Town of Warren
----------------------------------
Model Housing Code
Adopted March 16, 1970
266 yea
169 nay
Model Housing Code
Table of Contents
General Provisions
page
Section 1
Scope
1
Section 2
Severability
1
Section 3
Definitions
1
Section 4
Occupancy Requirements
2
Section 5
Prohibited Uses
2
Section 6
Habitable Space Requirements
3
Section 7
Public Space
3
Section 8
Accessory Rooms
4
Section 9
Access Between Stories
5
Section 10
Exits
5
Structural Requirements for Residential Premises
Section 11
General Requirements
5
Section 12
Exterior Protection
5
Section 13
Interior Protection
6
Equipment Requirements
Section 14
General Requirements
6
Section 15
Plumbing
6
Section 16
Fuel Gas
6
Section 17
Heating
7
Section 18
Electrical
8
Section 19
Cooking and Refrigeration
8
Section 20
Fuel Oil
8
Fire Safety Requirements
Section 21
Prohibited Accumulations
9
Section 22
Preventing Fire Spread
9
Section 23
Interior Finish
9
Section 24
Fireplaces
9
Section 25
Extinguishers
9
Property Maintenance Requirements
Section 26
Open Areas
9
Section 27
Buildings and Structures
10
Section 28
Infestation and Screening
10
Section 29
Garbage and Refuse
10
Compliance
Section 30
Responsibility of Owners
10
Section 31
Of Rooming House Operator
11
Section 32
Of Occupants
11
Administration
Section 33
Building Coordinator
11
Section 34
Inspection
11
Section 35
Enforcement
12
Seciton 36
Violations
12
Town of Warren Model Housing Code
page 1
Y 266 March 16, 1970
N 169
Model Housing Code
CHAPTER 733
Housing Code
An ordinance establishing minimum standards governing the condition and maintenance of
dwellings; establishing minimum standards governing supplied utilities and facilities and other physical
things and conditions essential to make dwellings safe, sanitary, and fit for human habitation;
establishing minimum standards governing the condition of dwellings offered for rent; fixing certain
responsibilities and duties of owners and occupants of dwellings; authorizing the inspection of
dwellings, condemnation of dwellings unfit for human habitation; and fixing penalties for violation.
Whereas, in the Municipality of Warren, there are, or may in the future be, dwelling structures
which are so dilapidated, unsafe, dangerous, unhygienic, or insanitary as to constitute a menace to the
health and safety of the people of this Municipality.
General Provisions
Sec. 1. Scope: This ordinance shall apply to residential premises as follows:
I. Lots, plots, or parcels of land on which residential buildings, buildings of mixed occupancy
or accessory structures are located;
II. Residential buildings, including one and two-family dwellings, multiple dwellings, and
rooming or boarding houses;
Sec. 2. Severability: The provisions of this ordinance shall be severable, and if any phrase, clause,
sentence or provision of this ordinance, or the application thereof, to any person or
circumstance is held invalid, the remainder of the ordinance and the application thereof to any
other persons or circumstances shall not be affected thereby.
Sec. 3. Definitions: The listed terms as used in this chapter are defined as follows, unless a different
meaning is plainly required by context.
I.
Basement. That portion of a building located partly or entirely underground but having
less than half its clear floor to ceiling height below the average grade of the adjoining
ground.
II.
Cellar. That portion of a building located partly or entirely underground but having half
or more than half its clear floor to ceiling height below the average grade of the
adjoining ground.
III.
Dwelling. Any building which is wholly or partly used or intended to be used for living
or sleeping by human occupants.
IV.
Dwelling Unit. Any room or group of rooms located within a dwelling and forming a
single habitable unit with facilities which are used or intended to be used for living,
sleeping, cooking and eating.
V.
Family. A household constituting a single housekeeping unit occupied by one or more
persons.
VI.
Finished Grade. Natural surface of the ground, or surface of ground after completion of
any change in contour.
Town of Warren Model Housing Code
page 2
VII.
Habitable Space. Space occupied by one or more persons living, sleeping, eating, or
cooking. Kitchenette shall not be deemed to be habitable space.
VIII. Immediately Family. Immediate family shall mean mother, father, sister, brother, and
children of the owner or occupant and spouse.
IX.
Kitchen. Space, 60 square feet or more in floor area, used for cooking or preparation of
food.
X.
Kitchenette. Space, less than 60 square feet in floor area, used for cooking or
preparation of food.
XI. Mixed Occupancy. Occupancy of a building in part residential use, in part some other
use not accessory thereto.
XII.
Multiple Dwelling. Any dwelling containing more than two dwelling units.
XIII. Premises. A lot, plot, or parcel of land including the buildings or structures thereon.
XIV. Public Space. That space used in common by the occupants of several units within a
dwelling or rooming house and by the public.
XV.
Rooming House. Any dwelling, or part of any dwelling, containing one or more
rooming units, in which space, is let by the owner or operator to four or more persons
who are not members of his immediate family.
XVI. Rooming Unit. Any room or group of rooms forming a single habitable unit used or
intended to be used for living and sleeping, but not for cooking or eating purposes.
XVII. Stairways. One or more flights of stairs and the necessary landings and platforms
connected therewith to form a continuous passage from one floor to another.
XVIII. Story. Portion of a building, which is between one floor level and the next higher floor
level or the roof. If a mezzanine floor area exceeds one-third of the area of the floor
immediately below, it shall be deemed to be a story. A basement shall be deemed to be
a story only when its ceiling is six or more feet above the finished grade.
XIX. Toilet Room. Enclosed space containing one or more water closets, which may also
contain one or more lavatories, and other plumbing fixtures.
Space and Occupancy Requirements
Sec. 4. Occupancy Requirements.
I. Dwelling units. Occupants shall be limited to the number determined on the basis of the
floor areas of habitable rooms as follows:
One occupant per room having floor area of at least 80 but less than 120 square feet;
two occupants per room having floor area of at least 120, but less than 180 square feet;
and three occupants per room having floor area of 180 or more square feet.
II. Rooming Units. The number of occupants shall be limited to the number determined on the
same basis as for dwelling units.
III. Notice of Permitted Occupancy to be Posted. Notice shall be posted in each unit offered for
rent stating the maximum number of occupants allowed under this ordinance.
Sec. 5. Prohibited Uses.
I. Sleeping. No kitchen, nonhabitable space, or public space shall be used for sleeping
purposes.
II. Preparing Meals. Meals shall not be prepared in any room other than a kitchen or
kitchenette.
III. Cellars. Cellar space shall not be used as habitable space.
Town of Warren Model Housing Code
page 3
IV. Basements. No basement space shall be used as a habitable space unit unless the floors and
walls are free form chronic dampness and protected from surface runoff.
Sec. 6. Habitable Space Requirements.
I. Minimum Ceiling Height. Fifty percent of the floor area shall have a minimum ceiling
height of 7 feet 6 inches, and any floor area where the ceiling height is less than 5 feet
shall not be considered in computing floor area.
II. Rooms - Minimum Size. Every dwelling unit shall contain at least one habitable room
having a minimum of 150 square feet of floor area with no horizontal dimension of less
than 10 feet. Every other habitable space, except kitchens, shall contain not less than 80
square feet of floor area and shall have no horizontal dimension of less than seven feet.
III. Alcoves to be part of Habitable Rooms. Every alcove having less than 60 square feet in
area, except a kitchenette or foyer, shall be deemed to be part of an adjacent room. The
area of the opening in the dividing partition between the alcove and the room shall be at
least 80 % of the wall area of such partition, measured on the alcove side but in no case
less than 40 square feet. The floor area of the alcove shall be added to the floor area of
the room in determining light and ventilation requirements for the room. Any alcove
with an area of more than 60 square feet shall be separately lighted and ventilated as
required for habitable space.
IV. Light and Ventilation.
A. Habitable space shall be provided with natural light through one or more windows,
skylights, transparent or translucent panels, or any combinations thereof that open
directly to the outdoors, at least six inches above the adjoining finished grade, or are
above a roof. The amount of light shall be equivalent to that transmitted through
clear glass equal in area to at least 10% of the floor area of the room.
B. Every room shall be provided with artificial light.
C. Every habitable room shall be provided with natural ventilation through windows or
other openings in exterior walls that face directly out-of-doors above the adjoining
finished grade or above a roof, or though skylights, providing total clear ventilation
area that is equal to not less than 5% of the total floor area of each habitable space.
D. Habitable rooms may also be provided with mechanical ventilation, but this may not
be substituted for natural ventilation.
V. Miscellaneous Requirements.
A. Rooming units shall be separated from each other and from other spaces outside the
rooming units.
B. A communal kitchen or dining room in a rooming house shall be accessible to the
occupants sharing such kitchen or dining room without going through a dwelling
unit or rooming unit of another occupant.
Sec. 7. Public Space.
I. Height. Public space shall have a minimum height of seven feet six inches measured from
finished floor to finished ceiling.
II. Light and Ventilation.
A. Public spaces shall be provided with electric lighting.
B. In public stairs, stairways, and passageways, electric lighting shall be available at all
times so as to afford safe visible passage for occupants and users. Such lighting
shall conform to the following requirements:
Town of Warren Model Housing Code
page 4
1. A sufficient number of fixtures shall be provided so that the distance
between fixtures is not more than 30 feet, and so that no wall is more than 15
feet distant from a fixture.
2. Incandescent lighting shall be based on not less than ¼ watt per square foot
of floor area, except that no fixture shall have lamp with less than 25 watts.
3. Florescent lighting shall be based on not less than 1/10th watt per square foot
of floor area, except that no fixture shall have a lamp with less than 15 watts.
4. Where under these formulas the calculated wattage does not correspond to
that of a standard lamp the next larger standard size shall be used.
C. Public spaces shall be provided with either natural ventilation, conforming to the
requirements for habitable space, or with mechanical ventilation.
Sec. 8. Accessory Rooms.
I. Toilet Rooms and Bathrooms.
A. Toilet rooms and bathrooms in one and two-family dwelling shall have provisions
for privacy.
B. Toilet rooms and bathrooms for dwelling units in multiple dwellings shall be located
within each dwelling unit and shall be accessible from any sleeping room without
passing through any other sleeping room.
C. In one and two family dwelling, bathrooms and toilet rooms shall be provided with
floors of moisture-resistant material.
D. In multiple dwellings, floors of bathrooms, toilet rooms and similar spaces shall be
waterproof; such waterproofing shall extend six inches or more up on adjacent walls
except at doors, so that floors can be flushed or washed without leaking.
II. Lighting and Ventilation
A. Kitchenettes, bathrooms, and toilet rooms shall be provided with artificial light
appropriate for the use of such rooms.
B. Laundry rooms, furnace rooms, and similar spaces shall be provided with artificial
light appropriate for the intended use of such rooms.
C. Kitchenettes shall be provided with ventilation in accordance with either of the
following:
1. Natural ventilation as required for habitable space, except that such
openable areas shall be not less than 3 square feet.
2. Mechanical ventilation exhausting not less than 100 cfm.
D. Bathrooms and toilet rooms shall be provided with ventilation in accordance with
either of the following:
1. Natural ventilation as required for habitable space, except that such
openable areas shall not be less than 1 ½ square feet.
2. Mechanical ventilation exhausting not less than 25 cfm.
E. Spaces in multiple dwellings, which contain central heating, air conditioning and
similar equipment, shall be ventilated to the outer air, and air from these spaces shall
not be recirculated to other parts of the building.
F. Natural ventilation shall be provided in unheated attics, spaces below flat roofs, and
crawl spaces. Ventilation location and not areas of openings shall be such as to
minimize deterioration form condensation or other causes, in conformity with
generally accepted standards.
Town of Warren Model Housing Code
page 5
Sec. 9. Access and Vertical Travel between Stories.
I. Stairs. Stairs, both interior and exterior to serve the occupants shall be of sufficient width
and in conformity with generally accepted standards.
II. Railings. Hand railings shall be provided on all portions of stairs, balconies, landings, and
stairwells.
Sec. 10. Exits.
I. Exits Shall Be Unobstructed. Safe, continuous and unobstructed exits shall be provided
from the interior of the building to the exterior at street or grade level. In multiple
dwellings such exits shall open out.
II. Construction and Arrangement. Exits shall be arranged, constructed and proportioned so
that occupants may safely escape from the building in case of emergency.
III. Exits in One and Two-Family Dwellings. In one and two-family dwellings there shall be
two grade level exits for each unit, and only one such exit may be for joint use.
IV. Exits in Multiple Dwellings. In multiple dwellings two exits shall be provide on each story.
Structural Requirements for Residential Premises
Sec. 11. General Requirements.
I. Loads. Buildings and parts thereof shall be maintained so as to be capable of sustaining
safely their own weight and the loads to which they may be subject.
II. Loads Transmitted to Soil. Buildings shall be maintained so that loads are transmitted to the
soil without undue differential settlement, unsafe deformation or movement of the building
or any structural part.
Ill. Protection of Structural Members. All structural members shall be protected against
freezing and thawing, dampness, corrosion, wetting and drying, termites and other
destructive insects, and all similar causes of deterioration.
V. Basements and Cellars to be Kept Dry. Buildings built in soil which is water bearing at any
season of the year shall be maintained so that ground and surface water will not penetrate
into habitable spaces, basements and cellars.
Sec. 12. Exterior Protection.
I. Foundation Walls. Foundation walls shall be maintained so as to be structurally sound and
to prevent entrance of moisture, termites and vermin by shoring where necessary, installing
subsoil drains at footings, grouting of masonry cracks, waterproofing of walls and joists, or
other suitable means.
II. Exterior Walls. Exterior wall components shall be maintained so as to prevent deterioration
due to the elements and destructive insects by painting, installing or repairing termite
shields, by poison treatment of soil, or other suitable means.
Ill. Roofs. Roofing shall be maintained in watertight condition so as to prevent leakage into the
building by repairs to roofing, flashings, waterproof coatings, or other suitable means.
Town of Warren Model Housing Code
page 6
Sec. 13. Interior Protection.
I. Subterranean Crawl Space. Crawl spaces shall be maintained free of moisture and the flow
of air from such spaces into walls above shall be effectively barred so as to prevent
deterioration of structural members or spread of fire. Foundation walls shall have openings
to provide adequate circulation of air in any subterranean crawl space. The ground in the
crawl space shall be covered with a moisture barrier if the crawl space is below surrounding
grade. Openings shall be blocked in stud walls to prevent flow of air and moisture into
walls. Termite tubes from the soil to wood floor members above shall be kept destroyed.
The soil shall be poison treated when necessary.
II. Structural Members. Structural members shall be maintained so as to be structurally sound
by shoring, reinforcement or repair when necessary, destruction of termite tubes, and other
appropriate maintenance.
III. Chimneys and Flues. Chimneys and flues shall be maintained so as to be structurally sound
and to prevent leakage of gases into the structure. Flue stoppages shall be cleared, open
joints sealed, masonry repaired where necessary.
Equipment Requirements
Sec. 14. General Requirements - Equipment.
I. Plumbing, heating, electrical, ventilating, air conditioning, refrigerating, cooking, radiation
producing equipment, elevators, dumbwaiters, escalators and other mechanical additions,
installations, or systems for the use of the building shall be installed, located and
maintained so that under normal conditions of use such equipment and systems will not be
a danger because of structural defects, or a source of ignition or a radiation hazard, and will
not create excessive noise, or otherwise become a nuisance. Equipment and systems include
but are not limited to apparatus, devices, fixtures, piping, pipe hangers, pipe covering,
wiring, fittings, and materials used as part of, or in connection with such installations.
II. Equipment and systems subject to damage from freezing shall be adequately protected
against freezing.
III. Moving parts of equipment, which may be a potential hazard shall be safeguarded to protect
against accidental physical contact.
Sec. 15. Plumbing.
I. General. All plumbing and sewage disposal shall be in strict conformance with the State
Plumbing Code and local plumbing code.
II. Storm Drainage. Roofs and paved areas, including yards and courts shall be drained in the
method as provided for in the applicable plumbing code.
III. Sanitary Fixtures. There shall be provided within each dwelling unit not less than one water
closet, one bathtub or shower, one lavatory, and one kitchen sink, all of approved type with
piped cold water to all fixtures and piped hot water to all fixtures but the water closet.
Sec. 16. Fuel Gas.
I. General Requirements
A. Fuel gas piping systems shall be installed and maintained so as to remain gas-tight, safe,
and operative under all conditions of use.
Town of Warren Model Housing Code
page 7
B. Fuel gas piping systems shall provide a supply of gas sufficient to meet the maximum
expected demand of the installed gas burning appliances connected thereto.
II. Shutoff Valves.
A. Gas piping systems shall have at least one accessible means for shutting off all gas
supply and such means shall be maintained in good operating condition.
B. An easily accessible shutoff valve or cock shall be provided in the piping in close
proximity to, and ahead of every outlet for gas appliances.
III. Gas Refrigerators and Ranges. Gas refrigerators and ranges shall be installed with
clearance for ventilation, and shall be maintained in good operating condition.
IV. Liquefied Petroleum Gas.
A. Undiluted liquefied petroleum gas in liquid form shall not be conveyed through piping
equipment and systems in buildings.
B. Liquefied petroleum gas shall not be vaporized by devices utilizing open flame or open
electrical coil.
C. Where two or more containers are installed, connection shall be arranged so that
containers can be replaced without shutting off the flow of gas to the equipment.
D. Containers shall be designed, stored, and located so as not to be a hazard to the premises
served, or to the surrounding property.
E. Systems shall be provided with safety devices to relieve excessive pressures, and shall
be arranged so that the discharge terminates at a safe location.
F. Systems shall have at least one accessible external means for shutting off the gas. Such
means shall be located outside the building, and shall be maintained in good operating
condition.
Sec. 17. Heating.
I. General Requirements. Residential buildings intended for year-round occupancy shall be
provided with heating equipment designed to maintain a temperature of not less than 75
degrees F. at a distance of three feet and more from exterior walls, and at a level of five feet
above the floor, in habitable spaces, kitchenettes, bathrooms, and toilet rooms. The
capability of the heating equipment to maintain such indoor temperature shall be based on
outside temperatures of -20 degrees F.
II. Smoke Control. Fuel-burning heat-producing equipment shall be installed and maintained
so that the emission or discharge into the atmosphere of smoke, dust particles, odors or
other products of combustion will not create a nuisance or be detrimental to the health,
comfort, safety, or property of any person.
III. Warm Air Heating. Ducts and other air handling equipment used for heating shall conform
to the requirements of such equipment used for ventilating purposes.
IV. Prohibited Locations for Heat-Producing Equipment. Fuel-burning water heaters shall not
be located in sleeping rooms, bathrooms, or toilet rooms.
V. Fuel Supply Connection. Heat-producing fuel-burning shall be permanently fastened and
connected in place. Any liquid fuel supply connected to such equipment shall be made with
pipe or tubing of solid material.
VI. Installation and Clearance. Where heat-producing equipment is installed on, or adjacent to,
combustible materials, the location, insulation, clearance, and the control of the equipment
shall be such that the temperature on the surface of the combustible materials will not
exceed a safe temperature.
Town of Warren Model Housing Code
page 8
VII. Air Supply.
A. Direct-fired heat-producing equipment and the enclosure in which it is located shall be
provided with a supply of air adequate both for complete combustion at the rated gross
output of the equipment and for the ventilation of the enclosure to prevent the
accumulation of heat or gasses.
B. Rooms containing fuel-burning equipment shall have such air supply provided by
means of one or more openings to the exterior.
VIII. Removal of Products of Combustion.
A. Equipment for burning solid or liquid fuels shall be connected to suitable chimneys or
flues and shall not be connected to gas vents. Unvented heaters burning liquid fuels are
prohibited.
B. Fuel-burning space heaters shall be connected to a suitable chimney or flue.
C. Gas-fired equipment shall be connected to a suitable chimney, flue or gas vent.
IX. Safety Devices.
A. Equipment capable of developing hazardous pressures or temperatures shall be provided
with means to relieve safely such pressures and temperatures.
B. Controls for the safe operation of automatically operated heat producing equipment
shall be provided to function as follows:
1. When failure or interruption of flame or ignition occurs the fuel supply shall be cut
off.
2. When a predetermined temperature or pressure is exceeded, the input of additional
heat shall be prevented or reduced to a safe rate.
3. When the water in a steam boiler drops below a predetermined level, the fuel supply
shall be cut off.
4. When failure or interruption of pilot light or main burner of liquefied petroleum gas
equipment occurs, the fuel supply to each pilot light and main burner shall be cut
off.
X. Heating of Garages. Fuel-burning equipment for garages shall be installed to operate in a
safe manner.
Sec. 18. Electrical. All buildings used for residential purposes shall be wired for electricity in
conformity with the electrical code.
Sec. 19. Cooking and Refrigeration.
I. Each dwelling unit shall be provided with appropriate cooking and refrigeration equipment.
II. Cooking and refrigeration equipment shall be maintained in good operating condition.
III. Fuel-burning cooking equipment shall be appropriately vented.
Sec. 20. Fuel Oil.
I. General Requirements. Fuel oil shall be received, stored and conveyed by means of fixed
liquid-tight equipment.
II. Storage Tanks.
A. Tanks shall be provided with means for venting.
B. Tanks shall be installed and maintained so as not to be a hazard to the premises served
or the surrounding property.
III. Automatically Operated.
A. Boilers and furnaces using fuel oil shall be provided with remote control to stop the
flow of oil during fire or other emergency.
Town of Warren Model Housing Code page 9
B. Filling, emptying and venting of tanks shall be by means of fixed piping. Pipes to
underground tanks shall be pitched toward tanks. Terminals of fill and vent pipes shall
be located outside buildings at a safe distance from building openings.
Fire Safety Requirements
Sec. 21. Prohibited Accumulations and Storage. No paints, volatile oils, cleaning fluids, or similar
flammable or explosive matter, and no waste paper, boxes, rags, or similar matter liable to
spontaneous combustion shall be stored on residential premises except in a safe and well
ventilated location.
Note: R.S., C. 97, Sec. 49 -- Storage of any matter on fire escape
prohibited.
Sec. 22. Prevention of Spread of Fire.
I. Walls and ceilings shall be free from cracks.
Walls and ceilings shall be maintained free from cracks and openings, which would permit
flames or excessive heat to enter the concealed space.
II. Buildings of Mixed Occupancy - Fire Separations.
In buildings of mixed occupancy, nonresidential space shall be separated from residential
space by approved separations, which will retard the spread of fire.
Sec. 23. Interior Finisher. - Trim and Decorative Materials. Interior finish materials for acoustical
correction, surface insulation and decorative treatment on the surfaces of walls and ceilings,
and interior trim shall be materials that will not, in burning, give off excessive amounts of
smoke or toxic gasses.
Sec. 24. Fireplaces.
I. Connection to Chimneys. Fireplaces and similar construction used or intended to be used,
for burning fuel in open fires shall be connected to approved chimneys and shall be
installed so that nearby or adjacent combustible material and structural members shall not
be heated to unsafe temperatures.
II. Hearths and Linings. Hearths and linings or other parts of fireplaces shall be of materials
that will not melt, disintegrate, or shatter when exposed to direct flame.
III. Wood Mantels and Trim. Wood mantles and trim on fireplaces shall be placed and attached
so that they cannot be heated to unsafe temperatures or ignited by sparks or embers from
the fire.
Sec. 25. Portable Extinguishers Required in Multiple Dwellings. Each oil burner for boiler, furnace,
or central hot water heater shall be provided with an approved hand fire extinguisher or two
pails of at least 10-quart capacity filled with sand. Portable extinguishers shall be in
accessible locations and in a condition, which will permit efficient operation without delay.
Property Maintenance Requirements
Sec. 26. Open Areas.
I. Surface and Subsurface Drainings. Surface and subsurface water shall be drained to protect
Town of Warren Model Housing Code
page 10
buildings and structures and to prevent development of stagnant ponds. Cutters, culverts,
catch basins, drain inlets, storm water sewers, approved combination storm and sanitary
sewers, or other satisfactory drainage systems shall be used where deemed necessary.
II. Fences. Fences and other minor structures shall be maintained in safe and substantial
condition.
III. Paved Areas. Steps, walks, driveways, parking spaces, and similar paved areas shall be
maintained so as to afford safe passage under normal use and weather conditions.
IV. Yards and Courts. Yards and courts shall be kept clean and free of physical hazards, and the
accumulation of debris and trash.
V. Noxious Undergrowth. Heavy undergrowths and accumulations of plant growth which are
noxious or detrimental to health shall be eliminated.
Sec. 27. Buildings and Structures.
I. Exterior Wood Surfaces. Exterior wood surfaces of buildings and structures that are not
inherently resistant to deterioration shall be periodically treated with a protective coating of
paint or other suitable preservative.
II. Floors, Walls, Ceilings, Etc. Floors, walls, ceilings, furnishings and fixtures of residential
buildings shall be maintained in clean and sanitary condition.
III. Accessory Structures. Accessory structures shall be maintained so as to be free of
conditions detrimental to safety and/or health.
Sec. 28. Infestation and Screening.
I.
Grounds, Buildings and Structures. Grounds buildings, and structures shall be maintained
free of insect, vermin, and rodent harborage and other infestation. Methods used for
exterminating insects, vermin, and rodents shall conform with generally accepted practices.
II. Cellar and Basement Windows and Openings to be Screened. Windows and other openings
in basement and cellars shall be appropriately screened with wire mesh or other suitable
materials to prevent ingress of insects, rodents and other vermin.
III. Windows and Doors to be Screened during Certain Months. From May 1 to October 1,
entrances to residential buildings shall be provided with self-closing type screens and
windows and other openings used for ventilation shall be appropriately screened.
Sec. 29. Garbage and Refuse
I. Storage, Handling and Disposal. Adequate sanitary facilities and methods shall be used for
the collection, storage, handling and disposal of garbage and refuse.
II. Storing Refuse in Public Halls Prohibited. In multiple dwellings
garbage and refuse shall not be stored or allowed to accumulate in public halls and
stairways.
Compliance
Sec. 30. Responsibility of Owners
I. Owners of premises shall be responsible for compliance with this ordinance, and shall
remain responsible therefore regardless of the fact that this section may also place certain
responsibilities on operators and occupants and regardless of any agreements between
owners and operators or occupants as to which party shall assume such responsibility.
Town of Warren Model Housing Code
page 11
II. Owners of premises shall be responsible for proper maintenance, condition and operation of
service facilities.
Sec. 31. Responsibilities of Rooming House Operators. Rooming house operators shall be
responsible for compliance with this ordinance in regard to the following:
I.
Limiting occupancy to the maximum permitted by this ordinance;
II.
Maintenance of safe and sanitary conditions in all parts of rooming house premises;
Ill.
Maintenance and operation of all required service facilities;
IV. Maintenance of all plumbing, cooking and refrigeration fixtures and appliances within his
control, as well as other building equipment and facilities, in an operative, clean, and
sanitary condition;
V.
Sanitary maintenance of walls, floors, and ceilings;
VI. Keeping exits clear and unencumbered;
VII. Disposal of building garbage and refuse in a clean and sanitary manner;
VIII. Extermination of insects, rodents, or other pests on the premises;
IX. Hanging and removing required screens.
Sec. 32. Responsibilities of Occupants. Occupants of dwelling units shall be responsible for
compliance with this ordinance in regard to the following:
I.
Limiting occupancy of that part of the premises which he occupies or controls to the
maximum permitted by this ordinance.
II.
Maintenance of that part of the premises, which he occupies or controls in a clean,
sanitary and safe condition.
Ill.
Maintenance of all plumbing, cooking, and refrigeration fixtures and appliances, as well
as other building equipment and storage facilities in that part of the premises which he
occupies or controls, in a clean and sanitary condition, and providing reasonable care in
the operation and use thereof.
IV. Keeping exits from his dwelling unit clear and unencumbered.
V.
Disposal of garbage and refuse into provided facilities in a clean and sanitary manner.
VI. Extermination of insects, rodents, or other pests within his dwelling unit.
VII. Hanging and removing required screens.
VIII. Keeping his domestic animals and pets in an appropriate manner and under control.
Administration
Sec. 33. Building Coordinator. This ordinance shall be administered by the Building Coordinator.
I. Adopted Rules and Regulations. The Building Coordinator is hereby authorized to adopt
rules and regulations necessary for securing the compliance with this ordinance, providing
that such rules and regulations shall not be in conflict with any provision of this ordinance.
A certified copy of all such rules and regulations shall be filed with the municipal clerk.
II. Cooperation. The Building Coordinator shall cooperate with other municipal governmental,
and private agencies engaged in the study and improvement of housing condition.
Sec. 34. Inspection.
I. Conduct Surveys. The Building Coordinator is hereby authorized to conduct surveys of
housing in any area of the municipality to determine the condition of premises, extent of
Town of Warren Model Housing Code
page 12
deterioration, lack of facilities, inadequate maintenance, unsafe and insanitary condition,
extent of overcrowding, land use, and other relevant factors.
II. Periodic Examinations. Periodic examinations shall be made not less than once every five
years of all premises within the scope of this ordinance.
III. Investigate Complaints. The Building Coordinator shall investigate all complaints of
alleged housing violations.
IV. Right of Entry. The Building Coordinator, in the performance of his duties, shall have the
right to enter any premises at reasonable hours for the purpose of making the examinations
required by this ordinance.
V. Owners and Occupants to Give Free Access. Owners, agents, operators, and occupants shall
provide access to all parts of the premises within their control to the Building Coordinator
while acting in the performance of duties.
Sec. 35. Enforcement.
I. Orders. The Building Coordinator shall issue an order in writing requiring the remedying of
all conditions found to exist in or on any premises in violation of provisions of this
ordinance or of rules and regulations adopted thereunder. The order shall state a reasonable
time for compliance.
II. Dwellings to be Posted. Where violations of this ordinance exist and pose an immediate
hazard or danger to the health, safety or welfare of building occupants or of the public, the
Building Coordinator may declare the premises unfit for human habitation and order the
evacuation of all occupants. The premises shall be posted with notices of such order
prominently displayed at every entrance.
III. Removal of Notice Prohibited. It shall be unlawful to deface or remove the placard from
any premises, which have been condemned as unfit for human habitation and posted as
such.
IV. Posted Premises Not To Be Used for Human Habitation. No premises, which have been
condemned and posted as unfit for human habitation shall again be used for human
habitation until written approval is secured from, and, such notice is removed, by the
Building Coordinator, the Building Coordinator shall remove such notice whenever the
defect or defects upon which the condemnation order was based have been eliminated.
Sec. 36. Violations. Any person found guilty of violating any provision of this ordinance shall be
subject to a fine of not more than $100 for each offense. Each day in which a violation is
proved to exist shall constitute a separate offense under this section.