MANAGEMENT DISTRICTS ESTABLISHED
For the purposes of this Ordinance, the Town of Newry is hereby divided into the following
Growth Management Districts:
1.
Resort Development District (RDD);
2.
General Development District (GDD);
3.
Rural District (RD); and
4.
Protection District (PD).
B.
STANDARDS ESTABLISHING DISTRICTS AND DISTRICT DESCRIPTIONS
1.
Resort Development District
The purpose of the Resort Development District is to provide expansion areas
for the Sunday River Ski Resort and associated development. Such
development may include additional skiing terrain, lodging facilities in the form
of hotels, town houses, single-family homes, employee housing, facilities to
move the resort to a four-season destination and alpine commercial/village
areas. Such development is largely dependent on terrain suitable for alpine ski
trails and other recreation facilities including golf courses.
2.
General Development District
The purpose of the General Development District (GDD) is to provide
designated areas where orderly growth and development will be allowed during
the next ten years as required by the Maine Comprehensive Planning and Land
Use Regulation Act (Title 30-A, §4326). A wide range of development types are
appropriate in this area including single-family residential, multi-family
residential, public, governmental, commercial and recreational.
3.
Rural District
The purpose of the Rural District is to maintain large blocks of forest land and
open space and minimize public expenditures to provide municipal services to
these remote areas. Appropriate uses for this area are low density residential,
forestry, recreation and other land uses requiring rural and remote locations.
May 12, 2026
Section: 11 | 83
4.
Protection District
The purpose of the Protection District (PD) is to provide protection for
significant and vulnerable natural resources. These include areas above 2,700
feet in elevation from mean sea level and those areas within the Town of Newry
used as municipal water supply.
C.
OFFICIAL GROWTH MANAGEMENT DISTRICT MAP
Growth Management Districts established by this Ordinance are bounded and defined as
provided in B. above and shown on the official "Growth Management District Map of
Newry, Maine" which together with its notations and amendments, from time to time, is
hereby made a part of this Ordinance.
The official copy of the map shall be that map which bears the certification that it is true
and correct, signed by the Chairman of the Planning Board and attested by the Town
Clerk, and on file in the office of the Town Clerk.
D.
INTERPRETATION OF DISTRICT BOUNDARIES
Where uncertainty exists as to boundary lines of Districts as shown on the official "Growth
Management District Map of Newry, Maine," the following rules of interpretation shall ap
ply:
1.
Boundaries indicated as approximately following the center lines of road, high
ways, public utilities or right-of-ways shall be construed as following such cen
ter lines;
2.
Boundaries indicated as approximately following platted lot lines shall be con
strued as following such lot lines;
3.
Boundaries indicated as being the extension of center lines of roads shall be
construed to be the extension of such center lines as of the date of this ordi
nance;
4.
Boundaries indicated as approximately following the center lines of streams,
rivers or other continuously flowing water courses shall be construed as follow
ing the channel center line of such watercourses as of the date of this ordi
nance.
5.
Boundaries indicated as being parallel or extension of features listed above
shall be so construed. Distances not specifically indicated on the official map
shall be determined by the scale of the map;
6.
Where physical or cultural features existing on the ground are at variance with
those shown on the official map, or in other circumstances where uncertainty
84 | Unified Development Review Ordinance
exists with respect to the location of a boundary, the Planning Board shall inter
pret the district boundaries; and
7.
Boundaries for 100 year floodplain areas are based upon the most current in
formation available from the State or Federal agencies responsible and are
subject to change as such information changes and/or the applicant shows
proof through the submittal of materials prepared by a Professional Land Sur
veyor or which shows proof that the property in question lies at least one (1)
foot above the one hundred (100) year flood level. The elevation of filled or
made land shall not be considered.
E.
DIVISION OF LOTS BY DISTRICT BOUNDARIES
In the event that a District boundary line divides a lot or parcel of land of the same owner
ship of record, at the time such line is established by adoption or subsequent amendment
of this Ordinance, the Planning Board, after written findings of fact, that such extensions
will not create unreasonable adverse impacts on the existing uses of the adjacent proper
ties, may:
1.
When that portion of the lot which is located in the more restrictive District is
greater than 10 (ten) acres, extend the regulations applicable to the less re
stricted portion into no more than twenty percent (20%) of the more restrictive
portion.
2.
When the portion of the lot which is located in the more restrict District is less
than 10 (ten) acres, extend the regulations applicable to the less restrictive
portion into no more than fifty percent (50%) of the more restrictive portion.
3.
When that portion of the lot which is located in the more restrictive District is
equal to that which is located in the less restrict District, extend the regulations
applicable to the less restrictive portion to all of the more restrictive portion.
4.
Except that, no such extensions shall be granted by the Planning Board into
any Resource Protection District.
May 12, 2026
Section: 11 | 85
F.
DIMENSIONAL REQUIREMENTS
All lots, structures and uses shall meet or exceed the following dimensional requirements:
District
Minimum Lot
Size Density
Minimum
Road
Frontage
Minimum
Structure
Front
Setback1
Minimum
Structure
Side
Setback
Minimum
Structure
Rear
Setback
Maximum
Impervious
Surface
Ratio
(percent)
Maximum
Structure
Height2
RDD
20,000 sq. ft.
per lot or unit,
sewered
43,560 sq. ft.
per lot or unit,
nonsewered
Multi-unit
housing per
unit:
10,000 sq. ft.
sewered
20,000 sq. ft.
nonsewered
75 ft.
sewered
100 ft.
nonsewered
10 ft.
10 ft.
10 ft.
70
40 ft.
GDD
20,000 sq. ft.
per lot or unit,
sewered
43,560 sq. ft.
per lot or unit,
nonsewered
Multi-unit
housing / unit:
20,000 sq. ft.
sewered
43,560 sq. ft.
nonsewered
100 ft.
25ft.
10 ft.
10 ft.
50
40 ft.
RD
43,560 sq. ft.
per lot or unit
150 ft.
50 ft.
25 ft.
25 ft.
25
40 ft.
PD
43,560 sq. ft.
per lot or unit
150 ft.
50 ft.
25 ft.
25 ft.
25
40 ft.
NOTES:
1.
Measured from the edge of the road right-of-way.
86 | Unified Development Review Ordinance
2.
The vertical distance between the mean finish grade at the downhill side of the structure measured from
the finished top floor level intended for human habitation.
3.
Each lot must be able to completely contain within its boundaries an area as would be defined by a circle
with a minimum diameter equal to the required minimum road frontage as required in the district.
4.
Notwithstanding the space and bulk standards contained above, any allowable use located in and ap
proved as a planned unit development in the Resort Development District shall instead comply with the
terms of that approval.
G.
RESERVED
H.
DISTRICT USES
All land use activities, as indicated in the Table of District Land Uses, shall conform with
all applicable land use standards. The district designation for a particular site shall be de
termined from the Growth Management District Map.
Key to Table:
Yes
Allowed (no permit required under this Ordinance but must comply with
all applicable performance standards.
No
Not allowed
PB
Required approval by the Planning Board
PBSR
Requires a Site Plan Review Approval.
PBSD
Requires subdivision approval.
Abbreviations:
RDD
Resort Development District
GDD
General Development District
RD
Rural District
PD
Protection District
TABLE OF DISTRICT LAND USES
LAND USES
DISTRICTS
RDD
GDD
RD
PD
1.
Land Management Activities
yes
yes
yes
yes
2.
Timber harvesting
yes
yes
yes
yes
3.
Commercial Procurement, storage,
transportation of potable water
PBSR
PBSR
PBSR
PBSR
May 12, 2026
Section: 11 | 87
LAND USES
DISTRICTS
RDD
GDD
RD
PD
4.
Land Based Recreation Activities,
Equipment & maintenance
PBSR
PBSR
PBSR
PBSR
5.
Borrow Pit/Mineral extraction, in
cluding sand and gravel extraction
CEO/
PB
PBSR
PBSR
no
6.
Single family home
yes
yes
yes
no
7.
Two family home
yes
yes
yes
no
8.
Multi-Unit housing
PBSD
PBSD
PBSD
no
9.
Mobile home park
no
PBSD
no
no
10.
Home Occupations1
yes
yes
yes
no
11.
Agriculture/Forestry Sales & Service
PBSR
PBSR
PBSR
no
12.
Government offices/facilities
PBSR
PBSR
no
no
13.
Public/private schools
PBSR
PBSR
no
no
14.
Museum/Library
PBSR
PBSR
PBSR
no
15.
Public Utility Facility
PBSR
PBSR
PBSR
no
16.
Automobile Graveyard/Recycling/
Junkyard
no
no
PBSR
no
17.
Hotel/Motel
PBSR
PBSR
no
no
18.
Resort Based Uses
PBSR
PBSR
no
no
19.
Bed & Breakfast
PBSR
PBSR
PBSR
no
20.
Restaurant
PBSR
PBSR
no
no
21.
Retail Business
PBSR
PBSR
no
no
22.
Service Business
PBSR
PBSR
no
no
23.
Wholesale Business
PBSR
PBSR
no
no
24.
Commercial Recreation
PBSR
PBSR
PBSR
no
25.
Outdoor Recreation Based Sales &
Service
PBSR
PBSR
PBSR
no
26.
Campground
no
no
PBSR
no
88 | Unified Development Review Ordinance
LAND USES
DISTRICTS
RDD
GDD
RD
PD
27.
Industrial
PBSR
PBSR
no
no
28.
Demolition/Waste Disposal
no
no
PBSR
no
29.
Sawmill
no
PBSR
PBSR
no
30.
Commercial Communication Tower
PBSR
PBSR
PBSR
no
31.
Commercial Wind Energy Facility
PBSR
no
no
No
32.
Solar Energy Systems
See §27.C.2
33.
Mineral Exploration or Extraction
no
PB
PB
no
34.
Recreational Lodging Facilities2
PB
PB
PB
no
35.
Parking Facility
PB
PB
no
no
36.
Uses similar to uses requiring a PB
permit/approval
PB
PB
PB
PB
Notes to the Table of District Land Uses:
1. Home Occupation that do not meet the criteria contained in §1.C.5 require a
permit from the Planning Board in accordance with §24
2. Except campgrounds.
I.
NONCONFORMING STRUCTURES, USES AND LOTS
1.
Burden of Proof
The burden of establishing that any non-conforming structure, use or lot is a
legal existing non-conforming use as defined in this Ordinance shall, in all
instances, be upon the owner of such non-conforming structure, use or lot and
not upon the Town of Newry.
2.
Conversion to Conformance Encouraged
Owners of all existing non-conforming structures and uses shall be encouraged
to convert such existing non-conforming structures and uses to conformance
wherever possible and shall be required to convert to conforming status as
required by the Ordinance.
3.
Continuance
May 12, 2026
Section: 11 | 89
The use of any building, structure or land, which is made non conforming by
reason of the enactment of this Ordinance, or which shall be made non-
conforming by reason of a subsequent amendment, may be continued, subject
to the following provisions:
a.
Existing Nonconforming Uses of Land. Continuance of non-conforming
uses of land shall be subject to the following provisions:
i.
No such existing non-conforming use shall be enlarged or increased,
nor extended to occupy a greater area of land than that occupied at
the effective date of this Ordinance, or any amendment thereto;
ii.
If any such existing non-conforming use of land discontinued for any
reason for a period of more than twelve (12) consecutive months,
any subsequent use of land shall conform to the requirements speci
fied by this Ordinance for the District in which such land is located;
iii.
An existing non-conforming use may be moved within the boundaries
of the lot provided that the Planning Board or its designee finds that
the change in location on the lot is more appropriate as regards:
(1)
Location and character;
(2)
Fencing and screening;
(3)
Landscaping, topography and natural features;
(4)
Traffic and access;
(5)
Signs and lighting; and/or
(6)
Potential nuisance
b.
Existing Nonconforming Structures
Continuance of existing non-conforming structures shall be subject to the follow
ing provisions:
i.
No such structure shall be enlarged or altered in any way that in
creases its non-conforming;
ii.
Should any structure, exclusive of the foundation, be destroyed or
damaged by any means, or removed, said structure may be rebuilt
on the existing foundation to the dimensions of the structure which
was destroyed provided rebuilding is begun within one year; and
90 | Unified Development Review Ordinance
iii.
An existing non-conforming structure may be moved within a lot in a
manner which would decrease its non-conformity in terms of setback
requirements, provided that the Planning Board makes findings that
the change in location is more appropriate as regards to:
(1)
Location and character;
(2)
Fencing and screening;
(3)
Landscaping, topography and natural features;
(4)
Traffic and access;
(5)
Signs and lighting; and/or
(6)
Potential nuisance.
c.
Existing Nonconforming Uses of Structures
Continuance of a legally existing non-conforming use of a structure shall be sub
ject to the following provisions:
i.
No existing structure devoted to a non-conforming use shall be en
larged or extended;
ii.
Any existing non-conforming use may be extended throughout any
parts of a building which were manifestly arranged or designed for
such use at the time of adoption or amendment of this Ordinance,
but no such uses shall be extended to occupy any land outside such
building;
iii.
Any existing non-conforming use of a structure or premises may be
changed to another non-conforming use provided that the Planning
Board shall find that the proposed use is more appropriate to the Dis
trict than the existing non-conforming use. The determination of
more appropriate use shall be made according to:
(1)
The proposed use is less noxious than the current noncon
forming use;
(2)
The proposed use will not create a traffic hazard nor in
crease an existing traffic hazard;
(3)
The amount of parking required to meet the minimum re
quirements for the proposed use exists on the site or will
be otherwise provided in accordance with this Ordinance;
May 12, 2026
Section: 11 | 91
(4)
That the amount of noise, odors, vibrations, smoke, dust
and air discharges of the proposed use shall be equal to or
less than the present use;
(5)
That the rate of surface water run-off from the site will not
be increased;
(6)
That the hours of operation of the proposed use will be
compatible with the existing, surrounding land uses; and
(7)
That the proposed use will not increase the adverse im
pact on surrounding properties.
iv.
If a non-conforming use of a structure or premises is superseded by
a permitted use, the non-conforming use shall not thereafter be re
sumed;
v.
If any such non-conforming use of a structure is discontinued for any
reason for a period of more than twelve (12) months, any subse
quent use of such structure shall conform to the regulation specified
by this Ordinance for the District in which such structure is located;
and
vi.
A structure containing an existing non-conforming use may be
moved, within the lot, in a manner which would be a more appropri
ate location, provided that the Planning Board finds that the change
in location is more appropriate as regards to:
(1)
Location and character;
(2)
Fencing and screening;
(3)
Landscaping, topography and natural features;
(4)
Traffic and access;
(5)
Signs and lighting; and
(6)
Potential nuisance.
d.
Construction Begun Prior to Ordinance.
This Ordinance shall not require any change in the plans, construction, size or
designated use for any building, structure or part thereof for which a completed
application for a local permit has been made or a permit has been issued and upon
which construction has been lawfully commenced prior to the adoption or amend
ment of the Ordinance. Such construction shall start within sixty (60) days after
the issuance of such permit.
92 | Unified Development Review Ordinance
4.
Nonconforming Lots of Record
A single parcel of land, the legal description of which or the dimensions of
which are recorded on a document or map on file with the Registry of Deeds
which at the effective date of adoption or subsequent amendments of this
Ordinance, does not meet the lot area or width requirements or both, of the
District in which it is located, may be built upon as an existing non-conforming
lot of record even though such lot may be contiguous with any other lot in the
same ownership, provided that all other provisions of this Ordinance shall be
met.
5.
Transfer of Ownership
Ownership of land and structures which remain lawful but become non-
conforming by the adoption or amendment of the Ordinance may be transferred
and the new owner may continue the non-conforming uses subject to the
provisions of this Ordinance.
May 12, 2026
Section: 11 | 93
SECTION 12: PERFORMANCE GUARANTEES
SECTION USER'S GUIDE: This section contains specific provisions relating to re
quired performance guarantees and how they will be administered.
A.
TYPES OF GUARANTEES
With submittal of the application for Final Plan approval, the applicant shall provide one of
the following performance guarantees for an amount adequate to cover the total construc
tion costs of all Required Improvements. The amount shall take into account the time-
span of the construction schedule and the inflation rate for construction costs. The Plan
ning Board shall not waive the requirement for a performance guarantee on an applica
tion for a subdivision (major or minor). The actual guarantee is not required to be tended
until five days prior to start of construction.
1.
Either a certified check payable to the Town or a savings account or certificate
of deposit both naming the Town as owner, or the establishment of an escrow
account, as provided for in Section C, below;
2.
A performance bond payable to the Town issued by a surety company, ap
proved by the Select Board, as provided for in Section D, below;
3.
An irrevocable letter of credit from a financial institution establishing funding for
the construction of the Required Improvements, from which the Town may draw
if construction is inadequate, approved by the Select Board, as provided for in
Section E, below; or
4.
An offer of conditional approval limiting the number of units or lots sold until all
Required Improvements have been constructed, as provided for in Section F,
below.
B.
CONTENTS OF GUARANTEE
The performance guarantee shall contain a construction schedule, cost estimates for
each major phase of construction taking into account inflation, provisions for inspections
of each phase of construction, provisions for the release of part or all of the performance
guarantee to the developer, and a date after which the developer will be in default allow
ing the Town access to the funds to finish construction, as provided for in Section I, below.
C.
ESCROW ACCOUNT
A cash contribution to the establishment of an escrow account shall be made by either a
certified check made out to the Town, the direct deposit into a savings account, or the pur
chase of a certificate of deposit. For any account opened by the developer, the Town
shall be named as owner or co-owner, and the consent of the Town shall be required for a
May 12, 2026
Section: 12 | 95
withdrawal. Any interest earned on the escrow account shall be returned to the devel
oper.
D.
PERFORMANCE BOND
A performance bond shall detail the conditions of the bond, the method for release of the
bond or portions of the bond to the developer, and the procedures for collection by the
Town. The bond documents shall specifically reference the Required Improvements for
which approval is sought.
E.
LETTER OF CREDIT
An irrevocable letter of credit from a bank or other lending institution shall indicate that funds
have been set aside for the construction of the development and may not be used for any other
project or loan.
F.
CONDITIONAL AGREEMENT
The Planning Board, at its discretion may provide for the developer to enter into a binding
agreement with the Town in lieu of the other financial performance guarantees. Such an
agreement shall provide for approval of the Final Plan on the condition that no lot or unit
may be conveyed until:
1.
It is certified by the Inspecting Official that all of the Required Improvements
have been installed in accordance with the Final Plan; or
2.
A performance guarantee, acceptable to the Town is submitted in an amount
necessary to cover the completion of the Required Improvements at an amount
adjusted for inflation and prorated for the portions of the Required Improve
ments already installed. Notice of agreement and any conditions shall be on
the Final Plan which is recorded at the Registry of Deeds. Release from the
agreement shall follow the procedures for release of the performance guaran
tees for Required Improvements contained in Subsection I.
G.
PHASING OF DEVELOPMENT
The Planning Board may approve plans in separate and distinct phases. Prior to con
struction of subsequent phases, the developer shall present again adequate performance
guarantee for Required Improvements.
H.
EXTENSION
The Planning Board may recommend a maximum extension of twelve (12) months to the
guaranteed performance period when the applicant can demonstrate, to the satisfaction
of the Planning Board good cause for such extension. Such recommendation shall be re
ferred to the Select Board for official action.
96 | Unified Development Review Ordinance
I.
RELEASE OF GUARANTEE
Prior to the release of any part of the performance guarantee, the Planning Board shall
determine to its satisfaction, in part upon the report of the Inspecting Official and whatever
other agencies and departments may be involved, that the proposed Required Improve
ments meet or exceed the design and construction requirements for that portion of the
Required Improvements for which the release is requested.
J.
DEFAULT
If, upon inspection, the Inspecting Official finds that any of the Required Improvements
have not been constructed as approved by the Planning Board in accordance with the
plans and specifications filed as part of the application, except for modifications approved
in accordance with Section 6.A.4, he shall so report in writing to the Code Enforcement
Officer, the Select Board, the Planning Board, and the applicant or developer. The Select
Board shall take any steps necessary to preserve the Town's rights.
K.
IMPROVEMENTS GUARANTEED
Performance guarantees shall be tendered for all Required Improvements.
May 12, 2026
Section: 12 | 97
SECTION 13: WAIVERS
SECTION USER'S GUIDE: This section authorizes the Planning Board, under spe
cial circumstances, to waive portions of the submission requirements, perfor
mance standards and improvements required by this Ordinance and provides that
such waiver be granted only with conditions.
A.
WAIVER OF SUBMISSION REQUIREMENTS
Where the Planning Board makes written findings of fact that there are special circum
stances of a particular site proposed to be subdivided or developed, it may waive portions
of the submission requirements, provided that the applicant has demonstrated that the
standards of this Ordinance have been or will be met, the public health, safety and wel
fare are protected and provided the waivers do not have the effect of nullifying the intent
and purpose of the Comprehensive Plan or any Ordinance.
B.
WAIVER OF PERFORMANCE STANDARDS
Where the Planning Board makes written findings of fact that there are special circum
stances of a particular site proposed to be subdivided or developed, it may waive portions
of the performance standards, unless otherwise indicated in this Ordinance, to permit a
more practical and economical development, provided the public health, safety and wel
fare are protected, and provided the waivers do not have the effect of nullifying the intent
and purpose of the Comprehensive Plan or any Ordinance.
C.
WAIVERS OF REQUIRED IMPROVEMENTS
Where the Planning Board makes written findings of fact that due to special circum
stances of a particular site proposed to be subdivided or developed, the provision of cer
tain Required Improvements is not requisite to provide for the public health, safety or wel
fare, or are inappropriate because of inadequate or lacking connecting facilities adjacent
to or in proximity to the proposed subdivision or development, it may waive the require
ment for such improvements, subject to appropriate conditions.
D.
WAIVERS CONDITIONALLY GRANTED
In granting waivers to any of the provisions of this Ordinance in accordance with subsec
tions A, B, and C, above, the Planning Board shall require such conditions as will assure
the purposes and objectives of this Ordinance are met.
May 12, 2026
Section: 13 | 99
SECTION 14: PROVISION FOR CLUSTER DEVELOPMENT
SECTION USER'S GUIDE: This section allows innovative approaches to housing
and environmental design by authorizing the Planning Board to reduce certain re
quirements of this Ordinance for applicants proposing clustered development.
A.
PURPOSE
It is the policy of the Town of Newry to encourage the development of cluster subdivisions
in order to preserve a sense of space, provide for open meadow areas woodland tracts,
recreational land uses, preserve other resources identified in the Town of Newry Compre
hensive Plan, and blend new development with the traditional open and wooded land
scapes of Newry.
These provisions are intended to implement that policy by providing incentives that afford
flexibility in lot sizes/density, lot layout and design and road frontage requirements to the
landowner. It also allows the Planning Board to waive or reduce certain otherwise appli
cable standards and provisions of this Ordinance and other Town of Newry Ordinances if
landowners commit to the permanent preservation of important open space resources.
These incentives are designed to encourage greater flexibility and more innovative ap
proaches to development and environmental design which will promote the most appro
priate use of land, preservation of permanent open space that include meadow areas,
woodlands, important natural features, wildlife habitat, water resources, ecological sys
tems and scenic areas for the benefit of present and future residents.
A cluster subdivision achieves the purposes of this Section by reducing the lot size,
frontage and setback requirements. It locates structures and accompanying uses in
those areas where they have the smallest impact on identified meadow areas, wood
lands, environmental, wildlife and other open space resources. These resources are then
permanently preserved by the use of covenants and restrictions or conservation ease
ments.
B.
APPLICATION PROCEDURE
1.
Any applicant for a cluster subdivision is encouraged, but not required, to have
a pre-application conference with the Planning Board.
2.
The submissions for a subdivision with open space shall include all plans and
materials required for a conventional subdivision under this Ordinance.
C.
GENERAL REQUIREMENTS
In Planning Board review and approval of a cluster subdivision, the following require
ments shall apply and shall supersede any inconsistent or more restrictive provisions of
May 12, 2026
Section: 14 | 101
this Ordinance and other Town of Newry Ordinances. Dimensional reductions shall not
be considered as a variance as provided for in Title 30-A MRSA Section 4353. 4-C.
1.
Allowable Density
The number of lots or dwelling units shall be based in the following manner:
Determine the Buildable Land of the parcel by taking the total area of the parcel
and subtracting in order the following:
a.
area in proposed rights-of-way and other easements;
b.
area of two or more contiguous acres with sustained slopes of 20% and
greater;
c.
area of the parcel covered by surface waters.
Then divide the Buildable Land by the minimum lot size required for the District.
A minimum of 50% of the buildable area must be designated as open space.
2.
Layout and Siting Standards
In planning the location and siting of residential structures in a cluster,
subdivision priority should be given to the preservation of the open space for its
natural resource value. Structures and other disturbed areas shall be located
and sited on the least valuable natural resource portion of a parcel, taking into
account the contours of the land and the steepness of slopes.
The building lots on a parcel shall be laid out and the residential structures
shall be sited according to the following principles. The Planning Board in its
discretion shall resolve conflicts between these principles as applied to a
particular site.
a.
In such manner that the boundaries between residential lots and open
spaces are well-buffered by vegetation, topography, roads or other barri
ers in order to minimize potential conflict between residential and open
space uses.
b.
Lots and/or structures will be oriented with respect to scenic vistas, natu
ral landscape features, topography and natural drainage areas, in accor
dance with an overall plan for site development.
3.
Space Standards
a.
In shoreland areas all dimensional requirements shall not be reduced be
low the minimum required in the Shoreland Zoning Ordinance.
102 | Unified Development Review Ordinance
b.
The required minimum land area per dwelling unit for the building enve
lope may be reduced to 20,000 square feet based on soil suitability for
subsurface waste water disposal. The building envelope shall not include
100-year floodplains, areas of two or more acres of sustained slopes
greater than 20 percent, or wetlands. The Planning Board may further re
duce this standard when the development will be served by a sewage
treatment system., so long as the reductions don't exceed 50% of the al
lowed lot width and 50% of the allowed lot area.
c.
The acreage shall be contiguous, unless the Planning Board finds that
noncontiguous acres are part of a common, overall scheme of develop
ment.
d.
If the lot area is reduced, the total open space in the development shall
equal or exceed the sum of the areas by which the building lots are re
duced below the minimum lot area normally required in the district.
e.
Minimum road frontage requirements may be waived or modified by the
Planning Board provided that no individual lot or dwelling unit shall have
direct vehicular access onto a public road existing at the time of develop
ment.
f.
The minimum distance between detached abutters' structures shall be
twenty (20) feet. This shall be noted on the subdivision plan.
4.
Open Space Requirements
In Planning Board review and approval of a cluster subdivision, the following
requirements shall apply and shall supersede any inconsistent or more
restrictive provision of this Ordinance.
a.
Open Space Uses. On all parcels, open space uses shall be appropriate
to the site. Open space should include natural features located on the
parcel(s) such as, but not limited to, open meadows, woodland and
wildlife habitat. Open space shall be preserved and maintained subject to
the following, as applicable:
i.
On parcels that contain land that are suited to meadow uses, open
space shall be preserved for such use, other compatible open space
uses such as wildlife habitat, non-intensive recreation, or resource
conservation.
ii.
On parcels that contain land that are suited to woodland uses, open
space shall be preserved for forestry, other compatible open space
May 12, 2026
Section: 14 | 103
uses such as wildlife habitat, non-intensive recreation (active or pas
sive), or resource conservation.
b.
When the principal purpose of preserving portions of the open space is
the protection of natural resources such as wetlands, steep slopes, wildlife
habitats, and stream corridors, open space uses in those portions may be
limited to those which are no more intensive than passive recreation.
c.
Notations on Plan. Open space, common lands, roads or facilities must
be clearly labeled on the final plan as to its use or uses with respect to the
portions of the open space that such use or uses apply, ownership, man
agement, method of preservation, and the rights, if any, of the owners in
the subdivision to such land or portions thereof. The plan shall clearly
show that the open space land is permanently reserved for open space
purposes, and shall contain a notation indicating the book and page of
any conservation easements or deed restrictions required to be recorded
to implement such reservations.
d.
Ownership of Open Space Land. Open space land may be held in private
ownership; or owned in common by a Homeowners' Association (HOA);
transferred to a nonprofit organization such as a conservation trust, or as
sociation, acceptable to the Planning Board; or held in such other form of
ownership as the Planning Board finds adequate to achieve the purposes
set forth in subparagraph 4.a and 4.b above and under the other require
ments of this Section. The Planning Board shall, in its review, require as a
condition of approval provisions for the ongoing maintenance and associ
ated costs for such maintenance of the open space.
5.
Homeowners' Associations or Agreements
Where any portion of a subdivision, including but not limited to common land or
elements, open space, private roads, or stormwater management systems,
basins, ditches, and appurtenances, is proposed or required to be held in
common by owners of lots, or owned in common by a Homeowners'
Association (HOA) or similar entities, covenants for mandatory membership in
the association setting forth the owners' rights, interest, privileges,
responsibilities for maintenance, and obligations in the association and the
common land, road or open space shall be approved by the Planning Board
and included in the deed for each lot. The Planning Board shall not waive this
requirement.
104 | Unified Development Review Ordinance
SECTION 15: PROVISION FOR PLANNED UNIT DEVELOPMENT
SECTION USER'S GUIDE: This section provides for developments that contain a
mixture of land uses including, but not limited to, residential, commercial, recre
ational and open space that are preplanned and developed under unified manage
ment. It allows innovative approaches to large scaled mixed use developments
and authorizes the Planning Board to reduce certain requirements of this Ordi
nance.
A.
PURPOSE
The purpose of this section is to allow for large-scale, well planned developments that:
1.
are in accordance with the Town's Comprehensive Plan;
2.
are reasonably self-sufficient in the provision of necessary services, such as
sewerage, water supply, off-street parking, recreational amenities, and long-
term management of common facilities;
3.
integrate a variety of residential, commercial, and/or recreational uses;
4.
preserve open space;
5.
incorporate a pattern of development that is in harmony with the natural fea
tures of the land; and
6.
provide for efficient use of the land, minimizing the required networks of roads
and utilities.
B.
PROCEDURE
1.
Proposed planned unit developments shall be reviewed as a Major Subdivision,
unless the applicant proposal also includes Commercial Use. If Commercial
Use are proposed, the planned unit development shall be reviewed as both a
Major Subdivision and a Site Plan. The tract or parcel of land proposed for
planned unit development must be in single ownership or the subject of an ap
plication filed jointly by the owners of all the property included. The applicant
must demonstrate right, title, or interest in the land that is the subject of the ap
plication. The planned unit development review procedure shall consist of the
following steps:
a.
a preapplication conference;
b.
preliminary development plan;
c.
final development plan and subdivision and site plan review approval as
applicable.
May 12, 2026
Section: 15 | 105
2.
The preapplication conference shall serve the purpose of informally acquainting
the Planning Board with the overall scope and intentions of the proposed
planned unit development and of acquainting the developer with the require
ments of this Section. At the preapplication conference, the developer shall
submit to the Planning Board a sketch plan of the proposed planned unit devel
opment, which shows the bounds of the total development and the mix of land
uses proposed and their general locations. No action shall be required on the
sketch plan, which is presented for informational purposes only.
3.
The preliminary development plan shall constitute a formal submission of a
subdivision application and site plan review application to the Planning Board.
In addition to the submission requirements for subdivision and site plan review
applications the following items are required to be submitted as part of the pre
liminary development plan:
a.
a legal description of the total planned unit development boundaries and
of any divisions of the land, existing or proposed, within these boundaries.
b.
a statement of present and proposed ownership of all lands within the pro
posed planned unit development.
c.
Proposed development schedule that indicates when the project and
stages thereof will begin and be completed.
d.
a statement sufficient to satisfy the Planning Board that the project can be
realistically financed and completed.
e.
the subdivision and site plan shall include clear notations as to which facil
ities are proposed to be in public, private, or common ownership.
f.
The Planning Board shall, as part of its review of the preliminary develop
ment plan, conduct a public hearing on the planned unit development.
4.
The final development plan shall constitute a formal submission of a final subdi
vision application and site plan review application to the Planning Board, but
only of such part of the planned unit development that has received approval of
a preliminary development plan. In addition to the submission requirements for
subdivision and site plan review applications the following items are required to
be submitted as part of the final development plan:
a.
drawings that include all the information required under the preliminary
development plan.
b.
copies of restrictive covenants or deed restrictions relating to the develop
ment.
106 | Unified Development Review Ordinance
c.
evidence of the formation and incorporation by the developer of any asso
ciation that may be proposed to manage and maintain common spaces
and facilities.
5.
For any existing development that meets the definition of a planned unit devel
opment, lawfully existing or in progress as of the effective date of this Ordi
nance may submit an existing conditions plan to the Planning Board. The ex
isting conditions plan shall indicate as built conditions and the management
and maintenance of common spaces and facilities. After receipt of the existing
conditions plan, the Planning Board, upon application by the developer for ex
pansion of or additional development within the planned unit development, may
at its sole discretion waive the requirement of a preapplication conference and
such portions of the required preliminary development plan submissions as it
believes have been satisfied or are unnecessary to make a reasoned decision
on the proposed expansion or addition.
C.
STANDARDS
1.
For the purpose of establishing space and bulk standards applicable to planned
unit developments, notwithstanding district regulations to the contrary, the
space and bulk standards for planned unit developments shall be as follows.
Dimensional reductions shall not be considered as a variance as provided for in
Title 30-A MRSA §4353(4-C).
a.
A planned unit development shall contain at least ten acres of buildable
land area in single ownership.
b.
The acreage shall be contiguous, unless the Planning Board finds that
noncontiguous acres are part of a common, overall scheme of develop
ment. Land contained in planned unit that has provided the Planning
Board with an existing conditions plan may be included within the mini
mum 10-acre requirement.
c.
Allowable uses shall be those listed as permitted in the Growth Manage
ment District in which the Plan Unit Development is located.
d.
The planned unit development shall be served by centralized multi-user
sewerage and water supply facilities.
e.
Lots which may be created for nonresidential uses shall include sufficient
land area to support any proposed structures, the required off-street park
ing for the uses, whether or not the parking actually is located on the lots,
and safe pedestrian circulation.
May 12, 2026
Section: 15 | 107
f.
Net lot area per dwelling unit shall be not less than required in the Growth
Management District in which the Plan Unit Development is located.
g.
No building or structure shall be located closer than 25 feet to the perime
ter boundary line of the planned unit development. The minimum dis
tance between detached abutters' structures shall be twenty (20) feet.
This shall be noted on the development plan.
h.
In shoreland areas all dimensional requirements shall not be reduced be
low the minimum required in the Shoreland Zoning Ordinance.
i.
Maximum Impervious Surface Ratio (ISR) in a planned unit development
shall not exceed 60%.
j.
Other space and bulk dimensions for planned unit developments shall be
as shown and approved by the Planning Board on the final development
plan.
2.
It is encouraged that buildings be oriented with consideration for scenic vistas
as view by others, natural landscape features, topography, and potential solar
access.
3.
All utilities shall be installed underground, unless specifically waived by the
Planning Board.
4.
A system of pedestrian circulation and amenities including sidewalks within and
adjacent to the Planned Unit Development shall be provided. This system will
connect with existing or planned sidewalks.
5.
The Planned Unit Development shall be designed to be transit-orientated and
discourage the use of the private automobile.
108 | Unified Development Review Ordinance
SECTION 16: RESERVED
May 12, 2026
Section: 16 | 109
SECTION 17: DEDICATION AND MAINTENANCE OF COMMON LAND
AND SERVICES
SECTION USER'S GUIDE: This section contains specific provisions regarding the
dedication and maintenance of common land and common services.
A.
DEDICATION
1.
All common land shall be owned jointly or in common by the owners of the
dwelling units by means of a homeowners' association, by an association which
has as its principal purpose the conservation or preservation of land in essen
tially its undeveloped condition as meadow, wood or agricultural land, or by an
acceptable legal entity.
2.
Further subdivision of the common land, except for easements for underground
infrastructure improvements, shall be prohibited.
3.
The common land shall be shown on the Final Plan with appropriate notation
on the plan to indicate that:
a.
It shall not be used for future building lots; and
b.
A part or all of the common land may be dedicated for acceptance by the
municipality or other organization acceptable to the Board.
B.
MAINTENANCE
1.
If any or all of the common open space and services are to be reserved for use
by the residents, the by-laws of the proposed homeowners' association shall
specify maintenance responsibilities and shall be submitted to the Planning
Board prior to Final Plan approval.
2.
Covenants for mandatory membership in the homeowners' association setting
forth the owners' right, interests, and privileges in the association and the com
mon property, shall be reviewed by the Planning Board and shall be included in
the deed for each lot or dwelling.
3.
The homeowners' association shall have the responsibility of maintaining the
common property unless or until dedication is accepted by the Town or other
ownership organization acceptable to the Board.
4.
The association shall levy annual charges against all owners of dwelling units
to defray the expenses connected with the maintenance of common property
and tax assessments.
May 12, 2026
Section: 17 | 111
5.
The developer or subdivider shall maintain control of the common property, and
be responsible for its maintenance until development sufficient to support the
association has taken place.
112 | Unified Development Review Ordinance
SECTION 18: GENERAL PERFORMANCE STANDARDS
SECTION USER'S GUIDE: This section contains general performance standards
with which all development proposals submitted for approval pursuant to this Or
dinance must comply. In reviewing applications submitted pursuant to this Ordi
nance, the Planning Board shall consider the following performance standards.
A.
CONFORMANCE WITH COMPREHENSIVE PLAN
All proposed developments regulated by this Ordinance shall be in conformity with the
Comprehensive Plan and Policy Statements of the Town and with the provisions of all
pertinent local ordinances and regulations, and State and Federal laws and regulations.
B.
MUNICIPAL SERVICES
The proposed development shall not have an unreasonable adverse impact on the mu
nicipal services including municipal road systems, fire department, police department,
solid waste program, schools, recreational programs and facilities, and other municipal
services and facilities. When the Planning Board finds, based on a recommendation of
the Select Board and other departments and the results of any municipal impact analysis,
that includes future tax payments that will support municipal services, that municipal ser
vices do not have the capacity to provide services to the proposed development, the
Planning Board will require one or more of the following.
1.
A voluntary payment to the Town of Newry to mitigate the direct impact to mu
nicipal services that has been identified as the consequence of the proposed
subdivision. Any such payment shall be subject to the following provisions.
a.
The Planning Board, with advice from the Select Board, shall find that the
money offered will mitigate the identified direct impact of the development.
b.
The payment shall be held in a reserve account and may only be ex
pended to fund capital improvements agreed to by the applicant and Plan
ning Board to mitigate the identified direct impacts.
c.
The payment in all cases shall be expended within five years of collection,
unless otherwise agreed upon the Planning Board and applicant.
d.
Any payment not expended shall be refunded to the property owner(s) of
record at the time of the refund with interest as earned by the Town of
Newry for the period the payment was held by the Town.
2.
The applicant will construct or pay to construct his proportional share of the re
quired improvements necessitated by the development.
May 12, 2026
Section: 18 | 113
3.
Require phasing of the subdivision or limiting the number of lots that can be de
veloped at any one time to allow the expansion of municipal services over time.
4.
Deny the development.
C.
PRESERVATION AND ENHANCEMENT OF THE LANDSCAPE
The landscape shall be preserved in its natural state insofar as practicable by minimizing
tree removal, disturbance of soil, and retaining existing vegetation during construction.
After construction is completed, landscaping shall be implemented that will define, soften
or screen the appearance of off-street parking areas, buildings and other structures from
the public right-of-way and abutting properties in order to enhance the physical design of
the proposed development, and to minimize the encroachment of the proposed uses on
neighboring land uses.
D.
RELATION OF PROPOSED BUILDINGS TO ENVIRONMENT
Proposed structures should have a minimal adverse effect on the environmental and aes
thetic qualities of the developed and neighboring areas. Special attention should be paid
to the bulk, location and height of the building(s) and such natural features as slope, soil
type and drainage ways. For Commercial Use structures the Planning Board may con
sider the following criteria.
1.
Architectural style is not restricted. Evaluation of the appearance of a project
shall be based on the quality of its design and relationship to surroundings.
2.
Buildings shall have good scale and be in harmonious conformance with per
manent neighboring development.
3.
Materials shall have good architectural character and shall be selected for har
mony of the building with adjoining buildings.
4.
Materials shall be selected for suitability to the type of buildings and the design
in which they are used. Buildings shall have the same materials, or those that
are architecturally harmonious, used for all building walls and other exterior
building components wholly or partly visible from public roads.
5.
Materials shall be of durable quality.
6.
Building components, such as windows, doors and eaves, shall have good pro
portions and relationships to one another.
7.
Colors shall be harmonious and shall use compatible accents.
8.
Mechanical equipment or other utility hardware on roof, ground or buildings
shall be screened from public view with materials harmonious with the building,
114 | Unified Development Review Ordinance
or they shall be located so visibility from any public road is minimized. System
for wind and solar power and for telecommunications need not meet this stan
dard.
9.
Exterior lighting shall be part of the architectural concept. Fixtures, standards
and all exposed accessories shall be harmonious with building design. All ex
terior lighting shall be shielded or hooded
10.
Refuse and waste removal areas, service yards, storage yards, and exterior
work areas shall be screened from view from public roads, using materials as
stated in criteria for equipment screening.
11.
Monotony of design in single or multiple building projects shall be avoided.
Variation of detail, form and siting shall be used to provide visual interest. In
multiple building projects, viable siting or individual buildings may be used to
prevent a monotonous appearance.
E.
LAND NOT SUITABLE FOR BUILDING
The following areas shall not be built on excluding road and driveway construction.
1.
Land which is situated below the normal high water mark of any water body.
2.
Land which is located within the one hundred (100) year floodplain, other than
roads and driveways which shall be constructed to meet standards contained in
the Shoreland Zoning Ordinance and/or Floodplain Management Ordinance
where applicable, as identified by the Federal Emergency Management
Agency, Flood Insurance Administration, unless the applicant shows proof
through the submittal of materials prepared by a Professional Land Survey that
the property in question lies at least one (1) foot above the one hundred (100)
year flood level. The elevation of filled or made land shall not be considered.
3.
Land which is part of a permanent road right-of-way or permanent road ease
ment.
4.
Land that has been created by filling or draining a pond or wetland that has not
received approval for such filling and draining by the Army Corps of Engineers
and/or the Maine Department of Environmental Protection.
5.
Land that has been identified as significant wildlife habitat by the Maine Depart
ment of Inland Fisheries and Wildlife when a mitigation plan has not been ap
proved by the Maine Department of Inland Fisheries and Wildlife.
May 12, 2026
Section: 18 | 115
F.
TOPSOIL AND VEGETATION REMOVAL
1.
Topsoil shall be considered part of the development and shall not be removed
from the site except for surplus topsoil from roads, parking areas, and building
excavations, unless otherwise indicated on an approved site plan.
2.
Sufficient residual vegetation shall be left intact to prevent soil erosion following
forest practices, landscaping, and cutting of trees to provide access to direct
sunlight. The Planning Board shall require a developer to take measures to
correct and prevent soil erosion in the proposed development.
3.
To prevent soil erosion of shoreline areas (as defined), timber harvesting and
clearing or removal of vegetation for development shall comply with the regula
tions set forth in the Shoreland Zoning Ordinance.
G.
EROSION AND SEDIMENTATION CONTROL
The following measures relating to conservation, erosion and sediment control shall be in
cluded where applicable as part of all projects submitted for review and approval under
this Ordinance.
1.
All excavation shall be undertaken by contractors Certified in Erosion and Sedi
ment Control by the Maine Department of Environmental Protection.
2.
The Code Enforcement Officer shall require the developer and/or owners to
prevent soil erosion and sediment transport on the site and onto adjacent and
downstream properties. Erosion control practices shall conform to the Maine
Erosion and Sediment Control Best Management Practices (BMPs), Manual for
Designers and Engineers.
3.
Erosion of soil and sedimentation of watercourses and water bodies shall be
minimized by employing the following best-management practices:
a.
Stripping of vegetation, soil removal and re-grading or other development
shall be done in such a way as to minimize erosion;
b.
Development shall keep cut-fill operations to a minimum and ensure con
formity with topography so as to create the least erosion potential and ad
equately handle the volume and velocity of surface water run-off;
c.
Whenever feasible, natural vegetation shall be retained, protected and
supplemented;
d.
The disturbed area and the duration of exposure shall be kept to a practi
cal minimum;
116 | Unified Development Review Ordinance
e.
Disturbed soils shall be stabilized as quickly as practicable;
f.
Temporary vegetation or mulching shall be used to protect disturbed areas
during development;
g.
Until the disturbed area is stabilized, sediment in the run-off water shall be
trapped by the use of debris basins, sediment basins, silt traps or other
acceptable methods;
h.
The top of a cut or the bottom of a fill section shall not be closer than ten
(10) feet to an adjoining property, unless otherwise specified by the Code
Enforcement Officer.
i.
During grading operations, methods of dust control shall be employed
wherever practicable.
j.
Whenever sedimentation is caused by stripping vegetation, re-grading or
other development, it shall be the responsibility of the developer causing
such sedimentation to remove it from all adjoining surfaces, drainage sys
tems and watercourses and to repair any damage at his expense as
quickly as possible.
H.
STORMWATER MANAGEMENT
1.
For projects that require a Department of Environmental Protection (DEP) re
view under the Site Location of Development Act (SLODA), a stormwater man
agement plan shall be submitted which complies with the SLODA permit and
the requirements of DEP Chapter 500 Stormwater Regulations.
2.
For projects that do not require a SLODA permit, but require a DEP permit un
der the Stormwater Law, a stormwater management plan shall be submitted
which complies with the requirements of DEP Chapter 500 Stormwater Regula
tions.
3.
For projects that neither require a SLODA permit, nor a DEP permit under the
Stormwater Law, a stormwater management plan shall be submitted which in
corporates adequate provision for the management of the quantity and quality
of all storm water generated within the subdivision, and any drained ground wa
ter through a management system of swales, culverts, underdrains, storm
drains and best management practices equivalent to those in the most recent
edition of Stormwater Management for Maine: BMPS Technical Design Man
ual, published by the Maine Department of Environmental Protectio.
4.
Where necessary to achieve the above standards, there shall be provided
easements or drainage rights-of-way with swales, culverts, catch basins or
May 12, 2026
Section: 18 | 117
other means of channeling surface water within the subdivision and over other
properties.
5.
The storm drainage system will not adversely affect neighboring properties,
downstream water quality, or cause soil erosion. Whenever possible, on-site
absorption of run-off waters shall be utilized to minimize discharges from the
site.
6.
Maintenance of drainage facilities or watercourses originating and completely
on private property is the responsibility of the owner to the point of open dis
charge at the property line or at a communal watercourse within the property.
I.
RESERVED
J.
SITE CONDITIONS
1.
During construction, the site shall be maintained and left each day in a safe
and sanitary manner and any condition which could lead to personal injury or
property damage shall be immediately corrected by the developer upon an or
der by the Code Enforcement Officer or other authorized personnel. The devel
oper shall make provision for disposal of oil and grease from equipment and
the site area should be regularly treated to control dust from construction activ
ity.
2.
Developed areas shall be cleared of all stumps, litter, rubbish, brush, weeds,
dead and dying trees, roots and debris, and excess or scrap building materials
shall be removed or destroyed immediately upon the request of and to the sat
isfaction of the Code Enforcement Officer.
3.
No change shall be made in the elevation or contour of any lot or site other
than as shown on the Final Plan. This includes the removal or addition of earth
to or from another lot or site. Minimal changes in elevations or contours neces
sitated by the field conditions may be made as long as the change does not
substantially or negatively impact the site.
K.
PLUMBING
All plumbing and sewage disposal shall be in conformance with the State of Maine Law
and the State Plumbing Code and Subsurface Waste Water Disposal Rules.
L.
WATER SUPPLY
1.
The Planning Board may allow the use of individual wells or a private multi-user
water supply system.
118 | Unified Development Review Ordinance
2.
When a development is to be served by a multi-user water supply system, the
complete supply system, including any required fire ponds and dry hydrants,
shall be installed at the expense of the developer.
3.
If a multi-user water supply system is provided by the developer, the location
and protection of the source as well as the design, construction, and operation
of the system shall conform to the standards of the Maine Rules Relating to
Drinking Water (10144 A.C.M.R 231).
M.
UTILITIES
1.
Any utility installations above ground shall be located so as to have a harmo
nious relation to neighboring properties and the site.
2.
The size, type, and location of street lights and underground utilities shall be
shown on the Final Plan and approved by the Planning Board.
N.
SIGN STANDARDS
Sign shall comply with the Town of Newry Sign Ordinance.
O.
LIGHTING DESIGN STANDARDS
1.
In connection with each site plan, the applicant shall submit plans for all pro
posed exterior lighting. These plans shall include the location, type of light, ra
dius of light, manufacturer's specification sheet and the intensity in foot-can
dles.
2.
All exterior lighting shall be designed, shielded or hooded and located and
maintained to avoid undue glare, adverse impacts on neighboring properties
and rights-of-ways, and the unnecessary lighting of night sky.
3.
All exterior lighting shall be designed to minimize adverse impact on neighbor
ing properties.
P.
DUST, FUMES, VAPORS, GASES, ODORS, GLARE, AND EXPLOSIVE MATERI
ALS
1.
Emission of dust, dirt, fly ash, fumes, vapors or gases which unreasonably af
fect human health, animals, vegetation or property or which could soil or stain
persons or property, at any point beyond the lot line of the commercial or indus
trial establishment creating that emission, shall be prohibited.
2.
No land use or establishment shall be permitted to produce unreasonable of
fensive or harmful odors perceptible beyond their lot lines, measured either at
ground or habitable elevation, excepting normal agricultural practices.
May 12, 2026
Section: 18 | 119
3.
No land use or establishment shall be permitted to produce a strong, dazzling
light or reflection of that light beyond its lot lines onto neighboring properties or
onto any private or public road so as to impair the vision of the driver of any ve
hicle upon that private or public road.
4.
No highly flammable or explosive liquids, solids or gases shall be stored in bulk
above ground, unless they are stored in compliance with the current require
ments of the National Fire Protection Association (NFPA) and the State of
Maine.
Q.
RESERVED
R.
REFUSE DISPOSAL
Construction and demolition debris disposal shall be paid for by the owner/applicant
through the use of a roll-off and private disposal company. If, in the future, the town es
tablishes a way to assess a fee for the town's waste disposal system, then disposal
through the town may become an option.
The applicant shall provide for the disposal of all hazardous, solid and liquid wastes on a
timely basis and in an environmentally safe manner. The Planning Board shall consider
the impact of particular industrial or chemical wastes or by-products upon the town's
waste disposal system (in terms of volume, flammability or toxicity) and may require the
applicant to dispose of such wastes elsewhere, in conformance with all applicable state
and federal regulations. The Planning Board may require the applicant to specify the
amount and exact nature of all industrial or chemical and hazardous wastes to be gener
ated by the proposed operation.
S.
PROTECTION OF SIGNIFICANT FISHERIES AND WILDLIFE HABITAT
Applicants proposing to develop land in or within 75 feet of fish or wildlife resources iden
tified in the Newry Comprehensive Plan or by the Maine Department of Inland Fisheries
and Wildlife shall consult with a recognized wildlife or fisheries consultant or the Maine
Department of Inland Fisheries and Wildlife and provide their written comments to the
Planning Board. The Planning Board may consult with the Maine Department of Inland
Fisheries and Wildlife and may impose any recommendations by the Maine Department
or consultant as conditions of approval.
T.
SCENIC LOCATIONS
The Planning Board shall consider the existence of a scenic site or view location as iden
tified in the Newry Comprehensive Plan and the impact of the proposed development on
such a site or view. The Planning Board may require the placement or visual qualities of
120 | Unified Development Review Ordinance
structures on lots in such locations as to minimize the negative impacts of the develop
ment on such sites and views.
U.
ARCHAEOLOGICAL SITES
Any development activity involving structural development or soil disturbance on or adja
cent to sites listed on, or eligible to be listed on the National Register of Historic Places,
as determined by the Planning Board shall be submitted by the applicant to the Maine
Historic Preservation Commission for review and comment, at least 20 days prior to ac
tion being taken by the permitting authority. The Planning Board shall consider comments
received from the Commission prior to rendering any decision on the application.
V.
HISTORIC LOCATIONS
The Planning Board shall consider the proposed subdivision's impacts on historic build
ings and sites as identified in the Newry Comprehensive Plan. When a proposed devel
opment will include a historic building or site the applicant will design the development to
minimize the impacts on the historic building or site.
W.
AGRICULTURAL PROTECTION BUFFER STRIPS
The Planning Board may require buffer strips to separate new uses and agricultural uses.
The purpose of the buffer strips is to separate new development that could conflict with
active agricultural uses. In determining the width of the buffer strips and the uses allowed
in the buffer strips, including wells, the Nutrient Management Law and Nutrient Manage
ment Rules shall be considered by the Planning Board.
X.
VEHICULAR AND PEDESTRIAN TRAFFIC
When conflicts exist between this Section and a Driveway Permit or Entrance Permit onto
Routes 2 and 26 or the Sunday River Road to the Ski Way Road issued by the Maine De
partment of Transportation, the most stringent or restrictive shall apply.
1.
Roads shall be designed and constructed to meet the minimum standards as
provided for in §19, Road Design and Construction Standards.
2.
In general, provision shall be made for vehicular access to the development
and circulation within the development in such a manner as to:
a.
Safeguard against hazards to traffic and pedestrians on existing roads
and within the development.;
b.
Minimize traffic congestion on any road;
c.
Provide safe and convenient circulation on public roads and within the de
velopment;
May 12, 2026
Section: 18 | 121
d.
Discourage through traffic in residential subdivisions; and
e.
Should street lighting be required by the Planning Board it shall be in
stalled by the developer as approved by the Planning Board. The cost of
installation shall be the responsibility of the developer and comply with
municipal specifications.
3.
Access Control.
a.
Where a lot has frontage on two or more roads, the access to the lot shall
be provided to the lot across the frontage and to the road where there is
lesser potential for traffic congestion and for hazards to traffic and pedes
trians. This restriction shall be a condition of plan approval and as a deed
restriction to the affected lots.
b.
The Planning Board may require, based upon site distances and volume
of traffic, the use of shared or common driveways, where such lots will be
accessed by off-site roads.
c.
Where new road intersections or driveway curb cuts are proposed, site
distances, as measured along the road onto which traffic will be turning,
shall be in accordance with Section 18, Road Design and Construction
Standards.
4.
Sidewalks or pedestrian easements may be required by the Planning Board to
provide safe and convenient access to common areas, existing roads, play
grounds, or other public/private facilities.
Y.
GROUND WATER PROTECTION
The following standards shall be utilized by the Planning Board for reviewing develop
ment applications located on a mapped sand and gravel aquifer
1.
The boundaries of sand and gravel aquifers shall be as delineated on the most
recent Sand and Gravel Aquifer Maps prepared by the Maine Geological Sur
vey.
2.
When the boundaries of the sand and gravel aquifer are disputed due to lack of
sufficient detail on available maps, the applicant or agent may submit hydro ge
ologic evidence prepared by a geologist certified in the State of Maine which
identifies actual field locations of the aquifer boundaries within the project area.
The Planning Board may require actual field identification if they believe the
Maine Geological Survey Maps are incorrect.
122 | Unified Development Review Ordinance
3.
Based on the size, location, surrounding uses or other characteristics of the
proposed use or site to determine compliance with the requirements of this
section, the Planning Board may require submittal by the applicant of a hydro
geologic impact study. The impact study shall be prepared by a State of Maine
Certified Geologist with experience in hydro geology. The study shall contain
the following components unless waived by a specific vote of the Planning
Board.
a.
A map showing: (1) soil types; (2) surficial geology on the property; (3) the
recommended sites for individual subsurface waste water disposal sys
tems and wells in the development; and (4) direction of ground water flow.
(The Planning Board expects the detail of this study to vary with the inten
sity of the development.)
b.
The relationship of surface drainage conditions to ground water condi
tions.
c.
Documentation of existing ground water quality for the site.
d.
A nitrate nitrogen analysis or other contaminant analysis as applicable in
cluding calculation of levels at the property line(s) and well(s) on the prop
erty.
e.
A statement indicating the potential sources of contamination to ground
water from the proposed use and recommendations on the best technolo
gies to reduce the risks.
f.
For water intensive uses, analysis of the effects of aquifer drawdown on
the quantity and quality of water available for other water supplies or po
tential water supplies.
g.
The Planning Board may require installation and regular sampling of water
quality monitoring wells for any use or proposed use deemed to be a sig
nificant actual or potential source of pollutants or excessive drawdown.
The number, location and depth of monitoring wells shall be determined
as part of the hydro geologic study, and wells shall be installed and sam
pled in accordance with "Guidelines for Monitoring Well Installation and
Sampling" (Tolman, Maine Geologic Survey, 1983). Water quality sample
results from monitoring wells shall be submitted to the Code Enforcement
Officer with evidence showing that contaminant concentrations meet the
performance standard for pollution levels.
h.
A list of assumptions made to produce the required information.
4.
Conditions/Standards
May 12, 2026
Section: 18 | 123
a.
No use including home occupations shall dispose of other than normal do
mestic waste water on-site without approval of the permit granting author
ity. Disposal of waste water shall be in strict compliance with the Maine
Subsurface Wastewater Disposal Rules and other relevant State and local
laws, rules and ordinances.
b.
Indoor use or storage facilities where hazardous materials, wastes or
other liquids with the potential to threatened ground water quality are used
or stored shall be provided with containment which is impervious to the
material being stored and have the capacity to contain 10 percent of total
volume of the containers, or 110 percent of the volume of the largest con
tainer, whichever is larger.
c.
Petroleum and Other Hazardous Material or Waste Transfer. A Spill Con
trol and Countermeasure Plan shall be submitted and approved by the
Planning Board.
d.
In those areas identified as sand and gravel aquifers the following land
uses are prohibited unless the Planning Board finds that no discharges
will occur such that water quality at the property line will fall below State
Drinking Water Standards and all provisions of this ordinance are met.
i.
dry cleaners,
ii.
photo processors,
iii.
printers,
iv.
auto washes,
v.
laundromats,
vi.
salt piles, sand-salt piles,
vii.
wood preservers,
viii.
industrial waste disposal/impoundment areas,
ix.
landfills, dumps, transfer stations,
x.
junk and salvage yards graveyards,
xi.
concrete/asphalt/tar/coal companies.
Z.
NOISE
The proposed development shall not raise noise levels to the extent that abutting or
nearby residents are adversely affected.
124 | Unified Development Review Ordinance
1.
Sound Level Limits
a.
Sound from Routine Operation of Facility.
The hourly sound levels resulting from routine operation of the facility and
measured in accordance with the measurement procedures described in
subsection 4 (Measurement Procedures) shall not exceed the following limits:
The hourly sound levels resulting from routine operation of the Facility shall not
exceed the following limits at that Protected Location:
i.
55 dBA between 7:00 a.m. and 10:00 p.m. (the "daytime hourly
limit"), and
ii.
45 dBA between 10:00 p.m. and 7:00 a.m. (the "nighttime hourly
limit").
For the purposes of determining compliance with the above sound level limits,
5 dBA shall be added to the measured levels of any tonal sounds that result
from routine operation of the facility.
b.
When routine operation of a facility produces short duration repetitive
sound, that due to their character and/or duration, are particularly annoy
ing or pose a threat to the health and welfare of nearby neighbors, 5 dBA
shall be added to the observed levels of the short duration repetitive
sounds that result from routine operation of the facility . The maximum
sound level of the short duration repetitive sounds shall not exceed the
following limits:
i.
65 dBA between 7:00 a.m. and 10:00 p.m., and
ii.
55 dBA between 10:00 p.m. and 7:00 a.m.
2.
Sound from Construction and Maintenance of a Facility
a.
The sound from construction activities between 7:00 p.m. and 7:00 a.m. is
subject to the following limits:
i.
Sound from nighttime construction activities shall be subject to the
nighttime routine operation sound level limits contained in subsec
tions 1.a.
ii.
If construction activities are conducted concurrently with routine op
eration of the facility, then the combined total of construction and rou
tine operation sound shall be subject to the nighttime routine opera
tion sound level limits contained in subsections 1.a.
May 12, 2026
Section: 18 | 125
iii.
Higher levels of nighttime construction sound are permitted when a
duly issued permit authorizing nighttime construction sound in ex
cess of these limits has been granted by the Codes Enforcement Of
ficer.
b.
Sound from construction activities between 7:00 a.m. and 7:00 p.m. shall
not exceed the following limits at any Protected Location:
Duration of Activity
Hourly Sound Level Limit
12 hours
87 dBA
8 hours
90 dBA
6 hours
92 dBA
4 hours
95 dBA
3 hours
97 dBA
2 hours
100 dBA
1 hour or less
105 dBA
c.
All equipment used in construction on the facility site shall comply with ap
plicable federal noise regulations and shall include environmental noise
control devices in proper working condition, as originally provided with the
equipment by its manufacturer.
d.
Sound from routine, ongoing maintenance activities shall be considered
part of the routine operation of the facility and the combined total of the
routine maintenance and operation sound shall be subject to the routine
operation sound level limits contained in section 1.
e.
Sound from occasional, major, scheduled overhaul activities shall be sub
ject to the construction sound level limits contained in section 2.b. If over
haul activities are conducted concurrently with routine operation and/or
construction activities, the combined total of the overhaul, routine opera
tion and construction sound shall be subject to the construction sound
level limits contained in section 2.b
3.
The following uses and activities shall be exempt from the sound pressure level
regulations:
a.
The noises of safety signals, warning devices and emergency reassure
relief valves and any other emergency activity.
126 | Unified Development Review Ordinance
b.
Traffic noise on roads.
c.
Noise associated with snowmaking.
d.
Noise associated with competitive, demonstration or exhibition snow
events.
4.
Measurement Procedures
a.
Scope. These procedures specify measurement criteria and methodology
for use, with applications, compliance testing and enforcement. They pro
vide methods for measuring the ambient sound and the sound from rou
tine operation of the facility, and define the information to be reported.
The same methods shall be used for measuring the sound of construction
and maintenance activities.
b.
Measurement Criteria
i.
Measurement Personnel
Measurements shall be by personnel who hold professional qualifications in
measurement and evaluation of environmental sound.
ii.
Measurement Instrumentation
(1)
A sound level meter or alternative sound level measure
ment system used shall meet all of the Type 1 or 2 perfor
mance requirements of American National Standard Spec
ifications for Sound Level Meters, ANSI S1.4-1983.
(2)
An integrating sound level meter (or measurement system)
shall also meet the Type 1 or 2 performance requirements
for integrating/averaging in the International Electrotechni
cal Commission Standard on Integrating-Averaging Sound
Level Meters, IEC Publication 804 (1985).
(3)
A filter for determining the existence of tonal sounds shall
meet all the requirements of-American National Standard
Specification for Octave-Band and Fractional Octave-Band
Analog and Digital Filters, ANSI S1.11-1986 for Order 3,
Type 3-D performance.
(4)
An acoustical calibrator shall be used of a type recom
mended by the manufacturer of the sound level meter and
that meets the requirements of American National Stan
May 12, 2026
Section: 18 | 127
dard Specification for Acoustical Calibrators, ANSI S1.40-
1984.
(5)
A microphone windscreen shall be used of a type recom
mended by the manufacturer of the sound level meter.
iii.
Calibration
(1)
The sound level meter shall have been calibrated by a lab
oratory within 12 months of the measurement, and the mi
crophone's response shall be traceable to the National Bu
reau of Standards.
(2)
Field calibrations shall be recorded before and after each
measurement period and at shorter intervals if recom
mended by the manufacturer.
iv.
Measurement Location, Configuration and Environment
(1)
Except as noted in subsection (ii) below, measurement lo
cations shall be at nearby Protected Locations that are
most likely affected by the sound from routine operation of
the facility.
(2)
For determining compliance with the 75 dBA Protected Lo
cation hourly sound level limit described in subsection
1.a.i, measurement locations shall be selected at the Pro
tected Locations of the proposed facility or contiguous
property owned by the Applicant, as appropriate.
(3)
The microphone shall be positioned at a height of approxi
mately 4 to 5 feet above the ground, and oriented in accor
dance with the manufacturer's recommendations.
(4)
Measurement locations should be selected so that no ver
tical reflective surface exceeding the microphone height is
located within 30 feet. When this is not possible, the mea
surement location may be closer than 30 feet to the reflec
tive surface, but under no circumstances shall it be closer
than 6 feet.
(5)
When possible, measurement locations should be at least
50 feet from any regulated sound source on the facility.
128 | Unified Development Review Ordinance
(6)
Measurement periods shall be avoided when the local
wind speed exceeds 12 mph and/or precipitation would af
fect the measurement results.
c.
Measurement of Ambient Sound
i.
Pre-development Ambient Sound
(1)
Measurements shall be made at representative Protected
Locations for periods of time sufficient to adequately char
acterize the ambient sound. At a minimum, measure
ments shall be made on three different weekdays (Monday
through Friday) during all hours that the facility will oper
ate. If the proposed facility will operate on Saturdays
and/or Sundays, measurements shall also be made during
all hours that the facility will operate.
(2)
Measurement periods with particularly high ambient
sounds, such as significant insect activity should generally
be avoided.
(3)
At any measurement location the daytime and nighttime
ambient hourly sound level shall be computed by arith
metically averaging the daytime and nighttime values of
the measured one hour equivalent sound levels. Multiple
values, if they exist, for any specific hour on any specific
day shall first be averaged before the computation de
scribed above.
ii.
Post-Facility Ambient Sound
(1)
Measurements of the post-facility ambient one hour equiv
alent sound levels and, if short duration repetitive sounds
are produced by the facility, the maximum sound levels
made at nearby Protected Locations and during represen
tative routine operation of the facility that are not greater
than the applicable limits of section 3 clearly indicate com
pliance with those limits.
(2)
Compliance with the limits of subsection 1.a may also be
demonstrated by showing that the post-facility ambient
hourly sound level, measured in accordance with the pro
cedures of subsection c.i above during routine operation of
the facility, does not exceed the pre-development ambient
May 12, 2026
Section: 18 | 129
hourly sound level by more than one decibel, and that the
sound from routine operation of the facility is not charac
terized by either tonal sounds or short duration repetitive
sounds.
(3)
Compliance with the limits of section 1.a.i.(b) may also be
demonstrated by showing that the post facility maximum
sound level of any short duration repetitive sound, mea
sured in accordance with the procedures of subsection c.i
above, during routine operation of the facility, does not ex
ceed the pre-development ambient hourly sound level by
more than five decibels.
iii.
If any of the conditions in (a), (b) or (c) above are not met, compli
ance with respect to the applicable limits must be determined by
measuring the sound from routine operation of the facility in accor
dance with the procedures described in section 4.
d.
Measurement of the Sound from Routine Operation of Facility.
i.
General
(1)
Measurements of the sound from routine operation of facil
ities are generally necessary only for specific compliance
testing purposes in the event that community complaints
result from operation of the facility, for validation of an Ap
plicant's calculated sound levels when requested by the
planning board, for determination of existing hourly sound
levels for an existing facility or for enforcement by the
Codes Enforcement Officer.
(2)
Measurements shall be obtained during representative
weather conditions when the facility sound is most clearly
noticeable. Preferable weather conditions for sound mea
surements at distances greater than about 500 feet from
the sound source include overcast days when the mea
surement location is downwind of the facility and inversion
periods (which most commonly occur at night).
(3)
Measurements of the facility sound shall be made so as to
exclude the contribution of sound from facility equipment
that is exempt from this regulation.
ii.
Measurement
130 | Unified Development Review Ordinance
(1)
When the ambient sound levels are greater than the sound
level limits, additional measurements can be used to de
termine the hourly sound level that results from routine op
eration of the facility. These additional measurements may
include diagnostic measurements such as measurements
made close to the facility and extrapolated to the Protected
Location, special check mark measurement techniques
that include the separate identification of audible sound
sources, or the use of sound level meters with pause ca
pabilities that allow the operator to exclude non-facility
sounds.
(2)
For the purposes of computing the hourly sound level re
sulting from routine operation of the facility, sample diag
nostic measurements may be made to obtain the one hour
equivalent sound levels for each sound component.
(3)
Identification of tonal sounds produced by the routine op
eration of a facility for the purpose of adding the 5 dBA
penalty in accordance with section 1.a.i.(a) requires aural
perception by the measurer, followed by use of one-third
octave band spectrum analysis instrumentation. If one or
more of the sounds of routine operation of the facility are
found to be tonal sounds, the hourly sound level compo
nent for tonal sounds shall be computed by adding 5 dBA
to the one hour equivalent sound level for those sounds.
(4)
Identification of short duration repetitive sounds produced
by routine operation of a facility requires careful observa
tions. For the sound to be classified as short duration
repetitive sound, the source(s) must be inherent to the
process or operation of the facility and not the result of an
unforeseeable occurrence. If one or more of the sounds of
routine operation of the facility are found to be short dura
tion repetitive sounds, the hourly sound level component
for short duration repetitive sounds shall be computed by
adding 5 dBA to the one hour equivalent sound level for
those sounds. If required, the maximum sound levels of
short duration repetitive sounds shall be measured using
the fast response [LAFmax]. The duration and the fre
quency of occurrence of the events shall also be mea
sured. In some cases, the sound exposure levels of the
May 12, 2026
Section: 18 | 131
events may be measured. The one hour equivalent sound
level of a short duration repetitive sound may be deter
mined from measurements of the maximum sound level
during the events, the duration and frequency of occur
rence of the events, and their sound exposure levels.
(5)
The daytime or nighttime hourly sound level resulting from
routine operation of a facility is the energy sum of the
hourly sound level components from the facility, including
appropriate penalties, (see (c) and (d) above). If the en
ergy sum does not exceed the appropriate daytime or
nighttime sound level limit, then the facility is in compli
ance with that sound level limit at that Protected Location.
e.
Reporting Sound Measurement Data. The sound measurement data re
port should include the following:
i.
The dates, days of the week and hours of the day when measure
ments were made.
ii.
The wind direction and speed, temperature, humidity and sky condi
tion.
iii.
Identification of all measurement equipment by make, model and se
rial number.
iv.
The most recent dates of laboratory calibration of sound level mea
suring equipment.
v.
The dates, times and results of all field calibrations during the mea
surements.
vi.
The applicable sound level limits, together with the appropriate
hourly sound levels and the measurement data from which they were
computed, including data relevant to either tonal or short duration
repetitive sounds.
vii.
A sketch of the site, not necessarily to scale, orienting the facility, the
measurement locations, topographic features and relevant distances,
and containing sufficient information for another investigator to re
peat the measurements under similar conditions.
viii.
A description of the sound from the facility and the existing environ
ment by character and location.
132 | Unified Development Review Ordinance
AA. BUFFERS AND SCREENING STANDARDS
Buffers may be considered in or for the following areas and purposes:
1.
Along property lines to shield incompatible uses from each other;
2.
Along interior roads running parallel to roads exterior to the site, to prevent con
fusion, particularly at night;
a.
Parking areas, garbage collection areas, and loading and unloading ar
eas; and
b.
To block prevailing wind patterns and to stop wind-borne debris from leav
ing the site.
3.
Buffers in the form of fences, landscaping, berms and mounds may be required
to minimize any adverse impacts or nuisance on the site of on adjacent proper
ties.
4.
All plantings shall be of a type and species appropriate for the soil types and
climatic conditions in the Town of Newry.
5.
Buffers shall be sufficient to shield structures and uses from the view of incom
patible abutting properties and public road ways, and to otherwise prevent any
nuisances.
6.
Exposed storage areas, service areas, exposed machinery installation, sand
and gravel extraction operations, truck-loading areas, utility buildings and struc
tures, and areas used for the storage or collection of discarded automobiles,
auto parts, metals or any other articles of salvage or refuse, and similar acces
sory areas and structures, shall have sufficient setbacks and screening to pro
vide an audio/visual buffer sufficient to minimize their adverse impact on other
land uses within the development site and surrounding properties, such as a
stockade fence or a dense evergreen hedge six (6) feet or more in height.
7.
Where a potential safety hazard to children would be likely to arise, physical
screening sufficient to deter small children from entering the premises shall be
provided and shall be maintained in good condition.
8.
Natural features shall be maintained wherever possible to provide a buffer be
tween the proposed development and incompatible abutting properties and
public roadways. When natural features such as topography, gullies, stands of
trees, shrubbery, rock outcrops do not exist or are insufficient to provide a buf
fer, other kinds of buffers shall be considered.
May 12, 2026
Section: 18 | 133
9.
Evergreens can be used as buffers, provided they are planted properly. An ev
ergreen buffer requires two (2) or more rows of staggered plantings. The rows
should be a maximum of five (5) feet apart and the evergreens planted a maxi
mum distance of four (4) feet on center, or an alternative spacing as approved
by the Planning Board based on the approved plant species. Evergreens shall
be a minimum of six (6) feet high at the time of planting.
10.
Fencing and screening shall be durable and properly maintained at all time by
the owner. Fencing and screening shall be so located within the property line
to allow access for maintenance on both sides without intruding upon abutting
properties.
11.
All buffer areas shall be maintained in a neat, sanitary, and vigorous condition
by the owner.
134 | Unified Development Review Ordinance
SECTION 19: ROAD DESIGN AND CONSTRUCTION STANDARDS
SECTION USER'S GUIDE: This section contains specific road design and con
struction standards applicable to all developments requiring approval under this
Ordinance, particularly subdivisions.
A.
GENERAL REQUIREMENTS
1.
The Planning Board shall not approve any development plan unless proposed
roads are designed in accordance with the specifications contained in this Ordi
nance.
2.
Existing and proposed roads and intersections that can be expected to carry
traffic generated by a subdivision or site plan review shall have the capacity or
be suitably improved to accommodate that traffic and avoid unreasonable con
gestion. For the purposes of this section, "suitably improved" shall mean that all
of the existing and proposed private roads in the road network back to the clos
est public road shall meet the applicable primary, secondary or neighborhood
road standards, as appropriate in this ordinance.
3.
When existing roads or roads right-of-way are utilized as secondary or neigh
borhood roads in a proposed subdivision or site plan review, a road or road
right-of-way of three rods (49.5 feet) in width will be considered to be accept
able under these standards, however, any such preexisting road or road right-
of-way of lesser width shall be evaluated based on conformance of the road
design and construction standards for assurance of public safety and sound
construction.
4.
Approval of an application by the Planning Board shall not be deemed to con
stitute or be evidence of acceptance by the Town of any road or easement.
5.
Applicants shall submit to the Planning Board, as part of their Final Plan, de
tailed construction drawings showing a plan view, profile, and typical cross-sec
tion of the proposed roads, parking areas, and utilities. The plans shall include
the following information:
a.
Date, scale, and magnetic or true north point.
b.
Intersections of the proposed road with existing roads.
c.
Roadway and right-of-way limits including edge of pavement, edge of
shoulder, sidewalks, and curbs.
d.
Complete curve data shall be indicated for all horizontal and vertical
curves.
May 12, 2026
Section: 19 | 135
e.
Turning radii at all intersections.
f.
Center line gradients.
g.
Locations of all existing and proposed overhead and underground utilities.
h.
Cistern and fire pond design, sizing, and locations.
6.
Upon receipt of plans for a proposed public road the Planning Board shall for
ward one copy to the Select Board and the Road Commissioner for review and
comment. Plans for roads which are not proposed to be accepted by the Town
shall be sent to the Road Commissioner for review and comment.
B.
ROAD DESIGN STANDARDS
1.
These design standards shall be met by all roads within developments re
viewed under this Ordinance, and shall control the roadway, shoulders, curbs,
sidewalks, drainage systems, culverts, and other appurtenances.
2.
Where a development borders an existing narrow road (not meeting the width
requirements of the standards for roads, in this Ordinance), or when the Com
prehensive Plan indicates plans for realignment or widening of a road that
would require use of some of the land in the development, the development
plan shall indicate reserved areas for widening or realigning the road marked
"Reserved for Road Realignment (Widening) purposes." Land reserved for
such purposes may not be included in computing lot area of setback require
ments of this Ordinance.
3.
Where a major subdivision or development abuts or contains an existing Town
Road or State Highway, no residential lot may have vehicular access directly
on to the Town Road or State Highway except where land use or topographic
conditions warrant otherwise. This requirement shall be noted on the Plan and
the deeds of any lot with frontage on the Town Road or State Highway.
4.
The following design standards apply according to road classification:
Description
Primary
Secondary
Neighborhood
Number of Lanes
2
2
2
Right-of-Way Width
60 ft.
50 ft.
50 ft.
Traveled Way
22 ft.
20 ft.
18 ft.
Minimum Shoulder Width (each side)
4 ft.
2 ft.
2 ft.
Minimum Grade (for drainage)
0.5%
0.5%
0.5%
136 | Unified Development Review Ordinance
Description
Primary
Secondary
Neighborhood
Maximum Grade¹
12%
15%
15%
Maximum Superelevation
0.08°/ft.
0.08°/ft.
0.08°/ft.
Minimum Center Line Radius on
Curves
200 ft.²
150 ft.²
150 ft.²
Roadway Crown:
Paved Surface
1.5 - 3.0%
1.5 - 3.0%
1.5 - 3.0%
Gravel Surface
2.0 - 6.0%
2.0 - 6.0%
2.0 - 6.0%
Minimum Angle of Intersection
80°
80°
80°
Minimum Distance Between Road In
tersections:
Same Side
400 ft.
300 ft.
300 ft.
Opposite Side
200 ft.
150 ft.
150 ft.
Maximum Grade Within 75 ft. of Road
Intersection1
3%
4%
5%
Maximum Hydrant Pad Slope
2%
2%
2%
Curb Radii:
90° Intersections
25 ft.
25 ft.
25 ft.
80-90° Intersections
30 ft.
30 ft.
30 ft.
90-105° Intersections
30 ft.
30 ft.
30 ft.
Minimum Right-of-Way Radius at In
tersections
20 ft.
20 ft.
20 ft.
Dead-End Road:
Minimum Radius at Turn-Around
86 ft.
86 ft.
86 ft.
Outside Edge of Travel Way
70 ft.
70 ft.
70 ft.
Maximum Grade of Turn-Around2
3%
4%
4%
Sidewalk Width
5 ft.
5 ft.
5 ft.
Overhead Clearance
15 ft.
15 ft.
15 ft.
Bridge Clearance3
15 ft.
15 ft.
15 ft.
Vertical Curve (Minimum "K" Value)
Crest
55 ft.
29 ft.
12 ft.
May 12, 2026
Section: 19 | 137
Description
Primary
Secondary
Neighborhood
Sag
55 ft.
49 ft.
26 ft.
Notes:
1
This standard applies to road intersections to any non-town maintained primary,
secondary and/or neighborhood road. The standard shall not exceed 3% for road inter
sections to any town maintained road or road proposed to be town maintained.
2
The standard shall not exceed 3% for any road proposed to be town maintained.
3
Minimum overhead clearance of bridges is 15 feet and if the bridge occurs over a
sag vertical curve added clearance shall be given to allow for 60 foot axle separations.
5.
Maximum grades on Primary and Secondary roads shall be as follows:
a.
For any 1/2 mile segment of road the average overall grade shall be 10%.
b.
A grade of 12% is permitted for 1000 feet.
c.
A grade of 15% is permitted for 150 feet.
6.
If the road grade exceeds 5%, then the minimum center line radius on curves
shall be increased by 50 feet for each additional 1% of grade.
7.
The distance between the profile centerline and the right-of way centerline for
an as built primary roadway shall be no more than 7.5 feet. The distance be
tween the profile centerline and right-of-way centerline for an as-built sec
ondary and neighborhood dead end roadway shall be no more than 5 feet.
8.
Dead End Roads
a.
If a road is to be dead-end then a cul-de-sac or hammerhead turnaround
must be built at the end of the dead-end. The cul-de-sac must have an
eighty-six (86) foot property line radii and a seventy (70) foot outer edge of
travel way radii as drawn in Appendix 1, Exhibit A to the ordinance. A
hammerhead turnaround must have a minimum traveled way and right-of-
way as drawn in Appendix 1, Exhibit B-1 or B-2 to the ordinance.
Cul-de-sacs shall only be used at the end of dead end roads.
All traveled ways of turnarounds shall be kept free and clear of snow and debris
at the responsibility of the property owner.
b.
The Planning Board may require the reservation of a twenty (20) foot
easement in line with the dead-end road to provide continuation of pedes
trian traffic or utilities to the next road. The Planning Board may also re
138 | Unified Development Review Ordinance
quire the reservation of fifty (50) foot easement in line with the dead-end
road to provide continuation of the road where future subdivision or devel
opment is possible.
9.
Grades, Intersections and Sight Distances
a.
Grades of all roads shall conform in general to the terrain, so that cut and
fill are minimized while maintaining the grade standards above.
b.
All changes in grade shall be connected by vertical curves to provide for
the minimum sight distances below.
c.
Where new road intersections or curb-cuts are proposed, sight distances
for all roads, shall be based upon the posted speed limit and conform to
the table below:
POSTED SPEED LIMIT
(MPH)
15
20
25
30
35
40
45
SIGHT DISTANCE
(FEET)
150
155
200
250
305
360
425
Where necessary, corner lots shall be cleared of all growth and sight obstructions,
including ground excavation, to achieve the required visibility.
d.
Cross (four-cornered) road intersections shall be avoided, except as
shown on the Comprehensive Plan or at other important traffic intersec
tions.
e.
All intersections shall have roads meeting at a minimum intersecting angle
of 80 degrees except where an acceleration lane is designed.
f.
Guard rails shall be installed where a side slope of greater than 3 to 1 is
designed or an area of special hazard exists. Guard rails shall be a mini
mum of 4 feet from the edge of pavement and built to Maine Department
of Transportation standards.
g.
Above ground utilities shall be a minimum of 20 feet from the centerline of
the road.
h.
Manhole covers shall be 1/2 inch below finished grade within the right of
way and shown on the road plan.
10.
Where installed, curbing shall be granite or bituminous concrete and shall be
installed on a thoroughly compacted gravel base of six (6) inches minimum
thickness, except bituminous curbing shall be installed on the base course of
May 12, 2026
Section: 19 | 139
the pavement. The specified pavement's width above shall be measured be
tween the curbs.
C.
ROAD CONSTRUCTION STANDARDS
1.
Minimum Thickness of Material After Compaction¹
ROAD MATERIALS
Primary
Secondary
Neighborhood
Aggregate Sub-Base Course,
Maximum sized stone is 4"
24 in.
18 in.
15 in.
Crushed Aggregate Base
Course²
2 in.
2 in.
2 in.
Hot Bituminous Pavement:
Total Thickness
2.5 in.
2 in.
2 in.
Surface Course
1 in.
0.5 in.
0.5 in.
Crushed Gravel Surface²
4 in.
4 in.
4 in.
Notes:
1 Compaction shall meet DOT Standards
2 Materials testing and compaction testing shall be completed by an independent
testing company, as selected by the Town of Newry, at the developer's expense.
Documentation shall be provided to the Town.
2.
Preparation:
a.
Before any clearing begins, the centerline and side lines of the new road
shall be staked or flagged at 50-foot intervals.
b.
Before grading begins, the entire right of way, width necessary for travel
way, shoulders, sidewalks, drainageways, and utilities, shall be cleared of
all stumps, roots, brush or other objectionable material. All shallow ledge,
large boulders, and stumps protruding above the natural profile of the land
shall be removed from the travelway, shoulders, sidewalks, and drainage
areas.
c.
All organic materials shall be removed to a depth as required by the
above road construction standards, at a minimum. On soils which have
been identified as not suitable for roadways, the subsoil and organic ma
terials shall be removed from the travelway, shoulders, sidewalks and
drainage areas to a depth of two feet below the subgrade, and replaced
140 | Unified Development Review Ordinance
with material meeting the specifications for gravel aggregate sub-base, as
identified above.
d.
Slope easements may be required to facilitate maintenance of Town
roads. Slopes from shoulder to ditch bottom and ditch back slopes shall
not be steeper than three feet horizontal to one foot vertical where possi
ble. Roadside ditches shall be designed in accordance with MaineDOT
design guidelines and BMPs.
e.
All underground utilities should be installed prior to paving to avoid cuts in
the pavement. Building sewers and water service connections should be
installed to the edge of the right-of-way prior to paving.
Culverts shall:
i.
Conform to Maine Department of Transportation (MaineDOT) Stan
dard Specification Section 603 (Culverts and Storm Drains) and Sec
tion 700 (Materials).
ii.
Maintain a minimum internal diameter of 15 inches.
iii.
Be constructed of Reinforced Concrete Pipe (RCP) or Corrugated
Polyethylene Pipe (Option III) as specified in § 706.02 or § 706.06.
iv.
Corrugated Metal Pipe (CMP) may only be used if specifically permit
ted by the Inspecting Official or if diameters exceed 60 inches, pro
vided they meet the requirements of § 707.
v.
Be sized according to the MaineDOT Drainage Manual and the spe
cific hydraulic design criteria established for the project to manage
peak flow events (e.g., Q50 or Q100).
vi.
Be installed in accordance with §603.03 (Construction Require
ments), ensuring proper bedding, jointing, and backfilling.
vii.
Be installed with appropriate inlet and outlet protection (such as
Riprap conforming to § 610) to prevent scour and erosion of the sur
rounding soil and channel, in compliance with §656.
3.
Bases, Pavements and Curbs:
a.
Pavement Joints - Where pavement joins an existing pavement, the exist
ing pavement shall be cut along a smooth line and form a neat, even verti
cal joint.
May 12, 2026
Section: 19 | 141
b.
Curbs and Gutters - Road curbs and gutters shall be installed as required
by the Planning Board. Curbs shall be vertical except when sloped curbs
are specifically allowed by the Planning Board.
c.
Pavements - All road surfaces that are to be paved shall be given a bitu
minous surface treatment in accordance with the State of Maine, Depart
ment of Transportation Standard Specifications.
D.
CLEANUP
Following road construction, the developer or contractor shall conduct a thorough clean-
up of stumps and other debris from the entire road right-of-way. If on-site disposal of the
stumps and debris is proposed, the site shall be indicated on the Plan, and be suitably
covered with fill and topsoil, limed fertilized, and seeded.
E.
ROAD NAMES AND SIGNS
Roads which join and are in alignment with roads of abutting or neighboring properties
shall bear the same name. Names of new roads shall not duplicate, nor bear phonetic re
semblance to the names of existing roads within the Town, and shall be subject to the ap
proval of the E 911 Addressing Officer. All road name, traffic safety and control signs
shall meet the specifications of the current Federal Highway Administration's Manual on
Uniform Traffic Control Devices. The developer shall install all required road name, traffic
safety and control signs or reimburse the Town for the costs of installing.
F.
CERTIFICATION OF CONSTRUCTION OF ROADS
Upon completion of road construction a written certification signed by a licensed profes
sional engineer registered in the State of Maine shall be submitted to the Select Board at
the expense of the applicant, certifying that the road meets or exceeds the design and
construction requirements of these regulations.
G.
ACCEPTANCE OF A ROAD BY THE TOWN TO BECOME A TOWN ROAD
Any owner or developer that wishes to have a road accepted as a town road must meet
the following requirements, and make a written petition to the Select Board with copies
sent to the Planning Board and Road Commissioner.
1.
Any new road must be paved and connect to an existing Town, County, or State
Road to be considered for acceptance as a Town Road.
2.
Prior to construction, the drawing of the proposed road showing that the owner
plans to meet all of the above minimum requirements and what action is to be
142 | Unified Development Review Ordinance
taken if any special conditions exist which are not included in the above mini
mum requirements shall be submitted to the Planning Board for review.
3.
The minimum right-of-way, 60' for a primary road and 50' for a secondary and
neighborhood road, will be deeded to the Town by warranty deed from the de
veloper or quitclaim deed from each abutting land owner upon acceptance of
the road as a Town Road. If the road is to be dead-end (does not connect to an
existing Town, County, or State Road on each end or does not connect to it
self), then either a cul-de-sac or a hammerhead turn around with right-of-ways
is to be deeded to the Town as a turn-around. (See Appendix 1. Exhibit A and
B for minimum radius, traveled way, and right-of-way requirements for turn
around.)
4.
A plan suitable for recording showing boundaries and their markers, drainage,
traveled ways, all underground utilities, etc., shall accompany the owners' peti
tion for a Town Road which is to be submitted to the Select Board.
5.
The road shall winter one season before being considered for acceptance to in
sure proper construction.
6.
Any new road must meet State of Maine Department of Transportation's com
paction rates prior to acceptance of the road by the Town to become a Town
Road and the owner or developer must submit a certification that meets §18.F
above.
7.
Approval for acceptance of a new or existing road as a Town Road is given by
majority vote of a duly called Town Meeting. Planning Board approval of a road
plan through either Site Plan Review or Subdivision Review does not constitute
approval for acceptance of a road as a Town Road.
8.
All road surfaces to be accepted as a Town Road shall be given a hot bitumi
nous surface treatment conforming to the specification set forth in the current
Standard Specification Highway and Bridges, State of Maine, Department of
Transportation.
9.
All striping and line work shall be painted by the developer and shall conform to
the specification set forth in the current State of Maine, Department of Trans
portation Standard Specification.
10.
A minimum of one granite monument to establish the right-of-way must be
placed by a licensed surveyor hired by the developer.
11.
"As built" plans shall be submitted to the Select Board for roads to be accepted
as a town road.
May 12, 2026
Section: 19 | 143
H.
PRIVATE ROADS
1.
Where the development roads are to remain private roads, the following words
shall appear on the recorded plan and deed:
"All roads in this development shall remain private roads to be main
tained by the developer or the lot/home owners at their sole cost and
expense unless accepted by the vote of the Town."
2.
Certification as per §18.F. above apply to all roads within a development,
whether they are to become public roads or remain as private roads.
144 | Unified Development Review Ordinance
SECTION 20: PARKING AND ENTRANCE DESIGN STANDARDS
SECTION USER'S GUIDE: This section contains specific parking area and site en
trance design and construction standards applicable to those development
projects proposing and/or requiring on-site, off-street parking and road entrances.
A.
GENERAL REQUIREMENTS
1.
A use shall not be established or extended and no structure shall be con
structed or enlarged unless sufficient off-street automobile parking space is
provided.
2.
All parking areas proposed to have greater than ten (10) spaces must be de
signed by a licensed professional engineer.
3.
The proposed development layout shall provide for safe access and egress
from public and private roads by providing adequate location, numbers and
control of access points including sight distances, turning lanes, and traffic sig
nalization when required by existing and projected traffic flow on the municipal
and private road systems.
4.
The layout and design of all means of vehicular and pedestrian circulation, in
cluding walkways, interior drives, and parking areas shall provide for safe gen
eral interior circulation, separation of pedestrian and vehicular traffic, service
traffic, loading areas, and arrangement and use of parking areas. Areas used
by thru traffic shall not be considered as parking areas.
5.
In the design of parking areas, special attention shall be given to the separation
of pedestrian and vehicular traffic and the arrangement of parking areas that
are safe and convenient, and which have a minimum adverse affect on the de
sign, appearance, and environmental and aesthetic qualities of proposed build
ings and structures and neighboring properties.
6.
Where the development will abut an existing or potential parking area provi
sions shall be made for internal vehicular connections that allow vehicles to
move between parking areas/lots without having to enter the road.
7.
Required Off-Street Parking:
a.
Parking for Commercial Use shall, when ever possible, be located on the
same lot as the Commercial Use. The Planning Board may allow required
off-street parking to be met via a Designated Parking Facility as per
§20.D., Off-Site Parking Facilities. All parking mandated by the Americans
with Disabilities Act (ADA) must be on-site.
May 12, 2026
Section: 20 | 145
b.
Off-street parking for dwelling units must meet the standards set in §20.C.
and §20.D.
8.
The joint use of a parking facility by two or more principal buildings or uses may
be approved by the Planning Board where it is clearly demonstrated that said
parking facilities would substantially meet the intent of the requirements by rea
son of variation in the probable time of maximum use by patrons or employees
of such establishments.
B.
VEHICULAR ENTRANCE DESIGN STANDARDS
1.
Sight Distance and Access Management
a.
The required corner clearance is determined by the need to maintain ade
quate sight distance for vehicles approaching the intersection and the
need to prevent conflicts between turning traffic at the intersection and ve
hicles entering/exiting the new vehicular entrance.
b.
The measurement shall be taken from the point where the street's right-of-
way (ROW) lines intersect to the nearest edge of the proposed vehicular
entrance opening along the same street's ROW line.
2.
Minimum Corner Clearance Standards by Road Classification
a.
Resort Development District:
Intersecting Road Type
Adjacent Street
Classification
Minimum Corner
Clearance (Measured
from ROW Intersection)
Primary Road
Primary Road, Secondary
Road, or Neighborhood
Road
200 ft
Secondary Road
Secondary Road or
Neighborhood Road
75 ft
Neighborhood Road
Neighborhood Road
75 ft
b.
General, Rural and Protected Development Districts:
Intersecting Road Type
Adjacent Street
Classification
Minimum Corner
Clearance (Measured
from ROW Intersection)
146 | Unified Development Review Ordinance
Primary Road
Primary Road, Secondary
Road, or Neighborhood
Road
200 ft
Secondary Road
Secondary Road or
Neighborhood Road
150 ft
Neighborhood Road
Neighborhood Road
150 ft
3.
Alignment and Separation
Minimum Separation (Between Vehicular Entrances): Even if the corner
clearance is met, the distance from the new entrance to the nearest adjacent
vehicular entrance on the same side of the street shall be:
a.
75 feet for a Neighborhood or Secondary Road,
b.
and 200 feet for a Primary Road.
4.
Sight Distance Certification
a.
Required Sight Triangles: Regardless of the corner clearance distance,
the applicant must demonstrate that the proposed entrance location pro
vides adequate stopping sight distance (SSD) and intersection sight dis
tance (ISD) in both directions along the major road for all vehicles exiting
the parking facility.
b.
Safety Easement: The corner clearance area and any associated sight tri
angles must be kept free of obstructions between 3 feet and 8 feet above
the curbline/crown of the road, including vegetation, signs, or structures.
This area shall be covered by a perpetual non-access and sight visibility
easement.
5.
Number of Entrances (Access Consolidation):
For any commercial or multi-unit dwelling project, the number of Vehicular
Entrances onto a Primary or Secondary Road should be minimized and, ideally,
limited to one primary access point per street frontage, unless traffic volume or
site size dictates otherwise.
6.
Turn-Around Areas:
All drive ways and vehicular entrances shall be designed so that all
maneuvering and parking of any vehicle shall take place outside the right-of-
way of the road and such that vehicles may exit the premises without backing
onto the shoulder of the road. If a turnaround provision is not designed into a
parking area or other similar feature, then a turnaround shall be provided
May 12, 2026
Section: 20 | 147
measuring at last fifteen (15) feet wide and twenty five (25) feet long or equal to
the length of the design vehicle for the access way. This turn around may
designed as a hammerhead or a cul-de-sac.
7.
Construction Standards
Vehicular Entrances must meet the construction standards set in Section 18.C.
as follows:
Neighborhood
Road
Secondary Road
Low Volume Access
(Less than 99 vehicles/day)
X
Medium Volume Access
(Less than 400 vehicles/day)
X
High Volume Access
(Greater than 400 vehicles/day)
X
Large Vehicle Access1
(Large vehicles comprise 30% or higher of
daily traffic)
X
Notes:
1. Larger vehicle. A vehicle that has a larger length, width or turning radius and/or lesser
acceleration capability than standard passenger vehicles or small trucks. Larger vehicles
include busses, commercial trucks, and recreational vehicles.
C.
PARKING AREA DESIGN STANDARDS
1.
Access: There shall be adequate provisions for ingress and egress to all park
ing spaces. The width of vehicular entrances or driveways shall be determined
as part of site plan review depending on use, topography and similar consider
ations.
2.
Marking and delineation of parking areas: parking lots, vehicular entrances,
driveways and aisles shall be clearly marked and delineated. The Planning
Board may require that certain areas be maintained for firefighting or other
emergency purposes, handicapped access, and such areas shall be appropri
ately designated.
3.
Minimum parking requirements: Off-street parking spaces shall be provided to
conform with the number required in the following schedule:
148 | Unified Development Review Ordinance
Residential
Minimum # Parking Spaces Required1
Single detached or attached dwelling
1 per unit
Duplex (units up to 400 sq. ft.)
1 per unit
Duplex (units larger than 400 sq. ft.)
1 per unit
Multi-unit (units up to 400 sq. ft.)
1 per unit
Multi-unit (units larger than 400 sq. ft.)
1 per unit
Commercial
Minimum # Parking Spaces Required
Boarding House
1 per dwelling unit plus 1 per guest room
Bed and Breakfast
1 per dwelling unit plus 1 per guest room
Nightclubs, Restaurants, Theaters
1 space for every 3 seats or participants
plus 1 space for each person employed at
peak times2
Motels, Hotels, Lodging Facilities
1 space for every guest room plus 1 space
for each person employed at peak times
Retail Stores, Offices and Service
Establishments
1 space for every 300 sq. ft. of gross floor
area excluding storage; no less than 3
spaces
Wholesale Establishments
plus 1 space for each person employed at
peak times
Institutional/Public
Minimum # Parking Spaces Required
Assembly Halls, Outdoor Places of
Assembly or Public Recreation, Houses
of Worship
1 space for every 3 seats or participants
plus 1 space for each person employed at
peak times
NOTES TO THE MINIMUM PARKING SCHEDULE:
1. Developers may satisfy the residential parking minimums through an off-site
parking agreement with existing facilities located within 0.25 miles of the development
site. See §20.D. below..
2. For public restaurants operated in conjunction with a lodging facility, a percent
reduction in required parking spaces equal to the percent of restaurant patrons
attributable to "in-house" lodging guests may be granted. Such reduction shall not
exceed 50% of the total required for the restaurant. The burden of verification of the
percent of "in-house" patrons is with the applicant.
3. Where the calculation of the aforementioned parking spaces results in a fractional
part of a complete parking space, the parking spaces required shall be construed to be
the next highest number.
May 12, 2026
Section: 20 | 149
4. The above are minimum standards, additional or fewer parking spaces may be
required by the Planning Board.
4.
Off-street parking spaces shall comply with the following standards:
a.
Except as provided below, each parking space shall contain a rectangular
area at least eighteen (18) feet long and nine (9) feet wide. Lines demar
cating parking spaces may be drawn at various angles in relation to curbs
or aisles, so long as the parking spaces so created contain within them
the rectangular area required by this section.
b.
Up to twenty (20) percent of required parking spaces may contain a rec
tangular area of only eight (8) feet in width by fifteen (15) feet in length. If
such spaces are provided, they shall be conspicuously designated as re
served for small or compact cars only.
D.
OFF-SITE PARKING FACILITIES
1.
Authorization: The use of an Off-Site Parking Facility may be permitted to sat
isfy a development's parking requirements, provided all provisions of this sub
section are met.
2.
Location: The Off-Site Parking Facility must be an existing parking facility lo
cated within 0.25 miles (1,320 feet) of the development site that requires the
parking.
3.
Parking Agreement Required: A Parking Agreement must be executed and
recorded prior to the issuance of a building permit or certificate of occupancy
for the development site. The agreement must clearly stipulate the number of
spaces provided and ensure the availability of those spaces for the duration of
the use requiring the parking.
4.
Capacity Documentation: The developer shall provide the Planning Board or
Code Enforcement Officer with documentation demonstrating the availability of
sufficient capacity at the Off-Site Parking Facility. This documentation may in
clude a professional parking study, traffic analysis, or similar evidence accept
able to the Town of Newry.
5.
Review Standard: The Town shall not impose additional barriers to the approval
of a Parking Agreement beyond verifying the adequacy of the parking supply as
required by state law (Public Law 2025, Chapter 374).
6.
Conditions of Use:
150 | Unified Development Review Ordinance
a.
Pedestrian Access: A safe and clearly defined pedestrian walkway must
connect the development site and the Off-Site Parking Facility.
b.
Signage: Appropriate signage shall be installed to clearly designate the lo
cation of the Off-Site Parking Facility and the availability of parking for the
specific development.
May 12, 2026
Section: 20 | 151
SECTION 21: FIRST RESPONDER ACCESS AND FIRE LANES
SECTION USER'S GUIDE: This section contains specific standards relating to ac
cess for first responder vehicles such as firefighting apparatus and the construc
tion of fire lanes.
A.
APPLICABILITY
1.
Approved fire department access roads and fire lanes shall be provided for all
new commercial site plans, multi-unit dwelling subdivisions, and any subdivi
sion containing more than two lots, as required by this Ordinance and the Au
thority Having Jurisdiction (AHJ--the Newry Fire Chief or their designee). Ac
cess roads shall be provided and maintained in accordance with the specifica
tions below.
2.
Where conflicts occur between these and other standards of this Ordinance the
more restrictive shall apply.
B.
ACCESS PROXIMITY TO STRUCTURES:
1.
It extends to within fifty (50) feet of at least one exterior door that provides ac
cess to the interior of the building.
2.
Any portion of the facility or any portion of an exterior wall of the first story of
the building is located not more than one hundred fifty (150) feet from a fire de
partment access road, as measured by an approved route around the exterior
of the building.
3.
Sprinklered Exception: The distance in subsection B may be increased to two
hundred (200) feet for buildings protected throughout with an approved auto
matic sprinkler system.
C.
FIRE APPARATUS ACCESS ROAD SPECIFICATIONS:
Fire department access roads shall meet the following dimensional and structural require
ments:
1.
Unobstructed Width: A minimum unobstructed width of twenty (20) feet (6.1 m)
shall be maintained at all times.
2.
Unobstructed Vertical Clearance: A minimum unobstructed vertical clearance of
thirteen (13) feet, six (6) inches (4.1 m) shall be maintained.
3.
Load Capacity and Surface: Access roads shall be designed and maintained to
support the imposed live loads of the heaviest emergency fire apparatus and
shall be surfaced to provide all-weather driving capabilities. Unless otherwise
May 12, 2026
Section: 21 | 153
specified in this Section the Access Road, at a minimum, shall comply with
Neighborhood Road design and construction standards. Utility structures, cul
verts, bridges and any other structure utilized for access mus at a minimum
meet AASHTO HS-20 load rating. Documentation verifying structural capacity
shall be submitted for any road, bridge, or surface utilized for access.
4.
Turning Radius: The minimum inside turning radius of a fire department access
road shall be twenty-five (25) feet (7.6 m) to accommodate fire apparatus.
5.
Dead Ends and Turnarounds: Dead-end fire department access roads in ex
cess of one hundred fifty (150) feet (46 m) in length shall be provided with an
approved turnaround provision, such as a cul-de-sac or hammerhead, as ap
proved by the AHJ.
6.
Gradient and Approach: The road gradient shall not exceed ten (10) percent
unless otherwise approved by the AHJ, and the angle of approach and depar
ture shall not exceed the design limitations of the Newry fire apparatus.
D.
FIRE LANES, MARKING, AND OBSTRUCTION:
1.
Fire Lane Designation: Where required by the AHJ, fire department access
roads shall be designated as "Fire Lanes."
2.
Marking and Signage: Designated fire lanes shall be clearly marked with ap
proved signs and/or pavement markings that include the words "NO PARKING
--FIRE LANE." Signage shall be maintained in a clean, legible, and visible con
dition at all times.
3.
Obstruction Prohibition: Fire lanes and all fire department access roads shall
be maintained free of all obstructions, including parked vehicles, fences, stor
age, dumpsters, or other impediments.
E.
SECURITY GATES AND LOCKED ACCESS:
1.
Gated Access: The installation of security gates or other barriers across a fire
department access road shall be approved by the AHJ.
2.
Emergency Operation: Where gates or secured doors are installed, an ap
proved device or system shall be provided to grant the Fire Department imme
diate access. This may include, but is not limited to, the installation of a se
cured access box (e.g., Knox Box) of an approved type and in an approved lo
cation, containing keys or other access devices. The emergency operation
system shall be maintained operational at all times.
154 | Unified Development Review Ordinance
F.
ADDRESS IDENTIFICATION:
New and existing buildings shall be provided with approved address identification that is
legible and placed in a position that is visible from the street or access road fronting the
property. Address identification characters shall comply with the Addressing Ordinance
for the Town.
May 12, 2026
Section: 21 | 155
SECTION 22: STORM DRAINAGE DESIGN AND CONSTRUCTION STAN
DARDS
SECTION USER'S GUIDE: This section contains specific standards relating to the
design and construction of storm water management systems.
A.
GENERAL PROVISIONS
1.
The storm drainage system will not adversely affect neighboring properties,
downstream water quality, or cause soil erosion. Whenever possible, on-site
absorption of run-off waters shall be utilized to minimize discharges from the
site.
2.
Surface water run-off shall be minimized and detained on-site if possible or
practicable. If it is not possible to detain water on site, downstream improve
ments to the channel may be required of the developer to prevent flooding
caused by his project. The natural state of watercourses, swales, floodways or
rights-of-way shall be maintained as nearly as possible.
3.
The design basis is a twenty-five (25) year storm.
B.
STORM WATER MANAGEMENT DESIGN STANDARDS
1.
Adequate provision shall be made for disposal of all storm water generated
within the development and any drained ground water through a management
system of swales, culverts, underdrain, and water courses. The storm water
management system shall be designed to conduct storm water flows to existing
watercourses.
2.
All components of the storm water management system shall be designed to
meet the criteria of a twenty-five (25) year storm based on rainfall data for the
closest reporting station to Newry, Maine and comply with the standards con
tained in §18.H
3.
The minimum pipe size for any storm drainage pipe shall be fifteen (15) inches.
Maximum trench width at the pipe crown shall be the outside diameter of the
pipe plus two (2) feet. Installation shall conform to the specification set forth in
the current Standard Specification Highway and Bridges, State of Maine, De
partment of Transportation.
4.
Catch basins shall be installed where necessary and located at the curb line.
5.
Inlets and outlets shall be stabilized against soil erosion by stone riprap or
other suitable materials to reduce storm water velocity.
May 12, 2026
Section: 22 | 157
C.
STORM DRAINAGE CONSTRUCTION STANDARDS
1.
Reinforced concrete pipe:
Reinforced concrete pipe shall conform to the requirements of MaineDOT
Standard Specifications §706.02, Reinforced Concrete Pipe. Pipe shall meet
the requirements of AASHTO M 170 [ASTM C76].
2.
Corrugated metal pipe:
Corrugated metal pipe and special fittings shall conform to MaineDOT
Standard Specifications §707, Metallic Pipe. Steel pipe shall conform to
Subsection 707.02 and Aluminum pipe to Subsection 707.07. Pipe thickness
and coating shall be as specified on the plans, and the installed pipe shall not
exceed a deflection of five (5) percent.
3.
PVC Pipe:
PVC pipe shall conform to the requirements of MaineDOT Standard
Specifications Subsection 706.15, PVC Plastic Drain Pipe System, or
Subsection 706.10 for Corrugated PVC, as specified.
4.
Corrugated plastic pipe:
Corrugated polyethylene pipe (CPP) shall conform to MaineDOT Standard
Specifications Subsection 706.06. Installation and construction shall meet the
requirements of §603, Pipe Culverts and Storm Drains.
5.
Manholes and catch basins:
Manholes and catch basins shall be constructed in accordance with MaineDOT
Standard Specifications §604. Precast concrete sections shall conform to
Subsection 712.06, and concrete masonry units (blocks) shall conform to
Subsection 704.03.
6.
Metal frames and traps:
Frames, grates, and covers for manholes and catch basins shall conform to the
requirements of MaineDOT Standard Specifications Subsection 712.06 (for
cast iron) or 712.07 (for aluminum).
7.
Drain inlet alignment:
Drain inlet alignment shall be straight in both horizontal and vertical alignment
unless specific approval of a curvilinear drain is obtained in writing from the
Board.
8.
Manhole placement:
158 | Unified Development Review Ordinance
Manholes shall be provided at all changes in vertical or horizontal alignment
and at all junctions. On straight runs, manholes shall be placed at a maximum
of four hundred (400) foot intervals.
9.
Catch basin, culvert and manhole maintenance:
Upon completion each catch basin, culvert, and manhole shall be cleaned of all
accumulation of silt, debris or foreign matter and shall be kept clean until final
acceptance of the road by the Town.
May 12, 2026
Section: 22 | 159
SECTION 23: BORROW PITS
SECTION USER'S GUIDE: This section provides regulations for "borrow pits"--
excavations for sand, fill, or gravel that are moved off-site. See §27 for standards
related to mineral extraction or exploration.
A.
APPLICABILITY
This Ordinance applies to all borrow pits less than five (5) acres in size in the Town of
Newry. Any pit less than one (1) acre in size needs only a permit by the Code Enforce
ment Officer. Any pit of between one (1) and of less than five (5) acres shall require a
permit issued by the Planning Board. In issuing a permit for a borrow permit the Code
Enforcement Officer or the Planning Board shall find the requirement in Sections B and C
below will be met. When a pit is reviewed by the Planning Board Site Plan Review ap
proval in accordance with this section is required. For pits of five or more acres will re
quire a permit issued by the Maine Department of Environmental Protection. The applica
tion and permit shall be filed with the Code Enforcement Officer. This includes gravel,
sand, clay and pits used in the removal of other minerals.
B.
GENERAL RESTRICTIONS
1.
No borrow pit shall be excavated to a depth of any less than two (2) feet above
the normal high water level of an identified aquifer.
2.
No borrow pit shall have bank slopes of greater than 2 horizontal to 1 vertical.
3.
No borrow pit shall be overhanging sod, earth or material which could present a
dangerous condition.
4.
No borrow pit shall be located closer to the nearest property line from the top of
the 2 to 1 slope than twenty-five (25) feet for a pit less than one (1) acre; fifty
(50) feet for pits of one (1) to five (5) acres.
5.
No borrow pit shall be closer than sixty (60) feet to a public road or be exca
vated to a depth that may cause an unsafe condition with respect to the
roadbed or utilities located within the right-of-way.
6.
No borrow pit shall be located closer than one-hundred (100) feet from existing
or an approved disposal system.
C.
GENERAL STANDARDS
1.
All borrow pits covered by this Ordinance shall have a visual buffer located be
tween the pit and any public road.
May 12, 2026
Section: 23 | 161
2.
When conducting mineral exploration activities and creating and maintaining
access ways, provisions shall be made to effectively stabilize all areas of dis
turbed soil of the borrow pit to avoid erosion and sedimentation of surface wa
ters. These measures shall include seeding, mulching and fertilizing to insure
effective stabilization.
3.
All borrow pits excavated below road level shall have a safety berm con
structed between the pit and any public or private road. This shall be of suffi
cient height and thickness to prevent vehicles from accidentally entering the pit.
4.
All borrow pits between one (1) and five (5) acres shall be regraded, mulched and seeded within ninety
(90) days from the date that the pit is determined by the Code Enforcement Officer to be played out.
162 | Unified Development Review Ordinance
SECTION 24: HOME OCCUPATIONS
SECTION USER'S GUIDE: This section establishes performance standards for
home-based businesses to ensure they remain compatible with residential neigh
borhoods.
Home Occupations which do not meet the criteria contained in Section 1.E.5 shall obtain
a permit from the Planning Board and comply with the following conditions:
A. The business must be incidental and secondary to the primary residential use of
the premises;
B. At least one member of the residential household must own the business and be
actively involved in the business and have control over the business activities.
There will be not more than two full or part-time employees working on the
premises, other than immediate family members residing on the premises;
C. The appearance of the structure or accessory structure may not be altered, except
as provided under subsection D below and the occupation within the residence
must be conducted in a manner that would not cause the residence to differ from
its residential character by means of colors, lights or sounds;
D. Additions to the residence or accessory structure for the express purpose of a
home occupation shall be constructed and finished in the same manner as the
original structure such that the character and appearance of the principal structure
is maintained.
E. Retail sales shall be limited to the sale of products or goods produced, fabricated
or substantially altered on the premises as a result of the home occupation. This
may include products that are not manufactured on the premises as defined
above, but which are customarily incidental to the product created by the home oc
cupation.
F. There is adequate off-street parking on the premises for customer or client use.
G. There is no objectionable increase in vehicle traffic over that traffic normal for the
neighborhood.
H. It does not adversely affect any natural resource or environmentally sensitive area
including, but not limited to, a wetland, aquifer, watercourse, or water body.
I.
The home occupation shall not generate any nuisance, waste discharge, offensive
noise, vibration, smoke, dust, odors, heat, glare, radiation, fumes, or electrical in
terference detectable to the normal senses or which interferes with normal radio or
television reception, or causes other nuisances which extend beyond the limits of
May 12, 2026
Section: 24 | 163
the subject property. All waste material from the home occupation shall be re
moved promptly from the premises, according to state laws and local ordinances.
164 | Unified Development Review Ordinance
SECTION 25: LIFE SAFETY AND FIRE SUPPRESSION
SECTION USER'S GUIDE: This section contains specific standards relating to the
design, construction and operations of Life Safety and Fire Suppression systems
and / or required improvements.
A.
FIRE PROTECTION OPTIONS
All subdivisions (major or minor) created or amended on or after the effective date of this
performance standard shall implement one of the following options to provide fire protec
tion within the subdivision.
1.
Install within each dwelling unit as defined by this ordinance the appropriate
NFPA 13 sprinkler system.
2.
Install or provide proof of deeded access to a 60,000 gallon water storage facil
ity with appropriate hydrant constructed as outlined in subsections D, E, and F
below.
B.
DOCUMENTATION OF APPROVED FIRE PROTECTION OPTION
Approved option, ownership and maintenance responsibility shall be depicted in detail on
the Final Plan.
C.
SPRINKLER SYSTEMS
A fire sprinkler permit shall be obtained from the State Fire Marshall's Office. A copy of
which, when obtained, shall be submitted to the Code Enforcement Officer.
D.
LOCATION OF WATER STORAGE FACILITIES:
The location of water storage facilities for fire fighting shall not exceed the following:
1.
Not more than 1,500 linear road feet and 300 feet vertically measured from hy
drant head to the mid point of the lot's road frontage on which lot the dwelling is
located.
2.
Roads used to determine the distances in SECTION 25:D.1 above must meet
the standards of §19 of this Ordinance.
E.
WATER STORAGE FACILITIES
The purpose of water storage facilities for fire fighting shall be to meet a water supply re
quirement of five hundred (500) gallons per minute for the duration of two (2) hours. Wa
ter delivery may be through either dry or wet hydrants.
Water storage facilities:
May 12, 2026
Section: 25 | 165
1.
Must have a minimum working capacity of 60,000 gallons of water.
2.
Must be engineered and certified compliant with requirements set forth in NFPA
22: Standard for Water Tanks for Private Fire Protection. Proof of engineering
or tank compliance with these applicable standards are required to be submit
ted as part of the Final Plan.
3.
That were originally designed for purposes other than firefighting water sup
plies will not be accepted as an approved below-grade water supply.
4.
Shall be equipped with a visual gauge above ground to clearly display the tank
water level.
5.
Shall be protected and maintained by owner, from disturbance of frost and
other natural soil actions.
6.
Shall be graded smooth with a maintained surface, by owner, to be free of
trees, shrubs, brush and grass fourteen (14) inches or higher.
7.
Shall be inspected at least monthly by the owner or designated representative.
A written record of such inspections and all maintenance performed must be
kept and provide to the Code Enforcement Officer upon request.
8.
Shall be kept filled to designed capacity by the owner. It is the owner's respon
sibility to notify the Town immediately upon the discovery if designed capacity
can not be maintained.
9.
Shall provide a deeded right of way or easement to the Town to allow the in
spection, testing, training and emergency use in perpetuity.
F.
HYDRANTS
The applicant and the Code Enforcement Officer shall be in agreement of final hydrant
placement before any hydrants are installed. All hydrants and their access, placement,
associated piping and materials are to be installed as follows:
1.
All hydrants must be maintained by owner and accessible for use at all times
throughout the entire year. Snow will be removed from around any hydrant, so
that fire equipment can maneuver next to and around the hydrant area
166 | Unified Development Review Ordinance
2.
Access and location of hydrants shall comply with figure 23-1. and hydrant pad
area shall be no greater than two (2) percent slope.
3.
In cases where the hydrant cannot be located in compliance with §23.D.2. an
access road built to standards for a Neighborhood Road as specified in §18,
Road Design and Construction Standards, shall be constructed accessing the
hydrant. The owner will be responsible for maintaining the access road to the
hydrant and around the hydrant itself. The hydrant pad area shall be no
greater than two (2) percent slope. The access road shall be posted as No
Parking Fire Lane.
4.
A deeded right of way or easement shall be given to the Town of Newry to allow
the inspection, testing and emergency use of all water storage facilities and hy
drants in perpetuity.
5.
Fencing is optional, however if a fence is provided it shall be maintained by
owner and have a gated access point and a lock box shall be installed holding
keys for the gate. Keys for the lock box shall be provided to the Newry Fire De
partment. The hydrant may be located outside the fence.
6.
All hydrants shall be primed and then painted with red fluorescent paint and
protected by a minimum of two, four (4) inch steel bollards placed parallel in
line to the pull up parking area three (3) feet on each side of hydrant. Bollards
shall be primed and then painted with red fluorescent paint and white reflective
tape affixed to the upper (3) inches of bollard.
May 12, 2026
Section: 25 | 167
7.
All Hydrants shall be installed and maintained by owner, to not have any trees,
shrubs, brush or grass fourteen (14) inches or higher within ten (10) feet in
front of hydrant and within 5 feet in back of hydrant.
8.
Dry hydrants are defined as a non pressurized water pipe installed in a water
source where water is obtained by suction through a fire trucks onboard pump.
Dry hydrants shall be installed in accordance with the following standards.
a.
The maximum amount of lift permitted for a dry hydrant shall be fifteen
(15) feet, as measured from the surface of the water to the center of the
hydrant hose connection.
b.
A suction screen shall be formed in the end of the steel or PVC pipe so as
not to impede or restrict any water flow by volume. The suction screen
shall be raised off the bottom of any fire pond twenty-four (24) inches, and
be twenty-four (24) inches away from any of the sides of the pond.
c.
A minimum of six (6) inch schedule (40) steel or PVC piping and fittings
shall be utilized from the suction screen to one (1) ninety (90) degree el
bow or two (2) forty five (45) degree elbows raising the hydrant above the
graded surface.
d.
The piping from the suction screen to the ninety (90) degree elbow for the
riser below ground shall be schedule forty (40) steel or PVC pipe with a
distance of no more than 50 feet.
e.
The riser piping and ninety (90) degree elbows shall be schedule forty
(40) steel or PVC.
f.
The riser piping shall be expose above grade level thirty-six (36) inches as
measured from the center of the hydrant opening to the grade level of the
fire equipment's parking location.
g.
The ninety (90) degree elbow below ground shall have six (6) feet of cover
measured from elbow to finished grade.
h.
The hydrant hose connection shall be aluminum or bronze with six (6)
inch National Standard Thread (NST). Additional piping and fittings shall
be a minimum of schedule forty (40) steel or PVC.
i.
All pipe connections shall be cleaned and welded so as to provide airtight
connections.
9.
Wet hydrants are defined as hydrants, which under normal conditions have a
positive water pressure.
168 | Unified Development Review Ordinance
a.
All Pressure Hydrants shall be NFPA Standard 24.
b.
Static Pressure at the hydrant shall be greater than zero (0) pounds per
square inch and less than one hundred and fifty (150) pounds per square
inch.
c.
Wet hydrants shall be placed not more than four (4) feet from the edge of
the road shoulders.
G.
FIRE PONDS
All fire ponds that were placed in service prior to the adoption of this standard are
deemed to be nonconforming structures and are subject to §11.I., Nonconforming Struc
tures, Uses and Lots. In addition, these fire ponds:
1.
Shall be maintained by their owner to not have any trees, shrubs, brush or
grass fourteen (14) inches or higher with ten (10) feet of the high water mark.
2.
Shall be dredged, by its owner, if it becomes affected by vegetation and or silt
as determined by the Code Enforcement Officer.
3.
Shall maintain all installed hydrants so as to meet the standards for hydrants in
this Performance Standard.
May 12, 2026
Section: 25 | 169
SECTION 26: COMMERCIAL WIND ENERGY FACILITIES
SECTION USER'S GUIDE: This section provides comprehensive standards for the
siting, design, operation, and decommissioning of commercial wind energy facili
ties.
In addition to other the standards contained in this Ordinance Commercial Wind Energy
Facilities shall comply with the following. Where conflicts occur between these and other
standards of this Ordinance the more restrictive shall apply.
A.
DESIGN SAFETY CERTIFICATION
Each Wind Turbine shall be certified that it conforms to all applicable industry standards
including those of the American National Standards Institute (ANSI) and at least one of
the following: Underwriters Laboratories, Det Norske Veritas, Germanischer Llloyd Wind
Energies, or other similar certifying organization.
B.
STRUCTURE TYPE
With the exception of Meteorological (MET) Towers, towers shall be monopoles with no
guy wires.
C.
BLADE CLEARANCE
The minimum distance between the ground and all blades of a Wind Turbine shall be 25
feet as measured at the lowest arc of the blades.
D.
SIGNAL INTERFERENCE
The Wind Energy Facility shall not produce electromagnetic interference with radio, televi
sion, cellular service or internet reception.
E.
OVERSPEED CONTROLS AND BRAKES
Each Wind Turbine shall be equipped with an overspeed control system that includes
both an aerodynamic control such as stall regulation, variable blade pitch, or other similar
system, and a mechanical brake that operates in fail safe mode certified by the manufac
turer.
F.
VOLTAGE WARNINGS
A clearly visible warning sign that conform to applicable ANSI and OSHA standards con
cerning voltage must be placed at the base of all pad-mounted transformers and substa
tions.
May 12, 2026
Section: 26 | 171
G.
VISUAL APPEARANCE
1.
A Wind Turbine shall have a non-obtrusive color such as white, off-white or
gray, with a matte finish, or as may otherwise be required by another govern
mental agency with jurisdiction over the Wind Energy Facility.
2.
A Wind Turbine shall not be lighted artificially, except to the extent consistent
with Federal Aviation Administration recommendations or other applicable au
thority that regulates air safety or as is otherwise required by another govern
mental agency with jurisdiction over the Wind Energy Facility.
3.
A Wind Turbine shall not be used to support signs and shall not display adver
tising except for reasonable and incidental identification of the turbine manufac
turer, facility owner and operator, and for warnings.
H.
SHADOW FLICKER AND BLADE REFLECTION
Shadow flicker and blade refection shall not result in the following:
1.
More than 30 hours of flicker per year on any non-participating occupied build
ing regardless in which municipality it may be located.
2.
More than 10 hours of flicker per year on any public or private road that inter
feres with traffic movement safety.
3.
Flicker at intersections of any public and/or private roads that interferes with
traffic safety.
I.
USE OF PUBLIC ROADS
1.
The Applicant shall identify all municipal maintained public roads to be used, to
transport earthen materials, equipment and parts for construction, operation or
maintenance of a Wind Energy Facility.
2.
The Town Engineer or a qualified third-party engineer retained by the Planning
Board and paid for by the Applicant shall document road and bridge conditions
prior to construction. The Town Engineer or third-party engineer shall docu
ment road and bridge conditions again thirty (30) days after construction is
complete or as weather permits and provide an assessment to the Planning
Board of damage to roads and bridges attributable to the Wind Energy Facility
construction.
3.
The Applicant shall demonstrate, to the satisfaction of the Planning Board, that
it has financial resources sufficient to comply with subsection d, below, and the
Planning Board shall require the Applicant to post a bond or other security in
order to ensure such compliance.
172 | Unified Development Review Ordinance
4.
Road and/or bridge damage determined to have been caused by the Applicant
or its contractors shall be repaired to the satisfaction of the Town Engineer or
third-party engineer at the Applicant's expense in the time period specified by
the Town Engineer or third-party engineer.
J.
SAFETY SETBACKS
Wind Turbines shall be set back, at a minimum, a horizontal distance equivalent to 150%
of the Turbine Height from property boundaries, public and private rights-of-way and over
head utility lines that are not part of the proposed Generating Facility, regardless of the
municipality in which located, except that the Planning Board may allow a reduced set
back if the Applicant submits, in writing a legally binding waiver of the property boundary
setback signed by the pertinent abutting landowner.
K.
LOCAL EMERGENCY SERVICES
1.
The Applicant shall provide a copy of the project summary and site plan to local
emergency service providers, including paid or volunteer fire department(s).
2.
Upon request, the Applicant shall cooperate with emergency service providers
to develop and coordinate implementation of an emergency response plan.
3.
A Wind Turbine shall be equipped with an appropriate fire suppression system
to address fires within the Nacelle portion of the turbine or shall otherwise ad
dress the issue of fire safety to the satisfaction of the Planning Board.
L.
INSURANCE
The Applicant, Owner/operator and Licensee, as applicable, shall maintain a current ap
propriate insurance policy for the Wind Energy Facility that covers bodily injury and prop
erty damage in an amount commensurate with the scope and scale of the Wind Energy
Facility, and acceptable to the Planning Board, which acceptance shall not be unreason
ably withheld. Certificates of insurance shall be provided to the Town annually.
The policy must include the requirement that the Town will be provided at least ten days
notice by the policy provider in the case of cancellation or change to the policy.
M.
PUBLIC INQUIRIES AND COMPLAINTS
1.
The Applicant or its designee shall maintain a phone number and identify a re
sponsible person for the public to contact with inquiries and complaints
throughout the life of the Wind Energy Facility.
2.
The Applicant or its designee shall provide the Code Enforcement Officer with a
written notice that a complaint has been received within 10 days of its receipt.
Then within 20 days of the date that the applicant or its designee received the
May 12, 2026
Section: 26 | 173
complaint the applicant or its designee shall provide the Code Enforcement Of
ficer with written notice of how the complaint was responded to.
N.
DECOMMISSIONING
The Wind Energy Facility shall be decommissioned within twelve months after it ceases
to generate electricity, or after any permit has been revoked.
1.
Decommissioning shall include removal and disposal off-site of all parts of the
Wind Energy Facility (including foundations) in accordance with local, state and
federal laws and regulations. Areas of disturbed earth shall be graded, re
seeded, or otherwise re-vegetated, unless the landowner of the affected land
requests otherwise in writing.
2.
A Licensed Professional Engineer shall be retained by the Planning Board and
paid for by the Applicant to estimate the total cost of decommissioning and
itemization of the estimated major expenses, including the projected costs of
measures taken to minimize or prevent adverse effects on the environment
during implementation of the decommissioning plan. The itemization of major
costs may include, but is not limited to, the cost of the following activities: tur
bine removal, turbine foundation removal and permanent stabilization, building
removal and permanent stabilization, transmission corridor removal and perma
nent stabilization and road infrastructure removal and permanent stabilization
3.
No permit for a Wind Energy Facility shall be issued until Decommissioning
Funds have been posted by the Applicant with a bonding company or a Federal
or State-chartered lending institution (the Escrow Agent) authorized to conduct
such business in the State of Maine and approved by the Select Board; pro
vided, however that if the Applicant posts a guarantee for Decommissioning
Funds with the State of Maine under an order by the Maine Department of En
vironmental Protection, then the Applicant shall not also provide Decommis
sioning Funds to the Town under this provision.
4.
Every five (5) years subsequent to approval, the Wind Energy Facility Owner/
Operator shall provide a current estimate of decommissioning costs to the Se
lect Board on or by the date of the anniversary of the granting of a Wind Energy
Facility Permit. Upon the Select Board's acceptance of the revised estimates,
the Owner/Operator of the Wind Energy Facility shall adjust and maintain De
commissioning Funds that are at least equal to the most recent Town accepted
estimate
5.
Decommissioning funds may be in the form of a performance bond, surety
bond or other form of financial assurance acceptable to the Select Board.
174 | Unified Development Review Ordinance
6.
If the Owner/Operator of the Wind Energy Facility does not complete decom
missioning within the prescribed time period the Town may take such action as
necessary (including court action, with all legal costs to be paid by applicant) to
secure the posted Decommissioning Funds and to ensure completion of the
decommissioning.
7.
The Escrow Agent shall not release the Decommissioning Funds except upon
written approval of the Select Board.
May 12, 2026
Section: 26 | 175
SECTION 27: MINERAL EXPLORATION OR EXTRACTION
SECTION USER'S GUIDE: This section applies to commercial mining and mineral
extraction operations, establishing standards for operation, environmental protec
tion, and site reclamation.
This section applies to all mining operations that do not meet the definition of a borrow pit
and are being performed for commercial gain, or to extract materials being used off-site.
Where mining takes place in Shoreland zoning districts, the provisions of the Shoreland
Zoning Ordinance apply and the more restrictive of the two shall govern. Mineral extrac
tion sites one-quarter (¼) of an acre in size to one (1) acre in size require a permit from
the Code Enforcement Officer. Any operation with an aggregate area of greater than one
(1) acre in size shall require a permit issued by the Planning Board. In issuing a permit
for a mining operation the Code Enforcement Officer or the Planning Board shall find the
requirement in Sections 1 though 3 below will be met. When an operation is reviewed by
the Planning Board Site Plan Review approval in accordance with this ordinance is re
quired.
A.
GENERAL RESTRICTIONS
1.
No operations shall be excavated to a depth of any less than two (2) feet above
the normal high water level of an identified aquifer.
2.
No part of any extraction operation, including drainage and runoff control fea
tures, shall be permitted within seventy-five (75) feet, horizontal distance, of the
normal high-water line of any water body, tributary stream, or wetland.
3.
Extraction operations shall not be permitted within one-hundred (100) feet, hori
zontal distance, of any property line without written permission of the owner of
such adjacent property.
4.
No mining activities will take place on sustained slopes steeper than 20% and
sustained for an aggregate area of 10,890 square feet, unless the area is to be
removed and regraded such that the slopes are made less steep.
5.
Extraction techniques that involve open ponds or fields with salt, chemicals or
other solutions that harm the ability of on-site native soils to support healthy
and diverse plant life, and could be harmful to invertebrates and fish in nearby
waters, are prohibited.
B.
GENERAL STANDARDS
1.
Hours of Operation. The hours of operation for activities that generate noise,
light, fumes, dust may be restricted by the Planning Board.
May 12, 2026
Section: 27 | 177
2.
Lighting. All exterior lights shall use hoods and lenses that cast light down
ward.
3.
Vibration and Blasting. Operations shall comply with all local, state, and fed
eral law, rule or regulation pertaining to blasting activities. Upon request by the
town, the operator shall provide access to blasting logs. Blasting may occur
Monday through Friday from 7 a.m. to 5 p.m. Blasting is not allowed on Satur
days, Sundays, and Federal Holidays.
a.
Log Details. An accurate blasting log shall be prepared and maintained
for each blast fired. East blasting log shall include, but not be restricted to
the following information: time and date of blast, diagram of blast hole lay
out, number and dimensions of blast hole, pounds of explosives used, dis
tance to closest habitable structure.
b.
Blasting shall be conducted in a manner designed to prevent injury to per
sons or damage to property.
4.
In keeping with the purposes of this Ordinance, the Planning Board may im
pose such conditions as are necessary to minimize the adverse impacts asso
ciated with mineral extraction operations on surrounding uses and resources.
5.
Where an access road joins a public or private road a stabilized construction
entrance shall be installed and maintained to ensure that mud is not tracked
onto roadways, in conformance with the MDEP's "Maine Erosion Control and
Sediment Control Practices Field Guide for Contractors," 2014 or more current
version.
6.
Access road design for a stabilized construction or a permanent entrance in
volves a pad of aggregate underlain with filter cloth located at any point where
traffic will enter a public roadway. Figure 25-1 details the construction standard
for the Town of Newry. Inspections shall be made daily to ensure that mud and
dirt are not tracked into the public roadway; top dressing may be required espe
cially if the subgrade is soft or becomes saturated; daily cleaning of the public
roadway of any residual mud and dirt. Do not wash excess mud and dirt into
the storm water road drainage swales or nearby streams and rivers.
178 | Unified Development Review Ordinance
C.
ADDITIONAL SUBMITTALS FOR SITE PLAN REVIEW
1.
A reclamation plan shall be filed with the Town. The plan shall include but not
be limited to the following:
a.
All reclaimed slopes must be structurally stable and harmonious with the
surrounding environment. Techniques shall be utilized to prevent sliding,
slumping and heaving, and slopes steeper than 3:1 (horizontal:vertical)
will have engineered solutions, or be avoided.
b.
Temporary erosion control methods shall be utilized and an erosion con
trol plan provided showing what methods will be used, and specifications
for methods and materials including seed mixes.
c.
Reclamation plan shall include a planting design and any topsoil or other
additives required on site in order to grow vigorous vegetation.
d.
Planting shall result in evenly distributed vegetation such that 90% of the
reclaimed area is covered with vigorous growth within 18 months of seed
ing and planting.
e.
All structures, roads, staging areas and unvegetated surfaces that were
part of the mining operations shall be removed, unless they are required
for post-closure maintenance or care, as approved by the town.
May 12, 2026
Section: 27 | 179
f.
Soil which is stripped or removed must be stockpiled for use in reclaiming
disturbed land areas unless the permittee demonstrates to the satisfaction
of the Code Enforcement Officer that the soil is not needed for reclama
tion purposes. Stockpiled soils shall be seeded, mulched, and anchored
or otherwise stabilized.
2.
A cost estimate from a licensed engineer shall be provided for the cost of the
reclamation plan. This estimate shall be used by the Select Board to determine
the amount of a reclamation bond, that shall be not less than 100% of esti
mated costs, and that shall be held by the Town.
3.
Exterior lighting design and fixture specifications.
4.
Erosion Control and Stormwater. A plan showing how changes to the runoff on
site (runoff direction, speed and volume) will be handled to ensure that dis
charges from the site are similar to pre-construction runoff. Temporary erosion
control methods shall be employed on site to reduce soil transport.
5.
Existing conditions photos documenting any existing features including tailings
or debris.
D.
RECLAMATION BOND UPDATE
A cost estimate for the reclamation plan for open areas shall be updated every five years
and provided to the Select Board who may require increases to the reclamation bond.
180 | Unified Development Review Ordinance
SECTION 28: WIRELESS TELECOMMUNICATIONS FACILITIES
SECTION USER'S GUIDE: This section provides the standards and review
process for the construction and expansion of wireless telecommunications facili
ties (cell towers).
A.
PURPOSE
To provide a process and a set of standards for the construction of Wireless Telecommu
nication Facilities in order to:
1.
Preserve the character and appearance of the Town of Newry while allowing
adequate development of wireless telecommunications services.
2.
Implement a municipal policy concerning the provision of wireless telecommu
nications services, and the siting of their Facilities;
3.
Establish clear guidelines, standards and time frames for the exercise of mu
nicipal authority to regulate Wireless Telecommunication Facilities;
4.
Allow competition in telecommunications service;
5.
Encourage the provision of advanced telecommunications services to the
largest number of businesses, institutions and residents of Newry;
6.
Permit and manage reasonable access to the public rights of way of Newry for
telecommunications purposes on a competitively neutral basis;
7.
Ensure that all telecommunications carriers providing Facilities or services
within Newry comply with the ordinances of Newry;
8.
Ensure that Newry can continue to fairly and responsibly protect the public
health, safety and welfare;
9.
Encourage the colocation of Wireless Telecommunication Facilities, thus help
ing to minimize adverse visual impacts on the community;
10.
Enable the Town to discharge its public trust consistent with rapidly evolving
federal and state regulatory policies, industry competition and technological de
velopment; Further the goals and policies of the comprehensive plan, while
promoting orderly development of the Town with minimal impacts on existing
uses; and
11.
Protect the scenic and visual character of the community.
May 12, 2026
Section: 28 | 181
B.
APPLICABILITY
This performance standard applies to all construction and expansion of wireless telecom
munication facilities, except as provided in SECTION 28:B.1.
1.
Exemptions
The following are exempt from the provisions of this sub-section:
a.
Emergency Wireless Telecommunications Facility. Temporary Wireless
Communication Facilities for emergency communications.
b.
Amateur Radio Service. Amateur (ham) radio stations licensed by the
Federal Communications Commission (FCC).
c.
General Mobile Radio Service (GMRS). GMRS stations licensed by the
Federal Communications Commission (FCC).
d.
Maintenance or repair. Maintenance, repair or reconstruction of a wire
less telecommunication facility and related equipment, provided that there
is no change in the height or any other dimension of the facility.
e.
Temporary Wireless Telecommunication Facility. Temporary Wireless
Telecommunication Facility, in operation for a maximum period of one
hundred eighty (180) days.
f.
Antennas as accessory uses. An antenna that is an accessory use to a
residential dwelling unit.
C.
REVIEW AND APPROVAL AUTHORITY
No person shall construct, make significant changes to, or expand a Wireless Telecom
munication Facility without approval of the Code Enforcement Officer (CEO) or the Plan
ning Board as follows:
1.
Expansion of or significant changes to an existing Wireless Telecommunica
tions Facility and colocation.
a.
Approval by the CEO is required for any of the following actions, provided
the overall height of the Wireless Telecommunications Facility does not in
crease beyond the maximum heights set out elsewhere in this perfor
mance standard:
i.
Replacement of antennas with different kinds of antennas or relocat
ing antennas to a new location on the Wireless Telecommunication
Facility;
182 | Unified Development Review Ordinance
ii.
Accessory use of an existing Wireless Telecommunication Facility; or
iii.
Colocation on an existing Wireless Telecommunication Facility.
b.
Approval of the Planning Board is required for any increases in the Wire
less Telecommunications Facility height.
2.
New Construction
Approval of the Planning Board is required for construction of a new Wireless
Telecommunication Facility, and any expansion of an existing Wireless
Telecommunication Facility that increases the height of the Wireless
Telecommunications Facility.
3.
Approval Authority
The CEO or Planning Board as appropriate shall review applications for
Wireless Telecommunication Facilities, and shall approve, approve with
conditions, or deny such applications and make written findings on whether the
proposed Wireless Telecommunications Facility complies with this Ordinance.
D.
APPLICATION PROCEDURES
All persons seeking approval of the CEO or the Planning Board under this performance
standard shall submit an application as detailed in §10 of this ordinance.
E.
STANDARD OF REVIEW
To obtain approval from the CEO or the Planning Board, an application must comply with
the standards in this section.
1.
CEO Approval Standards
a.
The proposed Wireless Telecommunications Facility is an expansion, sig
nificant change, accessory use, or colocation to a structure existing at the
time the application is submitted.
b.
The applicant has sufficient right, title, or interest to locate the proposed
Wireless Telecommunications Facility on the existing structure.
c.
The proposed Wireless Telecommunications Facility will be constructed
with materials and colors that match or blend with the surrounding natural
or built environment, to the maximum extent practicable.
d.
The proposed Wireless Telecommunications Facility, to the maximum ex
tent practicable, shall have no unreasonable adverse impact upon dis
tricts, historic landmarks, sites, buildings, structures or objects, significant
May 12, 2026
Section: 28 | 183
in American history, architecture, archaeology, engineering or culture, that
are listed, or eligible for listing, in the National Register of Historic Places
(see 16 U.S.C. 470w(5); 36 CFR 60 and 800).
2.
Planning Board Approval Standards
a.
New Wireless Telecommunication Facilities must be located according to
the priorities below. The applicant shall demonstrate that a Wireless
Telecommunications Facility of a higher priority cannot reasonably accom
modate the applicant's proposed Facility.
i.
Colocation on an existing Wireless Telecommunication Facility or
other existing structure as allowed in §23.H. of this ordinance.
ii.
A new Wireless Telecommunications Facility on public or private
property as allowed in §23.H. of this ordinance.
b.
If an applicant proposes to locate a new Wireless Telecommunication Fa
cility, or expand an existing Facility on municipal property, the applicant
must show the following:
i.
The proposed location complies with applicable municipal ordi
nances.
ii.
The proposed Wireless Telecommunications Facility will not unrea
sonably interfere with the municipal purpose of the property.
iii.
The applicant has adequate liability insurance and a lease agree
ment with the municipality that includes reasonable compensation for
the use of the property and other provisions to safeguard the public
rights and interests in the property.
c.
A new Wireless Telecommunication Facility and related equipment must
be designed and constructed to accommodate expansion for future colo
cation of at least three additional Wireless Telecommunications Facilities
or providers. However, the Planning Board may waive or modify this stan
dard where the height limitation effectively prevents future colocation.
d.
A new Wireless Telecommunication Facility shall not exceed a height of
one hundred twenty-five (125) feet above ground level, except that where
evidence of technical effectiveness as a Wireless Telecommunications Fa
cility, acceptable design, and collocation is provided, the Planning Board
may approve an additional twenty-five (25) feet of tower height per each
additional wireless communication service provider, not to exceed a maxi
mum tower height of one hundred and fifty (150) feet.
184 | Unified Development Review Ordinance
e.
A new or expanded Wireless Telecommunication Facility must comply with
the set back requirements for the Growth Management District in which it
is located, or be set back one hundred five percent (105%) of its height
from all property lines, whichever is greater, including the areas outside
the property boundaries if secured by an easement which may satisfy the
setback. An antenna is exempt from the setback requirement if it extends
no more than five (5) feet horizontally from the edge of the structure to
which it is attached, and it does not encroach upon an abutting property.
f.
A new Wireless Telecommunication Facility and related equipment must
be screened with vegetation, such as shrubs and trees, from view by
abutting properties, to the maximum extent practicable. Existing vegeta
tion and natural land forms on the site shall also be preserved to the maxi
mum extent practicable.
g.
A new Wireless Telecommunication Facility must be fenced to discourage
trespass on the Facility and to discourage climbing on any structure by
trespassers.
h.
A new Wireless Telecommunication Facility must be illuminated only as
necessary to comply with FAA or other applicable state and federal re
quirements. However, security lighting may be used as long as it is
shielded to be down directional to retain light within the boundaries of the
site, to the maximum extent practicable.
i.
A new Wireless Telecommunication Facility must be constructed with ma
terials and colors that match or blend with the surrounding natural or built
environment, to the maximum extent practicable. Unless otherwise re
quired, muted colors, earth tones, and subdued hues shall be used.
j.
A new Wireless Telecommunication Facility must comply with the current
Electronic Industries Association/Telecommunications Industries Associa
tion (EIA/TIA) 222 Revision Standard entitled "Structural Standards for An
tenna Supporting Structures and Antennas and Small Wind Turbine Sup
port Structures. Monopole or self-supported structures are preferred over
structures with guy wires.
k.
The proposed Wireless Telecommunication Facility will have no unreason
able adverse impact upon Designated Scenic Resources within the Town,
as identified either in the Town's adopted comprehensive plan, or by a
State or federal agency. In determining the potential unreasonable ad
verse impact of the proposed Facility upon the Designated Scenic Re
sources, the Planning Board shall consider the following factors:
May 12, 2026
Section: 28 | 185
i.
the extent to which the proposed Wireless Telecommunication Facil
ity is visible above the tree line, from the Viewpoint(s) of the im
pacted Designated Scenic Resource;
ii.
the type, number, height, and proximity of existing structures and
features, and background features within the same Line of Sight as
the proposed Wireless Telecommunications Facility;
iii.
the extent to which the proposed Wireless Telecommunication Facil
ity would be visible from the Viewpoint(s);
iv.
the amount of vegetative screening;
v.
the distance of the proposed Wireless Telecommunications Facility
from the Viewpoint and the Wireless Telecommunications Facility's
location within the Designated Scenic Resource; and
vi.
the presence of reasonable alternatives that allow the Wireless
Telecommunications Facility to function consistently with its purpose.
l.
The proposed Wireless Telecommunications Facility, to the maximum de
gree practicable, will have no unreasonable adverse impact upon a His
toric District, site or structure that is currently listed on or eligible for listing
on the National Register of Historic Places.
F.
STANDARD CONDITIONS OF APPROVAL
The following standard conditions of approval shall be a part of any approval or condi
tional approval issued by the CEO or Planning Board. Where necessary to ensure that
an approved project meets the criteria of this ordinance, the Planning Board can impose
additional conditions of approval. Reference to the conditions of approval shall be clearly
noted on the final approved site plan, and shall include:
1.
The owner of the Wireless Telecommunication Facility and his or her succes
sors and assigns agree to:
a.
respond in a timely, comprehensive manner to a request for information
from a potential colocation applicant, in exchange for a reasonable fee not
in excess of the actual cost of preparing a response;
b.
negotiate in good faith for shared use of the Wireless Telecommunication
Facility by third parties;
c.
allow shared use of the Wireless Telecommunication Facility if an appli
cant agrees in writing to pay reasonable charges for colocation.
186 | Unified Development Review Ordinance
d.
allow shared use of the Wireless Telecommunication Facility with County
and municipal departments or agencies with no charge for colocation.
e.
require no more than a reasonable charge for shared use of the Wireless
Telecommunication Facility, based on community rates and generally ac
cepted accounting principles. This charge may include, but is not limited
to, a pro rata share of the cost of site selection, planning project adminis
tration, land costs, site design, construction and maintenance, financing,
return on equity, depreciation, and all of the costs of adapting the tower or
equipment to accommodate a shared user without causing electromag
netic interference. The amortization of the above costs by the Wireless
Telecommunications Facility owner shall be accomplished at a reasonable
rate, over the life span of the useful life of the Wireless Telecommunication
Facility.
2.
Upon request by the municipality, the applicant shall certify compliance with all
applicable FCC radio frequency emissions regulations.
3.
The applicant shall obtain a form of surety approved by the Select Board as set
forth in §10.C.2.j.xi. to pay for the cost of removal of the Wireless Telecommuni
cations Facility by the Town if the Wireless Telecommunications Facility is
abandoned or, in lieu of such surety bond, the Planning Board shall require the
deposit of sufficient funds in an escrow account in the name of the Town for the
Town to pay the cost of removal of an abandoned Wireless Telecommunica
tions Facility set forth in SECTION 28:G of this ordinance.
4.
During construction, repair, or replacement, operation of a back-up power gen
erator at any time during a power failure, and testing of a back-up generator
between 8 a.m. and 9 p.m. is exempt from existing municipal noise standards.
G.
ABANDONMENT
A Wireless Telecommunication Facility that is not operated for a continuous period of
twelve (12) months shall be considered abandoned. The CEO shall notify the owner of
an abandoned Wireless Telecommunications Facility in writing and order the removal of
the Facility within ninety (90) days of receipt of the written notice. The owner of the Wire
less Telecommunications Facility shall have thirty (30) days from the receipt of the notice
to demonstrate to the CEO that the Wireless Telecommunications Facility has not been
abandoned.
If the Owner fails to show that the Wireless Telecommunications Facility is in active oper
ation, the owner shall have sixty (60) days to remove the Wireless Telecommunications
Facility. If the Wireless Telecommunications Facility is not removed within this time pe
riod, the municipality may remove the Wireless Telecommunications Facility at the
May 12, 2026
Section: 28 | 187
owner's expense. The owner of the Wireless Telecommunications Facility shall pay all
site reclamation costs deemed necessary and reasonable to return the site to its pre-con
struction condition, including the removal of roads, and reestablishment of vegetation.
The owner of the Wireless Telecommunications Facility may apply to the Planning Board
for release of the surety or return of any unexpended portion of the required escrow ac
count as set forth in SECTION 28:F.3 when the Facility and related equipment are re
moved to the satisfaction of the Planning Board.
188 | Unified Development Review Ordinance
SECTION 29: SOLAR ENERGY SYSTEMS
SECTION USER'S GUIDE: This section establishes standards for the installation
and operation of solar energy systems, distinguishing between rooftop, small-
scale, and large-scale ground-mounted systems. Standards for the decommis
sioning of large-scale ground mounted systems are also specified..
A.
PURPOSE
The purpose of this ordinance is to establish a municipal review procedure and perfor
mance standards for Solar Energy Systems (SES). These standards are intended to:
1.
Establish clear guidelines, standards and time frames for the Town to regulate
Solar Energy Systems;
2.
Permit the Town to fairly and responsibly protect public health, safety and wel
fare;
3.
Minimize any potential adverse effect of solar development on surrounding land
use;
4.
Provide for the decommissioning/removal of panels and associated utility struc
tures that are no longer being used for energy generation and transmission
purposes; and
5.
Support the goals and policies of the Comprehensive Plan, including orderly
development, efficient use of infrastructure, and protection of natural, scenic,
and agricultural resources.
B.
APPLICABILITY
1.
Notwithstanding the provisions of 1 M.R.S.A section 302 or any other law to the
contrary, the requirements of this performance standard shall apply to all Roof-
Mounted and Ground-Mounted Solar Energy Systems modified or installed af
ter the date of its enactment.
2.
All Solar Energy Systems shall be designed, erected, and installed in accor
dance with all applicable codes, regulations and standards.
3.
Any upgrade, modification or structural change that materially alters the size,
placement or output of an existing Solar Energy System shall comply with the
provisions of this performance standard.
May 12, 2026
Section: 29 | 189
C.
REVIEW AND APPROVAL AUTHORITY
No person shall construct, make significant changes to, or expand a Solar Energy System
without approval of the Code Enforcement Officer (CEO) or the Planning Board as fol
lows:
1.
Solar Energy Systems or devices shall be installed or operated in the Town in
compliance with this performance standard and any other applicable local,
state and federal regulations or codes.
2.
Review and approval shall be determined by the Growth Management District
within the Town, type of solar system, and proposed size. The Town has desig
nated the proper permitting process for each solar system in the following ma
trix:
Review and Approval Authority for Solar Energy Systems
Resort
Development
District
General
Development
District
Rural District
Protection District
Principal Use
Medium-scale,
Ground-Mounted
SES
PB
PB
no
no
Large-scale,
Ground-Mounted
SES
PB
PB
no
no
Accessory Use
Rooftop SES
CEO
CEO
CEO
CEO
Small-scale,
Ground-Mounted
SES
CEO
CEO
CEO
PB
Medium-scale,
Ground-Mounted
SES
PB
PB
PB
no
D.
DIMENSIONAL REQUIREMENTS
1.
Roof-Mounted Solar Energy Systems shall be considered to be mechanical de
vices and, for purposes of height measurement, are restricted only to the extent
consistent with other building-mounted mechanical devices.
190 | Unified Development Review Ordinance
2.
Ground-Mounted Solar Energy Systems shall not exceed twelve (12) feet in
height when oriented at maximum tilt, except that the maximum height is
twenty-two (22) feet for systems set back at least thirty (30) feet from any prop
erty line.
3.
Setbacks for Ground-Mounted Solar Energy Systems
a.
Notwithstanding any other provision of this ordinance to the contrary, the
setbacks for Ground-Mounted Solar Energy Systems shall be as follows:
i.
The minimum front setback in all Growth Management Districts is
fifty (50) feet.
ii.
Minimum side and rear setbacks in all Growth Management Districts
is fifty (50) feet.
b.
Additional setbacks may be required to mitigate visual and functional im
pacts.
4.
Solar Energy Systems shall not be included in calculations for lot coverage or
impervious cover as defined in §11.F.
E.
STANDARD FOR APPROVAL
In addition to the site review standards and requirements established elsewhere in this or
dinance the following standards must also be met:
1.
Standards Applicable to All Solar Energy Systems
a.
The layout, design and installation shall conform to applicable industry
standards, such as those of the American National Standards (ANSI), Un
derwriters Laboratories (UL), National Electric Code (NEC), the American
Society for Testing and Materials (ASTM), Institute of Electrical and Elec
tronics Engineers (IEEE), Solar Rating and Certification Corporation
(SRCC), Electrical Testing Laboratory(ETL) or other similar certifying orga
nizations, and shall comply with local ordinances, and with all other appli
cable fire and life safety requirements. The manufacturer specifications
for the key components of the system shall be submitted as part of the ap
plication.
b.
An operations and maintenance plan, including site control and the pro
jected operating life of the Solar Energy System. Such a plan shall in
clude measures for maintaining safe access to the installation, stormwater
controls, as well as general procedures for operational maintenance of the
installation. Additionally, such plans shall include efforts to promote benefi
May 12, 2026
Section: 29 | 191
cial flora and fauna (e.g. honeybees, butterflies, etc.) as well as a commit
ment to not using pest-control substances (e.g. pesticides, herbicides,
fungicides, and/or insecticides).
2.
Large and Medium-Scaled Ground-Mounted Solar Energy Systems
a.
Lots - Solar Energy Systems shall not exceed 20% coverage of a lot area.
Lot coverage shall be calculated based on the total Solar Energy System
airspace projected over the ground. All Solar Energy Systems should be
designed and located to ensure solar and physical access without reliance
on and/or interference to/from adjacent properties.
b.
Legal Responsibilities - The Applicant must provide proof that it has au
thorization to construct, use and maintain the property and any access
drive for the life of the project and including the decommissioning of the
project. The roles and responsibilities of the Solar Energy System owner,
operator, landowner and any other party involved in the project must be
clear and meet the satisfaction of the Planning Board that the public inter
est is protected. The owner or operator of a Ground-Mounted Solar En
ergy System shall build and maintain it in compliance with all relevant fed
eral, state and local laws, regulations, and ordinances.
c.
Prohibited Locations - Components of a Large and Medium Scaled
Ground-Mounted Solar Energy System shall not be placed within any le
gal easement or right-of-way location, or be placed within any stormwater
conveyance system, or in any other manner that would alter or impede
stormwater runoff from collecting in a constructed stormwater conveyance
system.
d.
Utility Notification - No grid-intertied photovoltaic system shall be installed
until evidence has been given to the Code Enforcement Officer that the
applicant has an agreement with the utility to accept the power. Off-grid
systems are exempt from this requirement.
e.
Fence - Ground Mounted Solar Energy Systems shall be protected by a
perimeter fence. Such fences shall allow for small wildlife passage and
movement.
f.
Buffers and Screening - Lots on which Ground-Mounted Solar Energy
Systems are located shall be buffered and screened from roads and resi
dences by plantings, berms, and natural topographical features. Ground-
Mounted Solar Energy Systems shall be screened from view to the great
est extent practical of any adjacent property that is residential, as well as
any public way. Buffers and Screening shall comply with Section 18.AA.
192 | Unified Development Review Ordinance
g.
Glare - Solar Energy Systems shall be situated to eliminate concentrated
glare onto nearby structures or roadways.
h.
Noise - Solar Energy Systems or solar related equipment shall comply
with Section 18.Z., Noise.
i.
Lighting - Lighting shall be limited to that required for safety and opera
tional purposes and shall be shielded from interference with abutting prop
erties. Lighting of the Solar Energy System shall be directed downward
and shall incorporate full cut-off fixtures to reduce light pollution and shall
otherwise comply with the provisions of Section 18.O., Lighting Design
Standards. Other than required lighting, lighting shall not be used be
tween 9pm and 7am.
j.
Impervious Assessment - The surface area of the arrays of a Ground-
Mounted Solar Energy System, regardless of the mounted angle of any
solar panels, may or may not be considered impervious contingent upon
conformity with the stormwater management plan.
k.
Utility Connections - Reasonable efforts, as determined by the Planning
Board, shall be made to place all utility connections from the solar photo
voltaic installation underground, depending on appropriate soil conditions,
shape, and topography of the site and any requirements of the utility
provider. Electrical transformers for utility interconnections may be above
ground if required by the utility provider.
l.
Emergency Services - Solar Energy System owners or operators shall
provide a copy of the project summary, electrical schematic, and site plan
to the Code Enforcement Officer. Upon request, the owner or operator
shall coordinate with local emergency services in developing an emer
gency response plan. A "3200 Series KNOX-BOX", or agreed equivalent,
shall be provided and installed by the operator to be used to allow emer
gency service personnel continuous access. All means of shutting down
the Solar Energy System shall be clearly marked. The owner or operator
shall identify a responsible person for public inquiries throughout the life of
the installation.
m.
Maintenance Conditions - The Solar Energy System owner or operator
shall maintain the facility in good condition. Maintenance shall include,
but not be limited to, painting, structural repairs, vegetative screening,
fences, landscaping and plantings, and integrity of security measures.
The Solar Energy System must be properly maintained and be kept free
from all hazards, including, but not limited to, faulty wiring, loose fasten
May 12, 2026
Section: 29 | 193
ings, being in an unsafe condition or detrimental to public health, safety or
general welfare. Site access shall be maintained to a level acceptable to
the Code Enforcement Officer. The owner or operator shall be responsi
ble for the cost of maintaining the Solar Energy System and any access
road(s), including regular plowing of snow to maintain road access.
n.
Satisfaction with All Aspects of Capacity and Plans Submitted -- The Plan
ning Board must find that the Applicant has the capacity to finance, safely
operate and decommission the Solar Energy System.
o.
Removal - When any portion of a Ground-Mounted Solar Energy System
is removed, any earth disturbance must be graded and re-seeded, unless
authorized for another developed use.
p.
Alternatives Assessment - As determined by the Planning Board, if a pro
posed Ground-Mounted Solar Energy System does not meet the stan
dards in this Ordinance, then other potential suitable alternative area(s),
on the lot(s) included in the application, where a Solar Energy System can
meet the Ordinance's standards, should be evaluated by the Applicant.
Alternative lot areas should be evaluated against those same Ordinance
standards.
q.
Preservation of Town's Character - All reasonable efforts, as determined
by the Planning Board, shall be made to ensure any Solar Energy System
is consistent with the character of the community via visual consistency
with local neighborhood area, maintenance of scenic views, maintenance
of open space land and farms, and the Town Comprehensive Plan, and
associated Town planning documents.
3.
Small-Scaled Ground-Mounted Solar Energy Systems
a.
Lots - Solar Energy Systems shall not exceed 10% coverage of a lot area.
Lot coverage shall be calculated based on the total Solar Energy System
airspace projected over the ground. All Solar Energy Systems should be
designed and located to ensure solar and physical access without reliance
on and/or interference to/from adjacent properties.
b.
Prohibited Locations - Components of a Small Scaled Ground-Mounted
Solar Energy System shall not be placed within any legal easement or
right-of-way location, or be placed within any stormwater conveyance sys
tem, or in any other manner that would alter or impede stormwater runoff
from collecting in a constructed stormwater conveyance system.
194 | Unified Development Review Ordinance
c.
Glare - All Solar Energy Systems shall be situated to eliminate concen
trated glare onto nearby structures or roadways.
d.
Lighting - Lighting shall be limited to that required for safety and opera
tional purposes and shall be shielded from interference with abutting prop
erties. Lighting of the Solar Energy System shall be directed downward
and shall incorporate full cut-off fixtures to reduce light pollution and shall
otherwise comply with the provisions of Section 18.O., Lighting Design
Standards. Other than required lighting, lighting shall not be used be
tween 9pm and 7am.
e.
Preservation of Town's Character - All reasonable efforts, as determined
by the Planning Board, shall be made to ensure any Solar Energy System
is consistent with the character of the community via visual consistency
with local neighborhood area, maintenance of scenic views, maintenance
of open space land and farms, and the Town Comprehensive Plan, and
associated Town planning documents.
4.
Roof Mounted Solar Energy Systems
a.
The owner shall provide evidence certified by an appropriately licensed
professional that the roof is capable of supporting the collateral load of the
Solar Energy System.
b.
Solar Energy Systems mounted on roofs of any building shall be subject
to the maximum height regulations specified for principal and accessory
buildings within the applicable growth management district.
c.
Glare - All Solar Energy Systems shall be situated to eliminate concen
trated glare onto nearby structures or roadways.
d.
For firefighter access, a minimum three (3) foot buffer zone is required
from the ridge and one (1) edge of the roof or parapet.
e.
Preservation of Town's Character - All reasonable efforts, as determined
by the Code Enforcement Officer, shall be made to ensure any Solar En
ergy System is consistent with the character of the community via consis
tency with local neighborhood area, maintenance of scenic views, mainte
nance of open space land and farms, and the Town Comprehensive Plan,
and associated Town planning documents.
F.
DECOMMISSIONING AND REMOVAL
1.
Any Ground Mounted Solar Energy System that has reached the end of its use
ful life, ceases to generate power or has been abandoned shall be removed
May 12, 2026
Section: 29 | 195
pursuant to a plan approved by the Planning Board during the application
process. The landowner, or Solar Energy System owner or operator shall
physically remove the installation no more than 180 days after the date of dis
continued operations. The owner or operator shall notify the Code Enforce
ment Officer by certified mail, return receipt requested, of the proposed date of
the discontinued operations and plans for removal.
2.
Decommissioning shall consist of:
a.
physical removal of all Solar Energy Systems, structures, equipment, se
curity barriers and transmission lines from the site;
b.
disposal of all solid and hazardous waste in accordance with local, state
and federal waste disposal regulations; and
c.
stabilize or re-vegetation of the site as necessary to minimize erosion.
The Code Enforcement Officer may allow the owner or operator to leave
landscaping or designated below-grade foundations to minimize erosion
and disruptions to vegetation.
3.
Absent a notice of a proposed date of decommissioning or written notice of ex
tenuating circumstances, a Ground Mounted Solar Energy System shall be
considered abandoned when it fails to generate 10% or less permitted capacity
of electricity for a continuous period of twelve (12) months without having first
obtained the written consent of the Code Enforcement Officer. Determination
of abandonment shall be made by the Code Enforcement Officer.
4.
If the owner or operator of a Ground Mounted Solar Energy System fails to re
move the installation in accordance with the requirements of this section within
180 days of abandonment or the proposed date of decommissioning, the Town
of Newry retains the right to use the performance guarantee and any and all le
gal or available means necessary to cause an abandoned, hazardous or de
commissioned Solar Energy System to be removed.
G.
MODIFICATIONS
1.
Any physical modification to any existing Solar Energy System, whether or not
existing prior to the effective date of this Ordinance, shall require review and
approval under this performance standard.
2.
Any modifications to a Medium to Large Scaled Ground-Mounted Solar Energy
System made after issuance of the required town permit(s) shall require ap
proval by the Planning Board.
196 | Unified Development Review Ordinance
3.
Any modifications to a Small-Scaled Ground-Mounted Solar Energy System
made after issuance of the required town permit(s) shall require approval by
the Code Enforcement Officer.
4.
Application fees for modifications shall be consistent with the overall size of the
Solar Energy System, not solely the modification.
5.
Permit fees for modifications shall be based on the modified portion of the So
lar Energy System.
May 12, 2026
Section: 29 | 197
SECTION 30: RECREATIONAL LODGING FACILITIES
SECTION USER'S GUIDE: This section establishes design, construction, and op
erational standards for lodging facilities that are primarily natural resourced-
based, such as campgrounds, sporting camps, and rental cabins.
A.
APPLICABILITY
1.
Where a recreational lodging facility takes place in shoreland zoning districts,
the provisions of the Shoreland Zoning Ordinance apply and the more restric
tive of the two shall govern.
2.
When a recreational lodging facility is reviewed by the Planning Board Site
Plan Review, approval in accordance with this Section is required.
3.
All new recreational lodging facilities must be developed in conformance with
the standards of this Section. Non-conforming recreational lodging facilities
must abide by §11 of this Ordinance.
4.
If two or more recreational lodging facilities are located on abutting parcels, and
are under unified or affiliated ownership or control, they shall be deemed to be
one recreational lodging facility for purposes of this Section.
5.
Recreational lodging facilities must conform to the minimum requirements im
posed under State licensing procedures. The Planning Board's approval is
conditional on the State license approval.
B.
OPERATING STANDARDS
1.
All recreational lodging facilities must be inspected annually by May 1 and if
found to be in compliance with all applicable Newry Ordinances, issued a per
mit by the Code Enforcement Officer.
2.
Each recreational lodging facility unit shall be provided with a trash receptacle
thirty gallons or larger.
3.
Each recreational lodging facility unit and/or any common area equipped with a
fire pit shall be equipped with a smokeless fire pit, the construction of which
must be approved by the the Code Enforcement Officer
4.
A facility manager must be on the premises twenty-four (24) hours a day when
the recreational lodging facility is in operation.
5.
Sound level limits set in §18.Z.1., Noise, must be enforced.
6.
A recreational vehicle or motor home may not be rented, leased or occupied for
more than two (2) weeks consecutively from November 1st through April 30th un
May 12, 2026
Section: 30 | 199
less the recreational vehicle or motor home is connected to a permanent
sewage, water, electricity and heat that will meet State and local codes. From
November 1st through April 30th renewal of any occupancy in a recreational ve
hicle or motor home may not occur unless there is a least one (1) week of non-
occupancy.
7.
Recreation vehicles or motor homes at individual recreational lodging facility
units shall not have permanent foundations and shall not have the wheels re
moved.
8.
A tent, trailer, camper, recreational vehicle, motor home or similar device used
for camping may be stored within a storage area on the premises of the recre
ational lodging facility provided that the device is not utilized or inhabited while
located within the storage area. Recreational lodging units may not be used as
a storage facility.
9.
Staff housing may not be used as a recreational lodging facility unit. See SEC
TION 30:C.3.b.
C.
LAND USE STANDARDS
1.
Minimum Site Size - The minimum site size for a recreational lodging facility
shall be ten (10) acres.
2.
Density
a.
The maximum density for a recreational lodging facility shall be one unit
per five thousand (5,000) square feet of suitable land area except for
primitive campsites which shall be ten thousand (10,000) square feet.
b.
Land supporting wetland vegetation, land below the normal high-water
line of a water body and land with a sustained slope of fifteen (15) percent
or greater shall not be included in calculating land area per site.
3.
Maximum Number of Units
a.
The maximum number of units used as sleeping accommodations in a
recreational lodging facility, excluding staff housing for the facility, shall be
fifty (50) units.
b.
The Planning Board may permit reasonably necessary staff housing as an
accessory use to a recreational lodging facility. Staff housing must be
designated on the Site Plan Application and may not be used as a recre
ational lodging facility unit.
200 | Unified Development Review Ordinance
4.
Minimum Setbacks - A unit of a recreational lodging facility shall meet the fol
lowing setback requirements:
a.
At least one hundred (100) feet from the center line of any public street or
highway and twenty-five (25) feet from the edge of the right-of-way or a
road providing access to the unit.
b.
At least fifty (50) feet from the property line of abutting properties.
c.
At least one hundred (100) feet from the normal high-water mark of a
great pond, river, stream, brook or upland edge of a wetland.
d.
The areas intended for placement of utility and service buildings, and ac
cessory uses associated with outdoor activities; such as fire pits, clothes
lines, and picnic tables shall be set back a minimum of fifty (50) feet from
the exterior lot lines, one hundred (100) feet horizontal distance, from the
normal high-water line of a great pond, river, tributary streams, or the up
land edge of a wetland.
5.
Any recreational lodging facility unit that consist of temporary or permanent
structure such as yurts, cabins, cottages and other types of shelter shall not be
placed within a floodplain.
6.
Recreational lodging facilities shall be screened from all abutting areas accord
ing to the performance standards in §18.AA.
7.
Recreational lodging facilities must conform to the most recently adopted State
of Maine Subsurface Wastewater Disposal Rules (10-144 CMR 241). This in
cludes a pit or vault privy servicing primitive campsites.
May 12, 2026
Section: 30 | 201
APPENDIX 1: EXHIBITS AND MAPS
SECTION USER'S GUIDE: This section contains exhibits and maps referenced
elsewhere in this Ordinance.
EXHIBIT A.
May 12, 2026
Section: | 203
EXHIBIT B.
204 | Unified Development Review Ordinance
May 12, 2026
Section: | 205
EXHIBIT C.
206 | Unified Development Review Ordinance
Approved by: Town of Newry Planning Board
Date: ____________
Signed: ______________________________ Chairperson
______________________________ Board Members
______________________________
EXHIBIT D.
GROWTH MANAGEMENT DISTRICT MAP
May 12, 2026
Section: | 207